• Title/Summary/Keyword: Low Power Physics test

Search Result 10, Processing Time 0.032 seconds

The design and fabrication of 81.25 MHz RFQ for Low Energy Accelerator Facility

  • Zhao, Bo;Chen, Shuping;Zhu, Tieming;Wang, Fengfeng;Jin, Xiaofeng;Li, Chenxing;Ma, Wei;Zhang, Bin
    • Nuclear Engineering and Technology
    • /
    • v.51 no.2
    • /
    • pp.556-560
    • /
    • 2019
  • To provide high shunt impendence with low power losses, an 81.25 MHz continuous wave (CW) radio frequency quadrupole (RFQ) accelerator has been designed and machined as parts of the Low Energy Accelerator Facility (LEAF). In this paper, the mechanical structure and the main processing technology of the RFQ cavities are described according to the physical and geometric parameters requirements of the RFQ. The fabrication of the RFQ has been completed and the test results agree well with the design requirements. The RFQ accelerator will work in Institute of Modern Physics, Chinese Academy of Sciences in 2018.

Research of aluminum nitride water load for the 4.6 GHz 500 kW LHCD system of the CFETR

  • Dingzhen Li;Liyuan Zhang;Lianmin Zhao;Fukun Liu;Min Cheng;Huaichuan Hu;Taian Zhou
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3126-3132
    • /
    • 2023
  • To meet the increasing heating needs of the China Fusion Experimental Tokamak Reactor (CFETR), the output power in each Lower Hybrid Current Drive (LHCD) transmission line should be increased from 250 kW to 500 kW. Therefore, a new high-power water load must be developed for the 4.6 GHz 500 kW LHCD system. This paper aims to report the most recent research progress of the water load: aluminum nitride (AlN) ceramic is used as the media material to isolate the water and vacuum, and the radio frequency (RF) simulation results show that the return loss of the water load is less than -25dB at 4.6 GHz over a wide temperature range. Under 500 kW continuous wave (CW) operation, the maximum temperatures of the ceramic and water are separately 67 ℃ and 62 ℃, resulting in thermal deformation of the ceramic of approximately 0.003 mm. Moreover, the AlN water load was tested on the 4.6 GHz 250 kW high-power test bench and found to work well with low reflected power.

A Study on the Effect of Gamma Background in Low Power Startup Physics Tests (저출력 노물리 시험에서의 감마 Background의 영향에 관한 연구)

  • Bae, Chang-Joon;Lee, Ki-Bog
    • Nuclear Engineering and Technology
    • /
    • v.25 no.3
    • /
    • pp.361-370
    • /
    • 1993
  • Low power physics tests should be peformed for the domestic pressurized light water reactors (PWRs) after refueling. The tests are peformed to ensure that operating characteristics of the core are consistent with predictions and that the core can be operated as designed. But in some low power physics tests, slow but steady reactivity increasing phenomena were noticed after step reactivity insertion by the control rod movement. These reactivity increasing phenomena are due to the low flux level and the gamma background because an uncompensated ion chamber (UIC) is used as the ex-core neutron detector. The gamma background may affect the results or the lour power physics tests. The aims or this paper are to analyze the grounds of such phenomena, to simulate a reference bank worth measurement test and to present a resolution quantitatively. In this study, the gamma background level was estimated by numerically solving the point kinetics equations accounting the gamma background effect. The reactivity computer check test was simulated to verify the model. Also, an appropriate neutron flux level was determined by simulating the reference bank worth measurement test. The determined neutron flux level is approximately 0.3 of the nuclear heating flux. This level is about 3 times as high as the current test upper limit specified in the test procedure. Then, the findings from this work were successfully applied to Kori unit 4 cycle 7 and Yonggwang unit 1 cycle 7 physics tests.

