A Design of Air Compressor Remote Control System Using USN Technology (USN 기술을 이용한 공기압축기 원격관리 시스템 설계)

  • Hwang, Moon-Young
    • Korean Journal of Artificial Intelligence
    • /
    • v.6 no.1
    • /
    • pp.1-10
    • /
    • 2018
  • Compressed Air is an important energy source used in most factories nowadays. The automation trend using air compressor has been gradually increasing with the interest of the 4th industry in recent years. With the air compressor system, it is possible to construct the device at low cost and easily achieve automation and energy saving. In addition, With trend of FA, miniaturation and light weight manufacturing trend expand their use in the electronics, medical, and food sectors. Research method is to design the technology for the remote control of the following information as USN base. Development of flexible sensing module from real time observation module for fusion of IT technology in compressed air systems, design and manufacture of flexible sensing module, and realiability assessment. Design of real-time integrated management system for observation data of compressed air system - Ability to process observation data measured in real time into pre-processing and analysis data. This study expects unconventionally decreasing effect of energy cost that takes up 60~70% of air compressor layout and operation and maintenance management cost through USN(Ubiquitous Sensor Network) technology by using optimum operational condition from real time observation module. In addition, by preventing maintenance cost from malfunction of air compressor beforehand, maintenance cost is anticipated to cut back.

A Study on Optimal Operation Strategy for Mild Hybrid Electric Vehicle Based on Hybrid Energy Storage System

  • Bae, SunHo;Park, Jung-Wook
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.631-636
    • /
    • 2018
  • This paper proposed an optimal operation strategy for a hybrid energy storage system (HESS) with a lithium-ion battery and lead-acid battery for mild hybrid electric vehicles (mild HEVs). The proposed mild HEV system is targeted to mount the electric motor and the battery to a conventional internal combustion engine vehicle. Because the proposed mild HEV includes the motor and energy storage device of small capacity, the system focuses on low system cost and small size. To overcome these limitations, it is necessary to use a lead acid battery which is used for a vehicle. Thus, it is possible to use more energy using HESS with a lithium battery and a lead storage battery. The HESS, which combines the lithium-ion battery and the secondary battery in parallel, can achieve better performance by using the two types of energy storage systems with different characteristics. However, the system requires an operation strategy because accurate and selective control of the batteries for each situation is necessary. In this paper, an optimal operation strategy is proposed considering characteristics of each energy storage system, state-of-charge (SOC), bidirectional converters, the desired output power, and driving conditions in the mild HEV system. The performance of the proposed system is evaluated through several case studies with respect to energy capacity, SOC, battery characteristic, and system efficiency.

Efficient and User-Friendly Image Retrieval System Based on Query by Visual Keys

  • Serata, M.;Sakuma, K.;Stejic, Z.;Kawamoto, K.;Nobuhara, H.;Yoshida, S.;Hirota, K.
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2003.09a
    • /
    • pp.451-454
    • /
    • 2003
  • A new query method, called query by visual keys, is proposed to aim easy operation and efficient region-based image retrieval (RBIR). Visual keys are constructed from representative regions/subimages in a given image database, and the database is indexed with visual keys. A system on PC is presented, where text retrieval techniques are applied to the image retrieval with visual keys. Experimental results show that one retrieval is done within 4ms and that the proposed system achieves the comparable retrieval precision (with user-friendly operation and low computational cost) to conventional region based image retrieval systems

  • PDF

A Study on the Parallel Operation Strategy of Small Wind Turbine System for Battery Charging (배터리 충전을 위한 소형풍력 발전 시스템의 병렬 운전방안에 관한 연구)

  • Son, Yung-Deug;Ku, Hyun-Keun;Kim, Jang-Mok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.549-556
    • /
    • 2014
  • This study proposes a parallel operation strategy for small wind turbine systems. A small wind turbine system consists of blade, permanent magnet synchronous generator, three-phase diode rectifier, DC/DC buck converter, and the battery load. This configuration has reliability, simple control algorithm, high efficiency, and low cost. In spite of these advantages, the system stops when unexpected failures occur. Possible failures can be divided into mechanical and electrical parts. The proposed strategy focuses on the failure of electrical parts, which is verified by numerical analysis through equivalent circuit and acquired general formula of small wind power generation systems. Simulation and experimental results prove its efficiency and usefulness.

A Development of Wireless Monitoring System for Temperature Monitoring by using IR Sensor (적외선 센서를 이용한 열화상태 무선감시 시스템 개발)

  • Kim, Jihee;Kim, Sinwoo;Kang, Yongsoo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.1
    • /
    • pp.239-245
    • /
    • 2013
  • The temperature monitoring of power cable and cable junction point is the necessary link of the safe and reliable operation of the power system. Many kinds of cables and high voltage junction points are easy to exposed continuous vibrations and momentary impulse in industry field especially power plant industries. This system can predict the overheating of the electric cable interface and the possibility of all kinds of accident, and it helps for eliminating the hazards of electric cable interface and provides the effective guarantee for the safety operation. In order to avoid the faults of the inconvenience of installation and maintenance and the high cost of application, this system used small and contactless IR sensor module. The low power consumption is used in the system. The goal of this study is the low cost and on-line reliable monitoring of power cable and junction point temperature.

