• 제목/요약/키워드: Low Vibration

검색결과 2,166건 처리시간 0.033초

주증기 배관 헤더의 맥동이 분기 배관에 미치는 영향 (Vibration Effect for Branch Pipe System due to Main Steam Header Pulsation)

  • 김연환;배용채;이현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.780-785
    • /
    • 2005
  • Vibration has been severly increased at the branch pipe of main steam header since the commercial operation of a nuclear power plant. Intense broad band disturbance flow at the discontinuous region such as elbow, valve or heather generates the acoustical pulsation which is propagated through the piping system. The pulsation becomes the source of low frequency vibration at piping system. If it coincide with natural frequency of the pipe system, excessive vibration is made. High level vibration due to the pressure pulsation related to high dynamic stress, and ultimately, to failure probability affects fatally the reliability and confidence of plant piping system. This paper discusses vibration effect for the branch pipe system due to acoustical pulsations by broad band disturbance flow at the large main steam header in 7nn nuclear power plant. The exciting sources and response or the piping system are investigated by using on site measurements and analytical approaches. It is identified that excessive vibration is caused by acoustical pulsations of 1.3Hz, 4.4Hz and 6.6Hz transferred from main steam header, which are coincided with fundamental natural frequencies of the piping structure. The energy absorbing restraints with additional stiffness were installed to reduce excessive vibration.

  • PDF

인공위성발사체 상단부 진동환경시험을 위한 치구설계 (Vibration Fixture design for small satellite launch vehicle environment test)

  • 정호경;서상현;박순홍;장영순;이영무
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.258-262
    • /
    • 2007
  • Satellite launch vehicle is exposed to some dynamic environment during its flight. Particularly, the safety of launch vehicle structure is surely verified under vibration environment in low frequency range. Sine sweep test is generally performed to describe this low frequency vibration environment. Dynamic property of vibration fixture is considered to get the correct property of target object. This vibration fixture should really be an extension of the armature in the form of a very rigid structure that can transfer the required force at the required frequency. An optimum fixture would have its lower natural frequency about 50% higher than the highest required forcing frequency in order to avoid fixture resonances during the test. In this study, the vibration mode analysis considering the mass of target object to design the vibration fixture. And the modal test of vibration fixture is performed to conform the design.

  • PDF

일부지역 탄광 착암 근로자의 진동증후군 유병율 (Prevalence of the Vibration Syndrome among Rock-drillers in the Anthracite Mining Area)

  • 노재훈
    • Journal of Preventive Medicine and Public Health
    • /
    • 제14권1호
    • /
    • pp.75-80
    • /
    • 1981
  • Due to rapid industrialization and economic development, the occupational diseases have appeared as one of the social problems in Korea. Up until now little has been known about the prevalence rate, predisposing factors and symptomatology of the occupational disease due to localized vibration in Korea. The researcher intends to investigate the prevalence rate and affecting factors of the occupational disease due to localized vibration among rock-drillers in the anthracite mines. A total of 135 rock-drillers were interviewed and examined from May 15th to 31th, 1980. The results were revealed as follows; 1. The prevalence rate of the vibration syndrome among rock-drillers was 12.6%. 2. The latent period of the vibration syndrome was 6.8 years. 3. The prevalence rate of the vibration syndrome was not significantly different between smokers and non-smokers. 4. With the increase of total vibration exposure time, the prevalence rate of the vibration syndrome increased also. 5. The average vibration sensation threshold was high (6.4dB) in stage 1 of the vibration syndrome and low (-0.6dB) in stage 0. 6. The average pain sensation threshold was high (4.4g) in stage 1 of the vibration syndrome and low (2.5g) in stage 0.

  • PDF

PSO알고리즘을 활용한 능동 제진 시스템 PID 오토 튜닝에 관한 연구 (A Study on the Active Vibration Isolator PID Auto-tuning Using PSO Algorithm)

  • 안일균;허헌;김효영;김기현
    • 반도체디스플레이기술학회지
    • /
    • 제21권4호
    • /
    • pp.59-64
    • /
    • 2022
  • Vibration is one of the factors that degrades the performance of equipment and measurement equipment used in high-tech industries such as semiconductors and display. The vibration isolator is classified into passive type and active type. The passive vibration isolator has the weakness of insufficient vibration isolation performance in the low frequency band, so an active vibration control system that can overcome these problems is used recently. In this paper, PID controller is used to control the active vibration isolator. Methods for setting the gain of the PID controller include the Zeigler-Nichols method, the pole placement method. These methods have the disadvantage of requiring a lot of time or knowing the system model accurately. This paper proposes the gain auto tuning method of the active vibration isolator applied with the PSO algorithm, which is an optimization algorithm that is easy to implement and has stable convergence performance with low calculations. It is expected that it will be possible to improve vibration isolation performance and reduce the time required for gain tuning by applying the proposed PSO algorithm to the active vibration isolator.

