• Title/Summary/Keyword: Loss distribution

Search Result 2,123, Processing Time 0.033 seconds

Low Loss Power Dividing Switch for Indoor Microwave Power Distribution (마이크로파 실내 배전용 저반사형 전력 분배 스위치)

  • Choi, Young-Kyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.1
    • /
    • pp.90-94
    • /
    • 2013
  • A low loss power dividing switch in a indoor microwave power distribution system is proposed and designed with a various power dividing ratio. Switching characteristics are analyzed by use of the S-parameter of the switch. Newly proposed switch showed a very low return loss less than -30dB at the operating frequency of 2.45GHz. Three kinds of the switch in which we take out individually 1/2, 1/3 and 1/4 of the input power were fabricated, and measured the delivered, transmitted, and return loss power ratio. Simulated results showed that the lower power ratio is, the better accurate operating performance shows. This switch can switch the input power from 4.5% to 58% with the variance of 5% output power. The experimental results are in good agreement with the simulation within the return loss of 1%.

A Tie-plate Shape Optimization of 24MVA Cast Resin Transformer for Reduction of Stray Loss (24MVA 몰드 변압기의 손실저감을 위한 Tie-Plate의 형상 최적설계 연구)

  • Kim, Yong-Bae;Shin, Pan-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.7
    • /
    • pp.55-61
    • /
    • 2014
  • This paper presents a method to reduce the stray loss of core Tie-Plate of distribution power transformer. The method combines a 3-dimensional FEM with PSO(Particle Swarm Optimization) algorithm to determine the shape of the Tie-Plate that minimizes eddy current and flux-leakage losses. To verify the method a 24MVA distribution(cast-resin) transformer was simulated using one objective function and two design variables with some constraints. The final optimized Tie-Plate has nine($3{\times}3$) slots of 10mm width, 15mm thickness and 25mm distance. After four iterations, the Tie-Plate loss was reduced to about 21 % of the original.

Do Firms with Historical Loss Disclose Less Social Responsibility Information?

  • YIN, Hong
    • The Journal of Industrial Distribution & Business
    • /
    • v.11 no.1
    • /
    • pp.19-28
    • /
    • 2020
  • Purpose: This research aims to empirically investigate the motivation of corporate voluntary disclosure by exploring the impact of historical loss on corporate social responsibility disclosure (CSRD). Research design, data, and methodology: This paper takes Chinese A-share listed firms that issued standalone social responsibility reports during the period of 2009-2017 as a sample. Drawing on extant literature, this paper defines historical loss firms as firms with net profit greater than or equal to 0 and undistributed profit less than 0. The tendency score matching method (PSM) is used to find matching samples for historical loss firms. Then OLS regression is conducted to investigate the relationship between historical loss and corporate social disclosure. Results: The results show that historical loss has a significant positive impact on the quality of corporate social responsibility disclosure. After changing the measurement of independent and dependent variables as well as adopting different matching methods to screen the control group, the results still hold. Further research indicates that the relationship between historical loss and CSRD is influenced by corporate financing constraints and industry competition. Conclusions: This research supports the resource motivation hypothesis of corporate social responsibility disclosure, and provides empirical evidence for regulators to strengthen supervision on corporate disclosure.

Design Of Air-Distribution System in a Duct (취출구를 가진 덕트의 공기분배장치 설계)

  • Kang, Hyung-Seon;Cho, Byung-Ki;Koh, Young-Ha
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.8
    • /
    • pp.954-960
    • /
    • 2007
  • The purpose of this paper is to obtain design method of air-distribution system. Air-distribution system is composed of blower, duct, diffusers and measuring equipment. The air-flow rate from each diffuser is not equal. The air-flow rate is calculated with the combined equations which are Bernoulli's equation, continuity equation and minor loss equations. Inlet condition and outlet condition are adapted in each duct system. Then square difference between function of maximum air-flow rate and minimum air-flow rate is used as an object function. Area of diffuser and velocity are established as constraints. To minimize the object function, the optimization method is used. After optimization the design variables are selected under satisfaction of constraints. The air-distribution system is calculated again with the result of optimized design variable. It is shown that the air-distribution system has the equal air-flow rate from diffusers.

The Design and Performance Test of Mold Transformer for Outdoor Pole (50 kVA 주상용 몰드변압기의 설계 및 특성평가)

  • Cho, Han-Goo;Lee, Un-Yong;HwangBo, Kuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.132-137
    • /
    • 2002
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss. The life of transformer is significantly dependent on the thermal behavior in windings. To analyse winding temperature rise, many transformer designer have calculated temperature distribution and hot spot point by finite element method(FEM). Recently, numerical analyses of transformer are studied for optimum design, that is electric field analysis, magnetic field, potential vibration, thermal distribution and thermal stress. In this paper, the temperature distribution of 50 kVA pole mold transformer for power distribution are investigated by FEM program and the temperature rise test of designed mold transformer carried out and test result is analyzed compare to simulation data. In this result, the designed mold transformer is satisfied to limit value of temperature and the other property is good such as voltage ratio, winding resistance, no-load loss, load loss, impedance voltage and percent regulation.

