• Title/Summary/Keyword: Loud Noise

Search Result 83, Processing Time 0.033 seconds

Effects of Noise on the Masticatory Muscles (소음이 저작근에 미치는 효과)

  • Lee, Sang-Il;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.35 no.1
    • /
    • pp.49-59
    • /
    • 2010
  • The purpose of this study was to investigate short-term masticatory muscle reactions in response to simulated noise and music sound. Hypothesis of this study was that loud noise would cause increased stiffness and decreased elasticity of the masticatory muscles compared to low level of noise or identical sound level of music. Fifteen male volunteers were recruited for the study. The sound levels of noise and music used here were 60 dB and 100 dB. The experiment comprised 4 sessions, Session 1 with 100 dB of noise for the 1st day of experiment: Session 2 with 100 dB of music for the $2^{nd}$ day: Session 3 with 60 dB of noise for the $3^{rd}$ day: Session 4 with 60 dB of music for the $4^{th}$ day. Stiffness and elasticity on the anterior temporalis and superficial masseter muscles were measured with tactile sensor before and 2, 4 and 6 minutes after exposure of sound. The study indicated that, in short-term exposure of sound, there was no significant difference between noise and music at both 60 and 100 dB of sound level, but that there were partially significant differences between 60 and 100 dB of sound level regardless of sound type. This suggest that high level of sounds like 100 dB used in this study, in spite of short term exposure of several minutes, would lead to masticatory muscle contraction, especially in the masseter muscles.

Computational Analysis on the Noise Characteristics of Ship Large Duct (선박용 대형 덕트의 소음 특성 전산해석 연구)

  • Song, Jee-Hun;Hong, Suk-Yoon;Lee, Yi-Soo;Kwon, Hyun-Wung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.6
    • /
    • pp.751-758
    • /
    • 2015
  • Noise prediction for HVAC(Heating, Ventilating and Air Conditioning) systems are normally performed by empirical method suggested by NEBB(National Environmental Balancing Bureau, 1994). However, the method is not suitable for large ducts in ships. In this paper, computational analysis methods are used to develop a noise prediction method for the large ducts in ships. To develop regression formula of attenuation of sound pressure level in large ducts, Boundary Element Method(BEM) is used. BEM and Computational Fluid Dynamics(CFD) are applied to the analysis of flow-induced noise in ducts with stiffeners inside. Loud noise above 100 dB can be generated in some cases. Breakout noises of large ducts are also analyzed by using BEM and Finite Element Method(FEM). The acoustic pressure level shows about 10-15dB difference between inside and outside of the duct. Utilizing the results of this study, it is expected that shipyard planners can predict noise of the HVAC system for ships.

A Survey on House Sparrow Population Decline at Bandel, West Bengal, India

  • Ghosh, Samik;Kim, Ki-Hyun;Bhattacharya, R.
    • Journal of the Korean earth science society
    • /
    • v.31 no.5
    • /
    • pp.448-453
    • /
    • 2010
  • The population of House sparrow (Passer domesticus), once a very common bird, has declined markedly in most parts of the world including India. Sparrows were distributed widely in the district Hoogly, West Bengal, India. However over the past few decades, they became not so common in this part of the wo rld. A study has been conductedto establish the database for their current population and to assess the possible causes of their decline at Bandel ($22^{\circ}$52'22''N/$88^{\circ}$22'53''E) placed beside the river Hoogly from September 2008 to May 2009. After prolonged searching, a relatively dense population of sparrow (total subject 270) was found in busy areas of railway station and a nearby market in Bandel. The behavior of these birds was studied extensively from early morning to late night. The noise level of the area varied from 35 to 95 dB with an average of 70.6 dB from 04:30 am-10:30 pm, IST. It was also observed that the sparrows took rest on the site of the tree where the illumination level was low (30-45 lux). Sparrows residing at the Bandel station are habituated with the loud noise, being undisturbed by passing trains. Thus, it can be concluded that in spite of heavy noise of trains, crowdy travelers, and lack of nest sites, they remain at the station because of availability of food in the nearby roadside market. Based on this observation, sound pollution and availability of food are not responsible for their decline.

