• Title/Summary/Keyword: Loss of contact

Search Result 601, Processing Time 0.027 seconds

An Optical Microswitch Integrated with Silicon Waveguides, Micromirrors, and Electrostatic Touch-Down Beam Actuators (실리콘 광도파로, 미소거물 및 접촉식 정 전구동기가 집적된 광스위치)

  • Jin, Yeong-Hyeon;Seo, Gyeong-Seon;Jo, Yeong-Ho;Lee, Sang-Sin;Song, Gi-Chang;Bu, Jong-Uk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.12
    • /
    • pp.639-647
    • /
    • 2001
  • We present an integrated optical microswitch, composed of silicon waveguides, gold-coaled silicon micromirrors, and electrostatic contact actuators, for applications to the optical signal transceivers. For a low switching voltage, we modify the conventional curled electrode microactuator into a electrostatic microactuator with touch-down beams. We fabricate the silicon waveguides and the electrostatically actuated micromirrors using the ICP etching process of SOI wafers. We observe the single mode wave propagation through the silicon waveguide with the measured micromirror loss of $4.18\pm0.25dB$. We analyze major source of the micromirror loss, thereby presenting guidelines for low-loss micromirror designs. From the fabricated microswitch, we measure the switching voltage of 31.74V at the resonant frequency of 6.89kHz. Compared to the conventional microactuator, the present contact microactuator achieves 77.4% reduction of the switching voltage. We also discuss a feasible method to reduce the switching voltage to 10V level by using the electrode insulation layers having the residual stress less than 30MPa.

  • PDF

A Design of MMIC Mixer for I/Q Demodulator of Non-contact Near Field Microwave Probing System (비접촉 마이크로웨이브 프루브 시스템의 I/Q Demodulator를 위한 MMIC Mixer의 설계)

  • Ryu, Keun-Kwan;Kim, Sung-Chan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.5
    • /
    • pp.1023-1028
    • /
    • 2012
  • A MMIC (Monolithic Microwave Integrated Circuit) mixer chip using the Schottky diode of an GaAs p-HEMT process has been developed for the I/Q demodulator of non-contact near field microwave probing system. A single balanced mixer type is adopted to achieve simple structure of the I/Q demodulator. A quadrature hybrid coupler and a quarter wavelength transmission line for 180 degree hybrid are realized with lumped elements of MIM capacitor and spiral inductor to reduce the mixer chip size. According to the on-wafer measurement, this MMIC mixer covers RF and LO frequencies of 1650MHz to 2050MHz with flat conversion loss. The MMIC mixer with miniature size of $2.5mm{\times}1.7mm$ demonstrates conversion loss below 12dB for both variations of RF and LO frequencies, LO-to-IF isolation above 43dB and RF-to-IF isolation above 23dB, respectively.

A study on the correlation between the degree of elasticity uniformity and the dynamic performance in the overhead contact lines (전차선로 탄성도 불균일율과 동역학적 성능과의 관계에 대한 연구)

  • Park, Sa-Hoon;Kwon, Sam-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.502-502
    • /
    • 2007
  • A catenary system should be designed to have an uniform elasticity over a span in order to maintain the lowest possible loss of contact between a pantograph and a contact wire. A elasticity uniformity of a catenary can be regarded as a important design factor used for predicting the current collection performance for a catenary. There are a couple of formulas to calculate the degree of elasticity uniformity of a catenary according to the literature survey. The effectiveness of these formulas is reviewed by performing catenary elasticity and loss of contact analysis for various different configurations of catenary systems using a beam element based FEM program. The results reveals that these formulas are not suitable to predict the current collection performance for a catenary. Therefore, a new formula based on the standard deviation of the elasticity over a span is proposed in this study. The analysis results show that the new formula for an elasticity uniformity of a catenary is very effective in predicting the current collection performance for a catenary.

  • PDF

Effect of open proximal contact on adjacent tooth and implant (개방된 인접면 접촉이 인접자연치와 임플란트에 미치는 영향)

  • Moon, Sohyun;Kim, Gwangyun;Cho, Seonghun;Song, Joohun;Kim, Hee-Jung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.1
    • /
    • pp.9-17
    • /
    • 2022
  • Purpose: The purpose of this study is to investigate how open contacts impact the natural teeth and dental implant prostheses. Materials and Methods: Following criteria were used to select 20 implant crowns with open proximal contacts as the experimental group (Group A): the restorations were delivered in Chosun University Dental Hospital between 2008 and 2018, the restorations are in the posterior region, opposing teeth are fixed dental prostheses, neighboring teeth are sound natural teeth, the patient had been on the maintenance program for at least 3 years. Another 20 implant crowns with closed proximal contacts were selected as the control group (Group B) using the same criteria. Between the two groups, dental caries and food impaction of the neighboring natural teeth and marginal bone-loss of the implants were compared and evaluated. Results: There was no statistically significant difference between Group A and Group B in the occurrence rates of dental caries, food impaction, and marginal bone-loss. The amount of marginal bone-loss, however, revealed statistically significant differences between the two groups, with Group A showing 0.80 ± 0.39 mm loss and Group B showing 1.1 ± 0.43 mm loss. Conclusion: Implant prostheses with open contacts could be clinically considered in select cases as such restorations revealed no harmful effects on neighboring teeth and implant restorations within the perimeters of this study.

