복합보온양생 방법이 극저온 조건하 플라이애시 치환 콘크리트의 온도이력에 미치는 영향 (The Effect of Heat Curing Methods on the Temperature History of the Fly Ash Concrete Subjected to Extremely Low Temperature)

  • 한민철;손호정
    • 한국건설순환자원학회논문집
    • /
    • 제7권3호
    • /
    • pp.85-90
    • /
    • 2012
  • In this study, temperature profile of the fly ash concrete were studied in accordance with the change of heating curing method combination for the slab concrete in order to develop efficient protection method of the concrete subjected to $-20^{\circ}C$. The slab concretes with the size of $1200mm{\times}600mm{\times}200mm$ were fabricated with W/B of 50% and exposed to $-20^{\circ}C$ for 7 days. Five different combinations of heat curing methods were applied to the slab concrete specimen; two combinations of heat supplying by electrical heater and surface heat insulation material such as polyethylene film and quadrupled layer bubble sheet based on heat enclosure installment; three combinations of heating coil embedment and surface heat insulation materials such as polyethylene film, sawdust and quadrupled layer bubble sheet based on heat enclosure installment. Test results showed that by applying both heating coil and bubble sheet and heat enclosure, the concrete exposed to $-20^{\circ}C$ can be effectively protected from early-age frost damage.

  • PDF

분체계 재료조합 및 석탄 가스화 용융 슬래그를 잔골재로 활용한 매스 콘크리트 수화열 저감 (Reducing Hydration Heat of Mass Concrete by Applying Combination of Powdered Materials and CGS as Fine Aggregate)

  • 박상원;한준희;한민철
    • 한국건축시공학회지
    • /
    • 제24권2호
    • /
    • pp.169-180
    • /
    • 2024
  • 본 연구는 분체계 재료조합 시멘트 및 CGS 잔골재 조합에 따른 콘크리트의 단열온도상승 시험결과를 통해 최적의 조합 비율을 도출하고, 이를 토대로 모의부재 시험 및 수화열 해석을 통하여 매스 콘크리트 구조물에서의 수화열 저감 성능에 대한 현장 적용성을 분석하였다. 분석결과 TBC+CGS 50%조합에서 콘크리트 중앙부와 표면부의 온도차이가 감소하며, 최고 온도 도달시간이 지연되어 시간경과에 따른 표면부 인장강도 증가로 온도응력에 따른 온도균열 발생을 저감시킬 수 있을 것으로 판단된다.

극저온 조건에서 보온양생 방법 변화에 따른 콘크리트의 초기동해 방지 (Prevention of Early Frost Damage of the Concrete under Severely Low Temperature according to Heat Curingmethods)

  • 한민철
    • 한국건축시공학회지
    • /
    • 제16권1호
    • /
    • pp.67-76
    • /
    • 2016
  • $-20^{\circ}C$이하의 극저온조건에서 타설되는 콘크리트는 초기동해 방지를 위해 적절한 급열을 포함한 보온양생이 이루어져야 하는데, 현재까지 국내에서 극저온조건의 효율적인 보온양생 방법이 제시된 경우가 드문 실정이다. 따라서 본 연구에서는 $-20^{\circ}C$의 극한조건에서 시공되는 콘크리트의 초기동해 방지를 위한 효율적인 보온양생방법을 제시하고자, 보온양생 재료의 조합 변화에 따른 콘크리트의 온도이력, 적산온도 및 코어강도 결과를 고찰하였다. 실험변수로서 보온양생방법 조합에 따라 기둥, 슬래브 및 벽체를 모사한 목업 시험체를 제작한 후, 단열, 가열 및 양자 병용방법을 적용하여 실험을 진행하였다. 연구결과에 따르면, 슬래브 부재의 경우 온도이력 및 적산온도 측정결과 4BS+열선조합, 벽체의 경우 가열양생+발열매트 그리고 기둥의 경우 EPS 단열재조합에서 3일 이내에 초기동해 방지에 요구되는 적산온도인 $45^{\circ}D{\cdot}D$를 상회하며 $0^{\circ}C$이하로 콘크리트 온도가 저하하지 않는 것으로 나타나 본 연구범위에서 최적의 조합으로 판단된다.