  • PDF

Interconnection of Dispersed Generation Systems considering Load Unbalance and Load Model in Composite Distribution Systems (부하불평형 및 부하모형을 고려한 복합배전계통의 분산형전원의 연계 방안)

  • 이유정;김규호;이상근;유석구
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.5
    • /
    • pp.266-274
    • /
    • 2004
  • This paper presents a scheme for the interconnection of dispersed generator systems(DGs) based on load .unbalance and load model in composite distribution systems. Groups of each individual load model consist of residential, industrial, commercial, official and agricultural load. The unbalance is involved with many single-phase line segment. . Voltage profile improvement and system loss minimization by installation of DGs depend greatly on how they are placed and operated in the distribution systems. So, DGs can reduce distribution real power losses and replace large-scale generators if they are placed appropriately in the distribution systems. The main idea of solving fuzzy goal programming is to transform the original objective function and constraints into the equivalent multi-objectives functions with fuzzy sets to evaluate their imprecise nature for the criterion of power loss minimization, the number or total capacity of DGs and the bus voltage deviation, and then solve the problem using genetic algorithm. The method proposed is applied to IEEE 13 bus and 34 bus test systems to demonstrate its effectiveness.

Estimating home fire severity with statistical distributions (통계적 분포를 통한 주택 화재 심도 추정)

  • Yunjung Park;Inha Song;Soyoun Lee;Kwang Hyun Nam;Rosy Oh;Jaeyoun Ahn
    • The Korean Journal of Applied Statistics
    • /
    • v.36 no.6
    • /
    • pp.591-618
    • /
    • 2023
  • This paper evaluates the performance of various distribution assumptions in regression settings for estimating insurance loss. The gamma distribution is commonly used to handle the asymmetry property of loss distribution. However, recent studies highlight the significance of heavy-tailedness in loss distribution. Through an analysis of real home fire insurance data, we compare the effectiveness of different distribution assumptions in regression methods. Our findings show that the choice of parametric distributional assumption is crucial in determining premiums for various insurance products, including "excess of loss insurance" and "limit insurance". Additionally, we discuss practical considerations for applying our results in home fire insurance.

Partial Discharge Electromagnetic Wave Penetration Characteristics Throughout Transformer Winding (전자기파 부분방전 신호의 권선 투과 특성)

  • Ju, Hyung-Jun;Han, Ki-Son;Yoon, Jin-Yul
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.10
    • /
    • pp.809-813
    • /
    • 2010
  • Frequency domain measurement of propagation loss for ultra high frequency (UHF) partial discharge in the winding of power transformer using a spectrum analyzer and pulse generator is presented. We compared the performance of the method using a network analyzer with and without a winding. Using a network analyzer simplifies the measurement and offers better dynamic range and frequency range. It also provides precise propagation loss within the winding in frequency domain at UHF range. We applied this method to measure UHF propagation loss of transformer mock-up, modeled 154 kV 20 MVA power in KEPCO substation.

Application Optimal Reconfiguration Algorithm for Distribution Power System to KEPCO System (배전계통 최적 재구성 알고리즘의 실계통 적용)

  • Seo, Gyu-Seok;Baek, Yaung-Sik;Chae, Woo-Gyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1681-1687
    • /
    • 2008
  • This paper shows application of optimal reconfiguration algorithm for distributing power system to KEPCO system for loss minimization and load balancing. That is, it suggests additional algorithm to check potential problems caused in case of theoretical algorithm being applied to real system and recover from them. Also, comparing the results of reconfiguration algorithm Tabu-Search Algorithm applied to current KEPCO distribution power system and those of Branch Exchange Algorithm using initial operation point suggested in this paper, it shows how much the results are improved in aspects of load balancing, loss reduction and calculating time.

An Application of Generic Algorithms to the Distribution System Loss Minimization Re -cofiguration Problem (배전손실 최소화 문제에 있어서 유전알고리즘의 수속특성에 관한 연구)

  • Choi, Dai-Seub;Jung, Soo-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.580-582
    • /
    • 2005
  • This paper presents a new method which applies a genetic algorithm(GA) for determining which sectionalizing switch to operate in order to solve the distribution system loss minimization re-configuration problem. The distribution system loss minimization re-configuration problem is in essence a 0-1 planning problem which means that for typical system scales the number of combinations requiring searches becomes extremely large. In order to deal with this problem, a new a roach which applies a GA was presented. Briefly, GA are a type of random number search method, however, they incorporate a multi-point search feature. Further, every point is not is not separately and respectively renewed, therefore, if parallel processing is applied, we can expect a fast solution algorithm to result.

  • PDF