Study on Analysis of Transfer Torque and Improvement of Transfer Torque in Non-Contact Permanent Magnet Gear (비접촉 영구자석 기어의 전달토크 분석 및 전달토크 향상에 대한 연구)

  • Park, Gyu-Sang;Kim, Chan-Ho;Kim, Yong-Jae
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.181-188
    • /
    • 2015
  • The non-contact permanent magnet gear has advantages of high efficiency and improved reliability. It has other advantages of no mechanical friction loss, very little noise and vibration, and no need for lubricant. With these advantages, the non-contact permanent magnet gear that solves the physical contact problem of the mechanical gear has drawn attention. Due to this unique non-contact characteristic, the non-contact permanent magnet gear which is capable of non-contact torque transmission has replaced mechanical gear. The mechanical gears which is in many fields of the modern industry, is used mostly for power transmitting mechanical devices. However, it also has the problem of a low torque density, which requires improvement. In this paper, a novel pole piece shape is proposed in order to improve the problem of low torque density of the non-contact permanent magnet gear. The experiment data required for predicting the relationships among them are obtained using finiteelement Operating method based on two-dimensional (2-D) numerical analysis. Therefore, this paper derived an optimal model for thenon-contact permanent magnet gear with the novel pole piece using the Box-Behnken design, and the validity of the optimal design of the proposed pole piece shape through variance analysis and regression analysis demonstrated. In this paper, we performed the thransfer torque analysis in order to improve the torque density and power density, we have performed on optimal design of proposed pole piece shape using box-behnken.

A Study on CIETEC Arbitration Case for the Relationship between Damages and Reduction under CISG (CISG상 손해배상과 대금감액의 관계에 관한 중국 CIETAC의 중재사례 연구)

  • Song, Soo-Ryun
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.51
    • /
    • pp.133-158
    • /
    • 2011
  • The purpose of this study is to analyze one of CIETEC(China International Economic and Trade Arbitration Commission) Award on the dispute arising from Cotton Sale Contact which deals with damages and reduction of the price. Especially this case focused on the effect of reduction of the price to damages. The purpose of damages is to place the aggrieved party in as good a position as if the other party had properly performed the contract. So court costs and attorney's fee should be regarded as the loss, because these are caused by consequence of the breach which is recoverable. With the same reason, overpaid taxes should also regard as the loss. It is not impossible, however, to claim both damages and reduction of the price for same loss at the same time. It means buyer could not claim damages for the same loss, once he already claimed reduction of the price. So Korean companies should consider which remedy is proper to himself under the circumstances. He should choose reduction of the price when market price is down. In case of rising market price, he should consider follows: first, it is better to choose damages based on current price(Art.76), if upswing of non-conformity price is higher then upswing of market price. Second, it is better to choose general rule for measuring damages(Art.74), if upswing of market price is higher then upswing of non-conformity price.

  • PDF

An Experimental Study of the Performance Characteristics with Four Different Rotor Blade Shapes on a Small Mixed-Type Turbine

  • Cho Soo-Yong;Cho Tae-Hwan;Choi Sang-Kyu
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.7
    • /
    • pp.1478-1487
    • /
    • 2005
  • A small mixed-type turbine with a diameter of 19.9 mm has been substituted for a rotational part of pencil-type air tool. Usually, a vane-type rotor is applied to the rotational part of the air tool. However, the vane-type rotor has some problems, such as friction, abrasion, and necessity of accurate assembly etc.,. These problems make the life time of the vane-type air tool short, but air tools operated by mixed-type turbines are free of friction and abrasion because the turbine rotor dose not contact with the casing. Moreover, it is assembled easily because of no axis offset. These characteristics are merits for using air tools, but loss of power is inevitable on a non-contacting type rotor due to flow loss, tip clearance loss, and profile loss etc.,. In this study, four different rotors are tested, and their characteristics are investigated by measuring the specific output power. Additionally, optimum nozzle location against the rotor is studied. Output powers are obtained through measured pressure, temperature, torque, rotational speed, and flow rate. The experimental results obtained with four different rotors show that the rotor blade shape greatly influences to the performance, and the optimum nozzle location exists near the mid span of the rotor.