  • PDF

EVALUATION OF THE APPLICABLE REACTIVITY RANGE OF A REACTIVITY COMPUTER FOR A CANDU-6 REACTOR

  • Lee, Eun Ki;Park, Dong Hwan;Lee, Whan Soo
    • Nuclear Engineering and Technology
    • /
    • v.46 no.2
    • /
    • pp.183-194
    • /
    • 2014
  • Recently, a CANDU digital reactivity computer system (CDRCS) to measure the worth of the liquid zone controller in a CANDU-6 was developed and successfully applied to a physics test of refurbished Wolsong Unit 1. In advance of using the CDRCS, its measureable reactivity range should be investigated and confirmed. There are two reasons for this investigation. First, the CANDU-6 has a larger reactor and smaller excore detectors than a general PWR and consequently the measured reactivity is likely to reflect the peripheral power variation only, not the whole core. The second reason is photo neutrons generated from the interaction of the moderator and gamma-rays, which are never considered in a PWR. To evaluate the limitations of the CDRCS, several tens of three-dimensional steady and transient simulations were performed. The simulated detector signals were used to obtain the dynamic reactivity. The difference between the dynamic reactivity and the static worth increases in line with the water level changes. The maximum allowable reactivity was determined to be 1.4 mk in the case of CANDU-6 by confining the difference to less than 1%.

Ferroelectric-gate Field Effect Transistor Based Nonvolatile Memory Devices Using Silicon Nanowire Conducting Channel

  • Van, Ngoc Huynh;Lee, Jae-Hyun;Sohn, Jung-Inn;Cha, Seung-Nam;Hwang, Dong-Mok;Kim, Jong-Min;Kang, Dae-Joon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.427-427
    • /
    • 2012
  • Ferroelectric-gate field effect transistor based memory using a nanowire as a conducting channel offers exceptional advantages over conventional memory devices, like small cell size, low-voltage operation, low power consumption, fast programming/erase speed and non-volatility. We successfully fabricated ferroelectric nonvolatile memory devices using both n-type and p-type Si nanowires coated with organic ferroelectric poly(vinylidene fluoride-trifluoroethylene) [P(VDF-TrFE)] via a low temperature fabrication process. The devices performance was carefully characterized in terms of their electrical transport, retention time and endurance test. Our p-type Si NW ferroelectric memory devices exhibit excellent memory characteristics with a large modulation in channel conductance between ON and OFF states exceeding $10^5$; long retention time of over $5{\times}10^4$ sec and high endurance of over 105 programming cycles while maintaining ON/OFF ratio higher $10^3$. This result offers a viable way to fabricate a high performance high-density nonvolatile memory device using a low temperature fabrication processing technique, which makes it suitable for flexible electronics.

  • PDF

Reliability Evaluation and failure Analysis for High Voltage Ceramic Capacitor (고압 커패시터의 고장분석과 신뢰성 평가)

  • 김진우;송옥병;신승우;이희진;신승훈;유동수
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2001.06a
    • /
    • pp.337-337
    • /
    • 2001
  • High voltage ceramic capacitors are widely applied in power electronic circuits, such as filters, snubbers, and resonant circuits, due to their excellent features of high voltage endurance and low aging. This paper presents a result of failure analysis and reliability evaluation for high voltage ceramic capacitors. The failure nodes and failure mechanisms were identified in order to understand the failure physics in a component. The causes of failure mechanisms for zero resistance phenomena under withstanding voltage test in high voltage ceramic capacitors molded by epoxy resin were studied by establishing an effective closed-loop failure analysis. Also, the condition for dielectric breakdown was investigated. Particular emphasis was placed on breakdown phenomena at the ceramic-epoxy interface. The validity of the results in this study was confirmed by the results of accelerated testing. Thermal shock test as well as pressure cooker test for high voltage ceramic capacitor mounted on a magnetron were implemented. Delamination between ceramic and epoxy, which, might cause electrical short in underlying circuitry, can occur during curing or thermal cycling. The results can be conveniently used to quickly identify defective lots, determine mean time to failure (MTTF) of each lot at the level of Inspection, and detect major changes in the vendors processes.

