• Title/Summary/Keyword: Losses

검색결과 5,298건 처리시간 0.03초

소프트 스위칭 방식을 적용한 고효율 인터리브드 벅 컨버터 (A New High Efficiency Interleaved Buck Converter with Soft-switching Scheme)

  • 김낙윤;최현칠
    • 전력전자학회논문지
    • /
    • 제19권2호
    • /
    • pp.116-123
    • /
    • 2014
  • In this paper, a soft-switching scheme for the PWM interleaved buck converter(IBC) is newly proposed to obtain the advantages of both the conventional PWM interleaved buck and resonant converters such as ease of control, reduced switching losses and stresses, and low EMI. To obtain the soft-switching action, the proposed scheme employs an auxiliary circuit, which is added to the conventional interleaved buck converter and used to achieve soft-switching for both the main switches and the output diodes while not incurring any additional losses due to the auxiliary circuit itself. In this paper, the basic operations are discussed and design guidelines are presented. And through the experimental results, the usefulness of the proposed converter is verified.

Efficiency Analysis of a Ladder Multilevel Converter with the Use of the Equivalent Continuous Model

  • Lopez, Andres;Patino, Diego;Diez, Rafael
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1130-1138
    • /
    • 2014
  • This study analyzes a ladder multilevel converter (double ladder topology) with the use of a new averaging modeling technique. This technique introduces an analytical method to compute for the switching losses and is used to conduct an in-depth analysis of the influence of the switching frequency and parasitic resistance of components on converter efficiency. The obtained results enable the selection of switches and switching frequency to minimize losses. Moreover, simulation results and experimental measurements validate the analytical calculations.

상유전 $ZrTiO_4$박막의 유전특성 분석에 관한 연구 (Dielectric Properties Analysis in Paraelectric $ZrTiO_4$Thin Films)

  • 허진희;김경해;이준신
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.547-549
    • /
    • 2001
  • The dielectric constants and dielectric losses of ZrTiO$_4$thin films deposited by DC magnetron reactive sputtering were investigated. The paraelectric properties were measured in the 100kHz range. As the deposition temperature increased (up to 67$0^{\circ}C$), the dielectric losses (tan$\delta$) decreased (down to 0.017$\pm$0.007), while the dielectric constants ($\varepsilon$) were in the range of 35$\pm$7. Post annealing at 80$0^{\circ}C$ in oxygen for 2h reduced tan$\delta$ down to 0.005$\pm$0.001, higher than those of well-sintered bulk ZrTiO$_4$.

  • PDF

Cu-Al 전도체 형상에 따른 홀손실과 수직 홀전류 해석 (Analysis on the Hall Losses and Transverse Hall Current with Cu-Al Conductor Configuration)

  • 김상걸;정동회;정일형;이호식;정택균;김태완;이준웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.1076-1079
    • /
    • 2001
  • An anolmalous magnetoresistance effect has been theoretically studied at very low temperatures for composite normal metal conductors. This anomalous behavior is due to transverse Hall currents in the composite which would result in increased losses and higher effective resistance for the composite conductor. In this paper, transverse current flow and effective resistance with Cu-Al conductor configuration were analyzed using FEM(finite element method) for predicting the Hall losses to be resulted in anomalous magnetoresistance effect. And they are plotted three dimensionally to be visualized.

  • PDF

헬륨의 비이상기체 거동에 따른 VM열펌프의 손실 (Thermal Losses Due to Non-ideal Gas Behavior of Helium in VM Heat Pumps)

  • 백종훈;장호명
    • 설비공학논문집
    • /
    • 제8권2호
    • /
    • pp.279-287
    • /
    • 1996
  • A cycle analysis is performed to investigate how the non-ideal gas behavior of helium reduces the heating capacity of VM heat pumps. Since the operating pressures of VM heat pumps are as high as 1 to 20 MPa, the compressibility factor of helium becomes clearly greater than 1 and the non-ideal behavior always represents a thermal loss in heating. To calculate the amount of the losses, an adiabatic cycle analysis is performed with the real properties of helium and the net enthaply flows through the two regenerators are numerically obtained. It is shown that the non-ideal gas losses could be as much as 8% in the heating capacity when the operating pressures are greater than 10MPa. The effects of the operating temperatures and the dead volumes on the loss are presented.

