• Title/Summary/Keyword: Low Dose Radiation

Search Result 937, Processing Time 0.028 seconds

Growth and Mineral Contents of Spinach (Spinacia oleracea L.) and Radish (Raphanus sativus L.) as Related with a Low Dose Gamma Irradiation

  • Hwangbo, Jun-Kwon;Kim, Jae-Sung;Lim, Ji-Hyeok;Baek, Myung-Hwa;Chung, Byung-Yeoup;Kim, Jin-Hong
    • Korean Journal of Environmental Biology
    • /
    • v.21 no.4
    • /
    • pp.400-404
    • /
    • 2003
  • This study was to evaluate the effects of gamma irradiation on the germination, nutrient concentrations and growth of spinach and radish. Both the spinach and radish seeds exhibited relatively higher germination rates in response to the low doses of gamma irradiation compared to the non -irradiated control. Leaf DW of the radish did not respond to gamma irradiation but that of the spinach increased significantly in response to a gamma radiation of 4 Gy (P< 0.05). Leaf growth parameters of the spinach including the leaf area and SLA (leaf area/leaf dry weight) also demonstrated increased responses to gamma irradiation. R/S (root dry weight/shoot dry weight), root DW and root length of the spinach exhibited a positive response to gamma irradiation while those of the radish did not. In contrast, SRL (root length/root dry weight) significantly decreased with gamma irradiation at 8 Gy for the spinach, but not for the radish. The tissue nitrogen concentrations of the spinach showed an increased response to gamma irradiation while that of the radish did not. Furthermore, higher concentrations of phosphorus, potassium, calcium and magnesium were found in the irradiated spinach, but not in the irradiated radish. It seems that the non-specific physiological and/or biochemical activities of spinach might be accelerated by gamma irradiation, possibly accounting for the stimulation of nutrient uptake from the root media and early biomass accumulation in the current study.

Effects of Fresh Yellow Onion Consumption on CEA, CA125 and Hepatic Enzymes in Breast Cancer Patients: A Double-Blind Randomized Controlled Clinical Trial

  • Jafarpour-Sadegh, Farnaz;Montazeri, Vahid;Adili, Ali;Esfehani, Ali;Rashidi, Mohammad-Reza;Mesgari, Mehran;Pirouzpanah, Saeed
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.17
    • /
    • pp.7517-7522
    • /
    • 2015
  • Onion (Allium cepa) consumption has been remarked in folk medicine which has not been noted to be administered so far as an adjunct to conventional doxorubicin-based chemotherapy in breast cancer patients. To our knowledge, this is the first study aimed to investigate the effects of consuming fresh yellow onions on hepatic enzymes and cancer specific antigens compared with a low-onion containing diet among breast cancer (BC) participants treated with doxorubicin. This parallel design randomized controlled clinical trial was conducted on 56 BC patients whose malignancy was confirmed with histopathological examination. Subjects were assigned in a stratified-random allocation into either group received body mass index dependent 100-160 g/d of onion as high onion group (HO; n=28) or 30-40 g/d small onion in low onion group (LO; n=28) for eight weeks intervention. Participants, care givers and laboratory assessor were blinded to the assignments (IRCT registry no: IRCT2012103111335N1). The compliance of participants in the analysis was appropriate (87.9%). Comparing changes throughout pre- and post-dose treatments indicated significant controls on carcinoembryonic antigen, cancer antigen-125 and alkaline phosphatase levels in the HO group (P<0.05). Our findings for the first time showed that regular onion administration could be effective for hepatic enzyme conveying adjuvant chemotherapy relevant toxicity and reducing the tumor markers in BC during doxorubicin-based chemotherapy.

Comparison of Doses of Single Scan PBS and Layered Rescanning PBS Using Moving Phantom in Proton Therapy (양성자 치료에서 Moving Phantom을 이용한 Single Scan PBS와 Layered Rescanning PBS의 선량비교)

