• Title/Summary/Keyword: Loss Rate

Search Result 5,253, Processing Time 0.039 seconds

Effect of Cooling Rate on the Behavior of the Embrittlement in Zircaloy-4 Cladding (냉각속도가 지르칼로이-4 피복관의 취성에 미치는 영향)

  • Kim, Jun Hwan;Lee, Myoung Ho;Choi, Byoung Kwon;Jeong, Yong Hwan
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.18 no.2
    • /
    • pp.112-118
    • /
    • 2005
  • Study was focused on the effect of the cooling rate on the embrittlement behavior of Zircaloy-4 cladding simulated Loss Of Coolant Accident (LOCA) environment. Claddings were oxidized at given temperature and given time followed by various water quenching in the range of $0.6^{\circ}C$ and $100^{\circ}C$ per second. Cladding failed after water quenching above the threshold oxidation. Threshold oxidation was decreased as the cooling rate increased, which is due to the matensite structure formed during fast cooling rate.

Prediction of small-scale leak flow rate in LOCA situations using bidirectional GRU

  • Hye Seon Jo;Sang Hyun Lee;Man Gyun Na
    • Nuclear Engineering and Technology
    • /
    • v.56 no.9
    • /
    • pp.3594-3601
    • /
    • 2024
  • It is difficult to detect a small-scale leakage in a nuclear power plant (NPP) quickly and take appropriate action. Delaying these procedures can have adverse effects on NPPs. In this paper, we propose leak flow rate prediction using the bidirectional gated recurrent unit (Bi-GRU) method to detect leakage quickly and accurately in small-scale leakage situations because large-scale leak rates are known to be predicted accurately. The data were acquired by simulating small loss-of-coolant accidents (LOCA) or small-scale leakage situations using the modular accident analysis program (MAAP) code. In addition, to improve prediction performance, data were collected by distinguishing the break sizes in more detail. In addition, the prediction accuracy was improved by performing both LOCA diagnosis and leak flow rate prediction in small LOCA situations. The prediction model developed using the Bi-GRU showed a superior prediction performance compared with other artificial intelligence methods. Accordingly, the accurate and effective prediction model for small-scale leakage situations proposed herein is expected to support operators in decision-making and taking actions.

TCP NJ+: Packet Loss Differentiated Transmission Mechanism Robust to High BER Environments (TCP NJ+ : 높은 BER에 강인한 패킷 손실 원인별 처리기반 전송방식)

  • Kim, Jung-Rae;Lee, You-Ho;Choo, Hyun-Seung
    • Journal of Internet Computing and Services
    • /
    • v.8 no.5
    • /
    • pp.125-132
    • /
    • 2007
  • Transmission mechanisms that include an available bandwidth estimation algorithm and a packet loss differentiation scheme, in general, exhibit higher TCP performance in wireless networks. TCP New Jersey, known as the best existing scheme in terms of goodput, improves wireless TCP performance using the available bandwidth estimation at the sender and the congestion warning at intermediate routers. Although TCP New Jersey achieves 17% and 85% improvements in goodput over TCP Westwood and TCP Reno, respectively, we further improve TCP New Jersey by exploring improved available bandwidth estimation, retransmission timeout, and recovery mechanisms. Hence, we propose TCP New Jersey PLUS (shortly TCP NJ+), showing that under 1% packet loss rate, it outperforms 3% by TCP New Jersey and 5% by TCP Wes1wood. In 5% packet loss rate, a characteristic of high bit-error-rate wireless network, it outperforms other TCP variants by 19% to 104% in terms of goodput even when the network is in bi-directional congestion.

  • PDF

Age-Related Bone Mineral Density, Accumulated Bone Loss Rate at Multiple Skeletal Sites in Korean Men (한국 남성의 연령에 따른 부위별 골밀도 변화 및 골 소실률)

  • Kim, Young-Ran;Lee, Tae-Yong;Lee, Ji-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3781-3788
    • /
    • 2014
  • This study examined the age-related bone mineral density (BMD), accumulated bone loss rate (ABLR) at different skeletal sites in Korean men using the data from the Korea National Health and Nutrition Examination Survey (KNHANES)(the 1st (2010), 2nd (2010) and the year at the 5th survey). The cubic regression model was found to be the best for describing the age-related changes in BMD. The lumbar spine, total hip, femoral neck, trochanter, Ward's triangle in the bone mineral density difference were analyzed by ANOVA. The peak BMD was at 20-24 years at the lumbar spine, total hip, femoral neck, trochanter, Ward's triangle, and the 75-79 years of age group had the highest Accumulated Bone Loss Rate. Therefore, intensive management will be necessary for men over 75 years, and a diagnosis of osteoporosis in Korean men should be made according to The International Society for Clinical Densitometry; ISCD.