  • PDF

VM열펌프의 2차해석 (A Second-Order Analysis of VM Heat Pumps)

  • 최연석;정은수
    • 설비공학논문집
    • /
    • 제8권2호
    • /
    • pp.208-218
    • /
    • 1996
  • Performance of a VM heat pump is considerably affected by various losses, such as enthalpy dump, reheat loss, pumping loss, conduction loss and shuttle loss. A second-order analysis model of VM heat pumps, which allows consideration of the major losses, was presented. Actual heat transfer rates for heat exchangers were calculated from the heat transfer rates obtained by the adiabatic analysis and various losses. New effective temperatures of heat exchangers were calculated from the actual heat transfer rates and the mean heat transfer coefficients until there was no appreciable change in the effective temperatures. Effects of design parameters, such as phase angle, swept volume ratio, regenerator length and speed on heating capacity, cooling capacity and COP were shown.

  • PDF

초전도 변압기 교류 손실 해석 (Analysis of AC Losses in HIS Transformer with Double Pancake Windings)

  • 김종태;김우석;김성훈;최경달;주형길;홍계원;한진호;이희균
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권1호
    • /
    • pp.17-21
    • /
    • 2005
  • AC loss is one of the important parameters in HTS (High Temperature Superconducting) AC devices. Among the HTS AC power devices, the transformer is the essential part in the electrical power system. But unfortunately, the transformer is the worst HTS device concerning AC loss because of very large magnetization loss due to high magnetic field applied to the HTS wire. We calculated the magnetization losses in HTS pancake windings for transformer according to the operating temperature. Two kinds of arrangement of HTS pancake windings were adopted for calculation of AC losses of a shell type transformer, and the analysis results were presented and discussed.

단일 보조 스위치를 이용한 ZC-ZVS PWM DC-DC 컨버터 (ZC-ZVS PWM DC-DC Converter using One Auxiliary Switch)

  • 박진민;박영조;서기영;문상필;김영문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.158-161
    • /
    • 2003
  • A new soft switching technique that improves performance of the high power factor boost rectifier by reducing switching losses is introduced. The losses are reduced by air active snubber which consists of an inductor, a capacitor a rectifier, and an auxiliary switch. Since the boost switch turns off with zero current, this technique is well suited for implementations with insulated gate bipolar transistors. The reverse recovery related losses of the rectifier are also reduced by the snubber inductor which is connected in series with the boost switch and the boost rectifier. In addition, the auxiliary switch operates with zero voltage switching. A complete design procedure and extensive performance evaluation of the proposed active snubber using a 1.2[kW] high power factor boost rectifier operating from a $90[V_{rms}]$ input are also presented.

  • PDF

Loss Characteristics of Flexible Dielectric Tube Waveguides using Commercial Polymer Substances in Millimeter Wave Band

  • Kim, Ki-Young;Youngsik Ahn;Sohn, Jon-Ryul;Tae, Heung-Sik
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2000년도 종합학술발표회 논문집 Vol.10 No.1
    • /
    • pp.233-237
    • /
    • 2000
  • Propagation losses including bath transmission losses and bending losses of the flexible dielectric tube waveguide using commercial polymer substances for a short distance millimeter wave transmission are analytically predicted. The transmission loss and the bending loss are strongly dependent on the power flow distributions in each region. The obtained propagation tosses are compared with those of the commercial metal rigid and flexible waveguides.

  • PDF

Analysis and Optimization of Air-Core Permanent Magnet Linear Synchronous Motors with Overlapping Concentrated Windings for Ultra-precision Applications

  • Li, Liyi;Tang, Yongbin;Ma, Mingna;Pan, Donghua
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권1호
    • /
    • pp.16-22
    • /
    • 2013
  • This paper presents the analysis and optimization of air-core permanent magnet linear synchronous motor with overlapping concentrated windings to achieve high thrust density, high thrust per copper losses and low thrust ripple. For the motor design, we adopt equivalent magnetizing current (EMC) method to analyze the magnetic field and give analytical formulae for calculation of motor parameters such as no-load back EMF, dynamic force, thrust density and thrust per copper losses. Further, we proposed a multi-objective optimization by genetic algorithm to search for the optimum parameters. The design optimization is verified by 2-D Finite Element analysis (FEA).