Effect of low frequency oscillations during milking on udder temperature and welfare of dairy cows

  • Antanas Sederevicius;Vaidas Oberauskas;Rasa Zelvyte;Judita Zymantiene;Kristina Musayeva;Juozas Zemaitis;Vytautas Jurenas;Algimantas Bubulis;Joris Vezys
    • Journal of Animal Science and Technology
    • /
    • 제65권1호
    • /
    • pp.244-257
    • /
    • 2023
  • The study aimed to investigate the effect of low-frequency oscillations on the cow udder, milk parameters, and animal welfare during the automated milking process. The study's objective was to investigate the impact of low-frequency oscillations on the udder and teats' blood circulation by creating a mathematical model of mammary glands, using milkers and vibrators to analyze the theoretical dynamics of oscillations. The mechanical vibration device developed and tested in the study was mounted on a DeLaval automatic milking machine, which excited the udder with low-frequency oscillations, allowing the analysis of input parameters (temperature, oscillation amplitude) and using feedback data, changing the device parameters such as vibration frequency and duration. The experimental study was performed using an artificial cow's udder model with and without milk and a DeLaval milking machine, exciting the model with low-frequency harmonic oscillations (frequency range 15-60 Hz, vibration amplitude 2-5 mm). The investigation in vitro applying low-frequency of the vibration system's first-order frequencies in lateral (X) direction showed the low-frequency values of 23.5-26.5 Hz (effective frequency of the simulation analysis was 25.0 Hz). The tested values of the first-order frequency of the vibration system in the vertical (Y) direction were 37.5-41.5 Hz (effective frequency of the simulation analysis was 41.0 Hz), with higher amplitude and lower vibration damping. During in vivo experiments, while milking, the vibrator was inducing mechanical milking-similar vibrations in the udder. The vibrations were spreading to the entire udder and caused physiotherapeutic effects such as activated physiological processes and increased udder base temperature by 0.57℃ (p < 0.001), thus increasing blood flow in the udder. Used low-frequency vibrations did not significantly affect milk yield, milk composition, milk quality indicators, and animal welfare. The investigation results showed that applying low-frequency vibration on a cow udder during automatic milking is a non-invasive, efficient method to stimulate blood circulation in the udder and improve teat and udder health without changing milk quality and production. Further studies will be carried out in the following research phase on clinical and subclinical mastitis cows.

초정밀 듀얼 스테이지를 위한 고댐핑 저진동 제어기 개발 (Development of Low-Vibration Controller for Ultra-Precision Dual Stage)

  • 강석일;김정한
    • 한국생산제조학회지
    • /
    • 제25권1호
    • /
    • pp.75-82
    • /
    • 2016
  • In this study, a cross-damped low vibration controller was developed to reduce vibration in ultra-precision dual stage driven by master/slave principle. In master-slave structure, the master stage leads the driving motion and the slave stage follows it so as to maintain a constant gap between two stages. In this structure, a small perturbation of master stage makes big oscillations in slave servoing stage, so a low damped master stage composed of voice coil motor makes a long vibration in settling area after driving motion profile. In this research, an effective feedback damping algorithm for increase the damping characteristics of the dual stage was developed. The designed velocity damping algorithm improves the system stability and reduces the settling time of the whole system. Simulation and experimental results show that the developed algorithm reduces settling time and improves the regulating performance.

Vortex-induced vibration characteristics of a low-mass-ratio flexible cylinder

  • Quen, Lee Kee;Abu, Aminudin;Kato, Naomi;Muhamad, Pauziah;Siang, Kang Hooi;Hee, Lim Meng;Rahman, Mohd Asamudin A
    • Structural Engineering and Mechanics
    • /
    • 제75권5호
    • /
    • pp.621-631
    • /
    • 2020
  • A laboratory experiment is conducted is to investigate the behaviour of a low-mass-ratio and high aspect ratio flexible cylinder under vortex-induced vibration (VIV). A flexible cylinder with aspect ratio of 100 and mass ratio of 1.17 is towed horizontally to generate uniform flow profile. The range of Reynolds number is from 1380 to 13800. Vibration amplitude, in-line and cross-flow frequency response, amplitude trajectory, mean tension variation and hydrodynamic force coefficients are analyzed based on the measurement from strain gauges, load cell and CCD camera. Experimental results indicate that broad-banded lock-in region is found for the cylinder with a small Strouhal number. The frequency switches in the present study indicates the change of the VIV phenomenon. The hydrodynamic force responses provide more understanding on the VIV of a low mass ratio cylinder.

