• Title/Summary/Keyword: Low Mode

Search Result 3,306, Processing Time 0.038 seconds

Study of Absorbed Dose and Effective Dose for Prostate Cancer Image Guided Radiation Therapy using kV Cone Beam Computed Tomography (kV Cone Beam Computed Tomography (CBCT)를 이용한 전립선암 영상유도방사선치료 시 흡수선량 및 유효선량에 관한 고찰)

  • Na, Jong-Eok;Lee, Do-Geun;Kim, Jin-Soo;Baek, Geum-Mun;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.67-74
    • /
    • 2009
  • Purpose: To evaluate the results of absorbed and effective doses using two different modes, standard mode (A-mode) and low-dose mode (B-mode) settings for prostate cancer IGRT from CBCT. Materials and Methods: This experimental study was obtained using Clinac iX integrated with On Board Imager (OBI) System and CBCT. CT images were obtained using a GE Light Speed scanner. Absorbed dose to organs from ICRP recommendations and effective doses to body was performed using A-mode and B-mode CBCT. Measurements were performed using a Anderson rando phantom with TLD-100 (Thermoluminescent dosimeters). TLD-100 were widely used to estimate absorbed dose and effective dose from CBCT with TLD System 4000 HAWSHAW. TLD-100 were calibrated to know sensitivity values using photon beam. The measurements were repeated three times for prostate center. Then, Evaluations of effective dose and absorbed dose were performed among the A-mode and B-mode CBCT. Results: The prostate absorbed dose from A-mode and B mode CBCT were 5.5 cGy 1.1 cGy per scan. Respectively Effective doses to body from A mode and B-mode CBCT were 19.1 mSv, 4.4 mSv per scan. Effective dose from A-mode CBCT were approximately 4 times lower than B-mode CBCT. Conclusion: We have shown that it is possible to reduce the effective dose considerably by low dose mode(B-mode) or lower mAs CBCT settings for prostate cancer IGRT. Therefore, we should try to select B-mode or low condition setting to decrease extra patient dose during the IGRT for prostate cancer as possible.

  • PDF

Fast Mode Decision Algorithm for H.264 using Mode Classification (H.264 표준에서 모드 분류를 이용한 고속 모드결정 방법)

  • Kim, Hee-Soon;Ho, Yo-Sung
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.44 no.3
    • /
    • pp.88-96
    • /
    • 2007
  • H.264 is a new international video coding standard that can achieve considerably higher coding efficiency than conventional standards. Its coding gain has been achieved by employing advanced video coding methods. Specially, the increased number of macroblock modes and the complex mode decision procedure using the Lagrangian optimization are the main factors for increasing coding efficiency. Although H.264 obtains improved coding efficiency, it is difficult to do an real-time encoding because it considers all coding parameters in the mode decision procedure. In this paper, we propose a fast mode decision algorithm which classifies the macroblock modes in order to determine the optimal mode having low complexity quickly. Simulation results show that the proposed algorithm can reduce the encoding time by 34.95% on average without significant PSNR degradation or bit-rate increment. In addition, in order to show the validity of simulation results, we set up a low boundary condition for coding efficiency and complexity and show that the proposed algorithm satisfies the low boundary condition.

Evaluation of Skin Dose and Image Quality on Cone Beam Computed Tomography (콘빔CT 촬영 시 mAs의 변화에 따른 피부선량과 영상 품질에 관한 평가)

