• 제목/요약/키워드: Losses

검색결과 5,327건 처리시간 0.025초

An Improved Dynamic Programming Approach to Economic Power Dispatch with Generator Constraints and Transmission Losses

  • Balamurugan, R.;Subramanian, S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권3호
    • /
    • pp.320-330
    • /
    • 2008
  • This paper presents an improved dynamic programming (IDP) approach to solve the economic power dispatch problem including transmission losses in power systems. A detailed mathematical derivation of recursive dynamic programming approach for the economic power dispatch problem with transmission losses is presented. The transmission losses are augmented with the objective function using price factor. The generalized expression for optimal scheduling of thermal generating units derived in this article can be implemented for the solution of the economic power dispatch problem of a large-scale system. Six-unit, fifteen-unit, and forty-unit sample systems with non-linear characteristics of the generator, such as ramp-rate limits and prohibited operating zones are considered to illustrate the effectiveness of the proposed method. The proposed method results have been compared with the results of genetic algorithm and particle swarm optimization methods reported in the literature. Test results show that the proposed IDP approach can obtain a higher quality solution with better performance.

직관형 LED램프의 구성부품별 광손실에 관한 연구 (A Study on Optical Losses for Tubular LED Lamp's Components)

  • 정희석;박창규
    • 조명전기설비학회논문지
    • /
    • 제25권7호
    • /
    • pp.1-8
    • /
    • 2011
  • The high efficiency tubular LED lamp has been developed. But, it occurs optical losses in consists of LED package, module, diffuser etc.. By Measuring the tubular LED lamp's luminous flux, we compared and analyzed about the effect of optical losses for each component and actually using measured luminous intensity distribution data, illuminance distribution was simulated by Relux. Optical losses are 24[%] from LED package to luminaire and the tubular LED lamp can be replaced with fluorescent lamp. In this paper, we could provide data for optimum lighting design by analyzing the optical characteristics for developing and propagating the tubular LED lamp.

3-레벨 T-형 및 NPC 인버터의 전력 손실 비교 분석 (Comparative Analysis of Power Losses for Three-Level T-Type and NPC PWM Inverters)

  • 알레미파얌;이동춘
    • 전력전자학회논문지
    • /
    • 제19권2호
    • /
    • pp.173-183
    • /
    • 2014
  • In this paper, an analysis of power losses for the three-level T-type and neutral-point clamped (NPC) PWM inverters is presented, in which the conduction and switching losses of semiconductor devices of the inverters are taken into account. In the inverter operation, the conduction loss depends on the modulation index (MI) and power factor (PF), whereas the switching loss depends on the switching frequency. Power losses for the T-type and NPC inverters are analyzed and calculated at the different operating points of MI, PF and the switching frequency, in which the four different models of semiconductor devices are adopted. In the case of lower MI, the NPC-type is more efficient than the T-type, and vice versa. The validity of the power loss analysis has been verified by the simulation results.

송전선로의 유효전력 손실을 각 부하에 배분하는 방법 (An Approach to Allocate Real Power Losses of Transmission Lines to Individual Loads)

  • 노경수
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권1호
    • /
    • pp.13-18
    • /
    • 2000
  • The paper proposes a simple method to calculate the portion of real power losses of transmission lines allocated to individual loads. The method is implemented by defining loss distribution factors, and analyses the loads shares in the transmission line losses. The paper also performs calculation of sensitivities of the line losses with respect to load changes so as to be easily employed in on-line applications. Effectiveness of the algorithm is verified by computer simulations and it is estimated that the results can be used to compute the cost of one ancillary service under deregulated environment in electric power industries.

  • PDF

연계 계통에서의 환경적 배출량과 손실을 고려한 최적 경제급전 (Multi-Area Economic Dispatch Considering Environmental Emission and Transmission Losses)

  • 최승조;이상봉;김규호;유석구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.341-343
    • /
    • 2000
  • Traditionally electric power system are operated in such a way that the total fuel cost is minimized regardless of accounting for tie-lines transmission constraint and emissions produced. But tie-lines transmission and emissions constraint are very important issues in the operation and planning of electric power system. This paper presents the Two-Phase Neural Network(TPNN) to solve the Economic Load Dispatch (ELD) problem with tie-lines transmission and emissions constraint considering transmission losses. The transmission losses are obtained from the B-coefficient which approximate the system losses as s quadratic function of the real power generation. By applying the proposed algorithm to the test system, the usefulness of this algorithm is verified.