A Study on Traveling Characteristics and Evaluation about Noise of Hydraulic Turbine Dynamo in Dam (댐 수차 발전기 소음의 전달특성과 평가에 관한 연구)

  • Yun, Jae-Hyun;Kook, Jung-Hoon;Kim, Jae-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.7
    • /
    • pp.705-711
    • /
    • 2008
  • In case of the domestic condition, as the initiating from Sumjin River Dam, total 14 units of multipurpose dams had been constructed in 1965 for the roles of flood control, waterpower generation, irrigation, water supply, industrial water supply. In the case of such multipurpose dam, it produces electric energy by converting the potential energy utilizing its head and quantity of the water into kinetic energy. However, in this process, since during the time when the turbine connected to the hydraulic turbine dynamo revolves and there occurs a loud noise, it brings the physical, mental bad influences to those people also a decline of an effective working efficiency. On such point of view, after selection of various 16 measurement points, this study has measured and analyzed the travelling characteristics of noise generated at the hydraulic turbine dynamo in Daechung Dam, and also has evaluated the degree of indoor noise using the evaluation index such as PSIL, NC. As the result of noise-evaluation, in case of Daechung Dam, since the noise damage grade appears very seriously at various spaces, it is considering that its soundproof measure would be necessitated keenly. Also, it is considered that such data could be utilized as the valuable material hereafter for establishment of an efficient noise-reduction countermeasure and a comfortable working environment for the hydraulic turbine dynamo plant.

Broadband Transmission Noise Reduction Performance of Smart Panels Featuring Piezoelectric Shunt Damping and Passive Characteristics (압전감쇠와 수동적 특성을 갖는 압전지능패널의 광대역 전달 소음저감성능)

  • 이중근;김재환
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.2
    • /
    • pp.150-159
    • /
    • 2002
  • The possibility of a broadband noise reduction of piezoelectric smart panels is experimentally studied. Piezoelectric smart panel is basically a plate structure on which piezoelectric patch with shunt circuits is mounted and sound absorbing material is bonded on the surface of the structure. Sound absorbing materials can absorb the sound transmitted at mid frequency region effectively while the use of piezoelectric shunt damping can reduce the transmission at resonance frequencies of the panel structure. To be able to tune the piezoelectric shunt circuit, the measured electrical impedance model is adopted. Resonant shunt circuit composed of register and inductor in stories is considered and the circuit parameters are determined based on maximizing the dissipated energy through the circuit. The transmitted noise reduction performance of smart panels is investigated using an acoustic tunnel. The tunnel is a square crosses sectional tunnel and a loud speaker is mounted at one side of the tunnel as a sound source. Panels are mounted in the middle of the tunnel and the transmitted sound pressure across the panels is measured. Noise reduction performance of a double smart panel possessing absorbing material and air gap shows a good result at mid frequency region except the first resonance frequency. By enabling the piezoelectric shunt damping, noise reduction is achieved at the resonance frequency as well. Piezoelectric smart panels incorporating passive method and piezoelectric shunt damping are a promising technology for noise reduction in a broadband frequency.

Transmission Noise Seduction Performance of Smart Panels using Piezoelectric Shunt Damping (압전감쇠를 이용한 압전지능패널의 전달 소음저감 성능)

  • 이중근
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.3 no.1
    • /
    • pp.49-57
    • /
    • 2002
  • The possibility of a transmission noise reduction of piezoelectric smart panels using piezoelectric shunt damping is experimentally studied. Piezoelectric smart panel is basically a plate structure on which piezoelectric patch with shunt circuits is mounted and sound absorbing materials are bonded on the surface of the structure. Sound absorbing materials can absorb the sound transmitted at mid frequency region effectively while the use of piezoelectric shunt damping can reduce the transmission at resonance frequencies of the panel structure. To be able to reduce the sound transmission at low panel resonances, piezoelectric damping using the measured electrical impedance model is adopted. Resonant shunt circuit for piezoelectric shunt damping is composed of register and inductor in series, and they are determined by maximizing the dissipated energy throughout the circuit. The transmitted noise reduction performance of smart panels is investigated using an acoustic tunnel. The tunnel is a tube with square crosses section and a loud-speaker is mounted at one side of the tube as a sound source. Panels are mounted in the middle of the tunnel and the transmitted sound pressure across panels is measured. Noise reduction performance of a smart panels possessing absorbing material and/or air gap shows a good result at mid frequency region but little effect in the resonance frequency. By enabling the piezoelectric shunt damping, noise reduction of 10dB, 8dB is achieved at the resonance frequencise as well. Piezoelectric smart panels incorporating passive method and piezoelectric shunt damping are a promising technology for noise reduction in a broadband frequency.