  • Kim, Kyeong Tae;Kim, Seon Yeong;Kim, Dae Woong;Kim, Jae Won;Park, Ji Yeon;Jeon, Sang Min
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.43-49
    • /
    • 2019
  • Purpose : We apply the Layered Rescanning PBS designed to complement the Pencil Beam Scanning(PBS), which is vulnerable to moving organs with the Moving Phantom, and compare the homogeneity with the single scan PBS. Methods and materials: Matrix X (IBA, Belgium) and Moving Phantom (standard imaging, USA) were used. A dose of 200 cGy was measured in the AP direction on a hypothetical tumor $10{\times}10{\times}5cm$. The plan type was planned as 4 kinds of sinlge scan PBS, rescan number 4, 8, 12 times. Were measured three times for each types. During the measurement, the respiratory cycle of the Moving Phantom was generally set to 4 seconds per cycle, and the movement radius in the S-I direction was set to 2 cm. In addition, beam on time was measured. Results : The mean values of $D_{max}$ in the PTV were $246.47{\pm}18.8cGy$, $223.43{\pm}8.92cGy$, and $222.47{\pm}7.7cGy$, $213.9{\pm}6.11cGy$ and the mean values of $D_{min}$ were $165.53{\pm}4.32cGy$, $173.13{\pm}11.94cGy$, $184.13{\pm}8.04cGy$, $182.67{\pm}4.38cGy$ and the mean values of $D_{mean}$ $192.77{\pm}6.98cGy$, $196.7{\pm}4.01cGy$, $198.17{\pm}4.96cGy$, $195.77{\pm}3.15cGy$ respectively. As the number of rescanning increased, the Homogeneity Index converged to 1. The beam on time was measured as 2:15, 3:15, 4:30, 5:37 on average. In the measurement process, in the low dose layer of the MU, the problem was found that it was not rescanned as many times as the set number of rescan. Conclusions : In the treatment of tumors with long-term movements, the application of layered rescanning PBS showed a more uniform dose distribution than single scan PBS. And as the number of rescan increase, the distribution of homogeneity is uniform. Compared with single scan plan and 12 rescan plan, HI value was improved by 0.32. Further studies are expected to be applicable to patients who can not be treated with respiratory synchronous radiation therapy.

Biological Markers as Predictors of Radiosensitivity in Syngeneic Murine Tumors (동계 마우스 종양의 방사선 감수성 예측인자로서의 생물학적 표지자)

  • Chang Sei-Kyung;Kim Sung-Hee;Shin Hyun-Soo;Seong Jin-Sil
    • Radiation Oncology Journal
    • /
    • v.24 no.2
    • /
    • pp.128-137
    • /
    • 2006
  • Purpose: We investigated whether a relationship exists between tumor control dose 50 ($TCD_{50}$) or tumor growth delay (TGD) and radiation induced apoptosis (RIA) in syngeneic murine tumors. Also we investigated the biological markers that can predict radiosensitivity in murine tumor system through analysis of relationship between $TCD_{50}$, TGD, RIA and constitutive expression levels of the genetic products regulating RIA. Materials and Methods: Syngeneic murine tumors such as ovarian adenocarcinoma, mammary carcinoma, squamous cell carcinoma, fibrosarcoma, hepatocarcinoma were used In this study. C3H/HeJ mice were bred and maintained in our specific pathogen free mouse colony and were $8{\sim}12$ weeks old when used for the experiments. The tumors, growing in the right hind legs of mice, were analyzed for $TCD_{50}$, TGD, and RIA at 8 mm in diameter. The tumors were also analyzed for the constitutive expression levels of $p53,\;p21^{WAF1/CIP1},\;BAX,\;Bcl-2,\;Bcl-X_L,\;Bcl-X_S$, and p34. Correlation analysis was peformed whether the level of RIA were correlated with $TCD_{50}$ or TGD, and the constitutive expression levels of genetic products regulating RIA were correlated with $TCD_{50}$, TGD, RIA. Results: The level of RIA showed a significant positive correlation (R=0.922, p=0.026) with TGD, and showed a trend to correlation (R=-0.848), marginally significant correlation with $TCD_{50}$ (p=0.070). It indicates that tumors that respond to radiation with high percentage of apoptosis were more radiosensitive. The constitutive expression levels of $p21^{WAF1/CIP1}$ and 34 showed a significant correlation either with $TCD_{50}$ (R=0.893, p=0.041 and R=0.904, p=0.035) or with TGD (R=-0.922, p=0.026 and R=-0.890 p=0.043). The tumors with high constitutive expression levels of $p21^{WAF1/CIP1}$ or p34 were less radiosensitive than those with low expression. Conclusion: Radiosensitivity may be predicted with the level of RIA in murine tumors. The constitutive expression levels of $p21^{WAF1/CIP1}$ or p34 can be used as biological markers which predict the radiosensitivity.

