• 제목/요약/키워드: Loss Head

검색결과 665건 처리시간 0.037초

입자분리효율을 높이기 위한 새로운 기술 (New Technologies for Enhancing Particles Separation Efficiency in Coagulation and Filtration)

  • Kunio, Ebie;Jang, Il-Hun
    • 상하수도학회지
    • /
    • 제18권2호
    • /
    • pp.254-269
    • /
    • 2004
  • Polysilicato-iron coagulant (PSI) is receiving attention in Japan as a substitute for aluminum-based coagulants. In the first part of this article, coagulation, sedimentation and filtration experiments were carried out using kaolin clay particles as the turbidizing material and four types of PSI with various molar ratios of polysilicic acid to ferric chloride (Si/Fe ratio). Results demonstrate that use of a PSI with a high Si/Fe ratio can cause a more dramatic decrease in treated water turbidity but a higher suction time ratio (STR) than when PACl is used. However, optimization by increasing the rapid agitation strength GR is found to greatly improve the STR. In addition, the series of filtration experiments verified that optimization of GR is greatly effective in controlling rapid increases in filter head loss, and also formation of a thin aging layer in the upper part of the filter bed by slow-start filtration is effective in improving filtered water turbidity over the entire filtration process. The second part of this article describes two innovative filtration techniques to increase the particle separation efficiency; (1) coagulant-coated filter medium by enhancing the electrical potential of the surface of the filter medium, and (2) coagulant dosing in influent by controlling the electrical potential of particles entering the filter layer. From the results of the various filtration experiments using a pilot plant, these two techniques were found to be very effective to reduce the effluent water turbidity from the start to the end of a filter run. Moreover, in the filtration experiments using these two methods simultaneously, higher removal efficiency of approximately 3-log (99.7%) was realized, resulting that the finished water turbidity was accordingly reduced to 0.004mg/L.

회유수조 제작 및 시험에 관한 연구 (A Study of Circulating Water Channel)

  • 장지원;하강열;이운희
    • 한국수산과학회지
    • /
    • 제18권1호
    • /
    • pp.8-14
    • /
    • 1985
  • 어구의 모형실험을 위한 회유수조를 제작하여 시험한 결과를 요약하면 다음과 같다. 1. 동력 50 H.P.의 D.C. Motor에 의하여 생기는 최대 유속은 약 2.3m/sec로서 지시전압 200 V, 지시전류 185 A에서 나타났다. 2. 유속과 전압과의 관계는 $0{\sim}1.0m/sec$까지는 비선형적으로 비례하나 1.0m/sec 이상에서 직선적으로 비례하였다. 3. 공칭 유속의 범위는 0.4m/sec에서 1.8m/sec까지이다. 그 이상으로 부터 최대 2.3m/sec까지는 수십분 이상 사용하며 모터의 과열현상이 나타났다 4. 수유 횡단면을 따르는 수직 유속분포는 수로중앙을 중심으로 좌우 약 70 cm까지는 0.2m/sec 이내의 차이를 나타냈다. 그러나 그 외부는 프로펠러의 크기, 벽과의 마찰로 인하여 급격히 감소한다. 5. 수심 중앙면을 따르는 수평적 유속 분포를 보면 유입부로 부터 관측부의 중앙까지는 수류변화가 거의 없으나 그 이후는 수로의 만곡에 따라 편향되었다.

  • PDF

회전근개 파열 증후군 (Rotator Cuff Tears Syndrome)

  • 강점덕;김현주
    • 대한정형도수물리치료학회지
    • /
    • 제13권1호
    • /
    • pp.67-72
    • /
    • 2007
  • Anatomy: The rotator cuff comprises four muscles-the subscapularis, the supraspinatus, the infraspinatus and the teres minor-and their musculotendinous attachments. The subscapularis muscle is innervated by the subscapular nerve and originates on the scapula. It inserts on the lesser tuberosity of the humerus. The supraspinatus and infraspinatus are both innervated by the suprascapular nerve, originate in the scapula and insert on the greater tuberosity. The teres minor is innervated by the axillary nerve, originates on the scapula and inserts on the greater tuberosity. The subacromial space lies underneath the acromion, the coracoid process, the acromioclavicular joint and the coracoacromial ligament. A bursa in the subacromial space provides lubrication for the rotator cuff. Etiology: The space between the undersurface of the acromion and the superior aspect of the humeral head is called the impingement interval. This space is normally narrow and is maximally narrow when the arm is abducted. Any condition that further narrows this space can cause impingement. Impingement can result from extrinsic compression or from loss of competency of the rotator cuff. Syndrome: Neer divided impingement syndrome into three stages. Stage I involves edema and/or hemorrhage. This stage generally occurs in patients less than 25 years of age and is frequently associated with an overuse injury. Generally, at this stage the syndrome is reversible. Stage II is more advanced and tends to occur in patients 25 to 40 years of age. The pathologic changes that are now evident show fibrosis as well as irreversible tendon changes. Stage III generally occurs in patients over 50 years of age and frequently involves a tendon rupture or tear. Stage III is largely a process of attrition and the culmination of fibrosis and tendinosis that have been present for many years. Treatment: In patients with stage I impingement, conservative treatment is often sufficient. Conservative treatment involves resting and stopping the offending activity. It may also involve prolonged physical therapy. Sport and job modifications may be beneficial. Nonsteroidal anti - inflammatory drugs(NSAIDS) and ice treatments can relieve pain. Ice packs applied for 20 minutes three times a day may help. A sling is never used, because adhesive capsulitis can result from immobilization.

