• Title/Summary/Keyword: Low Mode

Search Result 3,311, Processing Time 0.031 seconds

Simplistic QA for an Enhanced Dynamic Wedge using the Reversed Wedge Pair Method (역방향 조사방식을 통한 동적쐐기의 품질관리)

  • Lee Jeong Woo;Hong Semie;Suh Tae Suk
    • Progress in Medical Physics
    • /
    • v.15 no.3
    • /
    • pp.161-166
    • /
    • 2004
  • A simplistic quality assurance (QA) method was designed for a Linac built-in enhanced dynamic wedge (EDW), which can be utilized to make wedged beam distributions. For the purpose of implementing the EDW symmetry QA, a film dosimetry system, low speedy dosimetry film, film densitometer and 3D RTP system were used, and the films irradiated by means of a 60$^{\circ}$ Reversed wedge pair (REWP) method. The profiles were then analyzed in terms of their symmetries, including partial treatment, which is the case of stopping it abruptly during EDW irradiation, and the measured and calculated values compared using the Cad Plan Golden Segmented Treatment Table (Golden STT). The result of this experiment was in good agreement, within 1 %, of the 'reversed wedge pair counterbalance effect'. For the QA of the effective wedge factor (EWF), the authors measured EWFs in relation to the 10$^{\circ}$, 15$^{\circ}$, 20$^{\circ}$, 25$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$ and 60$^{\circ}$ EDW, which were compared with the calculated values using the correction factor derived from the Golden STT and the log files produced automatically during the process of EDW irradiation. By means of this method it was capable of check up the safety of effective wedge factor without any other dosimetry system. The EDW QA was able to be completed within 1 hour from irradiation to analysis as a consequence of the simplified QA procedure, with maximized effectiveness. Unlike the metal wedge system, the EDW system was heavily dependent on the dose rates and jaw movements; therefore, its features could potentially cause inaccuracy. The frequent simplistic QA for the EDW is essential, and could secure against the flaw of dynamic treatment that uses the EDW.

  • PDF

A Study on Recovery from Potentially Lethal Damage Induced by $\gamma-Irradiation$ in Plateau-phase Vero Cells in vitro (평형기의 Vero세포계에서 방사선($\gamma$-선) 조사 후 발생한 잠재치사 손상의 회복에 관한 연구)

  • Kim, Il-Han;Choi, Eun-Kyung;Ha, Sung-Whan;Park, Charn-Il;Cha, Chang-Yong
    • Radiation Oncology Journal
    • /
    • v.6 no.1
    • /
    • pp.1-11
    • /
    • 1988
  • Recovery from potentially lethal damage (PLDR) after irradiation was studied in plateau-phase culture of Vero cells in vitro. Unfed plateau-phase cells were irradiated with dose of 1 to 9Gy using Cs-137 irradiator. Cells then were incubated again and left in situ for 0, 1, 2, 3, 4, 5, 6, and 24 hours and then were trypsinized explanted, and subcultured in fresh RPMI-1640 media containing $0.33\%$ agar. Cell survival was measured by colony forming ability. An adequate number of heavily irradiated Vero cells were added as feeder cells to make the total cell number constant in every culture dish. As the postirradiation in situ incubation time increased, surviving fraction increased by PLDR. The rate of PLDR was so rapid that increased surviving fraction reached saturation level at 2 to 4 hours after in situ incubation. As the radiation dose increased, the rate of PLDR fastened and the magnitude of increased surviving fraction at saturation level by PLOR also increased. In analysis of cell survival curve fitted to the linear-quadratic model, the linear inactivation coefficient $(\alpha)$ decreased largely and reached nearly to zero but the quadratic inactivation coefficient $(\beta)$ increased minimally by increment of postirradiation in situ incubation time. So PLDR mainly affected the damage expressed as $\alpha$, In the multitarget model, significant change was not obtained in $D_0\;but\;in D_q$. Therefore, shoulder region in cell survival curve was mainly affected by PLDR and terminal slope was not influenced at all. And dose-modifying factor by PLDR was relatively higher in shoulder region, that is, in low dose area below 3 Gy.

