• Title/Summary/Keyword: Loss of Field

Search Result 2,332, Processing Time 0.038 seconds

Magnetization Loss Characteristics of a Bi-2223 Tape in Parallel Magnetic Fields (수평자장에 대한 Bi-2223테이프의 자화손실 특성)

  • Ryu, Kyung-Woo;Han, Hyung-Ju;Choi, Byung-Ju;Nah, Wan-Soo;Joo, Jin-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.4
    • /
    • pp.158-163
    • /
    • 2001
  • Magnetization losses of a Bi-2223 tape in magnetic fields parallel to the tape surface were measured by a room temperature cancellation and a cryogenic temperature cancellation. The results indicate that the same loss data are observed for both methods. The magnetization losses are hysteretic because the measured losses agree well with calculated ones based on a critical state model. In the full field penetration cases the magnetization losses increase with the frequency but in the partial field penetration cases the influence of the frequency is opposite.

  • PDF

Analysis of the local superconducting properties in YBCO coated conductors with striations

  • Kim, Muyong;Park, Sangkook;Park, Heeyeon;Ri, Hyeong-Cheol
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.2
    • /
    • pp.25-30
    • /
    • 2015
  • In order to realize economical applications, it is important to reduce the ac loss of 2G high-temperature superconductor coated conductors. It seems to be reasonable that a multi-filamentary wire can decrease the magnetization loss. In this study, we prepared two samples of YBCO coated conductors with striations. We measured local superconducting properties of both samples by using Low Temperature Scanning Laser and Hall Probe Microscopy (LTSLHPM). The distribution of the local critical temperature of samples was analyzed from experimental results of Low Temperature Scanning Laser Microscopy (LTSLM) near the superconducting transition temperature. According to LTSLM results, spatial distributions of the local critical temperature of both samples are homogeneous. The local current density and the local magnetization in samples were explored from measuring stray fields by using Scanning Hall Probe Microscopy (SHPM). From SHPM results, the remanent field pattern of the one bridge sample in an external magnetic field confirms the Bean's critical state model and the three bridge sample has similar remanent field pattern of the one bridge sample. The local magnetization curve in the three bridge sample was measured from external fields from -500 Oe to 500 Oe. We visualized that the distribution of local hysteresis loss are related in the distribution of the remanent field of the three bridge sample. Although the field dependence of the critical current density must be taken into account, the relation of the local hysteresis loss and the remanent field from Bean's model was useful.

A Study to Determine the Slope Length and Steepness Factor of Universal Soil Loss Equation with Determining and Adapting Major Slope Length at Field Scale (필지 단위 주경사장 산정 및 적용을 통한 범용토양유실공식 지형인자 산정 개선 연구)

  • Park, Youn Shik;Park, Jong-Yoon;Jang, Won Seok;Kim, Jonggun
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.6
    • /
    • pp.55-65
    • /
    • 2019
  • Universal Soil Loss Equation (USLE) is to estimate potential soil loss and has benefit in use with its simplicity. The equation is composed of five factors, one of the factors is the slope length and steepness factor (LS factor) that is for topographic property of fields to estimate potential soil loss. Since the USLE was developed, many equations to compute LS was suggested with field measurement. Nowadays the factor is often computed in GIS software with digital elevation model, however it was reported that the factor is very sensitive to the resolution of digital elevation model. In addition, the digital elevation model of high resolution less than 3 meter is required in small field application, however these inputs are not associate with the empirical models' backgrounds since the empirical models were derived in 22.1 meter field measurements. In the study, four equation to compute LS factor and two approaches to determine slope length and steepness were examined, and correction factor was suggested to provide reasonable precision in LS estimations. The correction factor is computed with field area and cell size of digital elevation model, thus the correction factor can be adapted in any USLE-based models using LS factor at field level.