매스콘크리트의 파이프 쿨링 효과 (A Study on the Effect of Pipe Cooling in Mass-Concrete)

  • 윤승권;김은경;김래현;신치범
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 가을 학술발표회 논문집
    • /
    • pp.329-333
    • /
    • 1995
  • The usual methods for the temperature control of mass-concrete structures include the use of low-heat cement, pre-cooling, or pipe-cooling. In order to control the heat of hydration of mass-concrete structures such as massive pier or anchor block, and mat foundation, the pipe cooling method is widely acceptable for pratical use. In this paper, method of analysis using the Finite Element Method was applied to analyze the heat exchange on the field of three dimensional thermal conduction. The result of analysis Well agreed with experimentally measurement data by "KUMATANI". The method of this analysis will be used widely to control the heat of hydration by the pipe cooling in mass-concrete.-concrete.

  • PDF

해안매립지 하수처리시설물에 적용한 저발열시멘트 콘크리트의 내화학성 평가 (Chemical Resistance of Low Heat Cement Concrete Used in Wastewater Treatment Structures Built on Reclaimed Land)

  • 정용택;이병재;김윤용
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권7호
    • /
    • pp.113-119
    • /
    • 2019
  • 해안매립지에 건설되는 구조물은 해수로부터 유입되는 염소 및 황산염 이온 등의 화학적 침식에 의한 영향을 복합적으로 받는다. 염해는 콘크리트 내부의 철근을 부식시켜 구조물의 성능을 저하시킨다. 또한, 하수처리시설에서는 내부에서 발생되는 황산염에 의해 콘크리트가 열화되는 문제점을 가진다. 따라서 본 연구에서는 해안매립지에 건설되는 하수처리구조물에 적용할 수 있는 혼합형 저발열시멘트의 특성 및 내화학성을 평가하였다. 실험결과, 모든 배합조건에서 목표슬럼프 및 공기량을 모두 만족하였다. 동일 배합조건에서 LHC사용시 OPC 보다 슬럼프는 증가되고, 공기량은 감소하는 경향을 나타내었다. 압축강도 시험결과, 초기재령에서는 OPC의 강도발현이 빨랐으며, 28일 이후 LHC가 OPC보다 높은 강도를 나타내었다. 염소이온침투저항성 평가결과, LHC-B의 경우 56일 재령에서, "매우낮음" 단계의 염소이온침투저항성을 나타내 LHC의 내염해성을 확인하였다. 내화학성 평가 결과, 에폭시 처리 하지 않은 경우 LHC를 적용한 경우, OPC보다 약 18%정도 내화학성이 개선되는 것으로 나타났으며, 콘크리트 표면에 에폭시 공법 적용시 강도보존율이 95% 이상 확보 가능한 것으로 확인되었다.

3성분계 시멘트를 사용한 매스콘크리트의 시공사례 (An Application of the Mass Concrete Using Ternary Blended Cement)

  • 권영호;하재담;전성근;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.1229-1234
    • /
    • 2001
  • The bottom slab of Inchon LNG in-ground #213 tank is designed as a massive structure witch has a large depth and section. The purpose of this study is to determine the optimum mix design having good workability and low hydration heat for bottom slab concrete and to control the actual concrete quality in site. For this purpose, we select the optimum mix design used ternary blended cement(furnace slag cement+fly ash) and design factors. As test results of actual application, we have finish placing the bottom slab concrete of 23,180㎥ during 68hours with good success and obtain the good quality of fresh and hardened concrete including slump, air contents, no-segregation, compressive strength and low hydration heat in actual data. All test results are satisfied with our specifications for bottom slab concrete and we cut costs as the use of ternary blended cement and the reduction of placing hours.