  • PDF

하이브리드 자동차 보조전원 공급용 DC-DC 컨버터 개발 (Development of DC-DC Converter for Ancillary Power Supply in Hybrid Electric Vehicle)

  • 김종철;최덕관;박해우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.261-265
    • /
    • 2005
  • 본 논문에서는 하이브리드 자동차용 보조전원 공급이 목적인 DC-DC Converter에 대하여 기술하였다. DC-DC Converter는 차량 내의 헤드램프, 오디오, 각종 ECU등 전기/전자 부하에 전력을 공급하며 또한 12V 보조 배터리를 충전하는데 사용된다. 고주파 동작 조건하에서 유기되는 전자파 노이즈와 스위칭 손실을 저감하기 위하여 컨버터 토폴로지로 위상천이 영전압 풀브리지 방식을 적용하였으며 제어기의 용이한 보상 및 안정된 시스템 응답 특성을 위하여 슬로프 보상이 포함된 전류 모드 제어방식을 사용하였다 정전압/정전류 충전 제어 방식은 전기부하에 안정적인 전원공급과 보조 배터리의 안정적인충전을 보장한다. 초기의 회로 파라메타 설정 및 하드웨어 디버깅을 위하여 시뮬레이션 툴로 PSIM 6.0을 사용하였으며. DC-DC Converter에서 스위칭 소자의 발열문제는 Thermo Tracer 장비를 사용하여 개선하였다.

  • PDF

Sjogren 증후군과 동반된 Monocytoid B-Cell Lymphoma 1례 (A Case of Monocytoid B-Cell Lymphoma Associated with Sjogren Syndrome)

  • 이정훈;백상흠;양훈식;홍영호
    • 대한기관식도과학회지
    • /
    • 제6권1호
    • /
    • pp.102-107
    • /
    • 2000
  • Monocytoid B-cell lymphoma is uncommon, low grade lymphoma originating from monocytoid B lymphocytes. Monocytoid B-cell lymphoma usually presents as a localized lymphadenopathy. Peripheral lymph nodes are most often involved, particularly those in the frequent in the head and neck area. A distinctive feature is the association of monocytoid B-cell lymphoma with autoimmune diseases. Sjogren Syndrome had been present in 22% of patient with monocytoid lymphoma. Extranodal involvement by monocytoid lymphoma was reported in the salivary gland, breast, thyroid, and stomach. There were also occasional extensions to the liver and retroperitoneum. The bone marrow and peripheral blood involvement by monocytoid lymphoma is very rare, which is frequently seen in hairly cell leukemia. Fever, weight loss, and other constitutional signs are usually absent. Most patients have no symptoms, and the only sign is enlarged lymph nodes. The clinical course remains indolent; most patients are in complete remission and recurrence with progression to a high-grade lymphoma of large cell type was recorded only in a few cases. Authors experienced a case of monocytoid B-cell lymphoma associated with Sjogren Syndrome mistaken to simple cervical lymphadenitis in a 60-year-old female. We report this case with a review of literatures.