A Reliable Low-Loss Field-Installable Optical Connector Design by Splicing Angle Adjustment (접속 각도 조정을 통한 신뢰성 있는 저 손실 현장조립 광커넥터 설계)

  • Park, Byung-Chul;Rim, Chong-Suck;Jung, Jun-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.9
    • /
    • pp.6-12
    • /
    • 2011
  • In this paper, we propose a design method for a reliable and improved field-installable optical connectors(FIOC) which are needed for long-distance and low loss FTTH configuration. To this end, we optimize the angle of splicing between the inner fiber and the field fiber of the FIOC, so that the low loss connection of optical fibers is possible without using any angle alignment tools as well as angled cleavers. More precisely, we set the cutting angle of the inner filber and the field fiber to be $2^{\circ}$ by using an angled cleaver and $0^{\circ}{\sim}1^{\circ}$ by using a general fiber cutter, respectively. Splicing these two optical fibers without any further adjustment, we can keep the insertion loss within 0.3dB and the reflection loss within -60dB.

Estimation of critical current density of a YBCO coated conductor from a measurement of magnetization loss (자화손실 측정값으로부터 추정한 YBCO CC의 임계전류밀도 평가)

  • Lee, S.;Park, S.H.;Kim, W.S.;Lee, J.K.;Choi, K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.3
    • /
    • pp.16-20
    • /
    • 2010
  • For large scale power applications of HTS conductor, it is getting more important to have a stacked HTS coated conductor with low loss and large current capacity. But it was not easy to measure some electric properties. Stabilizer free YBCO CC for striated/ stacked conductors is easily burned out during the measurement of the critical current density because it has no stabilizer and it is difficult to set-up the current lead and voltage taps because it has many pieces of YBCO CC in a conductor. Instead of direct measuring the critical current of a stacked HTS coated conductor, indirect estimation from measuring a magnetization loss of HTS coated conductor could be useful for practical estimation of the critical current. The magnetization loss of a superconductor is supposed to be affected by a full penetrating magnetic field, and it tends to show an inflection point at the full penetrating magnetic field when we generate the graph of magnetization loss vs. external magnetic field. The full penetrating magnetic field depends on the shape of the conductor and its critical current density, so we can estimate the effective critical current density from measuring the magnetization loss. In this paper, to prove the effectiveness of this indirect estimation of the critical current, we prepared several different kinds of YBCO CC(coated conductor) including a stacked conductor short samples and measured the magnetization losses and the critical currents of each sample by using linked pick up coils and direct voltage measurement with transport current respectively.

Iron Loss Analysis of a Permanent Magnet Rotating Machine Taking Account of the Vector Hysteretic Properties of Electrical Steel Sheet

  • Yoon, Heesung;Jang, Seok-Myeong;Koh, Chang Seop
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.2
    • /
    • pp.165-170
    • /
    • 2013
  • This paper presents the iron loss prediction of rotating electric machines taking account of the vector hysteretic properties of electrical steel sheet. The E&S vector hysteresis model is adopted to describe the vector hysteretic properties of a non-oriented electrical steel sheet, and incorporated into finite element analysis (FEA) for magnetic field analysis and iron loss prediction. A permanent magnet synchronous generator is taken as a numerical model, and the analyzed magnetic field distribution and predicted iron loss by using the proposed method is compared with those from a conventional method which employs an empirical iron loss formula with FEA based on a non-linear B-H curve. Through the comparison the effectiveness of the presented method for the iron loss prediction of the rotating machine is verified.

Effects of the insulation thickness on the magnetization loss of the multi-stacked YBCO coated conductor (절연거리 변화에 따른 적층된 YBCO 도체의 자화손실 변화)

  • Lim, Hyoung-Woo;Lee, Hee-Joon;Cha, Guee-Soo;Lee, Ji-Kwang
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.95-97
    • /
    • 2005
  • Loss in the multi-stacked HTS wires are affected by a number of factor, such as, number of wires used in the stack, direction of external magnetic field and insulation thickness between the wire. This paper examines the effects of the insulation thickness on the magnetization loss of the multi-stacked YBCO coated conductor. Measurements of magnetization loss were performed using 4 different typo of multi-stacked wires and under various angle of external magnetic field. Test results show that loss density per unit volume increased for YBCO coated conductors when thickness of insulation increased. Loss density per unit volume decreased for YBCO coaled conductors when stacking number of tapes increased.

