• 제목/요약/키워드: Low Temperature Performance

검색결과 2,072건 처리시간 0.024초

히트펌프를 이용한 농산물 건조 및 저온저장 시스템 (II) - 사과의 저온저장 성능 - (Drying and Low Temperature Storage System of Agricultural Products using the Air to Air Heat Pump (II) - Performance of Low Temperature Storage for Apples -)

  • 강연구;한충수;금동혁
    • Journal of Biosystems Engineering
    • /
    • 제32권2호
    • /
    • pp.102-108
    • /
    • 2007
  • Heat pump systems are recognized to be heating and cooing systems. In this study, to check the practical application possibility of heat pump systems as low temperature storage systems and get basic data, apples of a long term storage items were stored and performance of low temperature storage and quality changes of apples were evaluated. Cooling coefficient of performance of the system was from 1.1 to 1.3. Although ambient air temperature varied widely from $-13^{\circ}C$ to $29.6^{\circ}C$ during low temperature storage period from January to June, the average temperature of low temperature storage chamber was $1.1^{\circ}C$ at setting temperature of $1.5^{\circ}C$. Sucrose of apples stored by the heat pump decreased from initial sucrose of 15.4% (Brix number) to final sucrose of 14.3%. Weight loss ratio of apples was 9.7% and internal and external view of apples after low temperature storage were very satisfactory with the naked eye.

Effect of Phenyl Vinyl Methyl Silicone (PVMQ) on Low Temperature Sealing Performance of Fluorosilicone Composites

  • Lee, Jin Hyok;Bae, Jong Woo;Choi, Myoung Chan;Yun, Yu-Mi;Jo, Nam-Ju
    • Elastomers and Composites
    • /
    • 제56권4호
    • /
    • pp.209-216
    • /
    • 2021
  • In this study, we observed the mechanical properties, thermal stability, and low temperature sealing performance of fluorosilicone elastic composites. When the blend ratio of Phenyl vinyl methyl silicone (PVMQ) was increased, the tensile strength, modulus at 100%, and compression set were decreased. The thermal stability of fluorosilicone elastic composites showed a similar tendency. These were caused by poorer green strength of PVMQ than Fluorosilicone rubber (FVMQ). The change in the tensile strength and elongation at -40℃ showed a decreasing tendency with increasing PVMQ blend ratio. By increasing the PVMQ blend ratio, low-temperature performance was improved. The Dynamic mechanical analysis (DMA) results showed that Tg was decreased and low-temperature performance was improved with increasing PVMQ blend ratio. However tanδ was decreased becaused of the poor green strength and elasticity of PVMQ. From a hysteresis loss at -40℃, the hysteresis loss value was increased and fluorosilicone elastic composites showed the decreasing tendency of elasticity with increasing PVMQ blend ratio. From the TR test, TR10 was decreased with increasing PVMQ blend ratio. FS-4 (45% PVMQ blended composites) showed a TR10 of -68.0℃ that was 5℃ lower than that of FS-1 (100% FVMQ). The gas leakage temperature was decreased with increasing PVMQ blend ratio. The gas leakage temperature of FS-4 was -69.2℃ that was 5℃ lower than that of FS-1. Caused by the polymer chain started to transfer from a glassy state to a rubbery state and had a mobility of chain under Tg, the gas leakage temperature showed a lower value than Tg. The sealing performance at low temperature was dominated by Tg that directly affected the mobility of the polymer chain.

Ni-MH 2차 전지의 저온특성에 미치는 전해액의 영향 (Influences of Various Electrolytes on the Low-Temperature Characteristics of Ni-MH Secondary Battery)

  • 박채규;심종수;장민호;박충년;최전
    • 한국수소및신에너지학회논문집
    • /
    • 제18권3호
    • /
    • pp.284-291
    • /
    • 2007
  • The Ni-MH batteries for HEV and industry are normally placed in outdoor, consequently causing an too weak discharge power problem due to a cold weather specially in winter time. In order to improve the low temperature performances of the Ni-MH battery for HEV and industrial uses, it has been investigated the low temperature discharge characteristics of Ni-MH battery with various electrolytes at $-18^{\circ}C$. The summary of experimental results are as follows. The low temperature characteristics depended strongly on the characteristics of electrolytes. When the concentration of the electrolytes were too high or too low the low temperature performance was poor. The best electrolyte was composed of KOH 6.2M+LiOH 1.2M. An addition of RbOH or CsOH to electrolyte improved the low temperature performance. The best total concentration of electrolyte composed of KOH, NaOH and LiOH was about 7M.

저온환경하 NT(Nano Technology)구조 단열재를 사용한 단열거푸집의 열적성능평가에 관한 실험적 연구 (A Experimental Study of Insulation Performance of Insulated Forms Utilizing NT frame Insulation at Low Temperature)

  • 박장현;김목규;김형철;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.179-180
    • /
    • 2015
  • In this study, the experimental study on Insulation performance of insulated forms utilizing NT frame heat insulation at low Temperature. For this study, placing insulated TEGO film plywood based form between two constant temperature and humidity chamber that maintaining 10℃, decrease temperature of one chamber to -10℃ and -20℃. Each of steps, maintaining period of temperature was 1 hour. After placing the insulated form, measure temperature of outside if insulated form. As a result of experiment, temperature difference of Fumed Silica Vacuum insulation was lowest.