  • PDF

Knowledge and Performance of Universal Precautions by Nursing Students (일부 간호대학생의 혈액매개질환 예방 지침에 대한 지식과 실천 정도)

  • 김경미;김민아;정여숙;김남초
    • Journal of Korean Academy of Nursing
    • /
    • v.29 no.4
    • /
    • pp.929-939
    • /
    • 1999
  • The purpose of this study was to identify knowledge of universal precautions and its performance in practice. The research was conducted from November 2 to 30, 1998. A total 515 student nurses ; 249 from a baccalaureate nursing college and 266 from second and third year of a 3-year community nursing college were surveyed. The results are as following : 1. The average score for universal precautions knowledge was 270.41$\pm$19.43/300(range 150-300). The results showed that 99.2% of students avoid injury from used needles, 98.6% answered that they always wash their hands if they had contact with the patient's blood and they always dispose of used needles in special collectors (97.7%) for needles. But, 39.2% responsed that they dispose of used needles after recapping them. 2. The average score for universal precautions knowledge of the senior students in the 4-year college was the highest (277.65$\pm$13.99). 3. The average score for the performance of universal precautions knowledge was 53.18 $\pm$5.91(range 14-70). The items : ‘I cautiously avoid injury from the used needles’(4.92$\pm$0.33), ‘I always wash my hands if there has been contact with the patient's blood’(4.91$\pm$0.34), and ‘I always disposed of used needles in the appropriate collector’(4.89$\pm$0.42) showed the highest performance. However ‘I always dispose of used needles after recapping them’(2.19$\pm$1.39) and ‘I always use protection goggles when in danger of contamination’(2.19$\pm$1.20) showed low performance level. 4. The highest average score for universal precautions performance was shown among the second year students in 3-year nursing college (54.19$\pm$6.92) between the groups. It showed that the level of the universal precautions performance was higher for those who had education on university precautions prior to performance of the universal precautions than for those without any prior education. 5. The percentage of students who reported the experience of direct contact with patients' blood and/or body fluids was 42.30%. The experience of direct contact with blood and/or body fluids of the educational group was significantly higher than those were not educated. 6. The most frequent cause of the direct contact was ‘needle pricking and/or skin cut’(63.04%). The most frequent substance with which the students contact was ‘blood’(59.85%). The majority of the sample had answered that the mode of contamination was ‘unknown’(63.54%). The majority of the sample answered that strategies used after contamination included ‘washing with soap’(33.61%). Reviewing the chart of patients or asking other health professionals(28.85%). 7. The number of students who had the experience of a needle stick and/or skin cut was 145(28.16%). The clinical practice places where the incidents occurred were mainly in the internal medicine unit (45.07%) and the surgical unit (31.92%) followed by the intensive care unit and the emergency unit in order. The experience of a needle stick and/or skin cut happened during on intra-muscular injection 47.34% and intravenous injection 21.81%. The causes of the needle stick and/or skin cut were ‘putting the needle cap back on 77(35.81%)’. The number of students who took an appropriate post management blood test and/or vaccination was 27(18.62%). 8. The Pearson Correlation Coefficient between the knowledge of universal precautions and performance of universal precautions in practice showed a positive correlation.

  • PDF

Improved Device Performance Due to AlxGa1-xAs Barrier in Sub-monolayer Quantum Dot Infrared Photodetector

  • Han, Im Sik;Byun, Young-Jin;Lee, Yong Seok;Noh, Sam Kyu;Kang, Sangwoo;Kim, Jong Su;Kim, Jun Oh;Krishna, Sanjay;Ku, Zahyun;Urbas, Augustine;Lee, Sang Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.298-298
    • /
    • 2014
  • Quantum dot infrared photodetectors (QDIPs) based on Stranski-Krastanov (SK) quantum dots (QDs) have been widely explored for improved device performance using various designs of heterostructures. However, one of the biggest limitations of this approach is the "pancake" shape of the dot, with a base of 20-30 nm and a height of 4-6 nm. This limits the 3D confinement in the quantum dot and reduces the ratio of normal incidence absorption to the off-axis absorption. One of the alternative growth modes to the formation of SK QDs is a sub-monolayer (SML) deposition technique, which can achieve a much higher density, smaller size, better uniformity, and has no wetting layer as compared to the SK growth mode. Due to the advantages of SML-QDs, the SML-QDIP design has attractive features such as increased normal incidence absorption, strong in-plane quantum confinement, and narrow spectral wavelength detection as compared with SK-DWELL. In this study, we report on the improved device performance of InAs/InGaAs SML-QDIP with different composition of $Al_xGa1-_xAs$ barrier. Two SML-QDIPs (x=0.07 for sample A and x=0.20 for sample B) are grown with the 4 stacks 0.3 ML InAs. It is investigated that sample A with a confinement-enhanced (CE) $Al_{0.22}Ga_{0.78}As$ barrier had a single peak at $7.8{\mu}m$ at 77 K. However, sample B with an $Al_{0.20}Ga_{0.80}As$ barrier had three peaks at (${\sim}3.5{\mu}m$, ${\sim}5{\mu}m$, ${\sim}7{\mu}m$) due to various quantum confined transitions. The measured peak responsivities (see Fig) are ~0.45 A/W (sample A, at $7.8{\mu}m$, $V_b=-0.4V$ bias) and ~1.3 A/W (sample B, at $7{\mu}m$, $V_b=-1.5V$ bias). At 77 K, sample A and B had a detectivity of $1.2{\times}10^{11}cm.Hz^{1/2}/W$ ($V_b=-0.4V$ bias) and $5.4{\times}10^{11}cm.Hz^{1/2}/W$ ($V_b=-1.5V$ bias), respectively. It is obvious that the higher $D^*$ of sample B (than sample A) is mainly due to the low dark current and high responsivity.

