• 제목/요약/키워드: Low Power Management

검색결과 806건 처리시간 0.033초

글리치를 고려한 매핑가능 클러스터 생성 방법을 이용한 저전력 알고리즘 (The Low Power Algorithm using a Feasible Clustert Generation Method considered Glitch)

  • 김재진
    • 디지털산업정보학회논문지
    • /
    • 제12권2호
    • /
    • pp.7-14
    • /
    • 2016
  • In this paper presents a low power algorithm using a feasible cluster generation method considered glitch. The proposed algorithm is a method for reducing power consumption of a given circuit. The algorithm consists of a feasible cluster generation process and glitches removal process. So that glitches are not generated for the node to which the switching operation occurs most frequently in order to reduce the power consumption is a method for generating a feasible cluster. A feasible cluster generation process consisted of a node value set, dividing the node, the node aligned with the feasible cluster generation. A feasible cluster generation procedure is produced from the highest number of nodes in the output. When exceeding the number of OR-terms of the inputs of the selected node CLB prevents the signal path is varied by the evenly divided. If there are nodes with the same number of outputs selected by the first highest number of nodes in the input produces a feasible cluster. Glitch removal process removes glitches through the path balancing in the same manner as [5]. Experimental results were compared with the proposed algorithm [5]. Number of blocks has been increased by 5%, the power consumption was reduced by 3%.

히트펌프 온수기 개발을 위한 계측 및 성능평가시스템 구축 (Development of Measurement and Performance Testing System for Heat Pump water Heater)

  • 권성철;양승권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 D
    • /
    • pp.2310-2312
    • /
    • 2004
  • In Korea Electric Power Corporation (or KEPCO), several Demand-Side Management (or DSM) program have been carried out to effectively meet electric power demand at least costs by modifying customers electricity use patterns. As one of them, KEPCO applies low-priced night thermal-storage power service for heat appliances to facilitate efficient use of power facilities by shifting relatively high daytime demands to night hours to build loads during the off-peak periods. In the market of heat-storage type water-heater, electric water-heater has been mostly used, but it has low energy efficiency and needs high capacity electric equipments. So in order to replace these electric water heaters, 15 HP air-source heat pump water heater is developed in Korea Electric Research Institute (or KEPRI). This paper shows that measurement system for performance testing of heat pump water heater is established and heating capacity and performance is analyzed and measured for out-door environmental change.

  • PDF

스마트폰 기반의 지능형 수배전반 모니터링 시스템 구현 (Development of Intelligent Switchgear Monitoring System based on Smartphone)

  • 정해경;전감표;정도운
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2012년도 춘계학술대회
    • /
    • pp.378-379
    • /
    • 2012
  • 현재 에너지 소비가 증가하면서 환경적인 이슈로 전력 산업의 고도화 및 에너지 효율화에 대한 요구가 증가함에 따라 지능형 전력시스템과 같은 전력 IT 산업이 신 성장 동력으로 주목받고 있다. 지능형 전력 시스템을 통해 전력 수요에 따른 공급의 밸런스를 최적화하게 되면 에너지 수입 및 전력 인프라 건설, 운영에 소요되는 막대한 비용을 절감할 수 있고, 안정적으로 전력을 공급할 수 있게 된다. 하지만, 모든 설비 및 장비를 실시간 관리하기 위해서는 인력낭비가 발생할 뿐만 아니라, 응급 상황을 인지하지 못해 전력사고로 이어지는 문제가 발생할 수 있다. 따라서, 본 논문에서는 스마트폰 기반의 원격 제어 및 모니터링 기능을 구비한 지능형 수배전반 통합관리 시스템을 개발하였다. 기존의 수배전반 관리 시스템의 단점을 보완한 본 시스템은 저비용으로 효율성과 안정성을 대폭 향상 시킬 수 있어, 향후 전력 IT 산업의 발전에 크게 도모할 수 있을 것으로 판단된다.

  • PDF

A Photovoltaic Power Management System using a Luminance-Controlled Oscillator for USN Applications

  • Jeong, Ji-Eun;Bae, Jun-Han;Lee, Jinwoong;Lee, Caroline Sunyong;Chun, Jung-Hoon;Kwon, Kee-Won
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제13권1호
    • /
    • pp.48-57
    • /
    • 2013
  • This paper presents a power management system of the dye-sensitized solar cell (DSSC) for ubiquitous sensor network (USN) applications. The charge pump with a luminance-controlled oscillator regulates the load impedance of the DSSC to track the maximum power point (MPP) under various light intensities. The low drop-out regulator with a hysteresis comparator supplies intermittent power pulses that are wide enough for USN to communicate with a host transponder even under dim light conditions. With MPP tracking, approximately 50% more power is harvested over a wide range of light intensity. The power management system fabricated using $0.13{\mu}m$ CMOS technology works with DSSC to provide power pulses of $36{\mu}A$. The duration of pulses is almost constant around $80{\mu}s$ (6.5 nJ/pulse), while the pulse spacing is inversely proportional to the light intensity.

