• Title/Summary/Keyword: Low Dose

Search Result 2,905, Processing Time 0.035 seconds

Effects of Naloxone on Morphine Analgesia and Spinal c-fos Expression in Rat Formalin Test (Naloxone이 흰쥐 Formalin Test에서 Morphine의 진통효과와 척수 c-fos 유전자 발현에 미치는 영향)

  • Song, Sun Ok;Seok, Je Hong;Lee, Deok Hee;Park, Dae Pal;Kim, Seong Yong;Lim, Jeong Sook;Song, Sun Kyo;Lee, Nam Hyuk
    • The Korean Journal of Pain
    • /
    • v.18 no.2
    • /
    • pp.124-132
    • /
    • 2005
  • Background: This study was performed to evaluate the dose-related effects of naloxone on morphine analgesia in the rat formalin test, and observe the correlation of pain behavior and spinal c-fos expression induced by a formalin injection. Methods: Fifty rats were divided into five groups; control, morphine (morphine pre-treated, intra-peritoneal injection of 0.1 mg of morphine 5 min prior to formalin injection), and three naloxone groups, which were divided according to the administered dose-ratio of naloxone to morphine 20 : 1 ($5{\mu}g$), 10 : 1 ($10{\mu}g$), and 1 : 1 ($100{\mu}g$) representing the low-, medium-, and high-dose naloxone groups, respectively, were injected intra-peritoneally 16 min after a formalin. A fifty ul of 5% formalin was injected into the right hind paw. All rats were observed for their pain behavior according to the number of flinches during phases 1 (2-3, 5-6 min) and 2 (1 min per every 5 min from 10 to 61 min). The spinal c-fos expression was quantitatively analyzed at 1 and 2 hours after the formalin injection using a real-time PCR. Results: The morphine pre-treated (morphine and three naloxone) groups during phase 1, and the morphine, low- and medium-dose naloxone groups during phase 2, showed significantly less flinches compared to those of the control (P < 0.05). In the three naloxone groups, the numbers of flinches were transiently reduced following the naloxone injection in the low- and medium-dose groups compared to those of the morphine group (P < 0.05). The duration of the reduced flinches was longer in the medium-dose group (P < 0.05). The high-dose group revealed immediate increases in flinches immediately after the naloxone injection compared to those of the morphine, low- and medium-dose groups (P < 0.05 for each). The spinal c-fos expression showed no significant patterns between the experimental groups. Conclusions: Our data suggest that relatively low-dose naloxone (1/20 to 1/10 dose-ratio of morphine) transiently potentiates morphine analgesia; whereas, high-dose (equal dose-ratio of morphine) reverses the analgesia, and the spinal c-fos expression does not always correlate with pain behavior in the rat formalin test.

Low-Dose Radiation Stimulates the Proliferation of Normal Human Lung Fibroblasts Via a Transient Activation of Raf and Akt

  • Kim, Cha Soon;Kim, Jin Kyoung;Nam, Seon Young;Yang, Kwang Hee;Jeong, Meeseon;Kim, Hee Sun;Kim, Chong Soon;Jin, Young-Woo;Kim, Joon
    • Molecules and Cells
    • /
    • v.24 no.3
    • /
    • pp.424-430
    • /
    • 2007
  • The biological effects of low-dose radiation have been investigated and debated for more than a century, but its cellular effects and regulatory mechanisms remain poorly understood. This study shows the human cellular responses to low-dose radiation in CCD-18 Lu cells, which are derived from normal human lung fibroblasts. We examined a colony-forming assay for cell survival by ionizing radiation. Live cell counting and cell cycle analysis were measured for cell proliferation and cell cycle progression following low-dose irradiation. We examined Raf and Akt phosphorylation to determine the proliferation mechanism resulting from low-dose radiation. We also observed that p53 and p21 were related to cell cycle response. We found that 0.05 Gy of ionizing radiation enhanced cell proliferation and did not change the progression of the cell cycle. In addition, 0.05 Gy of ionizing radiation transiently activated Raf and Akt, but did not change phospho-p53, p53 and p21 in CCD-18 Lu cells. However, 2 Gy of ionizing radiation induced cell cycle arrest, phosphorylation of p53, and expression of p53 and p21. The phosphorylation of Raf and Akt proteins induced by 0.05 Gy of ionizing radiation was abolished by pre-treatment with an EGFR inhibitor, AG1478, or a PI3k inhibitor, LY294002. Cell proliferation stimulated by 0.05 Gy of ionizing radiation was blocked by the suppression of Raf and Akt phosphorylation with these inhibitors. These results suggest that 0.05 Gy of ionizing radiation stimulates cell proliferation through the transient activation of Raf and Akt in CCD-18 Lu cells.

