• Title/Summary/Keyword: Low Emission Zone

Search Result 75, Processing Time 0.025 seconds

A Development of Environmental-friendly Burner with High Injection Velocity by Multi-staged Fuel-injection (환경친화형 연료분할-고속분사식 버너 개발)

  • Choo, Jae-Min;Ko, Young-Ki;Kim, Jong-Woo;Kim, Cheol-Min
    • 한국연소학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.148-155
    • /
    • 2005
  • In this study, Development of 300,000kcal/hr high velocity Injection burner with fuel multi-stage was performed using experiments. The characteristics of NOx emission in multi fuel/air staged combustor have been experimentally studied. The design concept of multi fuel/air staged combustor is creation of two separate flame, a primary flame is largest access air combustion and the secondary flame is complete combustion zone, where most of fuel bums. Experiments were performed on an industrial scale in a laboratory furnace and Liquefied Natural Gas(LNG) was used as primary and secondary fuels. Comparison of outlet NOx and outlet Temperature under various air rate and primary/ secondary fuel ratio was performed. The test demonstrated that NOx emission con be reduced by 70% in accordance with operating conditions.

  • PDF

Evaluation of Fracture Behavior of High Tension Steel by AE Amplitude Distribution (AE 진폭분포를 이용한 고장력강의 파괴특성평가)

  • Seo, Jeong-Won;Seok, Chang-Seong;Kim, Yeong-Jin;Park, Ji-U
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.5 s.98
    • /
    • pp.175-185
    • /
    • 1999
  • Acoustic emission(AE) measurement was carried out to evaluate the fracture behavior of high tension steel. Fracture toughness $K_{AE}$ could be determined reasonably by using the load value corresponding to an abrupt change of the accumulated AE counts AE emitted from the test specimens. AE characteristics of the base metal, the weld metal and the heat-affected zone could be distinguished using a constant value b which represented the AE amplitude distribution, Consequently the structure integrity can be evaluated by variation of the constant b at the load level. In addition it was found that AE signals due to crack growth have high amplitude but low rise time and duration.

  • PDF

The Evaluation of Mixed-welded SM 490A Steel by Acoustic Emission (1) (음향방출법에 의한 SM490A강의 복합용접성 평가 (1))

  • 이장규;우창기;박성완;김봉각;윤종희;인승현
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.170-173
    • /
    • 2002
  • The object of this study is to investigate the effect of compounded welding through the AE (Acoustic Emission) characteristics on static tensile test. This study was carried out a SM 490A, high tension steel using the low hydrogen type E4316 of electronic shield metal arc welding and compound wire of $CO_2$gas arc welding. $CO_2$welding, weak in the intensity of HAZ (Heat Affected Zone), can be improved by being combined with coated arc welding, Coated arc welding, weak in the intensity of the bead, can be improved by being combined with $CO_2$welding. Especially, electronic coated arc welding and $CO_2$welding complement the mechanical intensity of HAZ and the bead with each other. So, compounded welding increases the intensity in the special parts and enhances the quality of goods.

  • PDF

A Study of the Travel Factors of Truck for the Low Emission Zone (차량 운행제한 지역 설정을 위한 화물자동차 통행요인 분석)

  • Hahn, Jin-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.492-498
    • /
    • 2021
  • This study examined how the emissions of pollutants affect the volume of traffic of freight vehicles in the transport sector. Multiple regression analysis was conducted considering several variables, including population by region, area of urban district, GDP, and the number of businesses by industry, e.g., agriculture, forestry, fishery, manufacturing, wholesale, and retail. These variables differ according to the characteristics of the freight vehicles (industry, by the ton). Therefore, it is essential to fully consider the volume of traffic of the specific freight vehicles by region before implementing relevant programs and policies, such as specific restrictions on the operation of vehicles. Some specific areas, in which logistic centers are located have heavy freight traffic, and these centers deserve extra consideration. Thus, in this study, different regional factors that affect the traffic of freight vehicles should be considered before determining the areas that will be subject to restrictions on the operation of these vehicles.