Heat Transfer Analysis and Cooling Design for Crude Oil Pump System (원유펌프시스템의 열전달해석 및 냉각설계)

  • Kim, Wan-Gi;Lee, Joon-Yeob;Kwon, Jung-Lock;Kim, Hea-Choen
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2017-2022
    • /
    • 2008
  • The crude oil pump system is the equipment for transporting crude oil and it consists of 3 major components, a motor and an impeller which discharge underground crude oil, a pipestack that transmits the cooling oil and power, and a cooling oil unit & junction box that provides cooling oil and electric power. When considering the system characteristics that it has to be installed at a depth of deeper than 100 m, a design technology for the efficient control of the heat occurring at a conductor and motor is necessary and it is the essential factor for ensuring system durability. In this paper, therefore, cooling oil flow has been calculated to satisfy the limit value of the system temperature by analyzing heat flow considering the related losses such as loss of conductor, contact resistor loss at the conductor connection, and operation loss of motor. And the operation temperature has been set up based on the temperature of crude oil and the heat of motor and conductor. Also, a design for cooling of crude oil pump system has been proposed by calculating the operation pressure loss and selecting the capacity of a cooling oil pump and a heat exchanger.

  • PDF

Clinical Evaluation of Occlusal Contact Changes in Implant Prosthesis (임플란트 보철의 교합 접촉 변화에 대한 임상적 평가)

  • Yun, Chul-Hee;Kim, Dae-Gon;Yi, Yang-Jin;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.1
    • /
    • pp.21-30
    • /
    • 2007
  • Despite of the successful clinical performance of implants, it is still lacking of the knowledge of changes in implant occlusion. The purpose of this study was to evaluate the changes of infraocclusal contact after clinical occlusal function of implant. Twenty patients(38 implants) were recalled during 10 months after placement of implant prosthesis. Occlusion changes were investigated at placement, placement 1 months, 4 months and 10 months serially with silicone bite material and T-Scan II sensor. Bony changes were also evaluated with periapical radiographs. The changes of silicone thickness and T-Scan II sensored areas were statistically analyzed with repeated measured ANOVA and the Scheffe's post-hoc test at the 95% significance level. The following results have been made based on this study: 1. Alveolar bone loss was within 0.20mm and it was generally concluded within physiologic level. 2. There were no statistically significant differences in the thickness changes of silicone material at 1 month and 4 months of occlusal function. However, there was statistically significant difference at 10 months of occlusal function (p<0.05). 3. There was no statistically significant difference in changes of occlusal contact area in T-Scan II at 1 month and 4 months of occlusal function, but there was statistically significant difference at 10 months of occlusal function (p<0.05). Conclusively, as time goes by, implant occlusion to be formed infraocclusion was to be far close and increased occlusal contact. However, it was not observed destructive bone resorption in periapical radiographs and any other side effects.

Studies on toxic substances of Gingko leaves inducing contact dermatitis in rabbit (은행엽(銀杏葉)의 가토(家兎) 피부(皮膚) 접촉성염증(接觸性炎症) 유발(誘發) 독성물질(毒成物質)에 관(關)한 연구(硏究))

  • Baek, Byeong-kirl;Kim, Byeong-su;Kim, Sun-hee;Ahn, Byung-zun
    • Korean Journal of Veterinary Research
    • /
    • v.31 no.3
    • /
    • pp.319-327
    • /
    • 1991
  • Gingko biloba is one of the oldest trees on earth. It can be traced 300 million years or more into past. In recent years, this tree has become increasingly popular because of its longevity. Amount of comsumption of Gingko leaves in Korea is increased to produce drugs for blood circulating system's disorder. The workers who work at the company of product drug with Gingko leaves complain pruritus at belt position of west, however toxic substance from extracts of Gingko biloba was carried out to determine what kind of the toxic substance from extract could induce a contact dermatitis by means of histopathological study. Dried leaves of Korean G. biloba were exhaustively extracted with chloroform. The aqueous chloroform residue was extracted with hexane. After evaporation, the hexane extract was passed through a silica gel column chromatography, it was separated into 9 fractions by means of gradient solvent (benzene: acetone/ 98~93 : 2~7%). The 4th and 7th fraction were idendified as bilibol and gingkolic acid by silica gel thin layer chromatography and NMR spectrophotometer. The 4th and 7th fractions of Korean Gingko leaves have an irritant substances which can be induced ear swelling and increased thickness of stratum cornium of rabbit ear exposed with the fractions (3 time/3 day, $100{\mu}l$ of 50mg/ml ethyl alcohol). In the 4th fraction, the substance have induced the surface of ear to swell and mass of unknown cell like inflammatory cell were infiltrated within the stratum corneum, and the 7th fraction have the surface of ear to loss the hairs, and sebaceous gland and follicle of hair were infiltrated with inflammatory cells. and other fractions at all did not induced a certain contact dermatitis and also Deutschen drug of Gingko (named as Gerigeron) have induced the contact dermatitis such as dematitis of Korean Gingko extract.

  • PDF