Low-dose CT Image Denoising Using Classification Densely Connected Residual Network

  • Ming, Jun;Yi, Benshun;Zhang, Yungang;Li, Huixin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.6
    • /
    • pp.2480-2496
    • /
    • 2020
  • Considering that high-dose X-ray radiation during CT scans may bring potential risks to patients, in the medical imaging industry there has been increasing emphasis on low-dose CT. Due to complex statistical characteristics of noise found in low-dose CT images, many traditional methods are difficult to preserve structural details effectively while suppressing noise and artifacts. Inspired by the deep learning techniques, we propose a densely connected residual network (DCRN) for low-dose CT image noise cancelation, which combines the ideas of dense connection with residual learning. On one hand, dense connection maximizes information flow between layers in the network, which is beneficial to maintain structural details when denoising images. On the other hand, residual learning paired with batch normalization would allow for decreased training speed and better noise reduction performance in images. The experiments are performed on the 100 CT images selected from a public medical dataset-TCIA(The Cancer Imaging Archive). Compared with the other three competitive denoising algorithms, both subjective visual effect and objective evaluation indexes which include PSNR, RMSE, MAE and SSIM show that the proposed network can improve LDCT images quality more effectively while maintaining a low computational cost. In the objective evaluation indexes, the highest PSNR 33.67, RMSE 5.659, MAE 1.965 and SSIM 0.9434 are achieved by the proposed method. Especially for RMSE, compare with the best performing algorithm in the comparison algorithms, the proposed network increases it by 7 percentage points.

Prolonged low-dose cyclophosphamide treatment after pulse therapy attenuates lung injury in rats with paraquat intoxication

  • Gao, Jie;Feng, Shunyi;Li, Yong
    • The Korean journal of internal medicine
    • /
    • v.33 no.6
    • /
    • pp.1137-1142
    • /
    • 2018
  • Background/Aims: This study tested the hypothesis that prolonged low-dose cyclophosphamide (CTX) treatment after pulse therapy attenuate paraquat (PQ)-induced lung injury in rats. Methods: PQ (25 mg/kg) was administered intraperitoneally to induce PQ-intoxicated rat model. The rats were randomly divided into four groups: control group (1 mL/day saline solution for 14 days), PQ group (1 mL/day saline solution for 14 days after PQ exposure), pulse group (15 mg/kg/day CTX in 1 mL of saline solution for 2 days and subsequent 1 mL/day saline solution for 12 days), and prolonged low-dose group (15 mg/kg/day CTX in 1 mL of saline solution for 2 days and subsequent 1.5 mg/kg/day CTX in 1 mL of saline solution for 12 days). A 14-day follow-up was conducted to determine the survival rat, and lung hydroxyproline (HYP), wet-to-dry weight ratios (W/Dc) and histopathological changes were evaluated. Results: Results showed similar survival rate (55% vs. 50%, p > 0.05) between prolonged low-dose and pulse groups. Lung W/Dc ($4.94{\pm}0.38$ vs. $5.47{\pm}0.28$, p < 0.01), HYP ($3.34{\pm}0.29{\mu}g/mg$ vs. $3.65{\pm}0.19{\mu}g/mg$, p < 0.001), and fibrosis score ($2.69{\pm}0.84$ vs. $3.13{\pm}0.63$, p < 0.05) were lower in prolonged low-dose group than those in the pulse group. Conclusions: These findings suggested prolonged low-dose CTX treatment after pulse therapy could attenuate PQ-induced lung injury in rats.

Optimization of Non-Local Means Algorithm in Low-Dose Computed Tomographic Image Based on Noise Level and Similarity Evaluations (노이즈 레벨 및 유사도 평가 기반 저선량 조건의 전산화 단층 검사 영상에서의 비지역적 평균 알고리즘의 최적화)

