• 제목/요약/키워드: Loss distribution

검색결과 2,123건 처리시간 0.026초

마이크로파 실내 배전용 저반사형 전력 분배 스위치 (Low Loss Power Dividing Switch for Indoor Microwave Power Distribution)

  • 최영규
    • 전기학회논문지
    • /
    • 제62권1호
    • /
    • pp.90-94
    • /
    • 2013
  • A low loss power dividing switch in a indoor microwave power distribution system is proposed and designed with a various power dividing ratio. Switching characteristics are analyzed by use of the S-parameter of the switch. Newly proposed switch showed a very low return loss less than -30dB at the operating frequency of 2.45GHz. Three kinds of the switch in which we take out individually 1/2, 1/3 and 1/4 of the input power were fabricated, and measured the delivered, transmitted, and return loss power ratio. Simulated results showed that the lower power ratio is, the better accurate operating performance shows. This switch can switch the input power from 4.5% to 58% with the variance of 5% output power. The experimental results are in good agreement with the simulation within the return loss of 1%.

24MVA 몰드 변압기의 손실저감을 위한 Tie-Plate의 형상 최적설계 연구 (A Tie-plate Shape Optimization of 24MVA Cast Resin Transformer for Reduction of Stray Loss)

  • 김영배;신판석
    • 조명전기설비학회논문지
    • /
    • 제28권7호
    • /
    • pp.55-61
    • /
    • 2014
  • This paper presents a method to reduce the stray loss of core Tie-Plate of distribution power transformer. The method combines a 3-dimensional FEM with PSO(Particle Swarm Optimization) algorithm to determine the shape of the Tie-Plate that minimizes eddy current and flux-leakage losses. To verify the method a 24MVA distribution(cast-resin) transformer was simulated using one objective function and two design variables with some constraints. The final optimized Tie-Plate has nine($3{\times}3$) slots of 10mm width, 15mm thickness and 25mm distance. After four iterations, the Tie-Plate loss was reduced to about 21 % of the original.

Do Firms with Historical Loss Disclose Less Social Responsibility Information?

  • YIN, Hong
    • 산경연구논집
    • /
    • 제11권1호
    • /
    • pp.19-28
    • /
    • 2020
  • Purpose: This research aims to empirically investigate the motivation of corporate voluntary disclosure by exploring the impact of historical loss on corporate social responsibility disclosure (CSRD). Research design, data, and methodology: This paper takes Chinese A-share listed firms that issued standalone social responsibility reports during the period of 2009-2017 as a sample. Drawing on extant literature, this paper defines historical loss firms as firms with net profit greater than or equal to 0 and undistributed profit less than 0. The tendency score matching method (PSM) is used to find matching samples for historical loss firms. Then OLS regression is conducted to investigate the relationship between historical loss and corporate social disclosure. Results: The results show that historical loss has a significant positive impact on the quality of corporate social responsibility disclosure. After changing the measurement of independent and dependent variables as well as adopting different matching methods to screen the control group, the results still hold. Further research indicates that the relationship between historical loss and CSRD is influenced by corporate financing constraints and industry competition. Conclusions: This research supports the resource motivation hypothesis of corporate social responsibility disclosure, and provides empirical evidence for regulators to strengthen supervision on corporate disclosure.

취출구를 가진 덕트의 공기분배장치 설계 (Design Of Air-Distribution System in a Duct)

  • 강형선;조병기;고영하
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권8호
    • /
    • pp.954-960
    • /
    • 2007
  • The purpose of this paper is to obtain design method of air-distribution system. Air-distribution system is composed of blower, duct, diffusers and measuring equipment. The air-flow rate from each diffuser is not equal. The air-flow rate is calculated with the combined equations which are Bernoulli's equation, continuity equation and minor loss equations. Inlet condition and outlet condition are adapted in each duct system. Then square difference between function of maximum air-flow rate and minimum air-flow rate is used as an object function. Area of diffuser and velocity are established as constraints. To minimize the object function, the optimization method is used. After optimization the design variables are selected under satisfaction of constraints. The air-distribution system is calculated again with the result of optimized design variable. It is shown that the air-distribution system has the equal air-flow rate from diffusers.

50 kVA 주상용 몰드변압기의 설계 및 특성평가 (The Design and Performance Test of Mold Transformer for Outdoor Pole)

  • 조한구;이운용;황보국
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.132-137
    • /
    • 2002
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss. The life of transformer is significantly dependent on the thermal behavior in windings. To analyse winding temperature rise, many transformer designer have calculated temperature distribution and hot spot point by finite element method(FEM). Recently, numerical analyses of transformer are studied for optimum design, that is electric field analysis, magnetic field, potential vibration, thermal distribution and thermal stress. In this paper, the temperature distribution of 50 kVA pole mold transformer for power distribution are investigated by FEM program and the temperature rise test of designed mold transformer carried out and test result is analyzed compare to simulation data. In this result, the designed mold transformer is satisfied to limit value of temperature and the other property is good such as voltage ratio, winding resistance, no-load loss, load loss, impedance voltage and percent regulation.