  • PDF

Effects of Pine Needle Extract Oil on Blood Glucose and Serum Insulin Levels in db/db Mice (2형 당뇨 마우스에서 솔잎 추출용액의 경구투여가 혈당조절에 미치는 영향)

  • Kim, Mi-Joung;Ahn, Jin-Hong;Choi, Kang-Ho;Lee, Yun-Hak;Woo, Gyeong-Jin;Hong, Eun-Kyung;Chung, Young-Shin
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.35 no.3
    • /
    • pp.321-327
    • /
    • 2006
  • This study was performed to investigate the hypoglycemic effect of pine needle extract oil against type 2 diabetes. Six-week-old male C57BL/Ks(db/db) mice were divided into four groups : negative control, pine needle extract oil low dose, high dose and positive control groups, which fed daily for 6 weeks with corn oil, pine needle extract oil 112.5 mg/kg, 450 mg/kg or metformin (150 mg/kg ), respectively. The oral administration of the pine needle extract oil resulted in the significant and dose-dependent decreases of blood glucose levels in comparison with corn oil treatment. The levels of HbAlc showed a tendency of the decrease by the high dose treatment of the pine needle extract oil and were positively correlated with blood glucose levels (r=0.5046, p=0.0023) . However, the levels of serum insulin and C-peptide were not affected by pine needle extract oil or metformin treatments. The levels of serum leptin, which is related with the insulin sensitivity, showed a tendency of the increases by pine needle extract oil treatment and were negatively correlated to blood glucose levels (r=-0.4754, p=0.0052). In conclusion, these results suggest that the pine needle extract oil have a potential for the oral anti-hyperglycemic agent and the mode of action may be related with the improvement of the insulin sensitivity through blood leptin.

Geochemistry of the Kwanaksan alkali feldspar granite: A-type granite\ulcorner (관악산 알칼리 장석 화강암의 지구화학 : A-형 화강암\ulcorner)

  • S-T.Kwon;K.B. Shin;H.K. Park;S.A. Mertzman
    • The Journal of the Petrological Society of Korea
    • /
    • v.4 no.1
    • /
    • pp.31-48
    • /
    • 1995
  • The Jurassic Kwanaksan stock, so far known to be composed of biotite granite only, has the mineral assemblage of quartz+K-feldspar+plagioclase+biotite${\pm}$gernet. The lithology of the stock is classified as alkali feldspar granite by their mode and plagioclase compositions (An<5). Subsolvus feldspars, rather early crystallization of biotite, and shallow emplacement depth estimated from Q-Ab-Or diagram suggest hydrous nature of the magma, which contrasts with anhydrous A-type like geochemistry described below. Major and trace element compositions of the Kwanaksan stock are distinct from those of the adjacent Seoul batholith, suggesting a genetic difference between the two, The Kwanaksan stock shows geochemical characteristics similar to A-type granite in contrast to most other Mesozoic granites in Korea, in that it has high $SiO_2$(73~78wt%), $Na_2O+K_2O$, Ga(27~47 ppm). Nb(22~40 ppm), Y(48~95 ppm), Fe/Mg and Ga/Al, and low CaO(<0.51 wt%). Ba (8~75 ppm) and Sr(2~23 ppm). However, it has lower Zr and LREE and higher Rb(384~796 ppm) than typical A-type granite. LREE-depleted rare earth element pattern with strong negative Eu anomaly of previous studies is reinterpreted as representing source magma characteristics. The residual material during partial melting is not compatible with pyroxenes, amphibole or garnet, while significant amount of plagioclase is required. Similarity of geochemistry of the Kwanaksan stock to A-type granite suggests the origin of the stock has a chose relationship with that of A-type granite. These observations lead us to propose that the Kwanaksan stock was formed by partial melting of felsic source rock.

