• 제목/요약/키워드: Louver

검색결과 134건 처리시간 0.026초

아트리움의 자연채광 성능 예측용 노모그래프 (Daylighting Performance Nomographs for Toplit Atrium)

  • 김정태;정유근
    • KIEAE Journal
    • /
    • 제3권2호
    • /
    • pp.45-50
    • /
    • 2003
  • Today, there are increasing evidences that daylight is essential for health, well-being and productivity. One of the strong contributions, which atria can make to advantages in building, is in allowing the use of daylight. This research is to develop nomographs and to evaluate the daylight performances of toplit atria with louvers. For this purpose, the evaluation models of toplit atria with well indexes of 0.5, 1.0 or 2.0 have been selected through the field surveys of atrium buildings in Seoul area. Also, weather data for solar irradiance and luminous efficacy were gathered from the recently conducted previous researches. The computer simulations were performed under clear sky conditions, using the ADELINE program, and various daylight performances were analyzed by the daylight illumination ratio. Analyzing the simulation results, solar altitude, solar azimuth, and louver angle and louver reflectance were found to be important factors affecting the daylight performance of toplit atria. Using these variables, regression equations have been formulated, and the nomographs, which may predict the daylight performances of toplit atria with louvers, were developed. The developed nomographs were validated through comparing the results of nomograph predictions to the results of scale-model experiments.

Louver-Fin 열교환기의 열전달 특성 실험 연구 (Experimental Study of Heat Transfer Performance of Louver-Fin Heat Exchanger)

  • 장근선;권영철;홍석률;김재덕;이현수;박병권
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.209-215
    • /
    • 2007
  • This study presents the air side heat transfer and friction characteristics of fin-tube heat exchangers. Variations of heat transfer performance in each row are investigated in the present work. Experiments were performed for the Louver fin-tube heat exchangers using air-enthalpy type calorimeter, which is based on air-enthalpy method described in ASHRAE standards. The air velocity was varied from 0.7 to 2.5 m/s with 0.3 m/s interval. The results are plotted in terms of Colburn j-factor and friction factor of with respect to Reynolds number in the range of 200 to 1100.

  • PDF

동시 냉난방 히트펌프용 루버핀-관 열교환기 성능 및 전열특성 실험연구 (Performance and Heat transfer Characteristics of Louver Fin-tube Heat Exchanger for Simultaneous Cooling/Heating Heat Pump)

  • 권영철
    • 한국산학기술학회논문지
    • /
    • 제8권6호
    • /
    • pp.1337-1342
    • /
    • 2007
  • 본 연구에서는 동시 냉난방 히트펌프용 열교환기의 성능평가 및 설계해석 기술의 확보를 위해 난방운전 온도조건에서 6종의 루버핀-관 열교환기의 공기측 열전달특성 및 마찰특성을 실험을 통하여 조사하였다. 실험을 위해 공기엔탈피방식의 칼로리미터와 항온수조를 이용하였다. 전열량의 증가는 핀피치보다 열수에 의해 더 크게 나타났고, 핀피치가 작을수록 열전달계수는 더 높았다. 또한 핀피치가 작을수록 열수증가에 의한 열전달계수의 증가폭이 커졌다. 핀피치와 열수변화에 대한 j-계수와 f-계수는 레이놀즈 수가 증가할수록 감소하였고, 레이놀즈 수 400부근의 영역에서 역전현상이 존재하였다.

  • PDF

복층유리 격자루버시스템의 주광특성에 관한 시뮬레이션 평가 (Evaluation on the Characteristics of Daylight Distributions of Grating Louver System in a Pair Glass by Computer Simulation)

  • 박병철;최안섭
    • 조명전기설비학회논문지
    • /
    • 제23권12호
    • /
    • pp.1-9
    • /
    • 2009
  • 최근 실내에 유입된 주광을 활용하여 인공조명의 에너지를 절감하는 광센서 조광제어시스템에 관한 연구는 유용한 주광의 유입을 위한 자동 차양장치와의 통합을 중심으로 이루어지고 있다. 기존의 연구는 자동 롤러쉐이딩시스템과 베니션블라이드에 관한 연구로, 이 두 시스템은 주광의 입사를 수직적으로 계산한 일영각을 기준으로 차양장치의 높이 및 각도를 계산하여 제어하고 있다. 본 연구는 광센서 조광제어시스템과 연동을 위한 새로운 차양장치로 주광의 유입을 수직 수평으로 제어하는 복층유리 격자루버시스템을 제안하고, 창면의 위치에 따른 루버의 간격을 산출하였으며, 컴퓨터 시뮬레이션을 통하여 격자루버시스템의 주광유입특성을 분석하고 평가하였다.

