• Title/Summary/Keyword: Losses

Search Result 5,298, Processing Time 0.03 seconds

Design Parameter Deduction for Slotless Permanent Magnet Synchronous Motor/Generator (슬롯리스 영구자석 동기 전동/발전기를 위한 설계변수 도출)

  • Jang, Seok-Myeong;Lee, Un-Ho;You, Dae-Joon;Ko, Kyoung-Jin;Lee, Jung-Pill
    • Proceedings of the KIEE Conference
    • /
    • 2008.10c
    • /
    • pp.53-55
    • /
    • 2008
  • In high speed applications, the slotless permanent magnet(PM) motors appear an attractive solution, being almost insensitive to magneto-motive force harmonics and to pulse width modulation(PWM) current ripple and exhibiting lower stator iron losses and rotor losses (significant with square wave current control). So, this paper deals with methods for design of permanent magnet synchronous motor/generator.

  • PDF

Loss Modeling in order to Predict the Efficiency Performance of Induction Motor Drive System (유도전동기 드라이브 시스템의 효율성능을 예측하기 위한 손실 모델링)

  • 정동화;박기태;이정철
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.4
    • /
    • pp.56-61
    • /
    • 2000
  • The precise and reliable loss model for induction motor and converter system is very important in order to predict the efficiency performance of variable speed drives. This paper proposes an accurate loss model of induction motor and converter system. The motor losses, such as stator and rotor copper loss, core loss and stray loss, are considered for fundamental and harmonic frequencies. Also considered are the skin effect on rotor resistance, temperature effect on bath stator and rotor resistance, magnetizing inductance saturation, and friction and windage loss. All the above features are incorporated in a synchronous frame dynamic d-q equivalent circuit. The converter system, consisting of a diode rectifier and PWM transistor inverter, is modeled accurately for conduction and switching losses. Validity of the models, in both steady state and transient conditions, is verified by simulations.

  • PDF

Fatigue Test and Service Life Assessment of Steel Truss Bridges with Initial Imperfections (초기결함을 갖는 강교량의 피로시험 및 수명 평가)

  • 방명석
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.4
    • /
    • pp.119-122
    • /
    • 2000
  • The truss bridge is composed of numerous steel beams. In long span bridges the size of beams is getting larger, so the number of plate girders is increasing instead of rolled beams. This plate girder has long welding lines at the intersection of steel plates. The improper welding at the intersection line causes the steel bridge to be structurally unsafe. In this paper the loss of member section from improper welding was measured and the experimental testing was performed to get the S-N curve from testing models with sectional losses. The improper welding resulted in the lowering of structural safety and the shortening of life cycle.

  • PDF

A Novel PFC AC/DC Converter for Reducing Conduction Losses (도통손실 저감을 위한 새로운 역률 보상 AC/DC 컨버터)

  • 강필순;김광태;홍순일;김철우
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.273-278
    • /
    • 1999
  • This paper presents a novel Power Factor Corrected(PFC) single-stage AC/DC Half-Bridge converter, which features discontinuous conduction mode(DCM) and soft-switching. The reduced conduction losses are achieved by the employment of a novel power factor correction circuitry, instead of the conventional configuration composed of a front-end rectifier followed by a boost converter. To identify the validity of the proposed converter, simulated results of 500[W] converter with 100[V] input voltage and 50[V] output voltage are presented.

  • PDF

Properties of Electric Sofety for Dielectric Loss of Aging Natural Rubber. (노화된 천연고무의 유전손실에 관한 전기안전특성)

  • 이성일;권호영
    • Journal of the Korean Society of Safety
    • /
    • v.6 no.4
    • /
    • pp.5-12
    • /
    • 1991
  • The dielectric properties of natural rubbers for electric safety are very important to investigate the molecular structure. The electric safety characteristics of the dielectric absorption in aging vulcanized natural rubber were studied in the range of frequency from 1$\times$10$^3$[Hz]to 3.2$\times$10$^3$[Hz]l at the temperature of 23[$^{\circ}C$]. As the results, it has been confirmed that in the case of aging natural rubber of above 2 phr the specimens exhibit two kinds of dielectric losses due to the dipole polarization by impurities and sulfurs, and of raw rubber exhibit the kind of losses due to the dipole polarization. Rurthermore, dielectric loss maximum tansspectrum in high freguency region for electric safety, which removed to the low freguency according to increasing sulfur, depends greatly on sulfur.