  • PDF

The Evaluation of Images with Various Filters in I-131 SPECT/CT (I-131 SPECT/CT에서 Ringing Artifact 감소를 위한 다양한 Filter값의 적용)

  • Kim, Ha Gyun;Kim, Soo Mee;Woo, Jae Ryong;Oh, So Won;Lee, Jae Sung;Kim, Yu Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.62-68
    • /
    • 2014
  • Purpose: After I-131 therapy, SPECT/CT is useful in identifying location of thyroid remnants and metastasis of thyroid cancers. An excessive uptake of thyroid leads to a ringing artifact in the SPECT images. The aim of this study is to investigate and suggest a proper post filters to remove ringing artifact and produce better image quality. Materials and Methods: A low-cost, customized thyroid-mimicking phantom, consisting of an acrylic bottle and a hollow sphere was used for SPECT/CT Discovery (GE Healthcare, USA). It was filled with I-131 solution. The ratio of hollow sphere to background were varied as 50:1, 200:1, 1000:1 and 4000:1. Acquired images were reconstructed by OSEM (2 iterations, 10 subsets) with and without Evolution (resolution recovery correction, GE). Three different post-filters were applied; Butterworth (cut off: 0.38 to 0.58 with intervals of 0.05), Hanning (cut off: 0.8 to 1 with intervals of 0.05) and Gaussian (FWHM: 3 to 5 with intervals of 0.5) filters. Contrast, background variability, air area variability, and full width half maximum (FWHM) were compared. Results: Higher contrasts were obtained from the SPECT images with Evolution than without Evolution. In the case of images without Evolution, image distortion such as star artifact was generated. For all sphere-to-background ratio, the Butterworth filter showed better constrasts and FWHMs than other two filters, but the ringing artifact was still generated in all studies except 50:1 and it was decreased as cutoff value was increased. The ringing artifact didn't appear with Hanning and Gaussian filters at all studies, however constrats and FWHMs with Gaussian was worse than Hanning filter. For the images having ringing artifacts, the background variability and air area variability were increased. Conclusion: In this study, we suggested that it is desirable to use Hanning filter when the ringing artifact is generated and to use Butterworth filter when ringing artifact is not generated in I-131 SPECT.

  • PDF

An Experimental Study on Flocculation and Settling of Fine-grained Suspended Sediments (부유물질의 응접작용 및 침전특성에 관한 실험적 연구)

  • Chu, Yong-Shik;Park, Yong-Ahn;Lee, Hee-Jun;Park, Kwang-Soon;Kweon, Su-Jae
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.4 no.1
    • /
    • pp.40-49
    • /
    • 1999
  • A laboratory flume experiment, using turbulence-generating acryl tank and natural sediments, was conducted to investigate the effects of salinity, concentration of suspended sediment, turbulence and clay minerals on the flocculation and settling of fine-grained suspended sediments. While experiments were run, a sequence of water samples were taken near the bottom of the tank to analyze the variations of size distribution and relative contents of clay minerals. The results of the salinity experiment indicate that median settling velocity ($W_{50}$) increases linearly with salinity. Different settling processes of suspended sediments under variable concentrations appear to be predictable, depending upon the range of the suspension concentration. At concentrations less than 200 mg/l, $W_{50}$ is rarely varied with concentration probably because of the individual--grain settling mode. In the range of 200 to 13,000 mg/l show $W_{50}$ and concentration a good relationship following an empirical formula: $W_{50}=0.45C^{0.44}$. This relationship, however, no longer holds in concentrations exceeding 13,000 mg/l; instead, a more or less reverse one is shown. This result suggests an effect of hindered settling. The turbulence effect is somewhat different from that of concentration. Turbulence accelerates the flocculation and settling susepended sediments at low concentration (200 mg/l), whereas at high concentration turbulence breaks floes down and impedes the settling. Size distribution of suspended sediments sampled near the bottom of the tank tend to be more negatively skewed and leptokurtic in turbulent conditions compared to those in static conditions. The clay mineral analysis from the sequential water samples shows that over time the content of smectite decreases most rapidly with illite remaining concentrated in suspension. This means that smectite, among other clay minerals, plays the most effective role in the flocculation of fine-grained sediment in saline water.