  • Ahn, Jong-Ho;Hong, Chae-Seon;Kim, Jin-Man;Jang, Jun-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose: Cone-beam CT using linear accelerator attached to on-board imager is a image guided therapy equipment. Because it is to check the patient's set-up error, correction, organ and target movement. but imaging dose should be cause of the secondary cancer when taking a image. The aim of this study is investigation of appropriate cone beam CT scan mode to compare and estimate the image quality and skin dose. Materials and Methods: Measurement by Thermoluminescence dosimeter (TLD-100, Harshaw) with using the Rando phantom are placed on each eight sites in seperately H&N, thoracic, abdominal section. each 4 methods of scan modes of are measured the for skin dose in three time. Subsequently, obtained average value. Following image quality QA protocol of equipment manufacturers using the catphan 504 phantom, image quality of each scan mode is compared and analyzed. Results: The results of the measured skin dose are described in here. The skin dose of Head & Neck are measured mode A: 8.96 cGy, mode B: 4.59 cGy, mode C: 3.46 cGy mode D: 1.76 cGy and thoracic mode A: 9.42 cGy, mode B: 4.58 cGy, mode C: 3.65 cGy, mode D: 1.85 cGy, and abdominal mode A: 9.97 cGy, mode B: 5.12 cGy, mode C: 4.03 cGy, mode D: 2.21 cGy. Approximately, dose of mode B are reduced 50%, mode C are reduced 60%, mode D are reduced 80% a point of reference dose of mode A. the results of analyzed HU reproducibility, low contrast resolution, spatial resolution (high contrast resolution), HU uniformity in evaluation item of image quality are within the tolerance value by recommended equipment manufacturer in all scan mode. Conclusion: Maintaining the image quality as well as reducing the image dose are very important in cone beam CT. In the result of this study, we are considered when to take mode A when interested in soft tissue. And we are considered to take mode D when interested in bone scan and we are considered to take mode B, C when standard scan. Increasing secondary cancer risk due to cone beam CT scan should be reduced by low mAs technique.

  • PDF

The Pigrailing and The Loss Analysis of low loss LiNbO$_3$ Optical Waveguide with Fiber-to-fiber Insetion Loss<6dB (Total Fiber-to-fiber Insertion Loss가 <6dB 인 Ti:$LiNbO_3$ 과도파로 Pigtailing 및 손실분석)

  • 김성구;박계춘;조재철
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.7
    • /
    • pp.557-564
    • /
    • 1998
  • A low loss x-cut $LiNbO_3$optical waveguide was fabricated by Yi in-diffusion, and the properties of guided-mode and the total insertion loss of the pigtailed waveguide with polarization maintaining fiber(PMF) were measured at optical wavelength 1550nm. for forming the waveguides, the parameters of diffusion, Ti thickness, waveguide line-width, length, diffusion temperature, time and atmosphere were set $1400{\AA}$, $8{\mu}m$, 3.3cm, $1050^{\circ}C$, 8 hours and wet bubbled oxygen, respectively. And then after the polishing and piatailing, it showed that the total insertion loss was -4.1dB for TM mode, -5.5dB for TE mode, and mode size, that is, the horizontal/ vertical size were $13.8{\mu}m/18{\mu}m$ for TM mode, $9.6{\mu}m/6.5{\mu}m$ for TE mode.

  • PDF

Design of a Pump-Turbine Based on the 3D Inverse Design Method

  • Chen, Chengcheng;Zhu, Baoshan;Singh, Patrick Mark;Choi, Young-Do
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.1
    • /
    • pp.20-28
    • /
    • 2015
  • The pump-turbine impeller is the key component of pumped storage power plant. Current design methods of pump-turbine impeller are private and protected from public viewing. Generally, the design proceeds in two steps: the initial hydraulic design and optimization design to achieve a balanced performance between pump mode and turbine mode. In this study, the 3D inverse design method is used for the initial hydraulic impeller design. However, due to the special demand of high performance in both pump and reverse mode, the design method is insufficient. This study is carried out by modifying the geometrical parameters of the blade which have great influence and need special consideration in obtaining the high performance on the both modes, such as blade shape type at low pressure side (inlet of pump mode, outlet of turbine mode) and the blade lean at blade high pressure side (outlet of pump mode, inlet of turbine mode). The influence of the geometrical parameters on the performance characteristic is evaluated by CFD analysis which presents the efficiency and internal flow results. After these investigations of the geometrical parameters, the criteria of designing pump-turbine impeller blade low and high sides shape is achieved.

Power consumption evaluation of Set-top box mode transition scheme considering passive stand-by mode (수동대기모드를 고려한 셋톱박스 모드전환 기술의 에너지 절감 성능 분석)

  • Kim, Yong-Ho;Kim, Hoon
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.10 no.4
    • /
    • pp.135-142
    • /
    • 2011
  • This paper proposes a performance evaluation method for power consumption of set-top box (STB) stand-by mode transition schemes. A stand-by mode transition scheme characterizes the timing of mode transition. The timing of mode transition affects the duration of stand-by mode operation, and the power consumptions of STB as well. Recently a fast stand-by mode transition scheme (FMT) has been proposed based on user input for selecting the device to be connected to TV. In this paper, we evaluate power consumption of FMT and a conventional mode transition scheme. For the computation of the duration of stand-by mode operation, the user input events are modeled as Poisson process. Simulation results based on the modeling reveals that the proposed scheme is more effective in power saving than the conventional scheme by up to 30%.

