• 제목/요약/키워드: Losses

검색결과 5,298건 처리시간 0.033초

Fe-B-Si 비정질 권철심의 경년 열화 연구 (Aging of Amorphous Fe-B-Si Wound Cores)

  • 민복기;송재성;강영호;강원구
    • 대한전기학회논문지
    • /
    • 제43권3호
    • /
    • pp.432-436
    • /
    • 1994
  • The aging characteristics of amorphous FeS178TBS113TSiS19T wound cores have been investigated as a function of aging temperature and time. The core losses(1.2T/60Hz) of amorphous wound cores dipped in transformer oil decrease in comparision with initial stage of aging test due to insulation of ribbon stacks by oil penetration. It is estimated that it takes 30 years or more for 10% increase in core losses (1.2T/60Hz) of amorphous wound cores aged at normal transformer running temperature(100$^{\circ}C$). So we condlude that the amorphous core is satisfactorily applicable to transformer.

하이브리드 방식에 의한 미시적 부하모델링 (Component-Based Load Modeling Updated by Hybrid Technique)

  • 지평식
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권3호
    • /
    • pp.179-182
    • /
    • 2003
  • Component-based method for load model not only should include the performances of the load components, but also should take into consideration the core losses of transformers, the line losses and the capacitor banks. Especially, capacitor bank affects the accuracy of reactive load model in load modeling. But it is difficult to identify actual reactive powers of capacitor banks in power system for load modeling. This research improves the component-based modeling method including uncertain capacitor bank. The proposed method is hybrid technique, which adds the measurement-based method to the existing component-based method for reliable information of capacitor band. The results of case studies were presented to verify the validity of the proposed method.

Some Problems of the Partial Discharge Burning Time

  • Kinsht Nikolay V.;Katz Marat A.
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권6호
    • /
    • pp.319-323
    • /
    • 2006
  • The problem of the partial discharge (PD) extinction is investigated. The transient process takes place in a small spherical inclusion which is located in the dielectric. Both the losses caused by polarization and ohmic losses as the dielectric parameters are taken into account. From the inclusion standpoint the dielectric is considered as an active two-pole element (equivalent generator) and inclusion represents by own current-voltage curve. PD extinction voltage was shown to depend on the polarization loss tangent.

Bi계 고온초전도 전류 리드의 특성 (Characteristics of Bi-based High $T_c$ Superconducting Current Lead)

  • 백승명;이병성;김영석;곽민환;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.73-76
    • /
    • 1999
  • We have fabricated and tested a Bi-based high temperature superconducting current lead system. Ag sheathed Bi-2223 mono-filament tapes of $I_c=8.4$ A at 77 K under self-field condition were fabricated using powder-in-tube(P1T) method. Multi-layer current leads can be made by stacking of Ag sheathed Bi-2223 mono-filament wires. The critical current of this 10-layer current lead is about 68 A. The contact resistance across the copper-current lead interface has been studied using current-voltage characteristics. At temperature below critical temperature the resistive contribution of the interface to the total contact resistance dominates. We have measured AC transport losses in a current lead at 77 K, 60 Hz by a transport method.

  • PDF

영전압, 영전류 스위칭 1단 방식 역률 보상 AC/DC 컨버터 (ZVZCS Single-Stage Power Factor Corrected Converter)

  • 강필순;박성준;권순재;김철우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1348-1350
    • /
    • 2000
  • Zero-voltage and zero-current switched single-stage approach with high power factor is presented to reduce the switching losses and to achieve sinusoidal, unity power factor input currents. This single-stage approach, which combines a boost converter used as PFC with a half-bridge converter used as do to do conversion into one power stage, has a simple structure and low cost. At the same time, since the switches of the proposed converter are designed to be turned on at zero-voltage and off at zero-current, the switching losses could be reduced considerably. Detailed analysis and experimental results are presented on the proposed converter, which is operated at constant switching frequency and in discontinuous conduction mode.

  • PDF

GA를 이용한 UPFC와 전력용 콘덴서의 최적 제어 (Optimal Control of UPFC and Switched Shunt Capacitor by Using Genetic Algorithm)

  • 김학만;김종율;오태규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.9-11
    • /
    • 2003
  • In power system planing and operation, voltage and reactive power control are very important. The voltage deviation and system losses can be reduced through control of reactive power sources. In general, there are several different reactive power sources, we used UPFC and switched shunt capacitor to improve the voltage profile and to reduce system losses in this study. Since there are many switched shunt capacitors in power system, so it is necessary to coordinate these switched shunt capacitors. In this study, Genetic Algorithm(GA) is used to find optimal coordination of UPFC and switched shunt capacitors in a local area of power system. In case study, the effectiveness of the proposed method is demonstrated in KEPCO's power system. The simulation is performed by PSS/E.