  • PDF

Dielectric properties of ZrTiO4 thin films deposited by DC magnetron reactive sputtering

  • Kim, Taeseok;Park, Byungwoo;Hong, Kug-Sun
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제3권2호
    • /
    • pp.130-133
    • /
    • 1999
  • Paraelectric ZrTiO4 thin films were synthesized on a Si(100) substrate using DC magnetron reactive sputtering. Films deposited above-400$^{\circ}C$ exhibited crystalline characteristics. The dielectric constants ($\varepsilon$) and dielectric losses (tan$\delta$) of as-deposited and annealed films were measured in the 1 MHz range using a Pt upper electrode and a phosphorous-doped si bottom electrode. Preliminary data showed that as the deposition temperature increased, the dielectric losses decreased while the dielectric constants did not change significantly. similar trends for dielectric losses were observed when the as-deposited samples were annealed at 800$^{\circ}C$. The reduction of dielectric losses at high-deposition temperatures and post annealing correlated well with the x-ray diffraction peak widths.

  • PDF

양수장지구 광역논으로부터 영양염류 유출 및 물질수지 (Water and Nutrient Balance of Paddy Field Irrigated from a Pumping Station)

  • 한국헌;윤광식;최진규;조재영;김영주
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2003년도 학술발표논문집
    • /
    • pp.591-594
    • /
    • 2003
  • A field monitoring study was carried out to investigate the water balance and losses of nutrients from paddy fields in Sumjin river basin. The size of paddy fields was 115 ha and the fields were irrigated from a pumping station. The runoff loading was the highest in June because of the high concentrations of nutrients due to applied fertilizer. The surface runoff losses of T-N and T-P in runoff water were 53.4 to 68.3kg/ha(average 59.7kg/ha) and 0.38 to 2.20kg/ha(average 1.42kg/ha), respectively. When the runoff losses of nutrients were compared to applied chemical fertilizer, it was found that 42% to 60% of nitrogen lost via runoff while runoff losses of phosphorus account for 3.0% to 17.2% of the total applied amount during entire year.

  • PDF

Dry friction losses in axially loaded cables

  • Huang, Xiaolun;Vinogradov, Oleg G.
    • Structural Engineering and Mechanics
    • /
    • 제4권3호
    • /
    • pp.330-344
    • /
    • 1996
  • A model of a cable comprising interacting wires with dry friction forces at the interfaces is subjected to a quasi-static cyclic loading. The first cycle of this process, comprising of axial loading, unloading and reloading is investigated analytically. Explicit load-elongation relationships are obtained for all of the above phases of the cycle. An expression for the hysteretic losses is also obtained in an explicit form. It is shown that losses are proportional to the third power of the amplitude of the oscillating axial force, and are in inverse proportion to the interwire friction forces. The results obtained are used to introduce a model of a cable as a solid rod with an equivalent stiffness and damping properties of the rod material. It is shown that the stiffness of the equivalent rod is weakly nonlinear, whereas the viscous damping coefficient is proportional to the amplitude of the oscillation. Some numerical results illustrating the effect of cable parameters on the losses are given.

손실을 고려한 초전도 동기전동기 설계 (Superconducting Synchronous Motor Design considering Machine Losses)

  • 백승규;손명환;김석환;권영길
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제3권2호
    • /
    • pp.21-26
    • /
    • 2001
  • Superconducting synchronous generators and motors are designed based on 2 dimensional electro-magnetic approach. In the case of generator, if the machine output rating and terminal voltage are decided the armature rating current will be decided automatically according to its power factor. However, in the case of motor, if the output rating is given with [hp] or [kw] units, the armature terminal voltage and current are not decided directly because the machines armature input power and mechanical output are different by way of losses. So in order to calculate the armature current more accurately. the machine losses must be included in the design procedure. In this paper the machine loss of superconducting motor are analyzed and used for decision of the armature input power and current. Moreover, the differences of voltage equations between superconducting synchronous generator and motor are considered.

  • PDF

수평자장에 대한 Bi-2223테이프의 자화손실 특성 (Magnetization Loss Characteristics of a Bi-2223 Tape in Parallel Magnetic Fields)

  • 류경우;한형주;최병주;나완수;주진호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권4호
    • /
    • pp.158-163
    • /
    • 2001
  • Magnetization losses of a Bi-2223 tape in magnetic fields parallel to the tape surface were measured by a room temperature cancellation and a cryogenic temperature cancellation. The results indicate that the same loss data are observed for both methods. The magnetization losses are hysteretic because the measured losses agree well with calculated ones based on a critical state model. In the full field penetration cases the magnetization losses increase with the frequency but in the partial field penetration cases the influence of the frequency is opposite.

  • PDF