• Title/Summary/Keyword: Low Dose Exposure

Search Result 465, Processing Time 0.035 seconds

Development of Film Verification as the QA of IMRT for Advanced Hepatoma Patients (간암 환자의 세기조절 방사선치료에서 임상적응 가능한 QA 기법의 개발)

  • Kim Myung-Se
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.40-46
    • /
    • 2006
  • Hepatoma is one of 3 most common malignancies in Korea, the survival rate is not improved since last decades because of delayed diagnosis and limited treatment conditions. Radiation was one of treatment options but the impact on the survival is not remarkable. High dose exposure to target area was suggested for improved effect but low tolerance dose of normal liver tissue is the main limited factor. IMRT is the advanced form of 3DCRT, for focusing high dose on target with minimal dose to surrounding normal tissues. Motion of the tumor by respiration, cardiac pulsation and peristalsis is the main treatment harrier of IMRT for treatment of hepatoma patients. Development of QA technique for acceptable geometrical uncertainties and dose error on target volume is essential for IMRT in clinical treatment but proper QA technique is not yet developed. This study compared the verification film dosimetry with measured dose in phantom and calculated dose in planning computer on exactly same conditions of patient treatments. Within 3% dose differences between 3 groups were confirmed. We suggest that our verification QA technique is easy, economic, iterative and acceptable in clinical application for advanced hepatoma patients.

  • PDF

Effect on Computerized Neurobehavioral Test Performance of the Car Painters Exposed to Organic Solvents (자동차 페인트 도장공에 있어서 컴퓨터를 이용한 신경행동검사 수행기능의 평가)

  • Sa, Kong-Joon;Chung, Jong-Hak
    • Journal of Preventive Medicine and Public Health
    • /
    • v.27 no.3 s.47
    • /
    • pp.487-504
    • /
    • 1994
  • A cross-sectional study was performed to evaluate the effects of chronic low-dose solvent on neurobehavioral performance of 118 male car painters. A control group of 113 workers matched for age was selected from different sections of the factory. The mean age and the mean duration of employment were 33 years and 6.7 years in both groups. Mean years of education were 11.4 years in car painters and 11.8 years in controls. Each worker completed a medical and occupational questionnaire and four tests of Swedish performance evaluation system. These included simple reaction time, symbol digit, digit span and finger tapping speed. Althougth the mean duration of employment was 6.7 years, comparison of mean performance showed a significantly poorer performance on simple reaction time (p<0.05), symbol digit(p<0.01) and digit span(p<0.05) in car painters. In univariate analysis, age and educational level contributed to poorer performance on symbol digit and digit span. Smoking appeared to slow finger tapping speed in car painters. Performance of four tests of car painters exposed to high level of solvent was poorer than that of car painters exposed to low level. In multiple regression models, controlling for age, alcohol, smoking and shift work, solvent exposure was found to be associated with performance of simple reaction time, symbol digit and digit span and exposure to high level of solvent was related to poorer performance of symbol digit and digit span.

  • PDF

A Probabilistic Safety Assessment of a Pyro-processed Waste Repository (A-KRS 처분 시스템 확률론적 안전성 평가)

  • Lee, Youn-Myoung;Jeong, Jongtae
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.10 no.4
    • /
    • pp.263-272
    • /
    • 2012
  • A GoldSim template program for a safety assessment of a hybrid-typed repository system, called A-KRS, in which two kinds of pyro-processed radioactive wastes, low-level metal wastes and ceramic high-level wastes that arise from the pyro-processing of PWR nuclear spent fuels are disposed of, has been developed. This program is ready both for a deterministic and probabilistic total system performance assessment which is able to evaluate nuclide release from the repository and farther transport into the geosphere and biosphere under various normal, disruptive natural and manmade events, and scenarios. The A-KRS has been probabilistically assessed with 9 selected input parameters, each of which has its own statistical distribution for a normal release and transport scenario associated with nuclide release and transport in and around the repository. Probabilistic dose exposure rates to the farming exposure group have been evaluated. A sensitivity of 9 selected parameters to the result has also been investigated to see which parameter is more sensitive and important to the exposure rates.