A Study on Swirl Flow and Combustion Characteristics of Air Staged Low NOx Burner (다단 공기 공급 저 NOx 버너의 선회유동 및 연소특성에 관한 실험적 연구 - 다단공기공급에 의한 연소특성(I) -)

  • Shin, Myung-Chul;Ahn, Je-Hyun;Kim, Se-Won
    • Journal of the Korean Society of Combustion
    • /
    • v.8 no.1
    • /
    • pp.25-35
    • /
    • 2003
  • The objective of this research is to determine generally applicable design principles for the development of internally staged combustion devices. Utilizing a triple annulus combustor, the detailed combustion characteristics are studied. For this triple air staged combustor, the angular momentum weighted by it#s swirl number and air distribution ratio was observed to be the critical criteria of NOx emission. An internal recirculation zone which develops on the centerline of the flame immediately downstream of the burner entraps the fuel into a fuel rich eddy. Then sufficient heat must be transferred from the flame via radiation to the chamber heat transfer surfaces, such that the peak flame temperatures are suppressed when the second air is introduced. It is experimentally found out that the total NOx emission level in this type of burner is below 50ppm(3% Ref. O2) at optimum operating conditions.

  • PDF

A Study of $NO_x$ Reduction in Stage Combustion (단계적 연소의 $NO_x$ 저감에 대한 연구)

  • 채재우;전영남;이운영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.6
    • /
    • pp.1556-1571
    • /
    • 1993
  • Nitrogen oxides ($NO_x$) are air pollutants which are generated from the combustion of fossil fuels. Stage combustion is an effective method to reduce $NO_x$ emissions. The effects of $NO_x$ reduction by stage combustion in a pilot scale combustor(6.6kW) have been investigated using propane gas flames laden with NH$_{3}$ as Fuel-N. The results in this study are follows; (1) $NO_x$ emissions are dependent on the reducing environment of fuel-rich zone regardless of total air ratio. The maximum $NO_x$ reduction is at the stoichiometric ratio of 0.8 to 0.9 in the reducing zone. (2) $NO_x$ reduction is maximum when burnout air is injected at the point where the oxygen in reducing zone is almost consumed. (3) $NO_x$ reduction is dependent upon the temperature of reducing zone with best effect above 950.deg. C in the reducing zone. (4) The fuel stage combustion is more effective to reduce $NO_x$ formation in the wide range of stoichiometric ratio than two stage combustion. (5) The results of this study could be utilized mainly in a design strategy for low $NO_x$ emission from the combustion of high fuel-nitrogen in energy sources ratio than as an indication of the absolute levels of $NO_x$ which can be achieved by stage combustion techniques in large scale facilities.

An Experimental study on swirl flow and combustion characteristics of 3 staged low NOx burner applied with FGR and FIR (FGR 및 FIR을 적용한 3단 저 NOx 버너의 Swirl유동 및 연소특성에 관한 실험적 연구)

  • Shin, Myung-Chul;Kim, Se-Won;Cha, Hak-Ju
    • 한국연소학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.105-112
    • /
    • 2002
  • The objective of this research is to determine generally applicable design principles for the development of internally staged combustion devices. Utilizing a triple annulus combustor, air staged commercial propane flame configuration are studied. For this triple air staged combustor, the angular momentum weighted by it's swirl number and air distribution ratio was observed to be the critical criteria. An internal recirculation zone which develops on the centerline of the flame immediately downstream of the burner entraps the fuel into a fuel rich eddy. Then sufficient heat must he transferred from the flame via radiation to the chamber heat transfer surfaces, such that when the second air is introduced, peak flame temperatures are suppressed. It is experimentally found out that the total NOx emission level in this type of burner is lower than 0.75g/kg.