  • PDF

엑서지 해석에 기초한 메탄올합성공정의 손실예방책 연구 (A Study of Loss Prevention for Methanol Synthesis Process Based on Exergy Analysis)

  • 조효은;정연수
    • 청정기술
    • /
    • 제6권2호
    • /
    • pp.129-137
    • /
    • 2000
  • 역수성가스반응과 메탄올형성반응을 연계한 메탄올합성공정에 대한 엑서지 해석을 수행하였다. 실험자료를 이용하여 공정을 모사하였으며 공정모사의 결과를 이용하여 엑서지 해석을 수행했다. 구동엑서지 손실과 물질엑서지 손실을 각각 정의하였고 정량화 하였다. 해석결과를 바탕으로 엑서지 손실의 위치, 크기, 원인과 개선 가능방법 등을 제시하였다. 엑서지 해석은 오염방지를 위한 손실예방책을 발전시키고 나아가 산업생태학에 적용할 수 있는 타당한 과학적 근거가 될 수 있음을 알 수 있었다.

  • PDF

날개-평판 접합부에서의 날개 앞전 형상 최적화를 통한 유동특성 향상 (Improvement of the Flow Characteristics by Optimizing the Leading-Edge Shape Around Airfoil/Flat-Plate Junction)

  • 조종재;김귀순
    • 한국추진공학회지
    • /
    • 제13권6호
    • /
    • pp.24-33
    • /
    • 2009
  • 본 논문에서는 2차유동손실을 일으키는 주요 요인 중의 하나인 말굽와류의 강도를 감쇄시키기 위해 일반적인 날개 앞전의 형상을 결정하는 변수를 정하고 이를 최적화 하였다. 근사최적화 기법을 이용 최적화를 수행하였다. 유동해석과 최적화 프로그램으로는 $FLUENT^{TM}$$iSIGHT^{TM}$를 이용하였다. 최적화 수행결과, 기준 모델의 경우에 비해 최적화된 모델의 경우 전압력 계수가 약 9.79% 감소하였다.

Finite Element Study of Ferroresonance in single-phase Transformers Considering Magnetic Hysteresis

  • Beyranvand, Morteza Mikhak;Rezaeealam, Behrooz
    • Journal of Magnetics
    • /
    • 제22권2호
    • /
    • pp.196-202
    • /
    • 2017
  • The occurrence of ferroresonance in electrical systems including nonlinear inductors such as transformers will bring a lot of malicious damages. The intense ferromagnetic saturation of the iron core is the most influential factor in ferroresonance that makes nonsinusoidal current and voltage. So the nonlinear behavior modeling of the magnetic core is the most important challenge in the study of ferroresonance. In this paper, the ferroresonance phenomenon is investigated in a single phase transformer using the finite element method and considering the hysteresis loop. Jiles-Atherton (JA) inverse vector model is used for modeling the hysteresis loop, which provides the accurate nonlinear model of the transformer core. The steady-state analysis of ferroresonance is done while considering different capacitors in series with the no-load transformer. The accurate results from copper losses and iron losses are extracted as the most important specifications of transformers. The validity of the simulation results is confirmed by the corresponding experimental measurements.

접시형 태양열 집광시스템용 흡수기의 열손실 해석 (An Analysis of Heat Losses from Receivers for a Multifaceted Parabolic Solar Collector)

  • 류시열;서태범;강용혁
    • 태양에너지
    • /
    • 제20권3호
    • /
    • pp.61-73
    • /
    • 2000
  • Heat losses from receivers for a dish-type solar energy collecting system are numerically investigated. The analytical method for predicting conductive heat loss from a cavity receiver is used. The Stine and McDonald Model is used to estimate convective heat loss. Two kinds of techniques for the radiation analysis are used. The Net Radiation Method that is based on the radiation heat balance on the surface is used to calculate the radiation heat transfer rate from the inside surface of the cavity receiver to the environment. The Monte-Carlo Method that is the statistical approach is adopted to predict the radiation heat transfer rate from the reflector to the receiver. Based on the heat loss analysis, the performance of two different receivers for multifaceted parabolic solar collectors with several flat facets can be estimated, and the optimal facet size is obtained.

  • PDF