• Title/Summary/Keyword: Low Dose and Low Dose Rate

Search Result 575, Processing Time 0.028 seconds

The Acceleration of Germination in Welsh Onion Seed Irradiated with the Low Dose ${\gamma}-ray$ Radiation (저선량 감마선 조사가 파종자의 발아에 비치는 영향)

  • Lee, Eun-Kyung;Kim, Jae-Sung;Lee, Young-Keun;Lee, Young-Bok
    • Korean Journal of Environmental Agriculture
    • /
    • v.17 no.4
    • /
    • pp.346-351
    • /
    • 1998
  • To investigate the hormetic effects of the low dose ${\gamma}-ray$ radiation on the germination rate, Welsh onion (Allium fistulosum L. cv. Eunchun and cv. Sukchangwoidae) seeds were irradiated at the dose of $0.5\;{\sim}24.0$ Gy with the ${\gamma}-ray$ radiation (Co-60). The germination rate of 'Eunchun' cultivar increased about 10% in the low dose ${\gamma}-ray$ irradiation group compared with that of the control. In the 'Sukchangwoidae' cultivar, the germination rate of the 4 Gy irradiation group increased 40% more than that of the control. Broadly, it seemed that the hormetic effects of the low-dose ${\gamma}-ray$ radiation were taken more promisingly in the uncultivated soil than in the fertile soil. The germination rate from the paper towel and filter paper based cultivation increased 10% and 16% more, respectively, in the 1 Gy irradiation group than that in the control group. And the electric conductivities of the above groups supposed to be taken hormetic effects of the ${\gamma}-ray$ radiation were lower than those of the control group. From the above results, it is suggested that the low dose ${\gamma}-ray$ radiation ranged from 1 Gy to 10 Gy could have the hormetic effects on the germination rate related characters in Welsh onion seeds.

  • PDF

Calculation of Dobe Distributions in Brachytherapy by Personal Microcomputer (Microcomputer를 이용한 근접조사 장치의 선량분포 계산)

  • Chu S. S.;Park C. Y.
    • Radiation Oncology Journal
    • /
    • v.2 no.1
    • /
    • pp.129-137
    • /
    • 1984
  • In brachytherapy, it is important to determine the positions of the radiation sources which are inserted into a patient and to estimate the dose resulting from the treatment. Calculation of the dose distribution throughout an implant is so laborious that it is rarely done by manual methods except for model cases. It is possible to calculate isodose distributions and tumor doses for individual patients by the use of a microcomputer. In this program, the dose rate and dose distributions are calculated by numerical integration of point source and the localization of radiation sources are obtained from two radiographs at right angles taken by a simulator developed for the treatment planning. By using microcomputer for brachytherapy, we obtained the result as following 1. Dose calculation and irradiation time for tumor could be calculated under one or five seconds after input data. 2. It was same value under$\pm2\%$ error between dose calculation by computer program and measurement dose. 3. It took about five minutes to reconstruct completely dose distribution for intracavitary irradiation. 4. Calculating by computer made remarkly reduction of dose errors compared with Quimby's calculation in interstitial radiation implantation. 5. It could calculate the biological isoffect dose for high and low dose rate activities.

  • PDF

In vitro Study of the Antagonistic Effect of Low-dose Liquiritigenin on Gemcitabine-induced Capillary Leak Syndrome in Pancreatic Adenocarcinoma via Inhibiting ROS-Mediated Signalling Pathways