  • PDF

저 분말도 포틀랜드 시멘트의 특성 (The characteristics of Low Blaine Cement)

  • 김재영;전준영;송종택
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표회 논문집(I)
    • /
    • pp.13-18
    • /
    • 1998
  • This experiments carried out in order to investigate decreasing of the hydration heat and physical characteristics of the low blaine OPC. The experiments results indicated hydration heat was reduced by about 15% in th low blaine OPC(2300$\textrm{cm}^2$/g). The Mini-slump value of the cement paste was significantly increased and viscosity of one was decreased as blaine value in OPC decrease.

  • PDF

저 분말도 슬래그를 사용한 슬래그 시멘트의 특성 (The Characteristics of Blastfurnace Slag Blended Cement with Low Blaine Slag Powder)

  • 변승호;최현국;김재영;송종택
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표회 논문집(I)
    • /
    • pp.19-24
    • /
    • 1998
  • In this study, blended cement with low blaine(2000, 3000$\textrm{cm}^2$/g) blast-furnace slag power by 10-70wt.% was investigated through the measurement hydration heat, physical properties. The experiment results indicated compressive strength was decreased as low blaine slag blended, but hydration heat was reduced significantly and flow of the cement paste was increased.

  • PDF

저열 시멘트 콘크리트의 건조수축 및 크리프 거동 평가 (Evaluation of Shrinkage and Creep Behavior of Low-Heat Cement Concrete)

  • 문재성;양근혁;김시준
    • 한국건축시공학회지
    • /
    • 제16권4호
    • /
    • pp.305-311
    • /
    • 2016
  • 개발된 저열 시멘트 콘크리트의 장기거동 특성인 비구속 건조수축과 크리프가 양생온도를 주요 변수로 측정하였다. 저열 콘크리트의 목표 압축강도인 42MPa를 고려하여 양생온도 5, 20, $40^{\circ}C$에서 물-결합재비는 각각 27.5, 30, 32.5%를 선택하였다. 콘크리트의 건조수축 변형률은 양생온도가 낮을수록 모세관 수 및 겔 공극수의 증발지연으로 인해 감소하는 경향을 보였다. 반면 크리프 변형률은 전이 온도 크리프의 발생으로 인하여 초기 양생온도가 낮은 실험체에서 높았다. 콘크리트 구조설계기준(KCI) 예측모델은 ACI 209 예측모델에 비해 실험결과와 잘 일치하였지만 개발된 저열 시멘트에 대한 보정계수의 제안이 필요하였다.

매스콘크리트 구조물에서의 시멘트 종류별 수화발열 특성 평가 (Evaluation of Thermal Characteristics in Association with Cement Types in Massive Concrete Structure)

  • 김상철;강석화;김진근
    • 콘크리트학회논문집
    • /
    • 제11권6호
    • /
    • pp.3-12
    • /
    • 1999
  • The larger, loftier and more highly strengthened the recent structures become, the greater attention is paid to the problem of thermal crack occurrence associate with hydration heat. As one of methods to solve the problem, a care has been taken to the improvement of construction such as the application of pre-cooling or pipe-cooling, adjustment of concrete block size, concrete placement timing, joint arrangement and so on. But it is expected that a proper selection of cement shall additionally contribute to the control of thermal cracks. In this study, thus, we selected 4 types of cements such as Type V for anti-sulphate, blast furnace cements (slag content of 45% and 65% respectively)and ternary blended low heat cement, and carried out mock-up tests. In every assigned time, temperatures and thermal stresses were measured and calculated from raw data. As a result of measurement, it was found that the magnitude of hydration heat is in order of blast furnace slag cement. Type V and ternary blended low heat cement. Results of thermal stresses were same as the order of temperature. In addition, thermal stresses calculated from the data of strain gauges showed almost similar to those measured from effective stress gauges only when strain values were adjusted properly in accordance with initial time of stress appearance. Theoretical results agreed well with the measured values comparatively, but showed slight differences. It is inferred that these differences shall be reduced if more tests capable of evaluating thermal characteristics of concrete are carried out.