• Title/Summary/Keyword: Losses Analysis

Search Result 1,579, Processing Time 0.036 seconds

Comparisons of Different Step-drawdown Test Analysis Methods; Implication for Improrvced Analysis for Step-drawdown Test Data (단계양수시험 해석 방법에 따른 우물 및 수리 상수 변동 분석)

  • An, Hyowon;Ha, Kyoochul;Lee, Eunhee;Do, Byung Hee
    • Journal of Soil and Groundwater Environment
    • /
    • v.25 no.4
    • /
    • pp.35-47
    • /
    • 2020
  • Step-drawdown test is one of the widely-used aquifer test methods to evaluate aquifer and well losses. Various approaches have been suggested to estimate well losses using the step-drawdown test data but the uncertainties associated with data interpretation and analysis still exist. In this study, we applied three different step-drawdown test analysis methods -Jacob (1947), Labadie and Helweg (1975), Gupta (1989)- to the step-drawdown test data in Seobu-myeon, Hongseong-gun, South Korea and estimated aquifer and well losses. Comparisons of different step-drawdown test analysis methods revealed that the estimated well losses showed different values depending on the applied methods and these variations are likely to be related to the limitation of the assumptions for each analysis method. Based on the detailed analysis of time-drawdown data, we performed step-drawdown test analysis after removing outlier data during the initial stage of step drawdown test. The results showed that the application of the revised time-drawdown data could substantially decrease the error of the analysis as well as the variations in the estimated well losses from different analysis methods.

A Study on Eire Data Analysis in Korea, Japan and USA (2) Direct Property Losses Due to Fires (한국ㆍ일본ㆍ미국의 화재발생실태에 대한 비교분석 (2) 화재로 인한 재산피해)

  • Lee Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.1-15
    • /
    • 2004
  • The following matters were confirmed through the analysis of property losses due to fires in Korea, the U.S., and Japan. 1. Korean statistics on property losses are not the most detailed of the three centuries, and they have a lot of limitations to analyze the actual condition of property losses due to fires. 2. The percentage which takes up property losses due to fires in GDP is on the decrease in the U.S. and Japan, but increase in Korea. In addition, from 1994, it has occupied almost the same rate in Korean ad compared with the U.S. and Japan. 3. When inflation are taken into consideration, property losses due to fires in the U.S. and Japan have decreased, but in Korea, they have increased except for the recent 2 years.

Comparison on Electromagnetic Losses of Permanent Magnet Synchronous Motor/Generator according to slotted and slotless for High-speed Micro Turbine (슬롯 유무에 따른 초고속 마이크로 터빈용 영구자석 전동발전기의 손실해석 및 비교)

  • Jo, Chang-Hum;Jian, Li;Cho, Yun-Hyun;Hong, Do-Kwan;Woo, Byung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.882-883
    • /
    • 2011
  • This paper deals with comparison on Electromagnetic losses of slotted and slotless high-speed PM Machine for Micro Turbine. Losses are consist of core losses, copper losses and eddy current losses. We are using both analytical method and 2D Finite Element Method for more detailed losses analysis. And then We compare Electromagnetic losses of slotted and slotless PM synchronous machine. This machine has designed of a generator of 800W, 400000rpm and a starter of 400W, 200000rpm.

  • PDF

Performance Evaluation of Small-Scaled Wind Power Generator with Outer Permanent Magnet Rotor considering Electromagnetic Losses (2) - Electromagnetic Losses and Performance Analysis - (전자기 손실을 고려한 소형 외전형 영구자석 풍력발전기의 성능 평가 (2) - 전자기 손실 해석 및 성능 평가 -)

  • Ko, Kyoung-Jin;Jang, Seok-Myeong;Choi, Jang-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.1
    • /
    • pp.50-62
    • /
    • 2011
  • In this paper, analytical techniques for performance characteristics analysis of wind power generator with outer permanent magnet rotor are proposed. Furthermore, the proposed analytical techniques are validated by performance experiments of the manufactured generator. In this part, characteristic equations of losses such as copper loss, core loss are derived. Using the derived loss characteristic equations, electrical parameters obtained in [15] and d-q axes method, constant load and constant speed characteristics of wind power generator are analyzed. And then, to analyze performance of wind power system according to wind speed, d-q analysis model considering wind turbine characteristics is proposed. Finally, the obtained performance characteristics results are validated in comparison with those by experiments.

Measurement and Numerical Analysis of AC Loss in the HTS Pancake Coil and the HTS Solenid Coil (고온초전도 팬케이크 코일과 솔레노이드 코일의 교류손실 측정 및 수치해석)

  • Park Myung-Jin;Lee Sang-Soo;Lee Seung-Wook;Cha Guee-Soo;Lee Ji-Kwang
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.12
    • /
    • pp.732-738
    • /
    • 2004
  • In this paper, we constructed 13 turns pancake coil and solenoid coil with HTS tape and measured AC losses of the pancake coil. The critical current of the pancake coil and the solenoid coil were 80A and 109A, respectively. To compare measured AC losses of the two coils, we carried out numerical analysis using 2-D FEM program for manufactured coils. This paper presents current density distribution, flux density distribution and AC losses of the pancake coil and the solenoid. As a result, we obtained that current density distribution was closely related to the orientation of magnetic field and distribution of AC losses were also closely related to the perpendicular component of flux density distribution in coil. The calculated AC losses of the two coils showed good agreement with measured AC losses and AC losses of the pancake coil was about 9 times bigger than that of the solenoid coil under the same turns and length.