Analysis of Prognostic Factors in Patients with Carcinoma of Uterine Cervix (자궁경부암의 방사선치료시 예후인자의 재분석)

  • Kim Jae Young;Cho Chul Koo;Shim Jae Won;Yoo Seong Yul;Kim Mi Sook;Yun Hyong Geun
    • Radiation Oncology Journal
    • /
    • v.14 no.4
    • /
    • pp.307-315
    • /
    • 1996
  • Purpose : The authors conducted a retrospective analysis of patients with the carcinoma of uterine cervix treated with curative radiation therapy to evaluate the prognostic factors that would affect the results of the therapy and to get the critical ideas in determining more aggressive treatment schedule. Methods and Materials : From January 1987 to December 1988. Four hundreds and sixty patients with uterine cervical carcinomas treated with radiotherapy at KCCH were registered to this retrospective study. One hundred and three patients were treated with external radiation therapy alone, and 357 patients were treated with external radiation followed by low dose rate intracavitary radiation therapy. The follow-up rate was 88% and median follow-up duration was 48 months. Results : The overall 5 year survival rate of the patients was 67.7%, and when classified by FIGO stages, 5 year survival rates were 81.2%, 76.3%, 73.1%, 50%. 52.3%, 11.5% for stages Ib, IIa, IIb, IIIa, IVa respectively. Tumor size(p=0.0002), endocervical growth pattern(p=0.003), lymph node invasion(p=0.0001), mean hemoglobin level(p=0.0001), and pathologic cell type(p=0.0001) were significant prognostic factors and decrease in survival for young age patient group was marginally important (p=0.03). Conclusion : Significant prognostic factors in the radiation therapy of the uterine cervical carcinoma were tumor size, growth pattern of tumor, lymph node invasion, pathologic cell type, hemoglobin level of patients during treatment and lower survival rate in young age group was obvious, too. Patients with large size tumor(${\geq)$4cm), especially combined with endocervical growth patterns or advanced stages(III or more) need more aggressive treatment to improve the outcome of treatment. And positive feature of lymph node invasion affected the result of therapy, so improvement in the diagnostic and therapeutic trial is essential.

  • PDF

Concurrent Chemoradiation Therapy in Stage III Non-small Cell Lung Cancer (III 기 비소세포성 폐암에서 Cisplatin-방사선동시병합요법의 효과)

  • Kim In Ah;Choi Ihl Bhong;Kang Ki Mun;Jang Jie Young;Song Jung Sub;Lee Sun Hee;Kuak Mun Sub;Shinn Kyung Sub
    • Radiation Oncology Journal
    • /
    • v.15 no.1
    • /
    • pp.27-36
    • /
    • 1997
  • Purpose : This study was tried to evaluate the Potential benefits of concurrent chemoradiation therapy (low dose daily cisplatin combined with split course radiation therapy) compared with conventional radiation therapy alone in stage III non-small cell lung cancer. The end points of analyses were response rate. overall survival, survival without locoregional failure, survival without distant metastasis, prognostic factors affecting survival and treatment related toxicities. Materials and Methods : Between April 1992 and March 1994, 32 patients who had stage III non-small cell lung cancer were treated with concurrent chemoradiation therapy. Radiation therapy for 2 weeks (300 cGy given 10 times up to 3000 cGy) followed by a 3 weeks rest period and then radiation therapy for 2 more weeks (250 cGy given 10 times up to 2500 cGy) was combined with $6mg/m^2$ of cisplatin. Follow-up period ranged from 13 months to 48 months with median of 24 months. Historical control group consisted of 32 patients who had stage III non-small cell lung cancer were received conventionally fractionated (daily 170-200 cGy) radiation therapy alone. Total radiation dose ranged from 5580 cGy to 7000 cGy with median of 5940 cGy. Follow-up Period ranged from 36 months to 105 months with median of 62 months. Result : Complete reponse rate was higher in chemoradiation therapy (CRT) group than radiation therapy (RT) group (18.8% vs. 6.3%, CRT group showed lower in-field failure rate compared with RT group(25% vs. 47%. The overall survival rate had no significant differences in between CRT group and RT group (17.5% vs. 9.4% at 2 years). The survival without locoregional failure (16.5% vs. 5.3% at 2 years) and survival without distant metastasis (17% vs. 4.6% at 2 years) also had no significant differences. In subgroup analyses for Patients with good performance status (Karnofsky performance scale 80), CRT group showed significantly higher overall survival rate compared with RT group (62.5% vs. 15.6% at 2 years). The prognostic factors affecting survival rate were performance status and pathologic subtype (squamous cell cancer vs. nonsquamous cell cancer) in CRT group. In RT alone group, performance status and stage (IIIa vs IIIb) were identified as a Prognostic factors. RTOG/EORTC grade 2-3 nausea and vomiting(22% vs 6% and bone marrow toxicities (25% vs. 15.6% were significantly higher in CRT group compared with RT alone group. The incidence of RTOG/EORTC grade 3-4 pulmonary toxicity had no significant differences in between CRT group and RT group (16% vs. 6%. The incidence of WHO grade 3-4 pulmonary fibrosis also had no significant differences in both group (38% vs. 25%. In analyses for relationship of field size and Pulmonary toxicity, the Patients who treated with field size beyond 200cm2 had significantly higher rates of pulmonary toxicities. Conclusion : The CRT group showed significantly higher local control rate than RT group. There were no significant differences of survival rate in between two groups. The subgroup of patients who had good performance status showed higher overall survival rate in CRT group than RT group. In spite of higher incidence of acute toxicities with concurrent chemoradiation therapy, the survival gain in subgroup of patients with good performance status were encouraging. CRT group showed higher rate of early death within 1 year, higher 2 year survival rate compared with RT group Therefore, to evaluate the accurate effect on survival of concurrent chemoradiation therapy, systematic follow-up for long term survivors are needed.