  • PDF

Modern Paper Quality Control

  • Komppa, Olavi
    • 펄프종이기술
    • /
    • 제32권5호
    • /
    • pp.72-79
    • /
    • 2000
  • On the other hand, the fiber orientation at the surface and middle layer of the sheet controls the bending stiffness of paperboard. Therefore, a reliable measurement of paper surface fiber orientation gives us a magnificent tool to investigate and predict paper curling and cockling tendency, and provides the necessary information to fine-tune the manufacturing process for optimum quality. Many papers, especially heavily calendered and coated grades, do resist liquid and gas penetration very much, being beyond the measurement range of the traditional instruments or resulting inconveniently long measuring time per sample. The increased surface hardness and use of filler minerals and mechanical pulp make a reliable, non-leaking sample contact to the measurement head a challenge of its own. Paper surface coating causes, as expected, a layer which has completely different permeability characteristics compared to the other layers of the sheet. The latest developments in sensor technologies have made it possible to reliably measure gas flow n well controlled conditions, allowing us to investigate the gas penetration of open structures, such as cigarette paper, tissue or sack paper, and in the low permeability range analyze even fully greaseproof papers, silicon papers, heavily coated papers and boards or even detect defects in barrier coatings! Even nitrogen or helium may be used as the gas, giving us completely new possibilities to rank the products or to find correlation to critical process or converting parameters. All the modern paper machines include many on-line measuring instruments which are used to give the necessary information for automatic process control systems. Hence, the reliability of this information obtained from different sensors is vital for good optimizing and process stability. If any of these on-line sensors do not operate perfectly as planned (having even small measurement error or malfunction), the process control will set the machine to operate away from the optimum, resulting loss of profit or eventual problems in quality or runnability. To assure optimum operation of the paper machines, a novel quality assurance policy for the on-line measurements has been developed, including control procedures utilizing traceable, accredited standards for the best reliability and performance.

  • PDF

Foramen Magnum Decompression with Adipose Tissue Grafting for Caudal Occipital Malformation Syndrome in a Maltese Dog

  • Park, Sung-Guon;Moon, Hee-Sup;Kim, Sang-Yeon;Hong, Su-Bin;Kim, Tae-Hwan;Hwang, Tae-Sung;Lee, Sung-Lim;Lee, Hee-Chun;Park, Hyun;Lee, Jaehoon
    • 한국임상수의학회지
    • /
    • 제33권6호
    • /
    • pp.381-384
    • /
    • 2016
  • A 7-year-old intact female Maltese dog was referred to the hospital with a history of paresis in the hind limbs, left head turn, and a loss of balance that persisted for 2 weeks. Her condition was initially managed with steroids, prescribed by the referring veterinarian, but her neurological symptoms were not alleviated. Physical and neurological examinations, radiography, computed tomography, and magnetic resonance imaging were performed. Based on the findings on these examinations, caudal occipital malformation syndrome (COMS) with syringohydromyelia was diagnosed. Medical treatment was not effective in the previous trial; therefore, foramen magnum decompression, durotomy, and free autogenous adipose tissue grafting were performed. After 3 days, an improvement was observed in the clinical symptoms and was maintained for 8 months postoperatively. Based on the results, it is suggested that the decompression method with a fat graft may be considered an effective surgical treatment for the management of COMS that did not respond well to previous medical treatment.

4방향 합류맨홀 내부의 인버트 설치에 따른 손실계수 산정 (Estimation of Head Loss Coefficients with Change of Invert Type in Four-Way Combining Manholes)

  • 류택희;김정수;윤세의
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2016년도 학술발표회
    • /
    • pp.465-465
    • /
    • 2016
  • 관거시설은 관거, 맨홀(manhole), 우수토실, 물받이, 연결관, 침투시설, 저류시설, 펌프장 등을 포함하는 시설들로 구성되어 있다. 여기서 맨홀은 배수시설의 유지와 관리를 위하여 일정거리마다 설치되고 있으며, 관거의 기점, 방향, 경사 및 관경이 변하는 곳, 단차가 발생하는 곳, 관거가 합류하는 곳에는 반드시 설치한다(환경부, 2011). 그러나 하수도시설기준(환경부, 2011)에서 합류맨홀의 설치에 관한 사항은 T형 합류맨홀에 관한 개략적인 표만 제시되어 있을 뿐, 4방향 합류맨홀에 대한 구체적인 설치 기준이 제시되어 있지 않은 실정이다. 또한 에너지 손실의 저감 및 배수능력을 증대시키기 위하여 맨홀내 설치되는 인버트는 미국의 형태 및 기준을 그대로 적용하고 있으므로 관거시설의 시설의 합리적인 설계기준을 제시하기 위하여 인버트가 설치된 4방향 합류맨홀에서의 흐름특성 및 수두 손실을 분석할 필요가 있다. 본 연구에서는 인버트가 설치된 4방향 합류맨홀 손실계수 산정 및 흐름특성을 분석하기 위하여 문헌조사 및 현장조사를 실시하여 수리실험 장치를 제작하였다. 실험에 사용된 맨홀은 하수도시설기준(환경부, 2011)의 표준 1호 맨홀을 1/5로 축소하였고, 인버트는 설치되지 않은 조건(CASE A), 반원형 인버트(CASE B), U형 인버트(CASE C)를 각각 실험하였으며, 실험유량으로 총 유출량 (Qout)은 $2{\sim}5{\ell}/sec$, 총 유출량에 대한 측면 유입량($Q_{Lat}$)의 비($Q_{Lat}/Q_{out}$)는 0~1 조건으로 변화시키면서 흐름특성 및 손실계수를 산정하였다. 실험결과 측면유량비가 증가함에 따라 CASE B와 CASE C는 CASE A보다 맨홀 내 수심이 약 3~7%정도 증가되는 경향을 나타내고 있었으며, 측면유량비의 증가에 따른 손실계수 산정 결과, CASE B는 CASE A 보다 약 30%정도 손실계수가 증가하였으며, CASE C는 CASE A보다 약 35%정도 손실계수가 증가하는 것으로 나타났다. 이는 기존에 사용되고 있는 인버트의 형상이 4방향 합류맨홀에서의 손실 저감 및 배수능력을 증대시키기 보다는 오히려 맨홀 내 통수능력을 저하시켜 4방향 합류맨홀에서의 배수능력을 저감시키는 것으로 분석되었다. 그러므로 기 사용되는 인버트의 개선이 필요하며 관거시설의 배수능력을 증대하기 위하여 지속적인 연구를 통한 개선된 인버트의 형상 제시가 필요할 것으로 판단된다.