  • PDF

The Effect of Surface Defects on the Cyclic Fatigue Fracture of HEROShaper Ni-Ti rotary files in a Dynamic Model: A Fractographic Analysis (Fractographic 분석을 통한 HEROShaper 니켈티타늄 전동 파일의 피로파절에 미치는 표면결함의 역할)

  • Lee, Jung-Kyu;Kim, Eui-Sung;Kang, Myoung-Whai;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.2
    • /
    • pp.130-137
    • /
    • 2007
  • This in vitro study examined the effect of surface defects on cutting blades on the extent of the cyclic fatigue fracture of HEROShaper Ni-Ti rotary files using fractographic analysis of the fractured surfaces. A total of 45 HEROShaper (MicroMega) Ni-Ti rotary flies with a #30/.04 taper were divided into three groups of 15 each. Group 1 contained new HEROShapers without any surface defects. Group 2 contained HEROShapers with manufacturing defects such as metal rollover and machining marks. Croup 3 contained HEROShapers that had been clinically used for the canal preparation of 4-6 molars A fatigue-testing device was designed to allow cyclic tension and compressive stress on the tip of the instrument whilst maintaining similar conditions to those experienced in a clinic. The level of fatigue fracture time was measured using a computer connected the system. Statistical analysis was performed using a Tukey's test. Scanning electron microscopy (SEM) was used for fractographic analysis of the fractured surfaces. The fatigue fracture time between groups 1 and 2, and between groups 1 and 3 was significantly different (p<0.05) but there was no significant difference between groups 2 and 3 (p>0.05). A low magnification SEM views show brittle fracture as the main initial failure mode At higher magnification, the brittle fracture region showed clusters of fatigue striations and a large number of secondary cracks. These fractures typically led to a central region of catastrophic ductile failure. Qualitatively, the ductile fracture region was characterized by the formation of microvoids and dimpling. The fractured surfaces of the HEROShapers in groups 2 and 3 were always associated with pre-existing surface defects. Typically, the fractured surface in the brittle fracture region showed evidence of cleavage (transgranular) facets across the grains, as well as intergranular facets along the grain boundaries. These results show that surface defects on cutting blades of Ni-Ti rotary files might be the preferred sites for the origin of fatigue fracture under experimental conditions. Furthermore this work demonstrates the utility of fractography in evaluating the failure of Ni-Ti rotary flies.

Analysis and risk assessment of polycyclic aromatic hydrocarbons (PAHs) in seafood from oil contaminated bay (유류 오염지역의 수산물 중 다환방향족탄화수소류 (PAHs) 분석 및 위해평가)

  • Jeong, Ji-Yoon;Choi, Chan-Woong;Ryeom, Tai-Kyung;Cho, Kyoung-Hee;Park, Se-Ryung;Shin, Ho-Sang;Lee, Kwang-Ho;Lee, Hyo-Min
    • Analytical Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.187-195
    • /
    • 2010
  • To assess health risk for the intake among residents after the Hebei Spirit oil spill, 16 Polycyclic Aromatic Hydrocarbons (PAHs) in seafood samples from oil contaminated bay were determined by Gas Chromatography-Mass Spectrometry (GC-MSD) and samples were personally collected and purchased by residents. Samples were hydrolyzed with KOH and extracted with methylene chloride. The extracted solution were cleaned up using silica/florisil column and 16 PAHs were eluted by methylene chloride : n-hexane (1:9) mixture and determined by GC-MSD in Selected Ion Monitoring (SIM) mode. The mean recoveries for 16 PAHs ranged from 79% to 85%. The 16 PAHs levels in 126 samples ranged from 0.17 to $6.04\;{\mu}g$/kg and the TEQBaP (Toxic EQuivalents) levels in 126 samples were calculated using benzo(a)pyrene toxic equivalency factor for individual 16 PAHs and ranged from 0 to $0.91\;{\mu}gTEQ$/kg. The average Benzo(a)pyrene dietary exposure of residents was $5.5{\times}10^{-8}\;mg/kg$ bw/day and the average PAHs chronic dietary exposure was $1.3{\times}10^{-5}\;mg$ TEQ/kg bw/day. The margin of exposure (MOE) and the excess cancer risk and were $1.8{\times}10^6$ and $9.8{\times}10^{-8}$, respectively. Therefore, the assessment result was considered as low concern for health risk.