• Title/Summary/Keyword: Low Vibration

Search Result 2,166, Processing Time 0.03 seconds

DESIGN GUIDELINE FOR THE IMPROVEMENT OF DYNAMIC COMFORT OF A VEHICLE SEAT AND ITS APPLICATION

  • JANG H.-K.
    • International Journal of Automotive Technology
    • /
    • v.6 no.4
    • /
    • pp.383-390
    • /
    • 2005
  • This study proposes an innovative design guideline to assist the evaluation and improvement of the dynamic comfort of vehicle seating. The existing evaluation method for the comfort of vehicle seating was investigated to broach problems in evaluation. It was found that the currently existing evaluation method employs the resonance frequency of the vibration system composed of the seat and the human body and the maximum vibration transmissibility. This study proposes a design guideline aimed at the enhancement of vibration transmission characteristics above the resonance range, particularly within the range of 10-18 Hz. In order to meet this guideline, a seat was constructed out of foam having a low damping coefficient. It was then installed in a vehicle for a driving test. The driving test confirmed the improvement of the dynamic comfort of the seat. The result of evaluation of the improved seat using the SEAT index, an industry standard widely used to evaluate the dynamic comfort of a seat considering the perceptivity characteristics of the human body, showed that the perceptive vibration transmission had reduced by more than $11\%$. The effect of the modification of seat foam was also verified through a subjective assessment of dynamic comfort of the seats.

Bender-type Multilayer Piezoelectric Devices for Energy Harvesting (미소에너지 하베스팅용 적층 벤더 압전 소자 성능 연구)

  • Jeong, Soon-Jong;Kim, Min-Soo;Kim, In-Sung;Song, Jae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.193-193
    • /
    • 2008
  • Wearable and ubiquitous micro systems will be greatly growing and their related devices should be self-powered in order to avoid the replacement of finite power sources, for example, by scavenging energy from the environment. With ever reducing power requirements of both analog and digital circuits, power scavenging approaches are becoming increasingly realistic. One approach is to drive an electromechanical converter from ambient motion or vibration. Vibration-driven generators based on electromagnetic, electrostatic and piezoelectric technologies have been demonstrated. Among various generator types proposed so far, piezoelectric generator possesses considerable potential in micro system. To overcome low mechanical-to-electric energy conversion, the piezoelectric device should activate in resonance mode in response to external vibration. Normally, the external vibration excretes at low frequency ranging 0.1 to 200 Hz, whereas the resonant frequencies of the devices are fixed as constant. Therefore, keeping their resonant mode in varying external vibration can be one of important points in enhancing the conversion efficiency. We investigated the possibility of use of multi-bender type piezoelectric devices. To match the external vibration frequency with the device resonant frequency, the various devices with different resonant frequency were chosen.

  • PDF

The evaluation of Secondary pump vibration at Tongyoeng LNG recieving terminal in Korea Gas Corporation (한국가스공사 통영생산기지의 초저온 펌프의 진동 진단)

  • Koh, J.P.;Kim, J.H.;Hong, S.K.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1637-1641
    • /
    • 2003
  • Korea Gas Corporation(KOGAS) is a Liquified Natural Gas(LNG) supplier through out the Korea. LNG, which is imported wholly from foreign countries, is compressed 1/600 for easy transportation and is stored in a liquid state in the storage tanks at Incheon, Pyeongtaek and Tongyeong. At LNG receiving terminals, LNG is vaporized to natural gas before supplying to City Gas Consumer of Power Plant. The secondary pump is a equipment which compress LNG from 1- kgf/cm2 to 70 kgf/cm2. The secondary pump at Tongyeong LNG receiving terminal is consisted of two pumps in one underground PIT, and is connected to supporting structures. It is therefore expected that there is a vibration problem whit the pump and was found that high level vibration was occurred in a low frequency band($5^{\sim}10Hz$). In this paper, the vibration of secondary pump was analyzed, and the main cause of vibration was found out.

  • PDF

A Study on the Longitudinal Hull Girder Vibration of a 73,000 Deadweight Bulk Carrier (73,000톤 산적화물선의 선체거더 종진동 현상분석)

  • Jong-Gug Bae;Kyoon-Yang Chung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.32 no.2
    • /
    • pp.103-107
    • /
    • 1995
  • Longitudinal hull girder vibration has not been occurred severely since 1960's. However, recent low speed diesel driven ships equipped with overcritical shafting system, can be excited heavily in longitudinal direction by shaft axial farce coupled with torsional vibration. In this study the characteristics of longitudinal hull girder vibration of a 73,000 deadweight bulk carrier were investigated through onboard measurement, exciter test, and 3-D FEM analysis. Results showed that the longitudinal hullgirder vibration may occur in the ship which is not set up the barred speed range in engine operation. Moreover, this vibration occurs. only during the low speed voyage in harbour depending upon the ship loading condition.