  • Wu, Wei;Xia, Qing;Luo, Rui-Jie;Lin, Zi-Qi;Xue, Ping
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.10
    • /
    • pp.4369-4376
    • /
    • 2015
  • Background: To investigate in-vitro antagonistic effect of low-dose liquiritigenin on gemcitabine-induced capillary leak syndrome (CLS) in pancreatic adenocarcinoma via inhibiting reactive oxygen species (ROS)-mediated signalling pathways. Materials and Methods: Human pancreatic adenocarcinoma Panc-1 cells and human umbilical vein endothelial cells (HUVECs) were pre-treated using low-dose liquiritigenin for 24 h, then added into gemcitabine and incubated for 48 h. Cell viability, apoptosis rate and ROS levels of Panc-1 cells and HUVECs were respectively detected through methylthiazolyldiphenyl-tetrazoliumbromide (MTT) and flow cytometry. For HUVECs, transendothelial electrical resistance (TEER) and transcellular and paracellular leak were measured using transwell assays, then poly (ADP-ribose) polymerase 1 (PARP-1) and metal matrix proteinase-9 (MMP9) activity were assayed via kits, mRNA expressions of p53 and Rac-1 were determined through quantitative polymerase chain reaction (qPCR); The expressions of intercellular adhesion molecule 1 (ICAM-1), vascular cell adhesion molecule-1 (VCAM-1) and PARP-1 were measured via western blotting. Results: Low-dose liquiritigenin exerted no effect on gemcitabine-induced changes of cell viability, apoptosis rate and ROS levels in Panc-1 cells, but for HUVECs, liquiritigenin ($3{\mu}M$) could remarkably elevate gemcitabine-induced decrease of cell viability, transepithelial electrical resistance (TEER), pro-MMP9 level and expression of ICAM-1 and VCAM-1 (p<0.01). Meanwhile, it could also significantly decrease gemcitabine-induced increase of transcellular and paracellular leak, ROS level, PARP-1 activity, Act-MMP9 level, mRNA expressions of p53 and Rac-1, expression of PARP-1 and apoptosis rate (p<0.01). Conclusions: Low-dose liquiritigenin exerts an antagonistic effect on gemcitabine-induced leak across HUVECs via inhibiting ROS-mediated signalling pathways, but without affecting gemcitabine-induced Panc-1 cell apoptosis. Therefore, low-dose liquiritigenin might be beneficial to prevent the occurrence of gemcitabine-induced CLS in pancreatic adenocarcinoma.

High and Low Dose Folinic Acid, 5-Fluorouracil Bolus and Continuous Infusion for Poor-Prognosis Patients with Advanced Colorectal Carcinoma

  • Bano, Nusrat;Najam, Rahila;Mateen, Ahmed;Qazi, Faaiza
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.8
    • /
    • pp.3589-3593
    • /
    • 2012
  • Objective: Evaluation and assessment of response rate, duration and toxicity in patients subjected to 5-FU based chemotherapy. Background: The therapeutic ratio shifts with different 5FU/LV regimens and none yet serve as the internationally accepted Gold Standard. A bimonthly regimen of high dose leucovorin is reported to be less toxic and more effective than monthly low dose regimens. We here compare therapeutic responses and survival benefit of the two regimens in poor prognosis patients with advanced colorectal carcinoma. Patients and Methods: A total of 35 patients with histologically confirmed colorectal carcinoma were subjected to de Gramont and Mayo Clinic regimen. Nineteen patients were treated with high dose folinic acid ($200mg/m^2$), glucose 5%, 5-FU ($400mg/m^2$) and 22 hr. CIV ($600mg/m^2$) for two consecutive days every two weeks. These patients had failed responses to previous chemotherapy and were above sixty years of age with poor general status. Sixteen patients (six below 60 years) with progressive disease were subjected to low dose folinic acid ($20mg/m^2$)for five days, 5FU($425mg/m^2$) injection bolus for 5 days, every five weeks. An initial evaluation was made in sixty days and responders were reevaluated at sixty days interval or earlier in case of clinical impairment. Based on positive prognosis, the therapy was continued. Evaluation of treatment response was made on the basis of WHO criteria. Results: The response rate was 44% in thirty four evaluable patients, with 4 complete responses (11.8%) and 11 (32.4%) partial responses. The two schedules were well tolerated, whereas, mild toxicity without WHO Grade ${\geq}2$ events was assessed. The response duration was extended (12 months) in a few patients with age above sixty years treated by high dose bimonthly regimen of 5FU/LV. Conclusion: The regimens are safe and effective in advanced colorectal carcinoma patients with poor general status.

Effects of low dose ${\gamma}$ radiation on the uptake of mineral nutrients in chinese cabbage and radish (저선량 ${\gamma}$ 선 조사가 배추와 무 종자의 발아와 양분흡수에 미치는 영향)

  • Yoon, Young-Man;Kim, Nam-Bum;Kim, Jae-Sung;Kim, Jeong-Gyu
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.4
    • /
    • pp.344-348
    • /
    • 1999
  • To investigate hormetic effect of low dose ${\gamma}$-ray on the uptake of mineral nutrients in Chinese cabbage (Brassica campestris var. Hekjinju var. Surim and) and radish (Raphanus sativas var. Chung-un), seeds of these plants were irradiated with the dose of 1 to 10 Gy. Germination rate and dry weight were examined at pot experiment in greenhouse. Samples for analysis of mineral nutrient were harvested at 17 days and at 59 days after seedling and were analyzed by ICP. Brassica campestris varieties showed higher germination rate and dry weight production with increasing ${\gamma}$ ray dose. Dry weight of Hekjinju Surim and were 143% and 138% at 10Gy dose. respectively. There was no tendency in germination rate and dry weight production for Raphanus sativas var. Chung-un with ${\gamma}$-ray irradiation. The pattern of mineral nutrient content of these plants showed ${\gamma}$ or ${\delta}$ type of dose-reaction curve with no siginificant. This investigation suggests that the more results can be required to understand the hormetic effect of low dose ${\gamma}$ ray on the uptake of mineral nutrient for these plants.