Effects of Eucalyptus and Geranium on Production of IL-2 and IL-4 in Mouse Splenocytes (Eucalyptus와 geranium이 마우스 splenocytes에서 IL-2 및 IL-4 생성에 대한 효과)

  • Cha Bong Kyu;Chang Myung Woong;Jeong Young Kee;Kim Kwang Hyuk
    • Journal of Life Science
    • /
    • v.16 no.1
    • /
    • pp.162-167
    • /
    • 2006
  • Aromatherpy is the controlled use of essential oils to promote health and well-being. In this work we have investigated the effect of eucalyptus and geranium on the production of interleukin-2 (IL-2) and interleukin4 (IL-4). Mouse splenocytes were incubated with essential oils. The culture supernatants of mouse splenocytes exposed with these oils were harvested to assay IL-2 and IL-4 production. The quantitative changes of IL-2 in splenocytes culture supernatants after exposure with these oils were decreased at high doses, but increased at low doses. But its of IL-4 were increased generally at high doses of eucalyptus. In case of the exposure of geranium, its of IL-4 were dose-dependently increased. These kinds of essential oils showed the probability to improve IL-2- and IL-4-related immune responses at the optimum exposure.

The Evaluation for Attenuation Map using Low Dose in PET/CT System (PET/CT 시스템에서 감쇠지도를 만들기 위한 저선량 CT 평가)

  • Nam, So-Ra;Cho, Hyo-Min;Jung, Ji-Young;Lee, Chang-Lae;Lim, Han-Sang;Park, Hoon-Hee;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.134-138
    • /
    • 2007
  • The current PET/CT system with high quality CT images not only increases diagnostic value by providing anatomic localization, but also shortens the acquisition time for attenuation correction than primary PET system. All commercially available PET/CT system uses the CT scan for attenuation correction instead of the transmission scan using radioactive source such as $^{137}Cs,\;^{68}Ge$. However the CT scan may substantially increase the patient dose. The purpose of this study was to evaluate quality of PET images reconstructed by CT attenuation map using various tube currents. in this study, images were acquired for 3D Hoffman brain phantom and cylindrical phantom using GE DSTe PET/CT system. The emission data were acquired for 10 min using phantoms after injecting 44.03 MBq of $^{18}F-FDG$. The CT images for attenuation map were acquired by changing tube current from 10 mA to 95 mA with fixed exposure time of 8 sec and fixed tube voltage of 140 kVp. The PET images were reconstructed using these CT attenuation maps. Image quality of CT images was evaluated by measuring SD (standard deviation) of cylindrical phantom which was filled with water and $^{18}F-FDG$ solution. The PET images were evaluated by measuring the activity ratio between gray matter and white matter in Hoffman phantom images. SDs of CT images decrease by increasing tube current. When PET images were reconstructed using CT attenuation maps with various tube currents, the activity ratios between gray matter and white matter of PET images were almost same. These results indicated that the quality of the PET images using low dose CT data were comparable to the PET images using general dose CT data. Therefore, the use of low dose CT is recommended than the use of general dose CT, when the diagnostic high quality CT is not required. Further studies may need to be performed for other system, since this study is limited to the GE DSTe system used in this study.

  • PDF

Prevalence Rate of Lead Related Subjective Symptoms in Lead Workers (연취급 근로자의 연폭로 수준에 따른 주관적 자각증상 호소율)