  • PDF

Assesment on the Transformation of Psychological Risk Images due to Development of Flight Skills (조종 숙련도 변화에 따른 심리적 리스크 이미지의 변화에 대한 평가)

  • Kim, Yeong-Gwan;Im, Hyeon-Gyo
    • Journal of the Ergonomics Society of Korea
    • /
    • v.22 no.1
    • /
    • pp.57-67
    • /
    • 2003
  • The resonance behaviour needs be understood to identify the mechanisms responsible for the dynamic characteristics of human body, to allow for the non-linearity when predicting the influence of seating dynamics. and to predict the adverse effects caused by various magnitudes of vibration. However, there are currently no known studies on the effect of vibration magnitude on the transmissibility to thoracic or lumbar spine of the seated person. despite low back pain(LBP) being the most common ailment associated with whole-body vibration. The objective of this paper is to develop a proper mathematical human model for LBP and musculoskeletal injury of the crew in a maritime vehicle. In this study, 7 degree-of-freedom including 2 non-rigid mass representing wobbling visceral and intestine mass, is proposed. Also. when compared with previously published experimental results, the model response was found to be well-matching. When exposed to various of vertical vibration, the human model shows appreciable non-linearity in its biodynamic responses. The relationships of resonance for LBP and musculoskeletal injury during whole-body vibration are also explained.

Biomaterials toward Future Medicine

  • Sakurai, Yasuhisa
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.2
    • /
    • pp.117-118
    • /
    • 1986
  • It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization.

  • PDF

Development of n Low Frequency Vibration Shaker Using Force Frequency Shifting (가진주파수 이동현상을 이용한 저주파 가진기의 개발)

  • Lee, Gun-Myung;L.Koss;Lee, Jung-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.324.2-324
    • /
    • 2002
  • If a sinusoidal excitation force moves back and forth along a structure with a certain frequency, the structure will be excited with the difference frequency of these two frequencies. A low frequency vibration shaker has been developed using this force frequency shifting without actually moving a shaker. The shaker consists of an ordinary eccentric mass shaker, a plate, constant springs, and time varying dampers. The dampers are fumed on and off in a sequential manner to simulate a traveling slide of an excitation force. (omitted)

  • PDF

Dynamic Analysis and Driving Input Shaping of Inchworm (이송자벌레의 동적 해석 및 구동 입력신호 설계)

  • Kim, In-Soo;Kim, Yeung-Shik
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.7
    • /
    • pp.756-763
    • /
    • 2008
  • This paper presents an inchworm with three piezoelectric actuators. The dynamic stiffness of the inchworm is generally low compared to its driving condition, so mechanical vibration may degenerate the motion accuracy of the inchworm. The dynamic model of inchworm is identified by curve fitting technique based on the experimental frequency response function. For the precision motion control and low residual vibration of inchworm, driving input signal is designed by using cycloid step input and LQG control technique. Experimental result shows that proposed input shaping method is applicable effectively to the inchworm.

Performance Improvement of a Polygon Mirror Scanner Motor for Laser Beam Printer (레이저빔프린터용 폴리곤 미러 스캐너 모터의 특성개선)

  • You, Yong-min
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.854-855
    • /
    • 2015
  • Electric machines for office automation device such as printer and scanner have been required the low noise and vibration performance. Many researches about the low noise and vibration of polygon mirror scanner motor have been also progressed. The noise and vibration of polygon mirror scanner motor can be classified by aerodynamic, structural and electromagnetic. Electromagnetic noise and vibration can be occurred by high cogging torque and nonsinusoidal back EMF. To improve the cogging torque and back EMF characteristic, we apply unequal air-gap. To analyse characteristic of a polygon mirror scanner motor, two dimensional finite element method is used. To minimize the cogging torque of a polygon mirror motor, Kriging based on latin hypercube sampling (LHS) is utilized. As a result, the cogging torque and torque ripple improved while maintaining the back EMF and average torque.

  • PDF

Low Noise Characteristics of SRM Drive with Hybrid Excitation (하이브리드 여자방식 SRM의 저소음 구동특성)

  • Kim, C.S.;Oh, S.G.;Ahn, J.W.;Kim, C.W.
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.53-56
    • /
    • 2001
  • The simple construction and low cost, fault tolerant power electronic drive has made the switched reluctance drive a strong contender for many applications. But the switched reluctance drive does exhibit higher levels of vibration and acoustic noise than most competing drives. The main source of vibration in the switched reluctance drive is generated by rapid change of radial force when phase current is extinguished by commutation action. In this paper, a hybrid excitation method is proposed to reduce vibration and acoustic noise of the switched reluctance drive. The hybrid excitation has 2-phase excitation by long dwell angle as well as conventional 1-phase excitation. The vibration and acoustic noise are reduced because the scheme reduces abrupt change of excitation level by distributed and balanced excitation.

  • PDF