  • PDF

저온환경하에서 단열처리 방법에 따른 단열거푸집의 열적성능에 관한 실험적 연구 (A Experimental Study on Thermal Performance of Insulated Forms with Different Insulating Methods at Low Temperature)

  • 김목규;김형철;최현국;김재영;문영범;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.57-58
    • /
    • 2015
  • In this study, the experimental study on Thermal Performance of Insulated Forms with Different Insulating Methods at Low Temperature. For this study, placing insulated plywood based form between two constant temperature chamber that maintaining 10℃, decrease temperature of one chamber to -10℃ and -20℃. Each of steps, maintaining period of temperature was 1 hour. After placing the form, measure temperature of opposite side of the insulated form. As a result of experiment, temperature difference of rigid urethane was lowest.

  • PDF

철도차량 고무 현가부품의 내한성 시험기준연구 (A Study on the Test Standards at Low Temperature of Rubber Suspension Components of Railway Vehicle)

  • 윤태호;장승호;최병일;이찬우;나희승
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.372-376
    • /
    • 2004
  • In this paper, the standard test methods at low temperature of rubber suspension components of railway vehicle are investigated and reviewed. In order to connect the TKR(Trans-Korean Railway)-TSR(Trans-Siberian Railway), it is necessary to evaluate the performance of rubber suspenion components of railway vehicle. In the current Korean Standard, the test method at low temperature of railway vehilce components and the test method of rubber bellows of air spring are specified. But, the specified test temperature is higher than the the operating temperature of TSR railway. So, the in-depth research for the test method and performance evaluation technique of rubber suspension component at low temperature is necessary and current KS code should be adjusted.

  • PDF

해수열원 캐스케이드 열펌프시스템의 운전 특성에 관한 실험적 연구 (An Experimental Study on the Performance of a Sea Water Heat Source Cascade Heat Pump)

  • 김지영;백영진;장기창;박성룡;나호상;이재훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.1969-1973
    • /
    • 2007
  • The purpose of this study is to investigate the performance of a sea water heat source cascade heat pump system. R717(Ammonia) is used for a low-stage working fluid while R134a is for a high-stage. In order to gain a high temperature supply water in winter season, the system is designed to perform a cascade cycle. In this study, two experiments were carried out. One is a system starting test from the low load temperature of $10^{\circ}C$. The other is a system performance investigation over the R717 compressor capacity changes. Experimental results show that when it starts from the low load temperature, the suction temperature of the low-stage compressor is higher than that of a high-stage. The system performance increases when a water source temperature or a low-stage compressor rotational frequency goes higher.

  • PDF

캐스케이드 열펌프시스템의 운전 특성에 관한 연구 (A Study on the Operating Performance of a Cascade Heat Pump)

  • 장기창;백영진;나호상;김지영;이재훈
    • 한국지열·수열에너지학회논문집
    • /
    • 제5권1호
    • /
    • pp.7-11
    • /
    • 2009
  • The purpose of this study is to investigate the performance of a water heat source cascade heat pump system R717(Ammonia) is used for a low-stage working fluid while R134a is for a high-stage. In order to gain a high temperature supply water in winter season, the system is designed to perform a cascade cycle. In this study, two experiments were carried out. One is a system starting test from the low load temperature of $10^{\circ}C$. The other is a system performance investigation over the R717 compressor capacity changes. Experimental results show that when it starts from the low load temperature, the suction temperature of the low-stage compressor is higher than that of a high-stage. The system performance increases when a water source temperature or a low-stage compressor rotational frequency goes higher.

  • PDF

Low-Temperature Processable Charge Transporting Materials for the Flexible Perovskite Solar Cells

  • Jo, Jea Woong;Yoo, Yongseok;Jeong, Taehee;Ahn, SeJin;Ko, Min Jae
    • Electronic Materials Letters
    • /
    • 제14권6호
    • /
    • pp.657-668
    • /
    • 2018
  • Organic-inorganic hybrid lead halide perovskites have been extensively investigated for various optoelectronic applications. Particularly, owing to their ability to form highly crystalline and homogeneous films utilizing low-temperature solution processes (< $150^{\circ}C$), perovskites have become promising photoactive materials for realizing high-performance flexible solar cells. However, the current use of mesoporous $TiO_2$ scaff olds, which require high-temperature sintering processes (> $400^{\circ}C$), has limited the fabrication of perovskite solar cells on flexible substrates. Therefore, the development of a low-temperature processable charge-transporting layer has emerged as an urgent task for achieving flexible perovskite solar cells. This review summarizes the recent progress in low-temperature processable electron- and hole-transporting layer materials, which contribute to improved device performance in flexible perovskite solar cells.

저온진공건조 공정에 제습제 적용을 위한 타당성 연구 (Feasibility Study for Applying Desiccant to Low Temperature Vacuum Drying Process)

  • 심연호;강지수;변시예;장영수;강병하
    • 설비공학논문집
    • /
    • 제28권5호
    • /
    • pp.208-215
    • /
    • 2016
  • This study was conducted to improve the performance of low-temperature vacuum dryer by applying desiccant to cold trap. Performance evaluation was carried out using several desiccants. The amounts of absorption and diffusivity were measured based on analytic model. Results of desiccant performance evaluation revealed that silica-gel had the most excellent performance for conditions of low-temperature vacuum drying process. Silica-gel was applied to cold trap for evaluating the drying performance. The experiment results showed that the drying time was extended as the thickness of sample was increased due to increased heat and mass transfer resistance of drying sample. In addition, as heating plate temperature was increased, drying time was decreased due to increased evaporation pressure of drying sample. Furthermore, drying time with desiccant was decreased approximately 20% than that without desiccant.