비상노심냉각계통 주입에 따른 저온관 및 강수관에서 단상 열성층 수치해석 : 부력항 고려 필요성에 관한 연구 (Numerical Analysis of Single Phase Thermal Stratification in both Cold Legs and Downcomer by Emergency Core Cooling System Injection : A Study on the Necessity to Consider Buoyancy Force Term)

  • 이공희;정애주
    • 설비공학논문집
    • /
    • 제29권12호
    • /
    • pp.654-662
    • /
    • 2017
  • When emergency core cooling system (ECCS) is operated during loss of coolant accident (LOCA) in a pressurized water reactor (PWR), pressurized thermal shock (PTS) phenomenon can occur as cooling water is injected into a cold leg, mixed with hot primary coolant, and then entrained into a reactor vessel. Insufficient flow mixing may cause temperature stratification and steam condensation. In addition, flow vibration may cause thermal stresses in surrounding structures. This will reduce the life of the reactor vessel. Due to the importance of PTS phenomenon, in this study, calculation was performed for Test 1 among six types of OECD/NEA ROSA tests with ANSYS CFX R.17. Predicted results were then compared to measured data. Additionally, because temperature difference between the hot coolant at the inlet of the cold leg and the cold cooling water at the inlet of the ECCS injection line is 200 K or more, buoyancy force due to density difference might have significant effect on thermal-hydraulic characteristics of flow. Therefore, in this study, the necessity to include buoyancy force term in governing equations for accurate prediction of single phase thermal stratification in both cold legs and downcomer by ECCS injection was numerically studied.

직접용기주입에 따른 유체혼합에 관한 연구 (An Investigation of Fluid Mixing with Direct Vessel Injection)

  • Cha, Jong-Hee;Jun, Hyung-Gil
    • Nuclear Engineering and Technology
    • /
    • 제26권1호
    • /
    • pp.63-77
    • /
    • 1994
  • 이 연구는 가압경수로의 원자로 다운커머내에서 과도냉각시 직접용기주입에 따른 유체혼합현상을 가압열충격의 견지에서 시험모델을 사용하여 조사한 것이다. 시험모델은 ABB-CE System80+ 원자로 구조에 근거하여 설계되었다. 이 원자로에 대한 가능성 있는 가압열충격 사고로서 콜드레그 소형파단 냉각재 상실사고와 주중기관 판단 사고가 선정되었다. 시험은 두 부분으로 구성되는데 첫째 부분은 원자로 다운커머에서 직접용기 주입수와 기존냉각재간의 유체혼합을 가시화법에 의하여 시험한 것이고, 둘째 부분은 별도의 시험모델에서 직접용기주입에 따른 열적혼합을 시험한 것이다. 가시화 시험에서는 과도적 냉각기간중 직접용기 주입수와 1차 냉각재간의 물리적 상호작용이 밝혀졌다. 열적혼합시험에서는 소형파단 냉각재 상실사고시 직접용기주입에 의한 심한 냉각현상이 다운커머내서 관찰되었다. 측정된 온도곡선은 소형파단 냉각재 상실사고에 대하여 REMIX 로드, 증기관 파단사고에 대하여는 COM-MIX-1B 코드에 의한 계산과 비교되었다.

  • PDF

중수로 원전 교류전원 완전상실 사고 시 일차측 열수송 펌프 밀봉 누설 영향에 대한 코드 분석 (Code Analysis of Effect of PHTS Pump Sealing Leakage during Station Blackout at PHWR Plants)

  • 유선오;조민기;이경원;백경록
    • 한국압력기기공학회 논문집
    • /
    • 제16권1호
    • /
    • pp.11-21
    • /
    • 2020
  • This study aims to develop and advance the evaluation technology for assessing PHWR safety. For this purpose, the complete loss of AC power or station blackout (SBO) was selected as a target accident scenario and the analysis model to evaluate the plant responses was envisioned into the MARS-KS input model. The model includes the main features of the primary heat transport system with a simplified model for the horizontal fuel channels, the secondary heat transport system including the shell side of steam generators, feedwater and main steam line, and moderator system. A steady state condition was achieved successfully by running the present model to check out the stable convergence of the key parameters. Subsequently, through the SBO transient analyses two cases with and without the coolant leakage via the PHTS pumps were simulated and the behaviors of the major parameters were compared. The sensitivity analysis on the amount of the coolant leakage by varying its flow area was also performed to investigate the effect on the system responses. It is expected that the results of the present study will contribute to upgrading the evaluation technology of the detailed thermal hydraulic analysis on the SBO transient of the operating PHWRs.