  • PDF

Ultra-Low-Power Differential ISFET/REFET Readout Circuit

  • Thanachayanont, Apinunt;Sirimasakul, Silar
    • ETRI Journal
    • /
    • v.31 no.2
    • /
    • pp.243-245
    • /
    • 2009
  • A novel ultra-low-power readout circuit for a pH-sensitive ion-sensitive field-effect transistor (ISFET) is proposed. It uses an ISFET/reference FET (REFET) differential pair operating in weak-inversion and a simple current-mode metal-oxide semiconductor FET (MOSFET) translinear circuit. Simulation results verify that the circuit operates with excellent common-mode rejection ability and good linearity for a single pH range from 4 to 10, while only 4 nA is drawn from a single 1 V supply voltage.

  • PDF

A Study on the Modal Analysis of Suspension Assembly by Finite Element Method (유한요소법에 의한 서스펜션 에셈블리의 모드해석에 관한 연구)

  • 김광식;오재응;조준호;최상렬
    • Journal of KSNVE
    • /
    • v.2 no.3
    • /
    • pp.223-230
    • /
    • 1992
  • Vibration problems in the Hard Disk Drive which is magnetic recording device have been raised gradually while HDD is required high density and low access time. As a typical thing, lateral bending or sway mode of supension causes tracking error, and therefore it is necessary to identify the accurate vibration characteristics of that mode. In this study, as the solution of vibration problem, decoupling sway mode and vicinity mode is dealt with. Shifting sway mode to high frequency region is studied.

  • PDF

Hysteresis and Mode Transition in Electrodeless Fluorescent Lamp (무전극 램프에서의 히스테리시스와 모드 변환)

  • Lee, Joo-Ho;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.453-453
    • /
    • 2007
  • Electrodeless fluorescent lamp exhibit two modes of operation: a low density mode in which the power is capacitively coupled to the plasma and which is known as the E-mode, and a higher density mode which is an inductive discharge known as the H-mode. The transition between these two(E to H) mode exhibits hysteresis. It is observed that transition currents change at different frequencies and hysteresis exists not only between the starting and minimum maintaining currents of the electromagnetic mode (H mode) discharge but also between the starting and minimum maintaining currents of the electrostatic mode (E mode) discharge. Hysteresis effect can be important role in dimming system.

  • PDF

Changes in the gas chromatographic sensitivity with its analytical setting: Comparison of TDU and loop-injection system for the analysis of sulfur compounds (GC 분석 시스템의 설정과 그에 따른 감도의 차이: 열탈착 방식 대비 루프주입방식에 의한 황성분의 분석)

  • Kim, Ki-Hyun;Choi, Y.J.;Kim, S.C.
    • Analytical Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.66-73
    • /
    • 2005
  • In this study, we investigated the gas chromatography (GC) and pulsed flame photometric detection (PFPD) system for the analysis of four major reduced S compounds including hydrogen sulfide ($H_2S$); methyl mercaptan ($CH_3SH$); dimethyl sulfide (DMS); and dimethyl disulfide (DMDS) contained in environmental samples. To analyze these compounds in high concentration range (above ppb level), we developed a high mode analytical setting with the loop-injection system. By contrast, we also established a low mode setting for the analysis of low concentration samples (ppt-level samples from ambient air) by the combination with thermal desorption unit (TDU). Comparative analysis of both settings revealed that relative detection properties of four S compounds are systematic enough. The results of high mode analysis indicated that the patterns were systematic among S compounds: $H_2S$ exhibited the lowest sensitivity, while DMDS showed the strongest one. The results were also compared in terms of sensitivity reductions for all compounds by dividing slope ratios between low and high mode system. Although low mode system exhibited significant reductions on the order of a few tens times, their detection characteristics were highly consistent as it was shown in the high mode setting. To learn more about absolute and relative relations between two different modes of S analysis, future studies may have to be directed to cover more complicated nature of GC/PFPD performance.