Evaluation of Characteristic for SS400 and STS304 steel by Weld Thermal Cycle Simulation - 2nd Report: Corrosion Characteristics (용접열사이클 재현에 의한 SS400강 및 STS304강의 특성 평가 -제2보: 부식특성)

  • Ahn, Seok-Hwan;Choi, Moon-Oh;Kim, Sung-Kwang;Son, Chang-Seok;Nam, Ki-Wook
    • Journal of Ocean Engineering and Technology
    • /
    • v.21 no.5
    • /
    • pp.33-38
    • /
    • 2007
  • The welding methods have been applied in the most structural products from multi-field of automobile, ship construction and construction, and so on. The structure steel must have enough strength of structure. In this study, SS400 steel and STS304 steel were used to estimate the corrosion characteristics of the weld thermal cycle simulated HAZ. To evaluate the corrosion characteristics, also, the materials with two conditions were used in 3.5% NaCl. The one is to the drawing with diameter of ${\Phi}10$ and the other is to the residual stress removal treatment. The electrochemical polarization test and immersion test were carried out. From test results, corrosion potential, corrosion current density, weight loss ratio and corrosion rate were measured. In the kinds of SS400 steels, corrosion potential of weld thermal cycle simulated specimens after the heat treatment showed somewhat the direction of noble potential. And in the base metal to be drawing weight loss ratio and corrosion rate occurred higher than the other kinds. In the kinds of STS304 steels, the result of base metal to be drawing was similar to results of SS400 steels, too. Two kinds of $750^{\circ}C$ and $1300^{\circ}C$ of weld thermal cycle simulation after the heat treatment were rather higher than the other kinds in weight loss ratio and corrosion rate.

Two-short implant supported single molar restoration in atrophic posterior maxilla : a clinical study (위축된 상악구치부에서 두 개의 짧은 임플란트 지지형 단일치관의 임상연구)

  • Song, Ho-Yong;Heo, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of the Korean dental association
    • /
    • v.53 no.9
    • /
    • pp.628-643
    • /
    • 2015
  • Purpose: The aim of this retrospective study was to compare marginal bone loss and survival rates of double short implants(multiple implant) which had been installed and restored in severely atrophic maxillary molar site without a grafting procedure. Material and Method: The subjects were patients (90 patients, 180 implants) who had been installed double short implants in severely atrophic maxillary single molar site without bone augmentation procedure from 2006 to 2014 in dental clinic in Chuncheon city. Following data were collected from dental records and radiographic panoramic views: patient's age, gender, smoking status, implant site, timing of implant installation, residual ridge height. The correlation between those factors and survival rate and marginal bone loss were analyzed. Statistical analysis was performed using Chi-square test, Student's t- test and ANOVA. Result: Eleven implants in 6 patients failed and the cumulative survival rate was 93.9%. No significant differences were found in relation to the following factors: patient's age, gender, implant site, timing of implant installation (P> .05). There were significant differences in smoking status and residual ridge height(P< .05). The average follow-up time was $45{\pm}14.7months$. The mean marginal bone loss of survived 169 implants was $0.08{\pm}0.59mm$. Conclusion: Despite the short term outcomes, the survival rate of double short implants was comparable to normal length implants. This study demonstrated that placement of double short implants without the use of bone grafting procedure for severely atrophic posterior maxilla is a simple and predictable treatment procedure.