INVESTIGATION ON EFFECTS OF ENLARGED PIPE RUPTURE SIZE AND AIR PENETRATION TIMING IN REAL-SCALE EXPERIMENT OF SIPHON BREAKER

  • Kang, Soon Ho;Lee, Kwon-Yeong;Lee, Gi Cheol;Kim, Seong Hoon;Chi, Dae Young;Seo, Kyoungwoo;Yoon, Juhyeon;Kim, Moo Hwan;Park, Hyun Sun
    • Nuclear Engineering and Technology
    • /
    • 제46권6호
    • /
    • pp.817-824
    • /
    • 2014
  • To ensure the safety of research reactors, the water level must be maintained above the required height. When a pipe ruptures, the siphon phenomenon causes continuous loss of coolant until the hydraulic head is removed. To protect the reactor core from this kind of accident, a siphon breaker has been suggested as a passive safety device. This study mainly focused on two variables: the size of the pipe rupture and the timing of air entrainment. In this study, the size of the pipe rupture was increased to the guillotine break case. There was a region in which a larger pipe rupture did not need a larger siphon breaker, and the water flow rate was related to the size of the pipe rupture and affected the residual water quantity. The timing of air entrainment was predicted to influence residual water level. However, the residual water level was not affected by the timing of air entrainment. The experimental cases, which showed the characteristic of partical sweep-out mode in the separation of siphon breaking phenomenon [2], showed almost same trend of physical properties.

Parameter importance ranking for SBLOCA of CPR1000 with moment-independent sensitivity analysis

  • Xiong, Qingwen;Gou, Junli;Shan, Jianqiang
    • Nuclear Engineering and Technology
    • /
    • 제52권12호
    • /
    • pp.2821-2835
    • /
    • 2020
  • The phenomenon identification and ranking table (PIRT) is an important basis in the nuclear power plant (NPP) thermal-hydraulic analysis. This study focuses on the importance ranking of the input parameters when lacking the PIRT, and the target scenario is the small break loss of coolant accident (SBLOCA) in a pressurized water reactor (PWR) CPR1000. A total of 54 input parameters which might have influence on the figure of merit (FOM) were identified, and the sensitivity measure of each input on the FOM was calculated through an optimized moment-independent global sensitivity analysis method. The importance ranking orders of the parameters were transformed into the Savage scores, and the parameters were categorized based on the Savage scores. A parameter importance ranking table for the SBLOCA scenario of the CPR1000 reactor was obtained, and the influences of some important parameters at different break sizes and different accident stages were analyzed.

KEY IMPACT PARAMETERS FOR APPLICATION OF ALTERNATIVE SOURCE TERM TO KORI UNIT 1

  • Lee, Seung-Chan
    • Nuclear Engineering and Technology
    • /
    • 제42권4호
    • /
    • pp.394-413
    • /
    • 2010
  • The object of this paper is to identify the key elements that impact a radiation dose at EAB (Exclusion Area Boundary). This study is based on the AST (Alternative Source Terms) as defined in Regulatory Guide 1.183. The LOCA (Loss of Coolant Accident) and the LRA (Locked Rotor Accident) are selected as limiting cases. A sensitivity analysis of accidental behavior with respect to various parameters during LOCA and LRA at Kori Unit 1 is also undertaken for the following objectives: to determine the limiting parameters, to find the impact trend of the radiation dose, and to find the safety margin between AST and TID (Technical Information Document) methodologies. This work confirms that key parameters are particulate removal rate, decontamination factor, iodine chemical form, gap fraction, partitioning factor, and the impact of isotopes group. Comparing TID with AST, the radiation dose of TID is about 80% greater than that of AST under a LOCA, and about 60% greater than that of AST for the case of a LRA; thus the safety margin is remarkably increased when the AST is used. In this work, the sensitivity analysis results are presented in terms of a sensitivity index called the "NDD (Normalized Dose Difference)", which compares the impact of parameters with that of a reference case. These values are derived by using a combination of the leak rate (primary to secondary), iodine chemical form, gap fraction, partitioning factor, spray removal rate, source term, and other variables.

An Improvement of Estimation Method of Source Term to the Environment for Interfacing System LOCA for Typical PWR Using MELCOR code

  • Han, Seok-Jung;Kim, Tae-Woon;Ahn, Kwang-Il
    • Journal of Radiation Protection and Research
    • /
    • 제42권2호
    • /
    • pp.106-113
    • /
    • 2017
  • Background: Interfacing-system loss-of-coolant-accident (ISLOCA) has been identified as the most hazardous accident scenario in the typical PWR plants. The present study as an effort to improve the knowledge of the source term to the environment during ISLOCA focuses on an improvement of the estimation method. Materials and Methods: The improvement was performed to take into account an effect of broken pipeline and auxiliary building structures relevant to ISLOCA. An estimation of the source term to the environment was for the OPR-1000 plants by MELOCR code version 1.8.6. Results and Discussion: The key features of the source term showed that the massive amount of fission products departed from the beginning of core degradation to the vessel breach. Conclusion: The release amount of fission products may be affected by the broken pipeline and the auxiliary building structure associated with release pathway.