  • PDF

Signal Analysis of Inverter-Type Outdoor Unit for Detecting Operation Changes of Commercial Refrigerator (상업용 냉장고의 상황 감지를 위한 인버터형 실외기 신호 분석)

  • Lim, Hyo Joon;Lee, Ju Kyoung;Hwang, Jun Hyeon;Lee, Kyung Chang;Lee, Suk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.6
    • /
    • pp.517-523
    • /
    • 2016
  • Unlike household refrigerators, commercial refrigerators are composed of separate indoor and outdoor units. The outdoor unit of most commercial refrigerators is designed to run at a fixed speed, which results in low energy efficiency and loud fan noise. Moreover, it cannot respond flexibly to changing thermal load in the indoor unit. Inverter type outdoor units can address such problems through speed changes based on information obtained from the indoor unit. However, using two units from different manufacturers is often not a viable solution. If condition changes in the indoor unit can be detected without communication between the two units, it is possible to adjust the speed of the outdoor unit. This paper attempts to analyze the signal from the outdoor unit when the condition of the indoor unit changes by varying the thermal load.

The Analysis and Experiments for the Design of Electro-mechanical Variable Valve Train System (VVT용 전자식 흡/배기 밸브 시스템 설계를 위한 해석 및 실험)

  • 박승현;오성진;이종화;박경석;김도중
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.3
    • /
    • pp.60-67
    • /
    • 2001
  • As a method of variable valve train(VVT), Electro-Mechanical Valve(EMV) has been studied. Compared with conventional VVT system, the EMV system has a relatively simple structure. The system has two electromagnets, springs and an armature. The system can be operated by reciprocal action between armature and two electromagnets. And, the operating event can be controlled by electrical signal from controller. Therefore, reduction of emission and fuel consumption can be achieved through valve event control at each engine operating condition. In this study, characteristics of EMV system were investigated by simulations and experiments. The results of simulation and experiment show that the core shape and material characteristics are dominant parameters on magnetic force and delay time. In order to apply the system to commercial engine, it has a compact size and high stiffness springs(50N/mm) to increase the valve speed. Because of high valve seating velocity, loud noise and high impact force generated, which can lead to reduction of actuator durability. Therefore, further research is required to reduce valve seating velocity.

  • PDF

A Study on cooling technology of electronics communication device consoles using heat pipe exchangers (히트파이프 열교환기를 이용한 전자통신장비 콘솔의 냉각 기술에 관한 연구)

  • Choi, Jee-Hoon;Ryoo, Seong-Ryoul;Sung, Byung-Ho;Lee, Jung-Hwan;Kim, Jong-Man;Chun, Ji-Hwan;Suh, Myung-Won;Kim, Chul-Ju
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.483-486
    • /
    • 2006
  • The fan is widely used to cool high heat flux generated as of the electronic communication device consoles. It, however, makes a lot of noises that interfere considerably with the operation environment. This study was conducted to obtain the cooling design technology of the consoles through being equipped with the Heat Pipe Heat Exchangers (HPHE) together with low revolution fans in place of existing fans for the cooling technology of the forced convection. Not only the sealed type consoles but the HPHE were also designed so as to cool effectively the heat generated from the inside of the console. The simulation was conducted by computational numerical analysis along with its experiments. The results of the numerical analysis and experiments were compared in order to improve the cooling technology of the consoles mounted with the HPHE. Consequently, instead of loud fan noise generated as of existing forced convection methods, the cooling technology of HPHE can remarkably improve many problems such as the operation environment, indoor dust, malfunction caused by pollution sources and so on.

  • PDF

Acoustic and Stroboscopic Characteristics in Clergies (목사들의 음성발성에 대한 음향분석학적 특징)

  • 진성민;박상욱;강현국;이경철;이용배;김보형
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.9 no.1
    • /
    • pp.47-52
    • /
    • 1998
  • Objectives : To compare the objective differences in voice quality and voice problems between clergies and normal male control group. Materials and Methods : The sustained vowel sound of 46 clergies and 40 normal persons were analyzed, using a videostroboscopy and acoustic analyzer. Together with these analyses, a questionnaire associated with current and past voice problems was handed over to the patients. Results : The most common symptom in subjective group was the voice fatigue. Stroboscopic findings in subjective group were as following 23 cases(50%) of pachydermia, 17 cases(37%) of phase difference, 12 cases(25%) of anterior-posterior contracture, 6 cases(13%) of vocal polyp and 3 cases(7%) of vocal nodule. The mean maximal phonation time in clergies was 17.8 seconds and in control group was 19 seconds. litter, pitch perturbation quotient and shimmer were significantly increased in subjective group than in control group(p<0.05), but there were no significant differences between two groups in fundamental frequency, vFo, amplitude perturbation quotient and noise to harmonic ratio. Conclusion : In the clergies using loud and forceful voice, vocal polyp and functional voice disorder findings were frequently noted in stroboscopic examination. litter and shimmer, reflecting the roughness of voice, were increased in acoustic analysis. Therefore, clergies, classified into untrained professional voice users, need professional career guidance and counseling.

  • PDF