사무소 건물의 외피요소가 냉난방 및 조명에너지 소비에 미치는 영향에 관한 연구 (A Study on the Effect of Envelope Factors on Cooling, Heating and Lighting Energy Consumption in Office Building)

  • 손장희;양인호
    • 조명전기설비학회논문지
    • /
    • 제26권2호
    • /
    • pp.8-17
    • /
    • 2012
  • The objective of this study is to perform an analysis of the heat(heating and cooling) and lighting energy consumption according to the window area ratio and the application of horizontal louver, which is external shading device installed for the purpose of energy savings in office buildings. For this, a building was chosen as a typical example, and the heat and lighting energy consumption was calculated by using the daylight and building energy analysis simulation. The results showed that the total energy consumption, when the lighting control was applied, was reduced by an average of 11.49[%] compared to when there was no lighting control. The smaller the glazing ratio is, the less the total energy consumption is. Also, the application of the horizontal louver increases the total energy consumption under the same condition of glazing ratio.

전기집진장치의 효율 개선을 위한 풍속 분포 및 입자농도 분포의 영향 (Influence of the Distribution of Wind Velocity and Mist Concentration for the Improvement of Efficiency with an Electrostatic Precipitator)

  • 임헌찬;이덕출
    • 한국안전학회지
    • /
    • 제13권4호
    • /
    • pp.155-161
    • /
    • 1998
  • Recently, there are widely needs of small scale electrostatic precipitator(ESP) in machine shop and other factories. Since the space of such factories is limited, the improvement of collection efficiency is predominant subject. In this study, we examine the influence of distribution of wind velocity and oil mist concentration inside the ESP in order to improve the performance of the ESP. The distribution of wind velocity and mist concentration is measured respectively in a cross-sectional plane of the ESP. The former is controlled by using a louver which is placed in front of an ionizer and the latter is controlled by lengthening the pipe of entrance of the ESP in order to have plenty of time that mist is dispersed evenly. It is shown that the uniformity of distribution of wind velocity and mist concentration inside the ESP can be getting by adopting a louver with proper shape and lengthening the pipe of entrance and is also contributed to collection efficiency considerably.

  • PDF

휜-관 열교환기에 있어서 각종 휜 형상의 성능 특성에 관한 실험적 연구 (Experimental study of performance characteristics of various fin types for fin-tube heat exchanger)

  • 윤백;김영생;박환영;박현연
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.484-491
    • /
    • 1999
  • Air side heat transfer and pressure drop for ø9.52 fin-tube heat exchanger with various types of slit and louver fins were measured, and compared with wave-slit fin. Longitudinal and transverse tube spacings of the heat exchangers are 21.65mm and 25mm respectively. Actual heat exchanger was tested using water, and the tests were performed for 2 row heat exchangers with 3 different fin spacings, 1.3, 1.5 and 1.7mm. The overall performance of the enhanced fins was evaluated by comparing heat transfer coefficient with respect to fan power.

  • PDF

서리성장에 따른 이산화탄소용 마이크로채널 증발기의 성능에 관한 해석적 연구 (Analysis Study of Performance of CO2 Microchannel Evaporator According to Frost Growth)

  • 신은성;조홍현
    • 설비공학논문집
    • /
    • 제24권10호
    • /
    • pp.724-732
    • /
    • 2012
  • The microchannel evaporator with louver fin using carbon dioxide are analyzed according to the frost growth. To predict the performance of microchannel evaporator with the frost growth under low temperature, the simulation condition of previous studies was applied. As a result, the frost thickness increases and its increasing rate is reduced when the operating time increases. Frost thickness increases gradually below the quality of 0.74, and then it decreases rapidly. In addition, the frost growth of present model under same surface temperature is very similar trends with Moallem's test results. In case of low temperature application, the dimensionless frost thickness increases dramatically and it is about 0.86 after 10 minutes.

WIND DRIVEN RAIN IMPACT ON A TALL BUILDING FACADE

  • Kim, Jong-Dae;Oh, Jung-Keun;Park, Byong-Keun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.242-246
    • /
    • 2010
  • To determine the trajectories and the impact of rain drops on the facade of a tall building, a particle tracking method is employed form steady state simulation of turbulent flow around the building. The simulation is performed for the upper part of the building comprising a detailed louver system. Rain is trapped at relative high rates on the roof and the penthouse, with Local Intensity Factors (LIF's) of the order of 1. The upper parapets and upper floors get a fair amount of wetting with LIF's of the order of 0.6. The wetting decreases downwards reaching values of 0.2 to 0.25 at the level of the louver system.

  • PDF

와류 생성기가 설치된 핀 튜브 열교환기의 열 유동해석 (Flow Analysis of Heat Exchanger with Delta Winglet Vortex Generators on CFD)

  • 황성원;정지환
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1166-1171
    • /
    • 2009
  • Fin-tube heat exchangers are widely used in refrigeration systems. To improve the performance of fin-tube heat exchangers, the shape of plain fin was developed in slit fin and louver fin. These pins have higher heat transfer performance as well as larger pressure drop. Recent studies of a delta winglet vortex generators(DWVG) show less heat transfer capacity than louver fin. However, the DWVG have very small pressure drop. This paper compares the performance for the plain fin and DWVG fin in terms of flow characteristics and heat transfer based on CFD analyses. The DWVG generate vortex and delayed flow separation and leads to a reduction of a wake region behind a tube. The results show that the DWVG produce improved heat transfer and reduced pressure drop compared to a plain fin. This result is opposite to the Reynolds analogy.