Effect of Neuromuscular Stabilization Exercise Program Using Whole Body Vibration on Patients with Low Back Pain

  • Park, Sam-Ho;Seo, Jin-Hyuk;Lee, Myung-Mo
    • Physical Therapy Rehabilitation Science
    • /
    • 제10권3호
    • /
    • pp.278-288
    • /
    • 2021
  • Objective: The purpose of this study is to investigate the effect of stabilization exercise on whole-body vibration on pain, dysfunction, psychosocial factors, balance ability, and abdominal contraction with patients with low back pain. Design: A randomized controlled trial Methods: A total of 34 patients with low back pain were assigned randomly to experimental group (n=17) and control group (n=17). Both groups underwent a neuromuscular stabilization exercise program. In addition, the experimental group implemented the neuromuscular stabilization exercise program using whole-body vibration. All interventions were applied 60 min per session, 3 times per week for total 4 weeks. Numeric Rating Scale (NRS), Korean version of Oswestry Disability Index (K-ODI), Fear-Avoidance Beliefs Questionnaire (FABQ), balance ability, muscle thickness and contraction ratio were compared to evaluate the effect on intervention. Results: Both groups showed significant differences in NRS, balance ability, and muscle thickness in contraction, contraction ratio before and after intervention (p<0.05). In addition, the experimental group showed significant difference in the amount of change in NRS, balance ability and muscle thickness in contraction, contraction ratio values than the control group (p<0.05). Conclusions: Neuromuscular stabilization exercise program combined with whole-body vibration stimulation has been proven to be an effective and clinically useful method to decrease pain, dysfunction, increase balance ablilty, and transverse abdominis muscle thickness in contraction and contraction ratio for patients with low back pain.

박막과의 연성에 의한 저주파 소음 저감 (Low frequency noise reduction by coupling with membrane)

  • 박수경;김양한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1996년도 추계학술대회논문집; 한국과학기술회관, 8 Nov. 1996
    • /
    • pp.148-152
    • /
    • 1996
  • A method of deminishing low frequency noise by acoustic acoupling with compliant wall is described. The coupled governing equations and boundary conditions are derived and solved. The coupled system shows very interesting behavior in the low frequency region; in the low frequency, acoustic wave doesn't propagate, but decay to satisfy the boundary condition with the compliant wall. Henceforth using this mechanism, we propose a method of reducing low frequency noise, which is infact related with the physical properties of compliant wall. The method has been experimentally verified.

  • PDF

Investigation of mode identifiability of a cable-stayed bridge: comparison from ambient vibration responses and from typhoon-induced dynamic responses

  • Ni, Y.Q.;Wang, Y.W.;Xia, Y.X.
    • Smart Structures and Systems
    • /
    • 제15권2호
    • /
    • pp.447-468
    • /
    • 2015
  • Modal identification of civil engineering structures based on ambient vibration measurement has been widely investigated in the past decades, and a variety of output-only operational modal identification methods have been proposed. However, vibration modes, even fundamental low-order modes, are not always identifiable for large-scale structures under ambient vibration excitation. The identifiability of vibration modes, deficiency in modal identification, and criteria to evaluate robustness of the identified modes when applying output-only modal identification techniques to ambient vibration responses were scarcely studied. In this study, the mode identifiability of the cable-stayed Ting Kau Bridge using ambient vibration measurements and the influence of the excitation intensity on the deficiency and robustness in modal identification are investigated with long-term monitoring data of acceleration responses acquired from the bridge under different excitation conditions. It is observed that a few low-order modes, including the second global mode, are not identifiable by common output-only modal identification algorithms under normal ambient excitations due to traffic and monsoon. The deficient modes can be activated and identified only when the excitation intensity attains a certain level (e.g., during strong typhoons). The reason why a few low-order modes fail to be reliably identified under weak ambient vibration excitations and the relation between the mode identifiability and the excitation intensity are addressed through comparing the frequency-domain responses under normal ambient vibration excitations and under typhoon excitations and analyzing the wind speeds corresponding to different response data samples used in modal identification. The threshold value of wind speed (generalized excitation intensity) that makes the deficient modes identifiable is determined.