  • PDF

Micro Propulsion under High Altitude Space Environments (우주진공환경에서의 마이크로 추진)

  • Jung, Sung-Chul;Huh, Hwan-Il
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.405-408
    • /
    • 2008
  • From the previous researches about flow characteristic of micro-nozzle, we found that viscosity and back pressure induced heavy losses in micro nozzle. To overcome thess losses, we began to study new conceptual micro propulsion system that is thermal transpiration based micro propulsion system. It has no moving parts and can pump the gaseous propellant by temperature gradient only (cold to hot). Most of previous research on thermal transpiration is in its early stage and mainly studied for application to small vacuum facility or gas chromatography in ambient condition using nanoporous material like aerogel. In this study, we focus on basic research of propulsion system based on thermal transpiration using polyimide material in vacuum conditions.

  • PDF

The Effects of Loss Aversion and Construal Level on the Attitude toward Financial Products (투자자의 손실회피 성향과 해석수준이 금융상품 태도에 미치는 영향)

  • Kang, Hyunmo
    • Knowledge Management Research
    • /
    • v.18 no.1
    • /
    • pp.49-65
    • /
    • 2017
  • Financial products entail either gains or losses, and customers' psychological reaction to these gains and losses affect the selection of the financial products. This study explains the financial customers' behavior by introducing consumers' psychological variables such as loss aversion and construal levels. According to the construal level theory, people use more abstract and higher levels of construal to represent objects that are more distant on psychological distance. Based on extant research about loss aversion and construal levels, this study proposes two hypotheses and test the hypotheses. The experimental study examines how loss aversion affects the choice between deposit products and fund products in short-term and long-term investment situations. In the long-term condition the respondents prefer fund products to deposit products, whereas in the short-term condition the respondents have showed the opposite result. Also, the effects of loss aversion on preferences for financial products have interacted with the time horizon of investments. Implications and limitations are discussed to establish more effective marketing strategies based on the results of this study.

Stabilities of Artificially Transconjugated Plasmids for the Bioremediation of Cocontaminated Sites

  • Yoon Kyung Pyo
    • Journal of Microbiology
    • /
    • v.43 no.2
    • /
    • pp.196-203
    • /
    • 2005
  • Here, we attempted to evaluate the activity of artificially transconjugated multiple plasmids in 'designer biocatalysts' for the bioremediation of cocontaminated sites under nonselective conditions. We observed profound losses in the percent survivals of artificially transconjugated plasmid activity ($66 - 78\%$ loss immediately after freeze-drying, $99.45 - 99.88\%$ loss by the end of 6 months storage) in reconstituted Pseudomonas sp. KM12TC. Such unpredictable high losses of this particular plasmid appeared to clearly be a deleterious effect. However, even after 6 months of storage, the cells remained able to degrade $95\%$ of phenol within 9 days, and the full effiux of$^%${73} As, as compared to that of the non-freeze-dried cells, was successfully achieved 4 to 9 days later. These results indicate that 'stable designer biocatalysts' can remain viable, even after freeze-drying and 6 months of storage.

SOFT SWITCHING AND LOSS ANALYSIS OF A HALF-BRIDGE DC-DC CONVERTER WITH IGBT-MOSFET PARALLEL SWITCHES

  • Hong, Soon-Chan;Seo, Young-Min;Jang, Dong-Ryul;Yoon, Duck-Yong;Hwang, Yong-Ha
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.713-718
    • /
    • 1998
  • Due to high power ratings and low conduction loss, the IGBT has become more attractive in high power applications. However, its slower characteristics than those of MOSFET cause severe switching losses and switching frequency limitation. This paper proposes the IGBT's soft switching concept with the help of MOSFET, where each of the IGBT and MOSFET plays its role during on-periods and switching instants. Also, the switching losses are analyzed by using the linearized modeling and the modeling and the operations of a converter are investigated to confirm the soft switching of IGBT's.

  • PDF

New Mathematical Models with Core Loss Factor for Control of AC Motors

  • Shinnaka, Shinji
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.630-635
    • /
    • 1998
  • This paper establishes in a new unified manner new mathematical models with core(iron) loss factor for two kinds of AC motors, induction and synchronous motors which are supposed to generate torque precisely or/and efficiently under vector controls. Our new models consist of three basic equations consistent with the others such as differential equation describing electromagnetic dynamics, torque equation describing torque generating mechanism, energy transmission equation describing how injected energy is wasted, saved or transmitted where all vector signals are defined in general frame of arbitrary instant angular velocity. It is clearly shown in our models that equivalent core-loss resistance can express appropriately and separately both eddy-current and hysteresis losses rather than mere vague loss. Proposed model of induction motor is the most compact in sense of the number of employed interior states and parameters. This compact model can also represent eddy-current and hysteresis losses of rotor as well as stator. For synchronous motor, saliency is taken into consideration. As well known model for cylindrical motor can be obtained directly from salient one as its special case.

  • PDF