  • PDF

TFWT and OBT Concentrations in Rice Plants Exposed to HTO Vapor during Daytime and Nighttime at Different Seed-Developing Stages (벼의 종실 발육단계에 따른 주간 및 야간 HTO 증기 피폭시 TFWT 및 OBT 농도)

  • Choi, Yong-Ho;Lim, Kwang-Muk;Lee, Won-Yun;Kang, Hee-Suk;Choi, Heui-Joo;Lee, Han-Soo;Diabate, Silvia;Strack, Siegfried
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.1
    • /
    • pp.9-18
    • /
    • 2003
  • Rice plants at different seed-developing stages were exposed to HTO vapor in an exposure box for 1 h during daytime and nighttime to investigate the levels of tissue free water $^3H$ (TFWT) and organically bound $^3H$ (OBT) in different plant parts. In the daytime experiment, TFWT concentrations in leaves at the end of exposure $(h_0)$ were around 100% of the 1 hour mean HTO concentrations in air moisture whereas in the nighttime experiment, they were as low as $30{\sim}40%$ of the air concentration. TFWT concentrations in both experiments decreased very rapidly in the beginning but much mote slowly later and those at harvest were hundreds to hundred thousands times lower than those at $h_0$. OBT concentrations varied with time in different manners depending on plant parts and exposure times and differed between at $h_0$ and at harvest by factors of less than 10 on the whole. Even during nighttime exposures, OBT was produced at about a third the rate for daytime exposures. The degree of the conversion of airborne HTO into OBT in mature rice seeds, being several times higher in the daytime experiment than in the nighttime experiment, was highest after the exposure peformed at the most actively seed-developing stage for both experiments. It is estimated that OBT would contribute much more to the ingestion radiation dose than TFWT if rice plants are exposed to HTO vapor for the seed-developing period.

Evaluation of Image Quality for Diagnostic Digital Chest Image Using Ion Chamber in the Total Mastectomy (변형근치유방절제술 환자의 Ion chamber 변화에 따른 디지털 흉부 영상의 화질 평가)

  • Lee, Jin-Soo;Ko, Seong-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Park, Hyong-Hu;Kim, Donghyun;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.3
    • /
    • pp.204-210
    • /
    • 2013
  • The patients who had been operated total mastectomy are different from general women in their breasts thickness due to breast surgery. As a result, digital chest image from total mastectomy patients will be different attenuation. The main objective for this study is to show that a proper Ion chamber standard combination measuring MTF which is objective basis for Digital image, when be x-ray for total mastectomy patient. We have designed the unique number that shown Left is 1, Right is 2, Center is 3 and have put the edge phantom on detector ion chamber. Lastly, we have obtained experiment images. The evaluations of all image quality have measured by 50% MTF of spatial resolution and absorption dose using Matlab(R2007a). The result showed that average exposure condition, MTF value, absorption dose for 1+3 and 2+3 combinations were 2.745 mAs, 1.925 lp/mm, 0.688 mGy. Consequently, that showed high MTF, DQE and low dose than other combinations. Therefore, a proper changes of ion chambers are able to improve image quality and to reduce radiation exposure when be X-ray for total mastectomy patients. Also, it will be possible to standard for application chamber combination and utilization on clinical detection.