  • PDF

A Study of Characteristic of Electrical-magnetic and Neutron Diffraction of Long-wire High-superconductor for Reducing Energy Losses

  • Jang, Mi-Hye
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.6
    • /
    • pp.265-272
    • /
    • 2008
  • In this paper, AC losses of long wire Bi-2223 tapes with different twist pitch of superconducting core were fabricated, measured and analyzed. These samples produced by a powder-in-tube method are multi-filamentary tape with Ag matrix. Also, it's produced by non-twist. The critical current measurement was carried out under the environment in Liquid nitrogen and in zero field by 4-prob method. And the Magnetic measurement was carried out under the environment of applied time-varying transport current by transport method. From experiment, the susceptibility measurements were conducted while cooling in a magnetic field. Flux loss measurements were conducted as a function of ramping rate, frequency and field direction. The AC flux loss increases as the twist-pitch of the tapes decreased, in agreement with the Norris Equation. Neutron-diffraction measurements have been carried out investigate the crystal structure, magnetic structures, and magnetic phase transitions in Bi-2223([Bi, Pb]:Sr:Ca:Cu:O).

Dielectric properties with variation of doped mount $ZrO_2$ of BSCT ceramics ($ZrO_2$첨가량에 따른 BSCT 세라믹의 유전특성)

  • 조현무;이성갑;이영희;배선기
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.153-156
    • /
    • 2001
  • (Ba$_{0.6-x}$Sr$_{0.4}$Ca$_{x}$)TiO$_3$ (x=0.10, 0.15, 0.20) ceramics were fabricated by the mixed-oxide method and their dielectric properties were investigated with variation of composition ratio, doped ZrO$_2$ (0.5, 1.0, 1.5, 2.0, 3.0 wt%) and sintered at 145$0^{\circ}C$. The dielectric constant and loss of the x=0.10 specimen applied field were 19.86 and 0.302 % at 0 V/cm, and 25.937 and 0.339 % at 300 V/cm, respectively. Dielectric constant were increased with increased applied field and decreased with increased frequency, and dielectric loss were within 0.1% at applied 800 MHz, respectively. all specimens showed fairly good applied field. Although, dielectric constant and loss of all specimen showed to tend of nearly the same. same.

  • PDF

Preparation of x-cut $LiNbO_3$ Optical Waveguide and the Change in Near-field Properties according to Ti thickness (x-cut $LiNbO_3$ 광도파로 제작 및 Ti 두께에 따른 Near-field 특성 변 화)

  • Kim, Seong-Ku;Yoon, Hyung-Do;Yoon, Dae-Won;Han, Sang-Pill;Kim, Chang-Min;Park, Gye-Chun;Lee, Jin;Yoo, Yong-Taek
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.2
    • /
    • pp.146-153
    • /
    • 1998
  • The optical near-field patterns, propagation loss and mode sizes of x-cut $Ti:LiNbO_3$ optical waveguide which was fabricated by Ti-diffusion varying with Ti strip thickness in wet oxygen atmosphere were discussed at optical wavelength 1550nm. As Ti thickness increased from $760{\AA}$, the insertion loss of waveguide was decreased. But at Ti thickness $1500{\AA}$, mode sizes are widely broadened. The Ti thickness of below $1100{\AA}$ and above $1500{\AA}$ showed negative effects to propagation loss and fiber coupling. The best Ti thickness for fabricating low propagation loss and good fiber coupling was inferred to be between $1100{\AA}-1500{\AA}$ in our conditions. And for Ti thickness $1150{\AA}$, its propagation loss, horizontal/vertical mode sizes were showed 1.61 dB/cm, $11.9/8.9{\mu}m$ for TM, 0.22 dB/cm, $12.0/9.1{\mu}m$ for TE respectively.

  • PDF