• Title/Summary/Keyword: Low Dose

Search Result 2,926, Processing Time 0.036 seconds

The Optimization Experience of Occupational Exposure during Unclear Power Plant Outage (원자력발전소 계획예방정비 기간중 피폭최적화 경험)

  • Song, Young-Il;Kim, Hyung-Jin;Park, Hun-Kook;Kim, Hee-Geun
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.2
    • /
    • pp.145-154
    • /
    • 2003
  • By optimizing the radiation protection the collective dose and individual dose could be reduced during YGN #4 $5^{th}$ outage in 2001. The collective doses for the two high radiation jobs decreased to 85% and 65% of expected doses. The proportion of workers with low dose (below 1mSv) exposure increased 4% while the proportion of workers with over 3mSv and 5mSv exposure are decreased to 2%, 1% respectively. But none is exposed over 8mSv for the annual dose. To aid decision of utilizing the robot, cost- benefit analysis was performed and reasonable point was proposed to use the robot. For the first time job, repeated ALARA meeting and mock up training were implemented to set up working procedure by identifying the trouble. To easily set up standard procedure, mockup process was videotaped and reviewed during ALARA meeting. Monitoring is a good approach to chase radiological working condition such as working time, dose rate. behavior of workers, especially for high radiation work. Those data were estimated and adjusted from the stage of work planning to mock up. At the stage of actual work the monitoring data were compared to the estimation and recorded to database. This database will not only be used as a powerful tool for dose optimization at the following outage but also as a guideline to dose constraint set up for optimization for each specific situation.

PIXEL-BASED CORRECTION METHOD FOR GAFCHROMIC®EBT FILM DOSIMETRY

  • Jeong, Hae-Sun;Han, Young-Yih;Kum, O-Yeon;Kim, Chan-Hyeong;Ju, Sang-Gyu;Shin, Jung-Suk;Kim, Jin-Sung;Park, Joo-Hwan
    • Nuclear Engineering and Technology
    • /
    • v.42 no.6
    • /
    • pp.670-679
    • /
    • 2010
  • In this paper, a new approach using a pixel-based correction method was developed to fix the non-uniform responses of flat-bed type scanners used for radiochromic film dosimetry. In order to validate the method's performance, two cases were tested: the first consisted of simple dose distributions delivered by a single port; the second was a complicated dose distribution composed of multiple beams. In the case of the simple individual dose condition, ten different doses, from 8.3 cGy to 307.1 cGy, were measured, horizontal profiles were analyzed using the pixel-based correcton method and compared with results measured by an ionization chamber and results corrected using the existing correction method. A complicated inverse pyramid dose distribution was made by piling up four different field shapes, which were measured with GAFCHROMIC$^{(R)}$EBT film and compared with the Monte Carlo calculation; as well as the dose distribution corrected using a conventional method. The results showed that a pixel-based correction method reduced dose difference from the reference measurement down to 1% in the flat dose distribution region or 2 mm in a steep dose gradient region compared to the reference data, which were ionization chamber measurement data for simple cases and the MC computed data for the complicated case, with an exception for very low doses of less than about 10 cGy in the simple case. Therefore, the pixel-based scanner correction method is expected to enhance the accuracy of GAFCHROMIC$^{(R)}$EBT film dosimetry, which is a widely used tool for two-dimensional dosimetry.

Evaluation of Radiation Dose according to Aneurysm Size and Location during Cerebral Aneurysm Coil Embolization (뇌동맥류 코일 색전술 시술 시 동맥류 크기 및 위치에 따른 방사선량 평가)

  • An, Hyun
    • Journal of radiological science and technology
    • /
    • v.45 no.5
    • /
    • pp.407-412
    • /
    • 2022
  • Cerebral aneurysm coil embolization has the advantages of accurate, low patient burden, and fast recovery time, but efforts are needed to reduce dose due to the burden of exposure radiation dose during interventional procedures. In this study, the area dose product(DAP/Gy·cm2) and fluoro time(min) according to the size of the aneurysm and the location of aneurysm were investigated according to insurance recognition regulations aneurysm classification cerebral aneurysm coil embolization. According to the research method, classification according to the size and location of the aneurysm is first, the size of the aneurysm is divided into less than 4mm, more than 4mm to less than 8mm, and more than 8mm, and second, the dose to the area based on the location site (DAP/Gy·cm2) and fluoro time(min) based on the location site were observed. As a result, the location of the cerebral aneurysm procedure was found to be the Paraclinoid site. During cerebral aneurysm coil embolization, the area dose was 107 Gy·cm2 and fluoro time was 47.41 minutes, showing lower results than domestic studies, and when comparing the area dose product with foreign studies, the area dose product results were similar to that of Turkey and Saudi Arabia. It is expected that it can be used as an objective analysis indicator to establish diagnostic reference levels (DRLs) and patient radiation defense guidelines according to the size of cerebral aneurysm and location of cerebral aneurysm procedures during interventional procedures.