  • PDF

The Effect of Low Dose Bupivacaine on Epidural Morphine Analgesia for Postoperative Pian (경막외 몰핀 단독 투여와 국소마취제 혼주가 술후 진통 효과에 미치는 영향)

  • Ha, Han-Soo;Park, Yeong-Cheol;Kim, Hae-Kyoo;Baik, Seong-Wan;Chung, Kyoo-Sub
    • The Korean Journal of Pain
    • /
    • v.7 no.2
    • /
    • pp.188-192
    • /
    • 1994
  • Recently, epidural morphine has been administrated to decrease patients' systemic stress responses such as: suffers, endocrine responses and impairment of pulmonary function, etc. Epidural morphine provided excellent analgesic effect, but incomplete sensory blockade as compared to epidural local anesthetics, which has sympathetic blockade effect and tachyphylaxis. Therefore, the authors surmised that low dose bupivacaine on low dose epidural morphine improved postoperative pain with greater sensory analgesia than epidural morphine alone. The effect of low dose bupivacaine on epidural morphine analgesia for postoperative pain was evaluated in seventy patients. They were physical status I-III by ASA classification. Patients were randomly divided into 2 groups and they were administrated morphine 2.5 mg only (group I), morphine 2.5 mg plus 0.125% bupivacaine (group II) through epidural catheter 1 hour before the end of the operation. During postoperative second days, their analgesic effects were evaluated by visual analogue scale (0-10). Side effects were also evaluated. The results were as follows, 1) On the day of the operation, VAS score showed significant differences between two groups (morphine group $3.20{\pm}0.16$, morphine plus bupivacaine group $2.77{\pm}0.08$; p < 0.05). 2) On the postoperative and second day, there were no statistical differences between the groups according to VAS score. 3) The incidence of pruritus, nausea, and vomiting were no differences in both groups. 4) None of the patients showed objective sedation or a low respiratory rate (< 10 bpm). We concluded that epidural administration of low dose bupivacaine on the epidural morphine analgesia was an effective method to decrease postoperative pain with little change in frequencies of side effects compared to epidural morphine alone.

  • PDF

Nutritional strategy of early amino acid administration in very low birth weight infants

  • Lee, Byong Sop
    • Clinical and Experimental Pediatrics
    • /
    • v.58 no.3
    • /
    • pp.77-83
    • /
    • 2015
  • Relative to a fetus of the same gestational age, very low birth weight (VLBW) infants are more likely to be underfed and to undergo growth restriction during their early hospital stay. The current trend towards "early and aggressive" nutritional strategies in VLBW infants aims to overcome the early nutritional deficiency and thereby boost postnatal catch-up growth, simultaneously improving long-term neurodevelopmental outcomes. Although the minimum starting amino acid (AA) dose to prevent negative nitrogen balance is well established, the upper limit and the rate of increase of early AA doses are controversial. Most randomized controlled trials show that early and high-dose (target, 3.5 to 4.9 g/kg/day) AA regimens, with or without high nonprotein calories, do not improve long-term growth and neurodevelopment. High-dose AA supplementation may lead to early metabolic disturbances and excessive or disproportionate plasma AA levels, particularly in infants of very low gestational age. Further large studies are needed to clarify the optimal strategy for early administration of parenteral AA doses in VLBW infants.

Effect of Low Dose γ Radiation on the Dormancy Breaking and Growth of in vitro Microtubers of Potato (Solanum tuberosum L.) Stored at Low Temperature (저선량 방사선이 저온 저장한 감자 기내 소괴경의 휴면타파와 생육에 미치는 효과)

  • Kim, Jae-Sung;Kim, Dong-Hee;Back, Myung-Hwa;Jeon, Jae-Heung;Lee, Young-Bok
    • Horticultural Science & Technology
    • /
    • v.19 no.4
    • /
    • pp.515-520
    • /
    • 2001
  • To observe the stimulating effect of low dose ${\gamma}$ radiation on the dormancy breaking and growth, microtubers of two potato cultivars (Solanum tuberosum L. cv. Dejima and cv. Superior) were irradiated at the dose of 0.5-30 Gy. Though it varied with cultivars and storage duration, sprouting rate, plant growth and tuber yield were promoted by 2-8 Gy irradiation in microtuber of 'Dejima' stored at low temperature. On the other hand, in microtuber of 'Superior', sprouting rate was promoted by 2 and 4 Gy irradiation, and the growth and tuber yield by 4 Gy irradiation. These results suggest that low dose of ${\gamma}$ radiation could have stimulating effects on the dormancy breaking of microtuber and potato growth.