  • Ha-Seon Jeong;Ie-Jun Kim;Su-Bin Park;Suyeon Park;Yunji Oh;Woo-Seok Lee;Kang-Hyeon Seo;Youngjin Lee
    • Journal of radiological science and technology
    • /
    • v.47 no.1
    • /
    • pp.39-48
    • /
    • 2024
  • In this study, we optimized the FNLM algorithm through a simulation study and applied it to a phantom scanned by low-dose CT to evaluate whether the FNLM algorithm can be used to obtain improved image quality images. We optimized the FNLM algorithm with MASH phantom and FASH phantom, which the algorithm was applied with MATLAB, increasing the smoothing factor from 0.01 to 0.05 with increments of 0.001 and measuring COV, RMSE, and PSNR values of the phantoms. For both phantom, COV and RMSE decreased, and PSNR increased as the smoothing factor increased. Based on the above results, we optimized a smoothing factor value of 0.043 for the FNLM algorithm. Then we applied the optimized FNLM algorithm to low dose lung CT and lung CT under normal conditions. In both images, the COV decreased by 55.33 times and 5.08 times respectively, and we confirmed that the quality of the image of low dose CT applying the optimized FNLM algorithm was 5.08 times better than the image of lung CT under normal conditions. In conclusion, we found that the smoothing factor of 0.043 among the factors of the FNLM algorithm showed the best results and validated the performance by reducing the noise in the low-quality CT images due to low dose with the optimized FNLM algorithm.

Effects of Low-Dose Fractionated Total Body Irradiation on Murine Immune System (마우스에서 전신 저선량 분할 방사선 조사에 의한 면역학적 변화 평가)

  • Kim, Mi-Hyoung;Rhu, Sang-Young;Lim, Dae-Seog;Song, Jie-Young
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.3
    • /
    • pp.134-141
    • /
    • 2014
  • Along with the wide use of radiotherapy in cancer treatment, there is growing interest in beneficial effect of low-dose irradiation (LDI) in cancer therapy. Therefore, we investigate how LDI affects immune responses in mice model. Total body irradiation (TBI) on C57BL/6 mice was given at low-dose rate of $1mGy{\cdot}min^{-1}$ using $^{137}Cs$ source at three times for consecutive three days. Hematological examination, total cell numbers of spleen, populations and characteristics of splenocytes were determined. Total numbers of RBC or platelet in irradiated mice showed no significant changes. WBC counts were decreased in a dose-dependent manner 2 days after TBI, however, these differences are gradually waned until 28 days. Dose-dependent decrease in the number of splenocytes of TBI mice at day 2 was also improved as time progressed. While the level of Foxp3 mRNA was decreased, the frequency of $CD4^+$ T cells and $CD69^+$ cells in spleen was increased at day 2 and 14. Fractionated low-dose TBI on mice exhibited normal body weight with no distinguishable behavior during whole experimental periods. These results suggest that some parameters of immune system could be altered and evaluated by fractionated low-dose TBI and be used to broaden boundary of low dose radiation research.

Long-term Outcomes of Gamma Knife Stereotactic Radiosurgery of Vestibular Schwannomas

  • Kim, Kang-Min;Park, Chul-Kee;Chung, Hyun-Tai;Paek, Sun-Ha;Jung, Hee-Won;Kim, Dong-Gyu
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.4
    • /
    • pp.286-292
    • /
    • 2007
  • Objective : Gamma Knife Stereotactic Radiosurgery (GK SRS) has become an important treatment modality for vestibular schwannomas. We evaluated the tumor control rate, patterns of tumor volume change and preservation of hearing following low-dose radiation for vestibular schwannomas in a homogeneous cohort group in which the mean marginal dose was 12 Gy. Methods : A total of 59 patients were enrolled in this study. All enrolled patients were followed-up for at least 5 years and the radiation dose was 11-13 Gy. Regular MRI, audiometry and clinical evaluations were done and tumor volumes were obtained from MRI using the OSIRIS program. Results : The tumor control rate was 97%. We were able to classify the patterns of change in tumor volume into three categories. Transient increases in tumor volume were detected in 29% of the patients and the maximum transient increase in tumor volume was identified at 6 to 30 months after GK SRS. The transient increases in tumor volume ranged from 121% to 188%. Hearing was preserved in 4 of the 12 patients who had serviceable hearing prior to treatment. There were no other complications associated with GK SRS. Conclusion : Low-dose GK SRS was an effective and safe mode of treatment for vestibular schwannomas in comparison to the previously used high-dose GK SRS. Transient increases in tumor volume can be identified during the follow-up period after low-dose GK SRS for vestibular schwannomas. Physicians should be aware that these increases are not always indicative of treatment failure and that close observation is required following treatments. Unfortunately, a satisfactory hearing preservation rate was not achieved by reducing the radiation dose. It is thought that hearing preservation is a more sophisticated problem and further research is required.

