• 제목/요약/키워드: Loss analysis

검색결과 8,509건 처리시간 0.041초

송전손실을 고려한 온라인 경제급전 알고리즘 (On-Line Economic Dispatch Algorithm including Transmission Loss)

  • 전동훈;김건중;최장흠;장경철;임종호;이상중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.847-849
    • /
    • 1998
  • In this paper, we propose the generalized on-line economic dispatch algorithm including transmission loss. it was derived from the process developing matrix form of the classic ELD problem. it can rapidly calculate generation power using transmission loss and transmission loss sensitivity calculated from the result of power flow analysis. Transmission loss sensitivity ${\partial}P_{loss}/{\partial}P_G$ is derived using optimization technique.

  • PDF

Parameter Optimal Choice of Claw Pole Alternator based on Iron Loss Model

  • Bao, Xiaohua;Wei, Qiong;Wu, Feng;Li, Jiaqing
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권3호
    • /
    • pp.260-268
    • /
    • 2013
  • Based on classical Berotti discrete iron loss calculation model, the iron loss analysis mathematical model of alternator was proposed in this paper. Considering characteristics of high speed and changing frequency of the alternator, Maxwell 3-D model was built to analyze iron loss corresponding to each running speed in alternator. Based on iron loss model of alternator at rated speed, the rotor claw pole size was made an optimization design. The optimization results showed that alternator's output performance had been improved. A new idea was explored in size optimization design of claw pole alternator.

Analysis of Radio Interference through Ducting for 2.5 GHz WiMAX Service

  • Son, Ho-Kyung;Kim, Jong-Ho;Kim, Che-Young
    • Journal of electromagnetic engineering and science
    • /
    • 제12권1호
    • /
    • pp.94-100
    • /
    • 2012
  • Radio interference has been occurring in mobile communication services on the southern seashore in Korea. Monitoring the radio interference signal revealed that the main reason for the radio interference was a radio ducting signal coming from the seaside of Japan. In this paper, we have analyzed the effect of interference on WiMAX service using a 2.5 GHz frequency band between Korea and Japan. We focus on the interference scenario from base station to base station and we use the Minimum Coupling Loss (MCL) method for interference analysis and the Advanced Propagation Model (APM) for calculating the propagation loss in ducts. The propagation model is also compared with experimental measurement data. We confirm that the interfering signal strength depends on the antenna height and this result can be applied to deployment planning for each system with an interference impact acceptable to both parties.

제진 평판 진동에 대한 파워흐름해석 (Power Flow Analysis of Vibration of a Plate Covered with a Damping Sheet)

  • 이진영;길현권;송지훈;홍석윤
    • 한국소음진동공학회논문집
    • /
    • 제19권5호
    • /
    • pp.530-536
    • /
    • 2009
  • In this paper, the power flow analysis(PFA) has been used to analyze the vibration of a plate covered with a damping sheet. Experiments have been performed to measure the loss factor and frequency response functions of the plate covered with the damping sheet. The data for the loss factor has been used as the input data to predict the vibration of the coupled plates with PFA. The comparison between the experimental results and the predicted PFA results for the frequency response functions has been performed. It showed that PFA can be effectively used to predict structural vibration of a plate covered with a damping sheet in medium-to-high frequency range.

In-wheel 전동기의 열 등가회로 해석 및 유한요소해법을 이용한 열해석 (Thermal Analysis using Thermal Equivalent Circuit Analysis and Finite Element Method of In-wheel Motor)

  • 김규섭;이병화;홍정표;남혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.941-942
    • /
    • 2011
  • A thermal equivalent circuit of IPMSM considering eddy current loss of PM and core loss of rotor is proposed. This thermal equivalent model is represented by the thermal resistances and thermal capacitances. In order to determine the factor of each parameter, a heating test is processed. Additionally, the eddy current loss of PM is calculated by a transient 3D finite element analysis. Finally, this thermal equivalent model is verified by a temperature test in a 25kW 12-pole/18-slot IPMSM with varying load.

  • PDF

위상이동 방식 Full-Bridge 컨버터의 손실 분석에 관한 연구 (A Study on the Loss Analysis for the Phase-Shaft Full-Bridge Converter)

  • 배진용;김용;백수현;이은영;최근수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.157-162
    • /
    • 2003
  • This paper presents the loss analysis of Phase-Shift Full-Bridge Converter. Full-Bridge DC/DC Converter presented in this paper used a phase shift control in the primary side to achieve ZVS (Zero-Voltage-Switching) for main switch. Phase-Shaft Full-Bridge converter have an effect on the high power system. This paper analyses the loss of each component and the various losses in the circuit assessed. The result of the analysis are verified using 2.5kW, 50kHz prototype.

  • PDF

액체수소 저장용기의 열해석 (Thermal Analysis of a Liquid Hydrogen Vessel)

  • 김서영;강병하
    • 한국수소및신에너지학회논문집
    • /
    • 제8권2호
    • /
    • pp.57-65
    • /
    • 1997
  • Thermal analysis has been performed to design a high-performance $LH_2$ vessel with about 1% per day evaporation loss. Analysis includes the combined insulations of MLI(Multi-Layer Insulation) and VCS (Vapor-Cooled Shield) under high vacuum. Combined insulation of MLI and VCS shows the existence of optimal location of VCS to minimize evaporation loss. Comparison of parallel-type DVCS (Double Vapor-Cooled Shield) and serial-type DVCS is also made to show the effectiveness of the system. The results indicate that the serial-type DVCS vessel is better than the parallel-type DVCS vessel with respect to overall evaporation loss. The combined insulation of SVCS (Single Vapor-Cooled Shield) with a partial MLI can give a similar performance characteristics compared to that with MLI and DVCS.

  • PDF

심랭식공기분리공정에서 질소증류탑의 엑서지 해석 (Exergy Analysis of Nitrogen Distillation Column in the Cryogenic Air Separation Process)

  • 용평순;이성철
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.145-150
    • /
    • 2002
  • The distillation column is one of large energy consumable units in the cryogenic air separation process and the accurate energy analysis of this unit is necessary for choice of energy saving process. In this work, the energy method was adopted for energy analysis of a cryogenic nitrogen distillation column. In order to designing the energy saving distillation column, the exergy distribution of feed air, exergy efficiency and exergy loss for process condition was investigated and the optimal process condition to minimize the exergy loss was found. The result from this work can be used as a guideline for the choice of the process design conditions and efficiency improvement of cryogenic distillation column.

전류연속모드 승압형 컨버터의 효율 분석에 관한 연구 (A Study on the efficiency analysis of CCM boost converter)

  • 배진용;김용;이은영;권순도;조규만;엄태민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.920-921
    • /
    • 2008
  • This paper presents the efficiency analysis of CCM(Continuous Current Mode) boost converter. A thorough efficiency analysis of a boost converter taking into account the conduction losses, the diode power loss, the switching losses, the gate-drive loss and the capacitive switching loss, for both continuous conduction mode is presented.

  • PDF

고속 BLDC 전동기의 전자기 특성 해석 (Electromagnetic Characteristics Analysis of High-speed Brushless DC Motor)

  • 박형일;장석명;최장영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.916-917
    • /
    • 2015
  • This paper deals with electromagneitc characteristics analysis of high-speed brushless DC motor. First, under same rated and restricted conditions, four models which have different slot combinations each other are designed using 2-d finite element (FE) analyses. Designed models are analyzed and compared in terms of core loss, copper loss, eddy-current loss, etc. On the basis of analysis results, it is found that the motor with a 2-pole PM rotor and a 6-slot stator has most outstanding performances in electromagnetic aspects.

  • PDF