A simple and efficient data loss recovery technique for SHM applications

  • Thadikemalla, Venkata Sainath Gupta;Gandhi, Abhay S.
    • Smart Structures and Systems
    • /
    • v.20 no.1
    • /
    • pp.35-42
    • /
    • 2017
  • Recently, compressive sensing based data loss recovery techniques have become popular for Structural Health Monitoring (SHM) applications. These techniques involve an encoding process which is onerous to sensor node because of random sensing matrices used in compressive sensing. In this paper, we are presenting a model where the sampled raw acceleration data is directly transmitted to base station/receiver without performing any type of encoding at transmitter. The received incomplete acceleration data after data losses can be reconstructed faithfully using compressive sensing based reconstruction techniques. An in-depth simulated analysis is presented on how random losses and continuous losses affects the reconstruction of acceleration signals (obtained from a real bridge). Along with performance analysis for different simulated data losses (from 10 to 50%), advantages of performing interleaving before transmission are also presented.

Simulation and Analysis of Losses of Switching Device for Single Grid-connected Full bridge inverter (단상 계통 연계형 풀브릿지 인버터의 스위치 손실 모의 및 분석)

  • Son, Myeongsu;Lim, Hyun Ji;Cho, Younghoon
    • Proceedings of the KIPE Conference
    • /
    • 2017.11a
    • /
    • pp.101-102
    • /
    • 2017
  • This paper presents analysis of losses of switching device for full bridge inverter connected to grid. The losses are a dominant factor that judges efficiency of the system. The losses of switching device are divided to switching loss and conduction loss. They are can be estimated by analyzing periodic switching waveforms. The switching loss is generated at the point that turn-on and off. And the conduction loss is generated while the switch is on condition. The estimated losses of switch are compared to simulation result in this paper.

  • PDF

Analysis on Eddy Current Losses for Cylindrical Linear Oscillatory Actuator with Halbach Array according to Drive Voltage Waveform (영구자석 Halbach형 원통형 액추에이터의 구동전압 파형에 따른 와전류 손실)

  • Jang, Seok-Myeong;Kim, Hyun-Kyu;Park, Ji-Hoon;Ko, Kyoung-Jin;Choi, Jang-Young;Kim, Il-Jung
    • Proceedings of the KIEE Conference
    • /
    • 2009.04b
    • /
    • pp.49-51
    • /
    • 2009
  • This paper deals with the analysis on eddy current losses for cylindrical linear oscillatory actuator (LOA) with Halbach array mover according to voltage waveform. This paper presents analytical procedures for calculation of eddy current losses using Poynting theorem. On the basis of the magnetic vector potential and a two-dimensional (2-d) cylindrical coordinate system, this paper derived analytical solutions of eddy current tosses using phase current analysis. The eddy current losses of each harmonic obtained by fast Fourier transform (FFT) analysis of phase current are compared with results obtained from finite-element method (FEM). Particularly, this paper shows that the eddy current losses of cylindrical LOA according to square voltage waveform are more significant than those according to sinusoidal voltage waveform.

  • PDF

Analysis on the Rotor Losses in High-Speed Permanent Magnet Synchronous Motor Considering the Operating Condition (운전조건을 고려한 고속 영구자석형 동기전동기의 회전자 손실 해석)

  • Jang, Seok-Myeong;Choi, Jang-Young;Cho, Han-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.1
    • /
    • pp.48-56
    • /
    • 2007
  • In this paper, the rotor losses in high-speed permanent synchronous motor (PMSM) considering the operating condition are discussed. In order to maintain the mechanical integrity of a high-speed permanent magnet machine rotor intended for high-speed operation, the rotor assembly is often retained within a stainless steel or Carbon-Fiber/Epoxy sleeve. The sleeve is exposed to fields produced by the stator from either the slotting or the mmf harmonics that are not synchronous with rotor losses. On the basis of analytical field analysis, the rotor losses are analyzed. In particular, the no-load, rated with air-cooled, and forced water cooled conditions are considered. The results are validated extensively by comparison with non-linear finite element method (FEM).

Comparative Analysis of Power Losses for Three-Level T-Type and NPC PWM Inverters (3-레벨 T-형 및 NPC 인버터의 전력 손실 비교 분석)

  • Alemi, Payam;Lee, Dong-Choon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.173-183
    • /
    • 2014
  • In this paper, an analysis of power losses for the three-level T-type and neutral-point clamped (NPC) PWM inverters is presented, in which the conduction and switching losses of semiconductor devices of the inverters are taken into account. In the inverter operation, the conduction loss depends on the modulation index (MI) and power factor (PF), whereas the switching loss depends on the switching frequency. Power losses for the T-type and NPC inverters are analyzed and calculated at the different operating points of MI, PF and the switching frequency, in which the four different models of semiconductor devices are adopted. In the case of lower MI, the NPC-type is more efficient than the T-type, and vice versa. The validity of the power loss analysis has been verified by the simulation results.