  • Jeong, Du-Shin;Kim, Hwa-Sung;Ahn, Kyu-Dong;Lee, Byung-Kook
    • Journal of Preventive Medicine and Public Health
    • /
    • v.26 no.2 s.42
    • /
    • pp.251-267
    • /
    • 1993
  • The relationship between lead related subject symptoms and lead exposure indices was studied in 435 male lead workers in thirteen lead using industries. 212 male office workers who were not exposed to lead occupationally were also studied as a control group. Fourteen lead related symptoms were selected. They were further subdivied into 4 sub-symptom groups such as 1) gastrointestinal, 2) neuromuscular and joint 3) constitutional, and 4) psychological symptoms. Symptom questionnaires were provided to the workers and filled up by themselves and reconfirmed by interviewer(doctor). The test used fer the evaluation of lead exposure were blood lead(PbB), zinc protoporphyrin in whole blood(ZPP), hemoglobin(Hb), hematocrit (Hct), delta-aminolevulinic acid in urine(DALA). The results obtained were as follows; 1. The higher prevalence rate in the sub-group of neuromuscular and joint symptoms was observed in occupationally lead exposed subjects than non-exposed subjects. Among the sub-groups, the most frequent symptom was 'numbness of finger, hands or feet', and the prevalence of the symptom of 'arthralgia', 'weakness of fingers, hands or feet' and 'myalgia' were higher in order. 2. While the symptom which showed the biggest difference of prevalence rate among the 14 symptoms between exposed and non-exposed subjects was 'numbness of fingers, hands or feet', the symptom which showed the highest prevalence rate was 'feeling tired generally' in exposed and non-exposed subjects, but no statistical difference of symptom prevalence were observed. 3. In total study population, PbB and ZPP had dose-response relationship with 4 symtoms of neuromuscular and joint symptoms ('numbness of finger, hands or feet', 'arthralgia', 'weakness of fingers, hands or feet' and 'myalgia') and one symptom of gastrointestinal group('intermittent pains in lower abdomen'). 4. In lead exposed workers, only neuromuscular and joint symptoms group showed dose-response relationship with PbB and ZPP, 5. In lead exposed workers, the prevalance rate of overall symptoms of lead workers with age below 39 years was higher than that of lead workers with age above 40. While neuromuscular and joint symptoms group had a dose-response relationship with PbB in former group, it had a dose-response relationship with ZPP in latter group. 6. Age adjusted odds ratios of symptoms of non-exposed with exposed and odds ratios of low exposed with high exposed workers showed the dose-response relationship of lead exposure with neuromuscular and joint symptoms group('numbness of fingers, hands or feet', 'arthralgia', 'weakness of fingers, hands or feet' and 'myalgia') and gastrointestinal symptoms group('intermittent pains in lower abdoman').

  • PDF

Performance Analysis of Low-level Radiation Shielding Sheet with Diamagnetic Nanoparticles

  • Cho, Jae-Hwan;Kim, Myung-Sam
    • Journal of Magnetics
    • /
    • v.20 no.2
    • /
    • pp.103-109
    • /
    • 2015
  • In this study, the authors attempted to produce a medical radiation shielding fiber that can be produced at a nanosize scale and that is, unlike lead, harmless to the human body. The performance of the proposed medical radiation shielding fiber was then evaluated. First, diamagnetic bismuth oxide, an element which, among elements that have a high atomic number and density, is harmless to the human body, was selected as the shielding material. Next, 10-100 nm sized nanoparticles in powder form were prepared by ball milling the bismuth oxide ($Bi_2O_3$), the average particle size of which is $1-500{\mu}m$, for approximately 10 minutes. The manufactured bismuth oxide was formed into a colloidal solution, and the radiation shielding fabric was fabricated by curing after coating the solution on one side or both sides of the fabric. The thicknesses of the shielding sheets prepared with bismuth oxide were 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, and 1.0 mm. An experimental method was used to measure the absorbed dose and irradiation dose by using the lead equivalent test method of X-ray protection goods presented by Korean Industrial Standards; the resultant shielding rate was then calculated. From the results of this study, the X-ray shielding effect of the shielding sheet with 0.1 mm thickness was about 55.37% against 50 keV X-ray, and the X-ray shielding effect in the case of 1.0 mm thickness showed shielding characteristics of about 99.36% against 50 keV X-ray. In conclusion, it is considered that nanosized-bismuth radiation shielding fiber developed in this research will contribute to reducing the effects of primary X-ray and secondary X-ray such as when using a scattering beam at a low level exposure.

