• Title/Summary/Keyword: Low Current Ripple

Search Result 281, Processing Time 0.021 seconds

New Generalized PWM Schemes for Multilevel Inverters Providing Zero Common-Mode Voltage and Low Current Distortion

  • Nguyen, Nho-Van;Nguyen, Tam-Khanh Tu
    • Journal of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.907-921
    • /
    • 2019
  • This paper presents two advanced hybrid pulse-width modulation (PWM) strategies for multilevel inverters (MLIs) that provide both common-mode voltage (CMV) elimination and current ripple reduction. The first PWM utilizes sequences that apply one switching state at the double ends of a half-carrier cycle. The second PWM combines the advantages of the former and an existing four-state PWM. Analyses of the harmonic characteristics of the two groups of switching sequences based on a general switching voltage model are carried out, and algorithms to optimize the current ripple are proposed. These methods are simple and can be implemented online for general n-level inverters. Using a three-level NPC inverter and a five-level CHB inverter, good performances in terms of the root mean square current ripple are obtained with the proposed PWM schemes as indicated through improved harmonic distortion factors when compared to existing schemes in almost the entire region of the modulation index. This also leads to a significant reduction in the current total harmonic distortion. Simulation and experimental results are provided to verify the effectiveness of the proposed PWM methods.

Ripple Analysis and Control of Electric Multiple Unit Traction Drives under a Fluctuating DC Link Voltage

  • Diao, Li-Jun;Dong, Kan;Yin, Shao-Bo;Tang, Jing;Chen, Jie
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1851-1860
    • /
    • 2016
  • The traction motors in electric multiple unit (EMU) trains are powered by AC-DC-AC converters, and the DC link voltage is generated by single phase PWM converters, with a fluctuation component under twice the frequency of the input catenary AC grid, which causes fluctuations in the motor torque and current. Traditionally, heavy and low-efficiency hardware LC resonant filters parallel in the DC side are adopted to reduce the ripple effect. In this paper, an analytical model of the ripple phenomenon is derived and analyzed in the frequency domain, and a ripple control scheme compensating the slip frequency of rotor vector control systems without a hardware filter is applied to reduce the torque and current ripple amplitude. Then a relatively simple discretization method is chosen to discretize the algorithm with a high discrete accuracy. Simulation and experimental results validate the proposed ripple control strategy.

Intelligent Control for Torque Ripple Minimization in Combined Vector and Direct Controls for High Performance of IM Drive

  • Boulghasoul, Zakaria;Elbacha, Abdelhadi;Elwarraki, Elmostafa
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.4
    • /
    • pp.546-557
    • /
    • 2012
  • In Conventional Combined Vector and Direct Controls (VC-DTC) of induction motor, stator current is very rich in harmonic components. It leads to high torque ripple of induction motor in high and low speed region. To solve this problem, a control method based on the concept of fuzzy logic approach is used. The control scheme proposed uses stator current error as variable. Through the fuzzy logic controller rules, the choice of voltage space vector is optimized and then torque and speed are controlled successfully with a less ripple level in torque response, which improve the system's performance. Simulation results trough MATLAB/SIMULINK${(R)}$ software gave results that justify the claims.

Analysis of the Commutation Phenomenon in Brushless DC Motor with Hysteresis Current Regulator (히스테리시스 전류제어기 구동 BLDCM의 전류(轉流)현상 해석)

  • Kang, Seog-Joo;Kim, Gwang-Heon;Won, Jong-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.685-688
    • /
    • 1992
  • This paper studies the commutation phenomenon in the Brushless DC Motor with the trapezoidal BEMF waveform. It is shown that the torque ripple am the speed ripple due to the phase commutation depend on driving sytem, operating speed am load condition. The effects of resistance and BEMF flat width on torque ripple are considered. Speed - torque characteristics of the motor is presented considering the phase commutation. Uncommutating current control method can attenuate the torque ripple in the low speed region, and also minimize the switching loss am switching frequency. In this paper, the commutation phenomena are verified by analytical formulation and simulation.

  • PDF

A Torque Ripple Reduction System of Induction Motor with Direct Torque Control (직접 토크제어에 의한 유도전동기 토크맥동 저감 시스템)

  • Kim Nam-Hun;Kim Min-Ho;Kim Min-Huei;Kim Dong-Hee;Hwang Don-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.276-279
    • /
    • 2001
  • Direct torque control(DTC) is known to produce quick response in ac drives. Some drawbacks of the classical DTC are the relatively large torque ripple in a low speed range and notable current pulsation during steady state. They are reflected speed response and increased acoustical noise. In this paper, The DTC quick response are preserved at transient state, while better qualify steady state performance is produced by Space Vector Modulation(SVM). It is able to reduce the acoustical noise, torque ripple and current pulsation during steady state. The system presented are closed loop stator flux and torque observer for wide speed range that inputs are currents and voltages sensing of motor terminal. Simulation results for the 2.2kw general purposed induction motor are presented and discussed.