Study on the Crosslinking Characteristics of LDPE and LLDPE by $\gamma$-Ray Irradiation ($\gamma$-선 조사에 의한 LDPE, LLDPE의 가교특성에 관한 연구)

  • 김정일;박성현;강필현;노영창
    • Polymer(Korea)
    • /
    • v.25 no.5
    • /
    • pp.657-664
    • /
    • 2001
  • In this study. the effects of ${\gamma}$-irradiation on the crosslinking of low density poly ethylene (LLDPE) and linear low density polyethylene (LLDPE) containing crosslinking agents were investigated to find the degree of crosslinking in the polymer. The LDPE and LLDPE specimens were prepared by blending crosslinking agents with each polymers, and by hot-press-molding into a sheet at 13$0^{\circ}C$. The ${\gamma}$-irradiation was conducted at 50 to 150 kGy in nitrogen. The crosslinking percentage in these specimens was measured in relation to the irradiation dose and the type of crosslinking agents. The mechanical properties, thermal properties and crystallinity of specimens were examined as a function of irradiation dose as well. It was found that the degree of crosslinking of the irradiated specimens was increased with increasing irradiation dose and by the addition of crosslinking agents. The mechanical properties and thermal properties of specimens were improved in proportion to an increase in the degree of crosslinking. The crystallinity of original resin was decreased with increasing crosslinking density.

  • PDF

The Effects of Cynomorium songaricum on the Reproductive Activity in Male Golden Hamsters

  • Lee, Jee Soo;Oh, Hyun Ah;Kwon, Ji Young;Jeong, Min Ho;Lee, Jong Seok;Kang, Dong Won;Choi, Donchan
    • Development and Reproduction
    • /
    • v.17 no.1
    • /
    • pp.37-43
    • /
    • 2013
  • Cynomorium songaricum (CS) has been used in traditional Korean medicine in treating male impotence and sexual dysfunction. We investigated the effects of aqueous CS extract on the reproductive activity of golden hamsters whose spermatogenetic capacity is active in summer and inactive in winter. The animals were divided into 5 groups: long photoperiod (LP) control, short photoperiod (SP) control, and SP animals treated with low, middle, or high concentrations of CS. The animals were orally ingested with low (0.5 g/kg), middle (1.0 g/kg), or high (2.5 g/kg) concentrations of the aqueous extracts for 8 weeks on the daily basis. The control animals received the vehicle. As results, the LP control animals showed active testicular function but SP control animals displayed remarkably reduced testicular weights. The outcomes of the reproductive activity from low and middle concentrations of CS treatments were identical and marked as low dose. The consequences were a partial blocking of regressing activity by SP. On the other hand, the animals treated with high dose of CS extract showed remarkable significance in comparison to the SP control, indicative of a complete blocking effect of the CS on the regressing testes by SP. There were a dose-dependent effects of the CS on the sexual function. These results suggest that the CS extract promotes the male fertility by strengthening the spermatogenesis in the golden hamsters.

The Comparison on Treatment Method of Liquid Radioactive Waste in Yonggwang #3&4 and #5&6 (영광 3&4와 5&6호기에서 액체 방사성폐기물 처리방법의 비교)