  • PDF

연료전지용 소형 금속 열교환기의 성능에 대한 실험 및 이론적 연구 (Study on Experimental and Theroretical performances for a Compact Metallic Heat Exchanger for Fuel Cell Systems)

  • 윤영환;팽진기
    • 한국태양에너지학회 논문집
    • /
    • 제31권4호
    • /
    • pp.9-18
    • /
    • 2011
  • This study assessed the performance of a compact heat exchanger with staggered tube banks for recuperation of high temperature exhaust thermal energy for SOFC fuel cell system. The compact heat exchanger in this study is two pass system which consists of $315{\times}202.5{\times}48.5mm^3$ and 132 tubes of $6.0mm{\Phi}$ for each heat exchanger. From experiments of the 2 pass heat exchanger system, air temperature was increased from $60{\sim}85^{\circ}C$ to $402{\sim}482^{\circ}C$ while gas temperature was decreased from $600^{\circ}C$ to $305{\sim}402^{\circ}C$ according to mass flow rates of 3.9~7.8 g/s. The experimental heat transfer rates of the heat exchanger were compared with CFD numerical solutions with the conventional ${\xi}-NTU$ method. From the comparisons, the following conclusions were obtained. For the heat exchanger system, the relative errors of heat transfer rate by CFD solution were from 7.1 to 27%, and those by ${\xi}-NTU$ method were from 0.6% to 21% compared with experimental data. From the comparisons, it can be said that both of CFD and ${\xi}-NTU$ method almost simulated to experimental data except specific conditions. Pressure drops through air tubes and gas passages were calculated with both of the CFD computation and head loss equations. The differences between them were from 14 to 22%.

Enteric methane emissions, energy partitioning, and energetic efficiency of zebu beef cattle fed total mixed ration silage

  • Subepang, Sayan;Suzuki, Tomoyuki;Phonbumrung, Thamrongsak;Sommart, Kritapon
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제32권4호
    • /
    • pp.548-555
    • /
    • 2019
  • Objective: The main objective of this study was to evaluate the effect of different feeding levels of a total mixed ration silage-based diet on feed intake, total tract digestion, enteric methane emissions, and energy partitioning in two beef cattle genotypes. Methods: Six mature bulls (three Thai natives, and three Thai natives - Charolais crossbreeds) were assigned in a replicated $3{\times}3$ Latin square design, with cattle breed genotype in separate squares, three periods of 21 days, and three energy feeding above maintenance levels (1.1, 1.5, and 2.0 MEm, where MEm is metabolizable energy requirement for maintenance). Bulls were placed in a metabolic cage equipped with a ventilated head box respiration system to evaluate digestibility, record respiration gases, and determine energy balance. Results: Increasing the feeding level had no significant effect on digestibility but drastically reduced the enteric methane emission rate (p<0.05). Increasing the feeding level also significantly increased the energy retention and utilization efficiency (p<0.01). The Thai native cattle had greater enteric methane emission rate, digestibility, and energy utilization efficiency than the Charolais crossbred cattle (p<0.05). The daily metabolizable energy requirement for maintenance in Thai native cattle ($388kJ/kg\;BW^{0.75}$, where $BW^{0.75}$ is metabolic body weight) was 15% less than that in Charolais crossbred cattle ($444kJ/kg\;BW^{0.75}$). Conclusion: Our results suggested that the greater feeding level in zebu beef cattle fed above maintenance levels resulted in improved energy retention and utilization efficiency because of the reduction in enteric methane energy loss. The results also indicated higher efficiency of metabolisable energy utilization for growth and a lower energy requirement for maintenance in Bos indicus than in Bos taurus.