A Study on the Integrated Conceptual Model of Software Development Project Management System (소프트웨어 개발을 위한 통합 프로젝트 관리의 개념적 모형에 관한 연구)

  • Mun, Yong-Eun;Lee, Jae-Beom
    • Asia pacific journal of information systems
    • /
    • v.6 no.1
    • /
    • pp.241-267
    • /
    • 1996
  • The problems like exceeding estimated cost, late due-date, expensive maintenance, insuffiency of experts and low productivity are becoming emphasized related with the software development. In order to overcome these problems and to develop the highly qualified software within the limited resources, a project management tool is used. The purpose of this study is to develop a conceptual model of the project management system which can plan, analyze and control the software development projects effectively. The model is constructed with plan and track management system, cost management system and operation management system for the efficient project management. It is named by LSD-PMS : Large-scale Software Development Project Management System. We reviewed 5 cases of project management. LSD-PMS is evaluated and reviewed by the project managers in the field. It is proved that LSD-PMS is a tool which can help project managers develop software successfully given budget and time schedule. In the future, this system should be further developed as an integrated model with system implementation tools such as CASE products.

  • PDF

Development of Farm Size Dairy Feedmill System in Korea(II) -Development of the TMR Main Center- (우리나라의 낙농단지규모에 알맞는 사료가공시설의 모델개발(II) -TMR 지원시설의 모델 개발-)

  • Kim, T.W.;Park, K.K.
    • Journal of Biosystems Engineering
    • /
    • v.19 no.4
    • /
    • pp.343-357
    • /
    • 1994
  • Current commercial dairy feed has various problems in low feed productivity, inadequate formulation and higher feeding cost due to excessive capital investment and non-specialized system for the end product. To solve those problems, 6 TMR terminal models were developed in this study. The developed TMR terminal system consists of TMR terminal, TMR main center and combined system linked TMR terminal and TMR main center. 15 TMR main center models were developed to support 10, 20, 30, 40, 50 TMR terminal(30 ton/day basis) by 3 different types, and evaluated for capital investment and operation cost by the analysis of the newly developed computer program. Optimum model size is analyzed and suggested for each model. Followings are summary of this study : 1. The capital investment costs of TMR main centers were 1,600 to 3,800 million won for type 1, 2,200 to 4,500 million won for type 2 and 2,200 to 4,800 million won for type 3. Also model MACE30 or bigger were justified as the economical models. 2. The feed production costs of TMR main center models were 3,166 to 4,824 won/ton for type 1, 3,816 to 6,182 won/ton for type 2 and 3,990 to 6,263 won/ton for type 3. So feed production cost range was 3,166 to 6,263 won/ton. 3. The bigger production capacity, the less TMR main center production cost. The feed production cost of the biggest model MACE50 was 62~65% of smallest model MACE10.

  • PDF

A Study on the Evaluation of Energy Consumption of the Air Compressor (공기압축기 소비에너지 평가에 관한 연구)

  • Jang, Ji Seong
    • Journal of Drive and Control
    • /
    • v.17 no.2
    • /
    • pp.38-44
    • /
    • 2020
  • Various efforts have been initiated to reduce the energy consumption of the compressor as it is one of the approaches to saving a large portion of the fixed cost of the production site. Various results of reducing the energy consumption of the compressor have been reported, but to reduce the energy consumption of the compressors fundamentally, regular management of the compressor should ensure optimum operation. This requires periodic on-site visits by experts, but is often overlooked as a cost issue, resulting in the use of the compressor in low-efficiency conditions. Thus, it is necessary to develop a low-cost evaluation technology for compressor condition monitoring and efficiency analysis to ensure that the compressor is always driven at the optimum efficiency without imposing undue burden on the compressor user. In this study, a sensor was installed at the inlet, outlet, and power supply of the compressor, and a method for evaluating the energy consumption of the compressor using the minimum sensor was derived. The experimental results are presented to show the validity of the proposed method. It was confirmed that the energy consumption of the compressor can be easily as well as efficiently evaluated by using the method developed in this study.

A ZVT applied SRM converter (ZVT 방식을 적용한 SRM 구동용 컨버터)

  • 김원호;조정구;김종수;임근희
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.12
    • /
    • pp.106-112
    • /
    • 1996
  • A ZVT (zero voltage transition) converter for SRM (switched reluctance motor) drives is proposed in this study. By adding a ZVT-chopping switch in the front-end, all switches in the machine side converter can be operated without any chopping to regulate phase current. This allows the use of low-cost and slow-switching devices for the machine side converter. The ZVT circuitry allows high frequency operation of th echopping switch, which enhnaces the system dynamcis and phase-current ripples. High efficiency of th eintegrated converter is obtained due to low switching losses.

  • PDF

Implementation of a Low-cost Fiber Optic Gyroscope for a Line-of-Sight Stabilization System (Line-of-Sight 안정화 시스템을 위한 저가형 광자이로스코프 구현)

  • Yoon, Yeong Gyoo;Lee, Sang-Min;Kim, Jae Hyung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.2
    • /
    • pp.168-172
    • /
    • 2015
  • In general, open-loop fiber-optic gyroscopes (FOG) are less stable than closed-loop FOGs but they offer simpler implementation. The typical operation time of line-of-sight (LOS) stabilization systems is a few seconds to one hour. In this paper, a open-loop fiber optic gyroscope (FOG) for LOS applications is designed and implemented. The design goal is aimed at implementing a low cost, compact FOG with low Angle Random Walk (ARW) (< $0.03deg/\sqrt{h}$) and bias instability (< 0.25deg/h). The FOG uses an open-loop all-fiber configuration with 100M PM fiber wound on a small diameter spool. In order to get the design goal, digital signal processing techniques for signal detection, modulation control and compensation are designed and implemented in FPGA.