  • Yeom, Yu-Seon;Kim, Soong-Pyung;Lee, Seung-Jin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.3
    • /
    • pp.219-230
    • /
    • 2004
  • Most of the low-level liquid radioactive wastes generated from PWR plants are classified into high or low total suspended solid(HTDS or LTDS), and into radiochemical and radioactive laundry waste. Although the evaporation process has a high decontami- nation ability, it has several problems such as corrosion, foam, and congestion. A new liquid waste disposal process using the ion-exchange demineralizer(IED), instead of the current evaporation process, has been introduced into the Yonggwang NPP #5 and 6. These two methods have been compared to understand the differences in this study. Aspects compared here were the released radioactivity amount of the liquid radioactive wastes, the dose of off-site residents, the decontamination factor, and the amount of the solid radioactive wastes. The IED system is designed to discharge higher radioactivity about 20% than the evaporating system, and the actual radioactivity released from the evaporating and IED system were 0.473mCi and 1.098mCi, respectively. The radioactivity released from the IED was 2.32 times higher than that of the evaporating system. The dose of off-site residents was $2.97{\times}10^{-6}$mSv for the evaporating system, and $6.47{\times}10^{-6}$mSv for IED. The decontamination factor(DF) of the evaporator is, in most cases, far lower than the lower limits of detection(LLD) with the Ge-Li detector. Due to the low concentration of the liquid wastes collected from the liquid waste system, the decontamination factor of IED is very low. Since there is not enough data on the amount of solid radioactive wastes generated by the evaporation system, the comparison on these two systems has been conducted on the basis of the design, and the comparison result was that the evaporating system generated more wastes about 40% than IED.

  • PDF

Tolerability and Effect of Early High-Dose Amino Acid Administration in Extremely Low Birth Weight Infants

  • Choi, Jin Wha;Kim, Jisook;Ahn, So Yoon;Chang, Yun Sil;Park, Won Soon;Sung, Se In
    • Neonatal Medicine
    • /
    • v.25 no.4
    • /
    • pp.153-160
    • /
    • 2018
  • Purpose: The aim of this study is to examine the tolerability and effect of early high-dose amino acid administration in extremely low birth weight infants (ELBWIs). Methods: This retrospective cohort study included ELBWI (birth weight <1,000 g, n=142). Biochemical, nutritional, and neurodevelopmental data were compared between infants who received conventional low amino acid (LAA; 1.5 g/kg/day) and those who received high amino acid (HAA; 3 g/kg/day) within the first 48 hours after birth. Neurodevelopmental data included weight, height, and head circumference at discharge, 12 to 14 and 18 to 24 months of corrected age and the Korean Bayley Scale of Infant Development II (K-BSID-II) score at 18 to 24 months of corrected age. Results: The HAA group demonstrated higher peak plasma albumin ($3.0{\pm}0.4$ vs. $3.2{\pm}0.5$, P<0.05) and lower serum creatinine ($1.7{\pm}0.9$ vs. $1.4{\pm}0.8$, P<0.05) during the first 14 days than the LAA group. Full enteral feeding was achieved significantly earlier in infants in the HAA group than in infants in the LAA group ($46.2{\pm}23.0days$ vs. $34.3{\pm}21days$, P<0.01). There was no difference between the two groups in the z score changes in all growth indicators from birth to discharge and at 12 to 14 and 18 to 24 months of corrected age, as well as in the K-BSID-II score at 18 to 24 months of corrected age. Conclusion: Aggressive administration of amino acids during the first 2 days of life in ELBWI was well tolerated and correlated with earlier full enteral feeding, but did not improve growth and neurodevelopment.

Chromosome Aberrations and Sister Chromatid Exchanges of Hospital Workers Exposed to Radiation (방사선취급 병원근무자들의 염색체이상 및 자매염색분체교환 빈도)

  • Cha, Ae-Ri;Kim, Mi-Sun;Hwang, In-Kyung;Lee, Su-Ill;Cho, Byung-Mann;Kim, Don-Kyoun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.4 s.63
    • /
    • pp.616-627
    • /
    • 1998
  • In order to evaluate the cytogenetic hazard among hospital workers potentially exposed to low dose of radiation, the analysis of chromosome aberrations(CA) and sister chromatid exchanges(SCE) in lymphocytes were performed in 79 hospital workers and 79 non-exposed workers. The mean frequency of chromosomal exchange and deletion(respectively, $0.20\times10^{-2}/cell\;and\;0.39\times10^{-2}/cell$) in the exposed group were significantly higher than those$(0.07\times10^{-2}/cell\;and\;0.23\times10^{-2}/cell)$ in control group. The frequency of sister chromatid exchanges was 5.04/cell in the control vs. 6.57/cell in the exposed group. There were also significant differences in the mean frequencies of CA and SCE adjusted for age, sex, smoking, drinking between two groups. There were no evidence of significant increase of CA and SCE according to the department or duration of employment. But the frequency of cells having chromosome aberration was significantly higher in the exposed group than in the control group related to duration of employment. There was no dose-effect relationship between the cumulative doses and the frequency of CA and SCE. But in the case of last 1 yr cumulative dose, there were evidence of significant dose-dependant increase of chromosome type CA and percentage of cells with aberration. The result suggest that there is cytogenetic hazard in risk group like hospital workers handling low dose radiation. And the analysis CA and SCE are useful biological indicators for the exposure of low dose level of radiation.