Classification and consideration for the risk management in the planning phase of NPP decommissioning project

  • Gi-Lim Kim;Hyein Kim;Hyung-Woo Seo;Ji-Hwan Yu;Jin-Won Son
    • Nuclear Engineering and Technology
    • /
    • 제54권12호
    • /
    • pp.4809-4818
    • /
    • 2022
  • The decommissioning project of a nuclear facility is a large-scale process that is expected to take about 15 years or longer. The range of risks to be considered is large and complex, then, it is expected that various risks will arise in decision-making by area during the project. Therefore, in this study, the risk family derived from the Decommissioning Risk Management (DRiMa) project was reconstructed into a decommissioning project risk profile suitable for the Kori Unit 1. Two criteria of uncertainty and importance are considered in order to prioritize the selected 26 risks of decommissioning project. The uncertainty is scored according to the relevant laws and decommissioning plan preparation guidelines, and the project importance is scored according to the degree to which it primarily affects the triple constraints of the project. The results of risks are divided into high, medium, and low. Among them, 10 risks are identified as medium level and 16 risks are identified as low level. 10 risks, which are medium levels, are classified in five categories: End state of decommissioning project, Management of waste and materials, Decommissioning strategy and technology, Legal and regulatory framework, and Safety. This study is a preliminary assessment of the risk of the decommissioning project that could be considered in the preparation stage. Therefore, we expect that the project risks considered in this study can be used as an initial data for reevaluation by reflecting the detail project progress in future studies.

임베디드 시스템을 위한 개선된 예측 동적 전력 관리 방법 (An Improved Predictive Dynamic Power Management Scheme for Embedded Systems)

  • 김상우;황선영
    • 한국통신학회논문지
    • /
    • 제34권6B호
    • /
    • pp.641-647
    • /
    • 2009
  • 본 논문은 임베디드 시스템에서 불필요한 전력 소모를 감소하기 위해 개선된 예측 동적 전력 관리 구조와 태스크 스케줄링 알고리듬을 제안한다. 제안된 알고리듬은 불필요한 전력 소모를 최소화하기 위해 미리 스케줄링을 한다. 제안된 예측 동적 전력 관리는 수행 오버 헤드를 경감하기 위해서 스케줄링 라이브러리를 제공한다. 실험 결과 제안된 알고리듬은 동적 전력 관리를 적용한 LLF 알고리듬과 비교하여 평균 22.3% 전력 소모 감소를 보인다.

선박 보조전원을 위한 저가형 하이브리드 연료전지 시스템 적용 타당성 연구 (A Feasibility Study of Low-Cost Hybrid Fuel-Cell System for Ship Auxiliary Power)

  • 양근령;안상용;추진훈
    • 신재생에너지
    • /
    • 제9권4호
    • /
    • pp.3-12
    • /
    • 2013
  • This paper proposes the hybrid fuel cell system that can solve disadvantages of existing fuel cell system and ensure high reliability and high stability. The system consists of PEM fuel cell, Ni-MH battery and power management system. In this system, when the power provided from the fuel cell is higher than the load power, the extra energy may be used to charge the Ni-MH battery. When the fuel cell can not provide enough energy to the load, the shortage of energy will be supplied by the Ni-MH battery. Experimental results show that the output voltage is regulated well during load variations. Also, high system efficiency is achieved.

에어컨부하 직접 제어시스템 실용화 연구 (Direct Load Control System for Air-conditioner)

  • 고상천;이상윤;김명수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 G
    • /
    • pp.3051-3053
    • /
    • 1999
  • In recent years, it becomes a worldwide trend that the power utilities focus their attention to Demand Side Management. Increasing Electric power consumption, they adopt a direct load management to accomplish low cost and stability of electric supply. Following this trend, KEPCO is researching a Direct Load Control System for Air Conditioner. This Paper presents the development results of the Direct Load Control System to Control electric power consumption of Conditioner in summer period this year.

  • PDF

Long range-based low-power wireless sensor node

  • Komal Devi;Rita Mahajan;Deepak Bagai
    • ETRI Journal
    • /
    • 제45권4호
    • /
    • pp.570-580
    • /
    • 2023
  • Sensor nodes are the most significant part of a wireless sensor network that offers a powerful combination of sensing, processing, and communication. One major challenge while designing a sensor node is power consumption, as sensor nodes are generally battery-operated. In this study, we proposed the design of a low-power, long range-based wireless sensor node with flexibility, a compact size, and energy efficiency. Furthermore, we improved power performance by adopting an efficient hardware design and proper component selection. The Nano Power Timer Integrated Circuit is used for power management, as it consumes nanoamps of current, resulting in improved battery life. The proposed design achieves an off-time current of 38.17309 nA, which is tiny compared with the design discussed in the existing literature. Battery life is estimated for spreading factors (SFs), ranging from SF7 to SF12. The achieved battery life is 2.54 years for SF12 and 3.94 years for SF7. We present the analysis of current consumption and battery life. Sensor data, received signal strength indicator, and signal-to-noise ratio are visualized using the ThingSpeak network.

전압 변동 보상항을 이용한 직류 마이크로그리드의 에너지 관리 기법 (Energy Management Method of DC Microgrids by Using Voltage Compensation Term)

  • 고병선;이기영;김석웅;김래영
    • 전력전자학회논문지
    • /
    • 제23권5호
    • /
    • pp.328-335
    • /
    • 2018
  • An energy management method of DC microgrids using voltage compensation term is proposed in this study. Droop control is often implemented to operate the DC microgrid. However, the droop control necessarily generates voltage variation. Energy flow is also difficult to control because the droop control mainly focuses on proportional load sharing. To solve these problems, the voltage compensation term based on the low-bandwidth communication is used to determine the operating band of the converter. Energy management and voltage variation minimization can be achieved by judging the operating band according to the magnitude of voltage compensation term. The validity of the proposed method is verified by simulation and experiments.