A Study on Radiographical Conditions and Exposure Doses During Chest Radiography at Medical Facilities in Pusan (부산지역 의료기관의 흉부촬영 조건과 피폭선량에 관한 조사연구)

  • Jeon, Sung-Oh;Cho, Young-Ha
    • Journal of radiological science and technology
    • /
    • v.20 no.2
    • /
    • pp.49-55
    • /
    • 1997
  • This study was carried out to investigate radiographical and operating conditions of X-ray units and exposure doses to patients during chest radiography, so that the results could provide basic data used for reducing the exposure dose and for providing the diagnostic information with better quality. The conditions and exposure doses of 100 X-ray units mainly used for chest radiography were examined and also 100 radiological technologists mainly handling those apparatus at 76 medical facilities in Pusan were surveyed using a questionnaire from October 1 to December 31 in 1995. The following results were obtained from the study : 1. It was found that most units were capable of taking a high tube voltage radiography by showing 67% of the units equipped with the maximum tube voltage of 150 kV, 94% with more than 500 mA for the rating capacity and 85% with the full wave type of a signal phase. 2. For actual chest radiographical conditions, however, 80% of the units were operated at $60{\sim}100\;kVp$ and only 14% at 100 kVp and over for the high tube voltage. 3. The average exposure time was less than 0.1 second, and eighty four percent of the units adapted the X-ray tube currents ranging from 200 to 300 mA, 80% the focus-film distances between 180 and 210 cm, and 63% the focus sizes of more than 2.0 mm. 4. Most units(98%) employed additional filters made of aluminum, 75% the thickness of filters less than 2.0 mm, and only 2 units the compound filters. 5. Ortho chromatic system was only adopted in 13% of screen film system for the units, and 73% used the grid ratio at 8 : 1 for the low tube voltage during chest radiography. 6. The average exposure dose of all X-ray units during chest radiography was $371\;{\mu}Sv$ with a difference of about 16 times between the minimum to the maximum, and $386\;{\mu}Sv$ both at hospitals and at health centers, followed by $380\;{\mu}Sv$ at general hospitals and $263\;{\mu}Sv$ at university hospitals without showing any statistically significant differences. In conclusion, since patients during chest radiography at medical facilities in Pusan exposed to high levels of radiation, it is recommended that appropriate added filters and grids necessary for the high tube voltage radiography and high-speed screen systems should be adopted and used as soon as possible in order to reduce exposure dose to the patients.

  • PDF

A Study on the Fabrication and Physical Properties of $Ca_2SiO_4$:La Thermoluminescent Phosphors ($Ca_2SiO_4$: La 열형광체 제작과 물리적 특성에 관한 연구)

  • Kim, Choung-Mi;Seo, Mi-Kyong
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.4
    • /
    • pp.5-10
    • /
    • 2010
  • The $Ca_2SiO_4$ phosphors doped by La with 0.1 wt%, 0.3 wt%, 0.5 wt%, and 1.0 wt% concentration were prepared by sintering at $1000^{\circ}C$ for 90 minutes in N2 atmosphere. The phosphors were ground in powdered form and were grouped in $100{\mu}m$ size, then the samples had been exposed to low energy X-ray and UV light. The TL glow curves were measured by heating the phosphors at $10^{\circ}C/s$ rate. There was no significantly meaningful correlation between the TL intensity and the doping level. The intensities of the TL peak measured from X-ray irradiated samples doped with 0.1 wt% were relatively strong. The activation energy and the frequency factor were 0.434 ~ 0.516 eV and 0.5 ~ 0.56, respectively. The intensities of the TL peak measured from UV irradiated samples doped with 0.3 wt% were relatively strong. The activation energy and frequency factor were 0.415 ~ 0.477 eV and 0.5 ~ 0.53, respectively. The TL process were found to be the 2nd order for both X-ray and UV irradiation. The TL intensity was increased linearly with the increase of the radiation dose. In summary, the $Ca_2SiO_4 phosphors developed in this study showed good TL characteristics at low energy X-ray and UV light. We believe they will be used as TLDs in near future for personal and environmental radiation detection dosimetry.