  • PDF

Optical and Electrical Characteristics of GaN-based Blue LEDs after Low-current Stress (GaN계 청색 발광 다이오드에서 저전류 스트레스 후의 광 및 전기적 특성 변화)

  • Kim, Seohee;Yun, Joosun;Shin, Dong-Soo;Shim, Jong-In
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.2
    • /
    • pp.64-70
    • /
    • 2012
  • We analyzed the changes in electrical and optical characteristics of 1 $mm^2$ multiple-quantum-well (MQW) blue LEDs grown on a c-plane sapphire substrate after a stress test. Experiments were performed by injecting 50 mA current for 200 hours to TO-CAN packaged sample chips. We selected the value of injection current for stress through the junction-temperature measurement by using the forward-voltage characteristics of a diode to maintain a sufficiently low junction temperature during the test. The junction temperature at the selected injection current of 50 mA was 308 K. Experiments were performed under the assumption that the average junction temperature of 308 K did not affect the characteristics of the ohmic contact and the GaN-based materials. Before and after the stress test, we measured and analyzed current-voltage, light-current, light distribution on the LED surface, wavelength spectrum and relative external quantum efficiency (EQE). After the stress test, it was observed experimentally that the optical power and the relative EQE decreased. We theoretically investigated and experimentally proved that these phenomena are due to the increased nonradiative recombination rate caused by the increased defect density.

Survey on the Refractive Errors Status in the First Wearing Glasses (최초 안경착용시의 굴절이상 상태 조사)

  • Kim, Hye-Ran;Jang, Seong-Ju;Shim, Hyun-Seog
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.113-117
    • /
    • 2008
  • Purpose: This study is to survey that uncomfortable feeling of visual acuity in the first wearing glasses, the number of visiting in age, above vision ranging and refractive errors, astigmatism, and anisometropia. Methods: Automatic refraction and naked visual acuity test executed to receive prescription glasses that the man 509 and women's 499 people visited for the first time, among 3~15 years old who visited an ophthalmoiogical hospital, from January to December, 2003. Results: The first wearing glasses started 3 years old and the most cases was 8~9 years old when they were visited visual acuity 0.5 to 0.7 in most cases. Refractive errors appeared 8 years old and its most plentifully with 20.4%, 92.2% was myopia and 5.2% was hyperopia for the man. Also cases of women was 91.9% for myopia and 5.1% for the hyperopia. Spherical equivalent power was S-1.50${\pm}$1.10D and appeared 62.3% for the low myopia. Astigmatism was appeared 44.6% for the with the rule astigmatism and 75% was cylinder power lower than 1.00D. Cases of simple astigmatism need to glass when was cylinder power C-1.37${\pm}$1.01D, and C-0.50D appeared most distribution. More than 2.00D anisometropia appeared 2.3% for the whole subjective. Conclusions: Of the first wearing glasses visual acuity is 0.5~0.7, spherical equivalent power is S-1.50${\pm}$1.10D, cylinder power of simple astigmatism is C-1.37${\pm}$1.01D.

  • PDF

Evaluation of Cryogenic Compressive Strength of Divinycell of NO 96-type LNG Insulation System (NO96타입 LNG 방열시스템 Divinycell의 극저온 압축 강도 평가)

  • Choe, Yeong-Rak;Kim, Jeong-Hyeon;Kim, Jong-Min;Park, Sungkyun;Park, Kang Hyun;Lee, Jae-Myung
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.5
    • /
    • pp.349-355
    • /
    • 2016
  • Divinycell, which functions as both insulation and a supporting structure, is generally applied in the NO96-type liquefied natural gas (LNG) insulation system. Polymer-material-based Divinycell, which has a high strength and low weight, has been widely used in the offshore, transportation, wind power generation, and civil engineering fields. In particular, this type of material receives attention as an insulation material because its thermal conductivity can be lowered depending on the ambient temperature. However, it is difficult to obtain research results for Divinycell, even though the component materials of the NO96-type LNG cargo containment system, such as 36% nickel steel (invar steel), plywood, perlite, and glass wool, have been extensively studied and reported. In the present study, temperature and strain-rate dependent compressive tests on Divinycell were performed. Both the quantitative experimental data and elastic recovery are discussed. Finally, the mechanical characteristics of Divinycell were compared to the results of polyurethane foam insulation material.