  • PDF

Increased Genotoxicity of N'-methyl-N'-nitroguanidine by Oxidative Stress (산화적 스트레스에 의한 N'-methyl-N'-nitroguanidine의 유전독성증가)

  • Kang, Jin-Seok;Jung, Ki-Kyung;Suh, Soo-Kyung;Kim, Joo-Hwan;Lee, Hwa-Ok;Jung, Hai-Kwan;Kim, Seung-Hee;Park, Sue-Nie
    • Environmental Analysis Health and Toxicology
    • /
    • v.22 no.4
    • /
    • pp.357-366
    • /
    • 2007
  • To investigate the possible enhancement of genotoxicity in stress environment, we examined the of effect of genotoxic material in oxidative stress-induced condition using human tell line. Human lymphoblast cell line, TK6 was treated with hydrogen peroxide ($H_2O_2$) for induction of oxidative stress, and treated with N'-methyl-N'-nitroguanidine (MNNG), af a genetoxic material. We carried out MTS assay to set treatment doses. TK6 was treated with $H_2O_2$ at 6.75 (low dote) or $13.5\;{\mu}M$ (high dose) for 2 h, and treated with MNNG af 0.117 (low dose), 0.234 (middle dose), $0.468\;{\mu}M$ (high dose) for 2 h. As results, a treatment of MNNG induced DNA dam age as dose dependently. And TK6 treated with $H_2O_2$ at low as well as high dose followed by MNNG treatment showed higher DNA damage compared to MNNG alone treated groups. Malondialdehyde, as a marker of lipid peroxidation was increased in $H_2O_2$ and MNNG treated groups. Real-time RT-PCR analyses for expression of several antioxidative enzymes showed that catalase mRNA and glutathione peroxidase 1 mRNA expression were decreased in $H_2O_2$ and MNNG treated groups. Taken together, we conclude that genotoxicity induced by MNNG is enhanced in a condition of oxidative stress induced by $H_2O_2$ and it suggests that it should be associated with induction of lipid peroxidation and decrease of antioxidant enzymes.

GnRH antagonist multiple dose protocol with oral contraceptive pill pretreatment in poor responders undergoing IVF/ICSI

  • Kim, Chung-Hoon;You, Rae-Mi;Kang, Hyuk-Jae;Ahn, Jun-Woo;Jeon, Il-kyung;Lee, Ji-Won;Kim, Sung-Hoon;Chae, Hee-Dong;Kang, Byung-Moon
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.38 no.4
    • /
    • pp.228-233
    • /
    • 2011
  • Objective: To investigate the effectiveness of GnRH antagonist multiple-dose protocol (MDP) with oral contraceptive pill (OCP) pretreatment in poor responders undergoing IVF/ICSI, compared with GnRH antagonist MDP without OCP pretreatment and GnRH agonist low-dose long protocol (LP). Methods: A total of 120 poor responders were randomized into three groups according to controlled ovarian stimulation (COS) options; GnRH antagonist MDP after OCP pretreatment (group 1), GnRH antagonist MDP without OCP pretreatment (group 2) or GnRH agonist luteal low-dose LP without OCP pretreatment (group 3). Patients allocated in group 1 were pretreated with OCP for 21days in the cycle preceding COS, and ovarian stimulation using recombinant human FSH (rhFSH) was started 5 days after discontinuation of OCP. Results: There were no differences in patients' characteristics among three groups. Total dose and days of rhFSH used for COS were significantly higher in group 3 than in group 1 or 2. The numbers of mature oocytes, fertilized oocytes and grade I, II embryos were significantly lower in group 2 than in group 1 or 3. There were no significant differences in the clinical pregnancy rate and implantation rate among three groups. Conclusion: GnRH antagonist MDP with OCP pretreatment is at least as effective as GnRH agonist low-dose LP in poor responders and can benefit the poor responders by reducing the amount and duration of FSH required for follicular maturation.