  • PDF

A study of image evaluation and exposure dose with the application of Tube Voltage and ASIR of Low dose CT Using Chest Phantom (흉부 Phantom을 이용한 Low Dose CT의 관전압과 ASIR(Adaptive Statistical Iterative Reconstruction)적용에 따른 영상평가 및 피폭선량에 관한 연구)

  • Hwang, Hyeseong;Kim, Nuri;Jeong, Yoonji;Goo, Eunhoe;Kim, Kijeong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.2
    • /
    • pp.9-14
    • /
    • 2014
  • Purpose: The purpose of this study has attempted to evaluate and compare the image evaluation and exposure dose by respectively applying Filtered Back Projection(FBP), the existing test method, and Adaptive Statistical Iterative Reconstruction(ASIR) with different values of tube voltage during the Low Dose Computed Tomography(LDCT). Materials and Methods: With the image reconstruction method as basis, Chest Phantom was utilized with the FBP and ASIR set at 10%, 20% respectively, and the change of Tube Voltage (100kVp, 120kVp). For image evaluation, Back ground noise, Signal to Noise ratio(SNR) and Contrast to Noise ratio(CNR) were measured, and, for dose evaluation, CTDIvol and DLP were measured respectively. The statistical analysis was tested with SPSS(ver. 22.0), followed by ANOVA Test conducted after normality test and homogeneity test. (p<0.05). Results: In terms of image evaluation, there was no outstanding difference in Ascending Aorta(AA) SNR and Infraspinatus Muscle(IM) SNR with the different values of ASIR application(p<0.05), but a significant difference with the different amount of tube voltage(p>0.05). Also, there wasn't noticeable change in CNR with ASIR and different amount of Tube Voltage (p<0.05). However, in terms of dose evaluation, CTDIvol and DLP showed contrasting results(p<0.05). In terms of CTDIvol, the measured values with the same tube voltage of 120kVp were 2.6mGy with No-ASIR and 2.17mGy with 20%-ASIR respectively, decreased by 0.43mGy, and the values with 100kVp were 1.61mGy with No-ASIR and 1.34mGy with 20%-ASIR, decreased by 0.27mGy. In terms of DLP, the measured values with 120kVp were $103.21mGy{\cdot}cm$ with No-ASIR and $85.94mGy{\cdot}cm$ with 20%-ASIR, decreased by $17.27mGy{\cdot}cm$(about 16.7%), and the values with 100kVp were $63.84mGy{\cdot}cm$ with No-ASIR and $53.25mGy{\cdot}cm$ with 20%-ASIR, a decrease by $10.62mGy{\cdot}cm$(about 16.7%). Conclusion: At lower tube voltage, the rate of dose significantly decreased, but the negative effects on image evaluation was shown due to the increase of noise. For the future, through the result of the experiment, it is considered that the method above would be recommended for follow-up patients or those who get health checkup as long as there is no interference on the process of diagnosis due to the characteristics of Low Dose examination.

  • PDF

Space Radiation Shielding Calculation by Approximate Model for LEO Satellites

  • Shin Myung-Won;Kim Myung-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.36 no.1
    • /
    • pp.1-11
    • /
    • 2004
  • Two approximate methods for a cosmic radiation shielding calculation in low earth orbits were developed and assessed. Those are a sectoring method and a chord-length distribution method. In order to simulate a change in cosmic radiation environments along the satellite mission trajectory, IGRF model and AP(E)-8 model were used. When the approximate methods were applied, the geometrical model of satellite structure was approximated as one-dimensional slabs, and a pre-calculated dose-depth conversion function was introduced to simplify the dose calculation process. Verification was performed with mission data of KITSAT-1 and the calculated results were also compared with detailed 3-dimensional calculation results using Monte Carlo calculation. Dose results from the approximate methods were conservatively higher than Monte Carlo results, but were lower than experimental data in total dose rate. Differences between calculation and experimental data seem to come from the AP-8 model, for which it is reported that fluxes of proton are underestimated. We confirmed that the developed approximate method can be applied to commercial satellite shielding calculations. It is also found that commercial products of semi-conductors can be damaged due to total ionizing dose under LEO radiation environment. An intensive shielding analysis should be taken into account when commercial devices are used.