• Title/Summary/Keyword: Low Dose

Search Result 2,905, Processing Time 0.035 seconds

High-radiation-exposure work in Korean pressurized water reactors

  • Changju Song;Tae Young Kong;Seongjun Kim;Jinho Son;Hwapyoung Kim;Jiung Kim;Jaeok Park;Hee Geun Kim;Yongkwon Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.5
    • /
    • pp.1874-1879
    • /
    • 2024
  • Owing to strict radiation safety management in Korean nuclear power plants (NPPs), most radiation workers receive very low radiation doses, even lower than the annual dose limit for the general public. However, the occupational dose distribution indicates that some Korean NPP workers receive a relatively higher dose than the average dose. This inequity in radiation exposure could be reduced by providing customized radiation protection measures, such as dose constraints, to workers receiving relatively higher doses. In this study, dose normalization was performed to identify the highest radiation exposure work in Korean pressurized water reactors (PWRs). The results show that most of the occupational exposure in Korean PWRs occurs during the planned maintenance period. Finally, the three highest radiation exposure tasks in Korean PWRs were identified: nozzle dam installation and removal, eddy current testing, and man-way opening and closing.

Dose-Dependent Pharmacokinetics of Acetaminophen in the Rat (아세트아미노펜 체내동태의 용량의존성에 관한 연구)

  • 이삼수;심창구;김신근
    • YAKHAK HOEJI
    • /
    • v.30 no.6
    • /
    • pp.301-305
    • /
    • 1986
  • Dose-dependent pharmacokinetics of acetaminophen was studied in the rat. Acetaminophen was injected intravenously at doses of 10, 30, 50, 100 and 200mg/kg to the adult male rats. The well-known dose-dependent pharmacokinetic behavior was found even at 30mg/kg dose. It implies that metabolism of acetaminophen in the liver, probably sulfation, is saturated at very low concentration of acetaminophen. Dosage regimen establishment based on this characteristics would be necessary even at usual does level (300-600mg/day/body).

  • PDF

N-methyl-D-aspartate (NMDA) and Non-NMDA Receptors are Involved in the Production and Maintenance of Nociceptive Responses by Intraplantar Injection of Bee Venom and Melittin in the Rat

  • Kim, Jae-Hwa;Shin, Hong-Kee
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.9 no.3
    • /
    • pp.179-186
    • /
    • 2005
  • Whole bee venom (WBV) and its major component, melittin, have been reported to induce long-lasting spontaneous flinchings and hyperalgesia. The current study was designed to elucidate the peripheral and spinal mechanisms of N-methyl-D-aspartate (NMDA) and non-NMDA receptors by which intraplantar (i.pl.) injection of WBV and melittin induced nociceptive responses. Changes in mechanical threshold and flinching behaviors were measured after the injection of WBV (0.04 mg or 0.1 mg/paw) and melittin (0.02 mg or 0.05 mg/paw) into the mid-plantar area of a rat hindpaw. MK-801 and CNQX (6-cyano-7-nitroquinoxaline-2,3-dione disodium) were administered intrathecally (i.t. $10{\mu}g$) or i.pl.($15{\mu}g$) 15 min before or i.t. 60 min after i.pl. WBV and melittin injection. Intrathecal pre- and postadministration of MK-801 and CNQX significantly attenuated the ability of high dose WBV and melittin to reduce paw withdrawal threshold (PWT). In the rat injected with low dose, but not high dose, of WBV and melittin, i.pl. injection of MK-801 effectively suppressed the decrease of PWTs only at the later time-points, but the inhibitory effect of CNQX (i.pl.) was significant at all time-point after the injection of low dose melittin. High dose WBV- and melittin-induced spontaneous flinchings were significantly suppressed by i.t. administration of MK-801 and CNQX, and low dose WBV- and melittin-induced flinchings were significantly reduced only by intraplantarly administered CNQX, but not by MK-801. These experimental flinchings suggest that spinal, and partial peripheral mechanisms of NMDA and non-NMDA receptors are involved in the development and maintenance of WBV- and melittin-induced nociceptive responses.