  • PDF

A New 120Hz DC Output Ripple-Voltage Suppression Scheme Using BIFRED Converter with Unity Power Factor (단위 역률을 갖는 BIFRED 컨버터를 이용한 새로운 120Hz DC 출력 리플-전압 저감 제어 기법)

  • Kim Jung-Bum;Park Nam-Ju;Lee Dong-Yun;Hyun Dong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.542-546
    • /
    • 2004
  • This paper presents a technique to reduce the low frequency ripple voltage of the dc output in a BIFRED converter with a small-sized energy storage capacitor. The proposed pulse width control method can be effectively used to suppress the low frequency ripple appeared in the dc output and still shows generally good performance such as low THD of input line current and high power factor. Using the small-sized energy storage capacitor, it has better merits of low cost and small size than a conventional BIFRED converter. The proposed technique is illustrated its validity and effectiveness through simulations.

  • PDF

A Control Technique for 120Hz DC Output Ripple-Voltage Suppression Using BIFRED with a Small-Sized Energy Storage Capacitor

  • Kim Jung-Bum;Park Nam-Ju;Lee Dong-Yun;Hyun Dong-Seok
    • Journal of Power Electronics
    • /
    • v.5 no.3
    • /
    • pp.190-197
    • /
    • 2005
  • This paper presents a technique to reduce the low frequency ripple voltage of the dc output in a BIFRED converter with a small-sized energy storage capacitor. The proposed pulse width control method can be effectively used to suppress the low frequency ripple appeared in the dc output and still maintains generally good performance such as low THD of input line current and a high power factor. Using the small-sized energy storage capacitor, it has better merits of low cost and smaller size than a conventional BIFRED converter. The proposed technique is illustrated its validity and effectiveness through simulations.

Double Boost Power-Decoupling Topology Suitable for Low-Voltage Photovoltaic Residential Applications Using Sliding-Mode Impedance-Shaping Controller

  • Tawfik, Mohamed Atef;Ahmed, Ashraf;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.881-893
    • /
    • 2019
  • This paper proposes a practical sliding-mode controller design for shaping the impedances of cascaded boost-converter power decoupling circuits for reducing the second order harmonic ripple in photovoltaic (PV) current. The cascaded double-boost converter, when used as power decoupling circuit, has some advantages in terms of a high step-up voltage-ratio, a small number of switches and a better efficiency when compared to conventional topologies. From these features, it can be seen that this topology is suitable for residential (PV) rooftop systems. However, a robust controller design capable of rejecting double frequency inverter ripple from passing to the (PV) source is a challenge. The design constraints are related to the principle of the impedance-shaping technique to maximize the output impedance of the input-side boost converter, to block the double frequency PV current ripple component, and to prevent it from passing to the source without degrading the system dynamic responses. The design has a small recovery time in the presence of transients with a low overshoot or undershoot. Moreover, the proposed controller ensures that the ripple component swings freely within a voltage-gap between the (PV) and the DC-link voltages by the small capacitance of the auxiliary DC-link for electrolytic-capacitor elimination. The second boost controls the main DC-link voltage tightly within a satisfactory ripple range. The inverter controller performs maximum power point tracking (MPPT) for the input voltage source using ripple correlation control (RCC). The robustness of the proposed control was verified by varying system parameters under different load conditions. Finally, the proposed controller was verified by simulation and experimental results.

Design of Parallel-Operated SEPIC Converters Using Coupled Inductor for Load-Sharing

  • Subramanian, Venkatanarayanan;Manimaran, Saravanan
    • Journal of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.327-337
    • /
    • 2015
  • This study discusses the design of a parallel-operated DC-DC single-ended primary-inductor converter (SEPIC) for low-voltage application and current sharing with a constant output voltage. A coupled inductor is used for parallel-connected SEPIC topology. Generally, two separate inductors require different ripple currents, but a coupled inductor has the advantage of using the same ripple current. Furthermore, tightly coupled inductors require only half of the ripple current that separate inductors use. In this proposed work, tightly coupled inductors are used. These produce an output that is more efficient than that from separate inductors. Two SEPICs are also connected in parallel using the coupled inductors with a single common controller. An analog control circuit is designed to generate pulse width modulation (PWM) signals and to fulfill the closed-loop control function. A stable output current-sharing strategy is proposed in this system. An experimental setup is developed for a 18.5 V, 60 W parallel SEPIC (PSEPIC) converter, and the results are verified. Results indicate that the PSEPIC provides good response for the variation of input voltage and sudden change in load.

Characteristics of the Two-phase Induction Motor By the Inverter Fed Control

  • Yang Byoung-Yull;Kwon Byung-Il
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.4
    • /
    • pp.312-316
    • /
    • 2005
  • The single phase induction motor has been commonly applied to small-sized electrical appliances because of its low cost, but it has low efficiency and large torque ripple, and it is incapable of speed control. However, two-phase induction motors have small torque ripple, high efficiency and variable speed control, because they are inverter fed. In this paper, the dynamic characteristics of the two-phase induction motor, such as the torque ripple, current and speed, are analyzed by using the time-stepping finite element method, and compared with the cage-type single phase induction motor.