Evaluation of Adult Lung CT Image for Ultra-Low-Dose CT Using Deep Learning Based Reconstruction

  • JO, Jun-Ho;MIN, Hyo-June;JEON, Kwang-Ho;KIM, Yu-Jin;LEE, Sang-Hyeok;KIM, Mi-Sung;JEON, Pil-Hyun;KIM, Daehong;BAEK, Cheol-Ha;LEE, Hakjae
    • Korean Journal of Artificial Intelligence
    • /
    • v.9 no.2
    • /
    • pp.1-5
    • /
    • 2021
  • Although CT has an advantage in describing the three-dimensional anatomical structure of the human body, it also has a disadvantage in that high doses are exposed to the patient. Recently, a deep learning-based image reconstruction method has been used to reduce patient dose. The purpose of this study is to analyze the dose reduction and image quality improvement of deep learning-based reconstruction (DLR) on the adult's chest CT examination. Adult lung phantom was used for image acquisition and analysis. Lung phantom was scanned at ultra-low-dose (ULD), low-dose (LD), and standard dose (SD) modes, and images were reconstructed using FBP (Filtered back projection), IR (Iterative reconstruction), DLR (Deep learning reconstruction) algorithms. Image quality variations with respect to varying imaging doses were evaluated using noise and SNR. At ULD mode, the noise of the DLR image was reduced by 62.42% compared to the FBP image, and at SD mode, the SNR of the DLR image was increased by 159.60% compared to the SNR of the FBP image. Based on this study, it is anticipated that the DLR will not only substantially reduce the chest CT dose but also drastic improvement of the image quality.

Radiation Exposure from Nuclear Power Plants in Korea: 2011-2015

  • Lim, Young Khi
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.4
    • /
    • pp.222-228
    • /
    • 2017
  • Background: On June 18, 2017, Korea's first commercial nuclear reactor, the Kori Nuclear Power Plant No. 1, was permanently suspended, and the capacity of nuclear power generation facilities will be adjusted according to the governments denuclearization policy. In these circumstances, it is necessary to assess the quality of radiation safety management in nuclear power plants in Korea by evaluating the radiation dose associated with them. Materials and Methods: The average annual radiation dose per unit, the annual radiation dose per person, and the annual dose distribution were analyzed using the radiation dose database of nuclear reactors for the last 5 years. The results of our analysis were compared to the specifications of the Nuclear Safety Act and Medical Law in Korea. Results and Discussion: The annual average per unit radiation dose of global major nuclear power generation was 720 man-mSv, while that of Korea's nuclear power plants was 374 manmSv. No workers exceeded 50 mSv per year or 100 mSv in 5 years. The individual radiation dose according to occupational exposure was 0.59 mSv for nuclear workers, 1.77 mSv for non-destructive workers, and 0.8 mSv for diagnostic radiologists. Conclusion: The radiation safety management of nuclear power plants in Korea has achieved the best outcomes worldwide, which is considered to be the result of the as-low-as-reasonably-achievable (ALARA) approach and strict radiation safety management. Moreover, the occupational exposures were also very low.

Bioavailabilities of Omeprazole Administered to Rats through Various Routes

  • Choi, Mi-Sook;Lee, Young-Hee;Shim, Chang-Koo
    • Archives of Pharmacal Research
    • /
    • v.18 no.3
    • /
    • pp.141-145
    • /
    • 1995
  • Omeprazole, a proton pump inhibitor, was given intravenously (iv), orally (po), intraperitoneally (ip), hepatoportalvenously (pv), and intrarectally (ir) to rats at a dose of 72mg/kg in order to investigate the bioavailability of the drug, The extent of bioavailabilities of omeprazole administered through pv, ip, po, and ir routes were 88.5, 79.4, 40,8, and 38.7%, respectively. Pharmacokinetic analysis in this study and literatures (Regardh et al., 1985 : Watanabe et al., 1994) implied significant dose-dependency in hepatic first-pass metabolism, clearance and distribution, and acidic degradation in gastric fluid. The high bioavailability from the pv administration (88.5%) means that only 11.5% of dose was extracted by the first-pass metabolism through the liver at this dose (72 mg/kg). The low bioavailability from the oral administration (40.8%) in spite of minor hepatic first-pass extraction indicates low transport of the drug from GI lumen to portal vein. From the literature (Pilbrant and Cederberg, 1985), acidic degradation in gastric fluid was considered to be the major cause of the low transport. Thus, enteric coating of oral preparations would enhance the oral bioavailability substantially. The bioavailability of the drug from the rectal route, in which acidic degradation and hepatic first-pass metabolism may not occur, was low (38.7%) but comparable to that from the oral route (40.8 %) indicating poor transport across the rectal membrane. In this case, addition of an appropriate absorption enhancer would improve the bioavailability. Rectal route seems to be an possible alternative to the conventional oral route for omeprazole administration.

  • PDF