An Iterative Image Reconstruction Method for the Region-of-Interest CT Assisted from Exterior Projection Data (Exterior 투영데이터를 이용한 Region-of-Interest CT의 반복적 영상재구성 방법)

  • Jin, Seung Oh;Kwon, Oh-Kyong
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.132-141
    • /
    • 2014
  • In an ordinary CT scan, a large number of projections with full field-of-view (FFOV) are necessary to reconstruct high resolution images. However, excessive x-ray dosage is a great concern in FFOV scan. Region-of-interest (ROI) CT or sparse-view CT is considered to be a solution to reduce x-ray dosage in CT scanning, but it suffers from bright-band artifacts or streak artifacts giving contrast anomaly in the reconstructed image. In this study, we propose an image reconstruction method to eliminate the bright-band artifacts and the streak artifacts simultaneously. In addition to the ROI scan for the interior projection data with relatively high sampling rate in the view direction, we get sparse-view exterior projection data with much lower sampling rate. Then, we reconstruct images by solving a constrained total variation (TV) minimization problem for the interior projection data, which is assisted by the exterior projection data in the compressed sensing (CS) framework. For the interior image reconstruction assisted by the exterior projection data, we implemented the proposed method which enforces dual data fidelity terms and a TV term. The proposed method has effectively suppressed the bright-band artifacts around the ROI boundary and the streak artifacts in the ROI image. We expect the proposed method can be used for low-dose CT scans based on limited x-ray exposure to a small ROI in the human body.

Protective effect of dietary chitosan on cadmium accumulation in rats

  • Kim, Mi Young;Shon, Woo-Jeong;Park, Mi-Na;Lee, Yeon-Sook;Shin, Dong-Mi
    • Nutrition Research and Practice
    • /
    • v.10 no.1
    • /
    • pp.19-25
    • /
    • 2016
  • BACKGROUND/OBJECTIVES: Cadmium is a toxic metal that is an occupational and environmental concern especially because of its human carcinogenicity; it induces serious adverse effects in various organs and tissues. Even low levels of exposure to cadmium could be harmful owing to its extremely long half-life in the body. Cadmium intoxication may be prevented by the consumption of dietary components that potentially reduce its accumulation in the body. Dietary chitosan is a polysaccharide derived from animal sources; it has been known for its ability to bind to divalent cations including cadmium, in addition to other beneficial effects including hypocholesterolemic and anticancer effects. Therefore, we aimed to investigate the role of dietary chitosan in reducing cadmium accumulation using an in vivo system. MATERIALS/METHODS: Cadmium was administered orally at 2 mg (three times per week) to three groups of Sprague-Dawley rats: control, low-dose, and high-dose (0, 3, and 5%, respectively) chitosan diet groups for eight weeks. Cadmium accumulation, as well as tissue functional and histological changes, was determined. RESULTS: Compared to the control group, rats fed the chitosan diet showed significantly lower levels of cadmium in blood and tissues including the kidneys, liver, and femur. Biochemical analysis of liver function including the determination of aspartate aminotransferase and total bilirubin levels showed that dietary chitosan reduced hepatic tissue damage caused by cadmium intoxication and prevented the associated bone disorder. CONCLUSIONS: These results suggest that dietary chitosan has the potential to reduce cadmium accumulation in the body as well as protect liver function and bone health against cadmium intoxication.

Enhancement of Image Quality Using Detector Filter (검출기 필터를 이용한 화질의 향상)

  • Lim, Jong-Nam;Kim, Hyung-Tae;Kim, Min-Hye;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.451-456
    • /
    • 2016
  • Radiation dose to patient is unavoidable when diagnosis is carried out using X-ray. Radiation diagnosis using dual energy X-ray was examined to verify the possibility of medical applications by SNR and image scoring. The dual energy X-ray was realized by combining together two image plates and filter of 0.5 mm thick Cu or Al. Under one X-ray exposure, contrast enhanced image was obtained using two images of image plates. The enhanced image showed higher SNR and image score compared to the first image which was the image recorded with the first image plate. The dual energy X-ray technique would be a very useful method for obtaining higher SNR image and for realizing very low dose, and could be applied to medical applications.