High and Low Dose Folinic Acid, 5-Fluorouracil Bolus and Continuous Infusion for Poor-Prognosis Patients with Advanced Colorectal Carcinoma

  • Bano, Nusrat;Najam, Rahila;Mateen, Ahmed;Qazi, Faaiza
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.8
    • /
    • pp.3589-3593
    • /
    • 2012
  • Objective: Evaluation and assessment of response rate, duration and toxicity in patients subjected to 5-FU based chemotherapy. Background: The therapeutic ratio shifts with different 5FU/LV regimens and none yet serve as the internationally accepted Gold Standard. A bimonthly regimen of high dose leucovorin is reported to be less toxic and more effective than monthly low dose regimens. We here compare therapeutic responses and survival benefit of the two regimens in poor prognosis patients with advanced colorectal carcinoma. Patients and Methods: A total of 35 patients with histologically confirmed colorectal carcinoma were subjected to de Gramont and Mayo Clinic regimen. Nineteen patients were treated with high dose folinic acid ($200mg/m^2$), glucose 5%, 5-FU ($400mg/m^2$) and 22 hr. CIV ($600mg/m^2$) for two consecutive days every two weeks. These patients had failed responses to previous chemotherapy and were above sixty years of age with poor general status. Sixteen patients (six below 60 years) with progressive disease were subjected to low dose folinic acid ($20mg/m^2$)for five days, 5FU($425mg/m^2$) injection bolus for 5 days, every five weeks. An initial evaluation was made in sixty days and responders were reevaluated at sixty days interval or earlier in case of clinical impairment. Based on positive prognosis, the therapy was continued. Evaluation of treatment response was made on the basis of WHO criteria. Results: The response rate was 44% in thirty four evaluable patients, with 4 complete responses (11.8%) and 11 (32.4%) partial responses. The two schedules were well tolerated, whereas, mild toxicity without WHO Grade ${\geq}2$ events was assessed. The response duration was extended (12 months) in a few patients with age above sixty years treated by high dose bimonthly regimen of 5FU/LV. Conclusion: The regimens are safe and effective in advanced colorectal carcinoma patients with poor general status.

14 Days Repeat Oral Dose Toxicity of Low Molecular Weight Fucoidan in Rats

  • Yoon, Hyun-Soo;Shin, Yong-Kyu;Lee, Seon-Ha;Lee, Dong-Sub;Jung, Young-Mi;Lee, Hyeung-Sik;Ku, Sae-Kwang
    • Biomolecules & Therapeutics
    • /
    • v.18 no.1
    • /
    • pp.111-121
    • /
    • 2010
  • In order to investigate the preliminary repeat oral dose toxicity and to determine the highest dosage for further 4-week repeated dose toxicity test, Low Molecular Weight Fucoidan (LMF) has been showed various pharmacological effects, was orally administered to female and male rats, once a day for 14 days at dose levels of 2,000, 1,000, 500 and 0 (vehicle control) mg/kg (body weights) in a volume of 10 ml/kg. The mortality and changes on the body weights, clinical signs, hematology, serum biochemistry and gross observations were monitored with organ weight and histopathology of principle organs. As the results of 14-day repeated oral treatment of LMF, no LMF treatment related mortalities were detected up to 2,000 mg/kg in both male and female rats, respectively. In addition, no noticeable changes on the body weight and clinical signs were detected except for significant decreases on the body weights and gains restricted to male 2,000 mg/kg treated groups as compared with male vehicle control. No meaningful changes on the organ weights, hematological, serum biochemistrical, gross and histopathological findings were observed. Therefore the highest dosage in the 4-week repeated dose toxicity test is suggested as 2,000 mg/kg in both female and male rats, respectively.

Changes of immunostimulatory effects by Immu-Forte on mice (면역기능 증강 신물질에 대한 마우스의 면역학적 및 혈액학적 변화)

  • Jung, Ji-Youn
    • Korean Journal of Veterinary Research
    • /
    • v.45 no.4
    • /
    • pp.501-505
    • /
    • 2005
  • Immu-Forte composed of chitosan, ${\beta}-glucan$, manno-oligosaccharide and pangamic acid was evaluated for its effectiveness as a nonspecific immunostimulator in mice. The effects of Immu-Forte were determined by analysis of cytokines using ELISA and phenotype of leukocyte subpopulations using monoclonal antibodies specific to mouse leukocyte differentiation antigens and flow cytometry. All T cells, all B cells, CD4 T cells, CD8 T cells, macrophages, IL-2, IL-4, IL-12 and IFN-r in Immu-Forte A-treated group increased in 1 months posttreatment and were significantly higher (p < 0.05) than that of control at 1 months posttreatment. All T cells, all B cells, CD4 T cells, CD8 T cells, macrophages and IL-2 in Immu-Forte EX-treated low and middle dose groups increased in 1 months posttreatment and were significantly higher (p < 0.05) than that of control at 1 months posttreatment. In the Immu-Forte soybean-treated group, NK cells and IL-4 were significantly higher in middle dose-treated group, and IL-2, IL-4 and IFN-r were significantly higher in low dose-treated group. In the Immu-Forte F-treated group, all T cells, all B cells, CD4 T cells, CD8 T cells, macrophages, NK cells, IL-2, IL-4, IL-12 and IFN-r in high dose-treated group and all T cells, all B cells, CD4 T cells, CD8 T cells, macrophages, IL-2, IL-4, IL-12 and IFN-r in middle dose-treated group and NK cells, IL-2, IL-4, IL-12 and IFN-r in low dose-treated group were significantly higher (p < 0.05) than that of control at 1 months posttreatment. In conclusion, this study has demonstrated that Immu-Forte had an immunostimulatory effect on mice through proliferation and activation of mouse immune cells.