CANDU형 원자로 격납건물의 극한내압능력 평가에 관한 연구 (A Study on Evaluation of Ultimate Internal Pressure Capacity of CANDU-type Nuclear Containment Buildings)

  • 김선훈
    • 한국전산구조공학회논문집
    • /
    • 제24권3호
    • /
    • pp.343-351
    • /
    • 2011
  • 원자로 격납건물은 원자력발전소에서 발생가능한 모든 비상사태에 대한 최후의 방벽 역할을 하고 있다. 따라서 사고발생시 원자로 격납건물의 극한능력을 판단하는 것은 매우 중요하다. 대표적인 고려사항 가운데 하나인 LOCA사고 발생시 CANDU형 원자로 격납건물의 극한능력을 파악하기 위해서는 구조적 안전성 평가를 위한 구조해석이 필요하다. CANDU형 원자로 격납건물은 돔과 원통형벽체로 구성된 프리스트레스 콘크리트 쉘 구조물로서 부착식 텐돈을 사용하고 있다. 본 논문에서는 극한내압능력의 평가를 위하여 3차원 구조해석시스템을 사용한 프리스트레스 콘크리트 격납건물의 비선형해석을 수행하였다.

Experiments and MAAP4 Assessment for Core Mixture Level Depletion After Safety Injection Failure During Long-Term Cooling of a Cold Leg LB-LOCA

  • Kim, Y. S.;B. U. Bae;Park, G. C.;K. Y. Sub;Lee, U. C .
    • Nuclear Engineering and Technology
    • /
    • 제35권2호
    • /
    • pp.91-107
    • /
    • 2003
  • Since DBA(Design Basis Accidents) has been studied rather separately from SA(Severe Accidents) in the conventional nuclear reactor safety analysis, the thermal hydraulics during transition between DBA and SA has not been identified so much as each accident itself. Thus, in this study, the thermal hydraulic behavior from DBA to the commencement of SA has been experimentally and analytically investigated for the long-term cooling phase of LB-LOCA(Large-Break Loss-of-Coolant Accident). Experiments were conducted for both cases of the loop seal open and closed in an integral test loop, named as SNUF (Seoul National University Facility), which was scaled down to l/6.4 in length and 1/178 in area of the APR1400 (Advanced Power Reactor 1400MWe). The core mixture level was a main measured value since it took major role in the fuel heat-up rate, the location of fuel melting initiation and the channel blockage by melting material during SA. Experimental results were compared to MAAP4.03 to assess its model of calculating the core mixture level. MAAP4.03 overestimates the core two- phase mixture level because sweep-out and spill-over and the measures to simulate the status of loop seal are not included, which is against the conservatism. Thus, it is recommended that MAAP4.03 should be improved to simulate the thermal hydraulic phenomena, such as sweep-out, spill-over and the status of loop seal.

RCD success criteria estimation based on allowable coping time

  • Ham, Jaehyun;Cho, Jaehyun;Kim, Jaewhan;Kang, Hyun Gook
    • Nuclear Engineering and Technology
    • /
    • 제51권2호
    • /
    • pp.402-409
    • /
    • 2019
  • When a loss of coolant accident (LOCA) occurs in a nuclear power plant, accident scenarios which can prevent core damage are defined based on break size. Current probabilistic safety assessment evaluates that core damage can be prevented under small-break LOCA (SBLOCA) and steam generator tube rupture (SGTR) with rapid cool down (RCD) strategy when all safety injection systems are unavailable. However, previous research has pointed out a limitation of RCD in terms of initiation time. Therefore, RCD success criteria estimation based on allowable coping time under a SBLOCA or SGTR when all safety injection systems are unavailable was performed based on time-line and thermal-hydraulic analyses. The time line analysis assumed a single emergency operating procedure flow, and the thermal hydraulic analysis utilized MARS-KS code with variables of break size, cooling rate, and operator allowable time. Results show while RCD is possible under SGTR, it is impossible under SBLOCA at the APR1400's current cooling rate limitation of 55 K/hr. A success criteria map for RCD under SBLOCA is suggested without cooling rate limitation.