  • PDF

부하불평형 및 부하모형을 고려한 복합배전계통의 분산형전원의 연계 방안 (Interconnection of Dispersed Generation Systems considering Load Unbalance and Load Model in Composite Distribution Systems)

  • 이유정;김규호;이상근;유석구
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권5호
    • /
    • pp.266-274
    • /
    • 2004
  • This paper presents a scheme for the interconnection of dispersed generator systems(DGs) based on load .unbalance and load model in composite distribution systems. Groups of each individual load model consist of residential, industrial, commercial, official and agricultural load. The unbalance is involved with many single-phase line segment. . Voltage profile improvement and system loss minimization by installation of DGs depend greatly on how they are placed and operated in the distribution systems. So, DGs can reduce distribution real power losses and replace large-scale generators if they are placed appropriately in the distribution systems. The main idea of solving fuzzy goal programming is to transform the original objective function and constraints into the equivalent multi-objectives functions with fuzzy sets to evaluate their imprecise nature for the criterion of power loss minimization, the number or total capacity of DGs and the bus voltage deviation, and then solve the problem using genetic algorithm. The method proposed is applied to IEEE 13 bus and 34 bus test systems to demonstrate its effectiveness.

통계적 분포를 통한 주택 화재 심도 추정 (Estimating home fire severity with statistical distributions)

  • 박윤정;송인아;이소연;남광현;오로지;안재윤
    • 응용통계연구
    • /
    • 제36권6호
    • /
    • pp.591-618
    • /
    • 2023
  • 본 논문은 보험 손실 추정을 위한 회귀 설정에서 다양한 분포 가정의 성능을 실제 데이터를 사용하여 비교 분석합니다. 감마 분포는 일반적으로 보험의 손실 분포의 비대칭성을 처리하는 데 사용됩니다. 그러나 최근 연구는 보험자료의 분석에 있어서 손실 분포의 두꺼운 꼬리의 중요성을 강조합니다. 실제 주택 화재 보험 데이터 분석을 통해 우리는 회귀 방법에서 다양한 분포 가정의 효과를 비교합니다. 우리의 결과는 보험손실에 대한 분포 가정의 선택이 "초과 손해 보험" 및 "한도 보험"을 포함한 다양한 보험 상품의 보험료 결정에 중요하다는 것을 보여줍니다. 또한 주택 화재 보험의 통계적 모형설정에 있어서 실제 고려 사항에 대해 논의합니다.

전자기파 부분방전 신호의 권선 투과 특성 (Partial Discharge Electromagnetic Wave Penetration Characteristics Throughout Transformer Winding)

  • 주형준;한기선;윤진열
    • 한국전기전자재료학회논문지
    • /
    • 제23권10호
    • /
    • pp.809-813
    • /
    • 2010
  • Frequency domain measurement of propagation loss for ultra high frequency (UHF) partial discharge in the winding of power transformer using a spectrum analyzer and pulse generator is presented. We compared the performance of the method using a network analyzer with and without a winding. Using a network analyzer simplifies the measurement and offers better dynamic range and frequency range. It also provides precise propagation loss within the winding in frequency domain at UHF range. We applied this method to measure UHF propagation loss of transformer mock-up, modeled 154 kV 20 MVA power in KEPCO substation.

배전계통 최적 재구성 알고리즘의 실계통 적용 (Application Optimal Reconfiguration Algorithm for Distribution Power System to KEPCO System)

  • 서규석;백영식;채우규
    • 전기학회논문지
    • /
    • 제57권10호
    • /
    • pp.1681-1687
    • /
    • 2008
  • This paper shows application of optimal reconfiguration algorithm for distributing power system to KEPCO system for loss minimization and load balancing. That is, it suggests additional algorithm to check potential problems caused in case of theoretical algorithm being applied to real system and recover from them. Also, comparing the results of reconfiguration algorithm Tabu-Search Algorithm applied to current KEPCO distribution power system and those of Branch Exchange Algorithm using initial operation point suggested in this paper, it shows how much the results are improved in aspects of load balancing, loss reduction and calculating time.

배전손실 최소화 문제에 있어서 유전알고리즘의 수속특성에 관한 연구 (An Application of Generic Algorithms to the Distribution System Loss Minimization Re -cofiguration Problem)

  • 최대섭;정수용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.580-582
    • /
    • 2005
  • This paper presents a new method which applies a genetic algorithm(GA) for determining which sectionalizing switch to operate in order to solve the distribution system loss minimization re-configuration problem. The distribution system loss minimization re-configuration problem is in essence a 0-1 planning problem which means that for typical system scales the number of combinations requiring searches becomes extremely large. In order to deal with this problem, a new a roach which applies a GA was presented. Briefly, GA are a type of random number search method, however, they incorporate a multi-point search feature. Further, every point is not is not separately and respectively renewed, therefore, if parallel processing is applied, we can expect a fast solution algorithm to result.

  • PDF