Radiation Safety Exploration Using Radio-photoluminescence Dosimeter for Crookes Tubes in Junior and Senior High School in Japan

  • Akiyoshi, Masafumi;Do, Duy Khiem;Yamaguchi, Ichiro;Kakefu, Tomohisa;Miyakawa, Toshiharu
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.3
    • /
    • pp.106-111
    • /
    • 2021
  • Background: Crookes tube is utilized in junior high and high schools in Japan to study the character of electrons and current, and not for radiological education. There is no official guideline or regulation for these radiation source to the public. Therefore, most teachers have no information about the leakage of X-rays from Crookes tube. The peak energy of X-rays is approximately 20 keV, and it is impossible to measure using conventional survey meters. Materials and Methods: Each leakage dose of low energy X-rays from 38 Crookes tube in the education field, such as junior and senior high schools in Japan, was explored by the teachers in the school using radio-photoluminescence (RPL) dosimeters. Before and after the measurements, the dosimeters were sent by postal mails. Results and Discussion: At the exploration in this study, it was estimated that the 70 ㎛ dose equivalent, Hp(0.07) of X-rays from 31 Crookes tubes were smaller than 100 µSv in 10 minutes, at the distance of 1 m, where the Crookes tube was usually observed. However, the highest dose was estimated as 0.69 mSv by an equipment with the full power. Furthermore, one Crookes tube exhibited 0.62 mSv with minimum output power of the induction coil. This relatively large dose was reduced by the shorter distance of discharge electrodes of the induction coil. Conclusion: The leakage dose of low energy X-rays from 38 Crookes tube was explored using RPL dosimeters. It was estimated that the Hp(0.07) of X-rays from 31 Crookes tubes were smaller than 100 µSv in 10 minutes at the distance of 1 m, while some equipment radiated a higher dose. With this study, the provisional guideline for the safety operation of Crookes tube is established.

Evaluation of the Usefulness of Digital Tomosynthesis in the Chest (흉부영역에서 디지털 토모신테시스의 유용성 평가)

  • Jang, Dong-Hyuk;Shim, Sung-Shine;Choi, Jae-Wook;Choi, Jun-Gu
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.10
    • /
    • pp.340-348
    • /
    • 2012
  • To evaluate the usefulness of tomosynthesis in the chest area, simple radiograph, low-dose CT, and tomosynthesis examinations were performed, and their absorbed doses were compared, and finally the images were evaluated. The absorbed dose recorded with the simple Radiograph examination was $0.33{\pm}0.27$ mGy, that of low-dose CT $1.26{\pm}0.56$ mGy, and that of tomosynthesis $0.55{\pm}0.02$ mGy, which indicate significance differences in absorbed doses among the examinations(p<0.001). Based on the evaluations of the images, The simple radiograph scores were $1.66{\pm}0.72$, $1.61{\pm}0.63$, and $1.57{\pm}0.73$, respectively; low-dose CT scores were $2.92{\pm}0.26$, $2.91{\pm}0.29$, and $2.88{\pm}0.32$, respectively; and tomosynthesis scores were $2.69{\pm}0.51$, $2.76{\pm}0.43$, and $2.66{\pm}0.61$, respectively. That is, there were statistically significant differences among the examinations(p<0.001), although there was no significant difference between low-dose CT and tomosynthesis examinations. Therefore, tomosynthesis is judged to be a useful examination that can minimize radiation doses to patients during chest examinations and enhance diagnostic efficacy.