Optimization of Design Variables of Detection Algorithm for Loss of Balance Using a Linear Internal Model (균형상실의 검출 성능 향상을 위한 내부 모델의 설계변수 선정 및 민감도 평가)

  • Kim, Kwang-Hoon;Kim, In-Su;Son, Kwon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.9
    • /
    • pp.1153-1160
    • /
    • 2010
  • The detection algorithm for loss of balance had three main parts: one for processing data, another for constructing an internal model, and a third for detecting the loss of balance. The part related to the internal model is the most important part of the algorithm. The purpose of this study is to evaluate the effect of variables associated with the internal model on the success rate of the algorithm. The internal model depends on the type of linearization adopted and the operating period of the algorithm. The design variables were evaluated by performing sensitivity analysis of the variables of the internal model in order to obtain the success rate of the algorithm. The results showed that the most sensitive variable was the period and the period of 0.3 s yielded the highest success rate of 97.1%. Further, the ranges of the design variables that can facilitate a success rate of over 95% are presented.

The Performance Improvement for Congestion Control under TCP Traffic in Wireless Network (무선네트워크 전송기반에서 프로토콜에 의한 트래픽 혼잡제어)

  • Ra, Sang-Dong;Kim, Moon-Hwan;Lee, Sung-Joo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.10A
    • /
    • pp.965-973
    • /
    • 2007
  • We analyzed that the loss of data in TCP protocol based wireless networks caused by overlapped responses in bi-directional nodes that were resulted in out of the data sequence. This loss can be prevented by using revised TCP rate control algorithm and the performance of throughput can also be improved. The rate control algorithm is applied when the congestion happens between nodes while traffic packets are retransmitting in TCP bandwidth. In addition to applying the rate control algorithm, we determine the number of system clients in bandwidth and the average of pausing time between transmitting serial files to produce a competitive level so that an efficient performance of rapid retransmitting for the loss of multi-packets. This paper discusses the improvement of congestion control in that the decrease of the loss, firstly, as ensuring an efficient connection rate and, secondly, as using sliding window flow control.

Automatic Measurement of Respiration Rate and Weight Loss during Storage of Citrus fruits (과채류 저장시 호흡량과 중량감소의 자동계측)

  • Park, Je-Kyun;Chun, Jae-Kun;Lee, Seung-Koo;Kim, Kong-Hwan
    • Korean Journal of Food Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.387-390
    • /
    • 1989
  • Citrus fruit (Citrus unshiu Marc) were stored in the facillity controlled with a microprocessor-based storage controller, and the respiration rate and weight loss of fruits were measured with the infrared gas analyzer and the strain gauge load cell. The storage conditions and measuring intervals were set by the keyboard of personal computer. The interfacing cicuitry between the computer and Z-80 microprocerssor was built with peripheral Interfacing It chips 6821 and 8255. The data measured were saved to a data file for recording and further analysis. When the fresh and bruised fruits were subjected to the storage condition for 4 days at 20 C, the respiration rate of the fresh one showed a stable value of 3-5ml $CO_2/kg$ h throughout the storage period while the bruised one exihibited an abruptly increased rate after 50 hours. And the weight loss recorded about 5% during the storage.

  • PDF

The Efficacy of Stellate Ganglion Block in the Treatment of Idiopathic Sudden Sensorineural Hearing Loss (돌발성 난청에 있어서 성상신경절차단의 치료효과)

  • Chung, So-Young;Yoon, Duck-Mi;Lee, Myung-Hee;Oh, Hung-Kun
    • The Korean Journal of Pain
    • /
    • v.8 no.1
    • /
    • pp.65-73
    • /
    • 1995
  • Idiopathic sudden sensorineural hearing loss(SNHL) is defined as a sensorineural hearing loss which develops over a period of hours or few days without a definitive causes. The etiology, prognosis, and treatment of SNHL are uncertain. We reviewed records of 76 patients to investigate the efficacy of the stellate ganglion block(SGB)in SNHL. The control group(40 patients) was managed with the medication such as hypaque, heparin, steroid, nicotinic acid, and vitamine. The SGB group(27 patients) was managed with the same medication and SGB (1~2 times/day). The efficacy of treatment was evaluated by mean dB of 500, 1000, 2000 Hz on follow up pure tone audiogram. Recovery rate above 15dB was not different between SGB and the control group (52.4 v.s. 52.0%), though SGB group has much poor prognostic factors. Recovery rate was higher in a case that was treated early. Especially, the recovery rate was 100% when SGB begins within 2 weeks from the onset. Headache and profound type of audiogram were poor prognostic factors. In conclusion, SGB within 2 weeks from the onset is recommanded to improve the recovery rate.

  • PDF