  • PDF

The Low $NO_{x}$ Characteristics of a Lean Premixed Gas Turbine Combustor (희박연소를 이용한 가스터빈 연소기의 저 $NO_{x}$ 특성)

  • Son, M.G.;Ahn, K.Y.;Kim, H.S.;Kim, Y.M.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.66-70
    • /
    • 2001
  • The combustion characteristics have been investigated to develop the low $NO_{x}$ gas turbine combustor. The lean premixed combustion technology was applied to reduce the $NO_{x}$ emission. Also, the conventional combustor was designed and tested for the baseline of low $NO_{x}$ combustor performance. The test was conducted at the condition of high temperature and ambient pressure. The combustion air which has the temperature of 500K were supplied to the combustor through the air preheater. The temperature and emissions of $NO_{x}$ and CO were measured at the exit of combustor. The premixing chamber can be operated very lean condition of equivalence ratio around 0.35. The $NO_{x}$ was decreased with decreasing the equivalence ration. The CO was decreased with decreasing the equivalence ratio, but the CO was increased with decreasing the equivalence ratio below 0.45. But, at the very lean condition of equivalence ratio below 0.35 both NOx and CO were increased because of the flame unstability. The $NO_{x}$ was decreased slightly and CO was increased with increasing inlet air flowrate. This results can be used to determine the size of combustor. The low $NO_{x}$ combustor has lower values of $NO_{x}$ and CO compared with conventional one. Consequently the performance of combustor shows the possibility of the application to the gas turbine system.

  • PDF

Study on Operating Characteristics for NOx Reduction in Ultra Low NOx Burner Combustion Using 80 kW Furnace (80 kW 초 저 NOx 단일 버너 연소로에서 NOx 감소를 위한 운전특성 연구)

  • Chae, Taeyoung
    • Clean Technology
    • /
    • v.26 no.3
    • /
    • pp.211-220
    • /
    • 2020
  • This experimental study investigates the design parameters to achieve ultra low NOx combustion of coal using a 80 kW capacity single-burner furnace. The influence of key design parameters such as SN, overall and burner-zone equivalence ratios, primary/secondary air ratio, overfire air (OFA) ratio were tested for a total of 81 cases. The results showed that weak swirl intensity of the burner leads to higher NOx emission whereas strong swirl intensity accompanies increased CO concentration desipte lower NOx emission. Therefore, finding an appropirate swirl intensity is essential for the burner design. Larger flow rate of secondary air increased NOx emission, whereas smaller flow rate stretches the flame and increased CO emission. The lowest NOx emission of 82 ppm (6% O2) was achieved at the optimal condition of the present burner deisgn. It is expected to furrther lower the NOx emission by introducing splitting the burner secondary air into three or four streams.

Theoretical Analysis on the Applications of the Double-Floor Ondol System (이중 바닥 온돌 시스템의 응용에 관한 이론적 분석)

  • Choi, Won-Ki;Lee, Kang-Young;Lee, Hyun-Geun;Suh, Seung-Jik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.5
    • /
    • pp.355-363
    • /
    • 2007
  • The Korean traditional 'Ondol' system has been a target for innovation to meet the requirements of sustainable domestic building and low carbon emission energy utilization. Simulation techniques provide designers and researchers with powerful tools to predict heating load and thermal behaviour of Ondol systems installed in various contexts. However, there are few studies on Ondol models, especially associated with multi-stories buildings of which type covers about 50% of Korean housing stock. In this study, we analyzed the double floor Ondol system on the multi-stories buildings using the ESP-r program. On the basis of the double floor Ondol system, we suggested the new modelling method that is composed of the Vent zone and Ondol zone. Using the this model, sensitivity analysis was carried out to refine the applicability of the model taking account of control conditions, constructions, air change and air flow network method and CFD analysis using the FLUENT. The air layer has enough temperature to use in heating zone. It is suggested that the simplicity of the model will allow building designers and mechanical engineers easily to implement scenario-based assessments of design options as well as control strategies. Later, we will simulate the real buildings and analyze the air distributions using the Fluent according to the various conditions.