Acute Effects of Ethanol on Blood Pressure and Renal Function in Rat (Ethanol 급성투여(急性投與)가 흰쥐의 혈압(血壓)과 신기능(腎機能)에 미치는 영향(影響))

  • Bae, Gui-Sook;Park, Jae-Sik;Lee, Won-Jung
    • The Korean Journal of Physiology
    • /
    • v.15 no.2
    • /
    • pp.103-109
    • /
    • 1981
  • In order to determine the dose-response relationship of ethanol on blood pressure and renal function, 2 doses of ethanol were intubated into albino rats. For a direct measurement of arterial blood pressure, a polyethylene catheter(PE 10) was implanted in the abdominal aorta, and the other end of the catheter was pulled out of the back of the neck. The experiment was conducted after the rats recovered from the surgery. After emptying their bladders, the rats were placed in a metabolism cage. Mean arterial pressure (MAP) was measured and arterial blood samples were collected through the catheter. Following the collection of the control urine sample, 1 ml of 10 g% (low dose), or 30 g% (high dose) of ethanol/100 g BW was intubated. 1 ml of water/100 g BW was intubated into the control group. MAP and blood samples were taken every hour, and urine samples were collected every 90 min for 3 hours. Blood alcohol concentrations reached a peak at 1 hour (low dose: $105.0{\pm}7.5$, high dose: $214.7{\pm}20.2\;mg%$) and decreased linearly thereafter. Following alcohol ingestion, MAP began to decrease at 15 min and remained at a significantly low level thoughout the 3 hours experimental period(low dose: $112{\pm}2{\rightarrow}102{\pm}4$, high dose: $117{\pm}2{\rightarrow}100{\pm}8\;mmHg$). Urine Flow increased markedly during the first 90 min of ethanol ingestion (low dose: $0.88{\pm}0.20{\rightarrow}1.04{\pm}0.22$, high dose: $0.56{\pm}0.11{\rightarrow}1.35{\pm}0.18\;ml/1.5\;hr$) and decreased during the second 90 min period(low dose: $0.25{\pm}0.06$, high dose: $0.22{\pm}0.06\;ml/1.5\;hr$). Urine flow of the control group decreased gradually during the experiment $(0.88{\pm}0.10{\longrightarrow}0.59{\pm}0.09{\rightarrow}0.45{\pm}0.09\;ml/1.5\;hr)$. These results indicate that the blood-pressure-lowering and diuretic effects of ethanol are dose-related: higher doses of ethanol produce a greater decrease in blood pressure and greater diuresis.

  • PDF

Effect of Low Magnetic Field on Dose Distribution in the Partial-Breast Irradiation (부분유방 방사선조사 시 저자기장이 선량분포에 미치는 영향)

  • Kim, Jung-in;Park, So-Yeon;Lee, Yang Hoon;Shin, Kyung Hwan;Wu, Hong-Gyun;Park, Jong Min
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.208-214
    • /
    • 2015
  • The aim of this study is to investigate the effect of low magnetic field on dose distribution in the partial-breast irradiation (PBI). Eleven patients with an invasive early-stage breast carcinoma were treated prospectively with PBI using 38.5 Gy delivered in 10 fractions using the $ViewRay^{(R)}$ system. For each of the treatment plans, dose distribution was calculated with magnetic field and without magnetic field, and the difference between dose and volume for each organ were evaluated. For planning target volume (PTV), the analysis included the point minimum ($D_{min}$), maximum, mean dose ($D_{mean}$) and volume receiving at least 90% ($V_{90%}$), 95% ($V_{95%}$) and 107% ($V_{107%}$) of the prescribed dose, respectively. For organs at risk (OARs), the ipsilateral lung was analyzed with $D_{mean}$ and the volume receiving 20 Gy ($V_{20\;Gy}$), and the contralateral lung was analyzed with only $D_{mean}$. The heart was analyzed with $D_{mean}$, $D_{max}$, and $V_{20\;Gy}$, and both inner and outer shells were analyzed with the point $D_{min}$, $D_{max}$ and $D_{mean}$, respectively. For PTV, the effect of low magnetic field on dose distribution showed a difference of up to 2% for volume change and 4 Gy for dose. In OARs analysis, the significant effect of the magnetic field was not observed. Despite small deviation values, the average difference of mean dose values showed significant difference (p<0.001), but there was no difference of point minimum dose values in both sehll structures. The largest deviation for the average difference of $D_{max}$ in the outer shell structure was $5.0{\pm}10.5Gy$ (p=0.148). The effect of low magnetic field of 0.35 T on dose deposition by a Co-60 beam was not significantly observed within the body for PBI IMRT plans. The dose deposition was only appreciable outside the body, where a dose build-up due to contaminated electrons generated in the treatment head and scattered electrons formed near the body surface.