• 제목/요약/키워드: Loop-pipe

검색결과 167건 처리시간 0.026초

지역난방배관의 누수감지 신뢰성 향상에 관한 연구 (A Study on the Improvement of Water-Leakage Detection Reliability in Local Heating System)

  • 신춘식;안영주;변기식
    • 한국안전학회지
    • /
    • 제14권1호
    • /
    • pp.66-72
    • /
    • 1999
  • Local heating transportation pipe has sensor and return lines to detect water-leakage. There are impulse and resistance comparison measurement types for a water-leakage detection. The impulse type shows large detection error within a measurement range. Since the resistance comparison type can find a comparative accurate single water-leakage point in the measurement range of heating pipe, it has been used to detect water-leakages these days. However if the multi water-leakages are happened in the measurement range of transportation pipe. the resistance comparison type shows a detection error point by the parallel resistance between a detection sensor line and ground. But the detection error will be minimized by the divided transportation pipe loops. In this research, it suggests the design of remote controlled detection system which can divide a large pipe loop and a possible single water-leakage measurement process in each divided loops.

  • PDF

상수관망의 관로파열 영향 해석 (Analysis of Pipe-Burst effect in Water Distribution Network)

  • 박재홍
    • 한국수자원학회논문집
    • /
    • 제35권6호
    • /
    • pp.665-675
    • /
    • 2002
  • 상수관망에서 관로파열을 예측하고 파열영향을 감소시키는 작업은 관망의 신뢰도와 밀접한 관계가 있다. 기존의 상수관망의 설계에서는 관로의 배치 및 각 관로에 대한 수리학적 능력 및 파열에 대한 영향이 고려되지 않았다. 본 연구에서는 도학을 이용하여 상수관망의 기하학적 구성상태에 따른 관로 파열에 대한 영향을 예측하고 영향을 감소시켜 상수관망의 신뢰도를 증가시킬 수 있는 방법을 제시하였다. 기존의 상수관망은 폐합관로를 이루고 있지만 특정관로가 파열되었을 경우 적정한 유량공급이 불가능하여 관망의 대부분의 절점에 심각한 수두감소와 같은 부작용이 발생할 수 있었다. 본 연구에서 개발된 관로파괴 영향해석 기법을 이용하여 관망 설계시 적절한 관경 및 관로를 배치를 구성하여 관로 파괴시 발생하는 수요절점에서의 극단적인 수두감소를 극복할 수 있었고 사용자들에게 안정적인 유량공급이 가능하여 보다 신뢰성 있는 상수관망 시스템이 될 수 있었다.

분지관 혼합기의 난류혼합에 대한 유동가시화 연구(III) (Flow Visualization Study on the Turbulent Mixing of Two Fluid Streams (III))

  • 김경천;신대식;박기영
    • 대한기계학회논문집B
    • /
    • 제22권11호
    • /
    • pp.1571-1581
    • /
    • 1998
  • A flow visualization study was carried out for the branch pipe mixing flow in which a jet was issued normally to the fully developed pipe flow. An instantaneous laser tomographic method was used for cross flow Reynolds numbers based on the cross flow diameter D ranged $Re_{cf}=5.26{\times}10^3{\sim}1.13{\times}10^4$, diameter ratios d/D = 0.1 ~ 0.2 and velocity ratios R = 0.5 ~ 10. Oil mist with the size of about $10{\mu}m$ diameter was used for the scattering particle. The main purpose of this study was to reveal the physical mechanism and the structure of vortices formation with varying the velocity ratios and diameter ratios in the branch pipe flow. It was found that the physical mechanism and the structures of vortices formation were quite different depending on the velocity ratios. Particularly in the case of R < 1, the typical vortex shows single loop shape and that for the case of R > 1 depicts mushroom-like structure in the cross flow jet.

다양한 작동유체로 충전된 폐쇄 루프 맥동 히트파이프 내부 유동패턴 비교 (A comparative study on the flow patterns in closed loop pulsating heat pipe charged with various working fluids)

  • 강석구;김성근;히발 아흐메드;정성용
    • 한국가시화정보학회지
    • /
    • 제17권3호
    • /
    • pp.52-58
    • /
    • 2019
  • Thermal performance and flow patterns inside the closed loop pulsating heat pipe (CLPHP) were experimentally investigated. For investigating the effect of working fluids, CLPHP was filled with various working fluids including methanol, acetone and ethanol. The thermal resistance was calculated by temperatures in evaporator and condenser and flow patterns were visualized by a digital camera. The thermal resistances for all fluids were decreased as the heat increases. Flow patterns change from static slug to elongated slug flows, bulk circulation and annular flows as the heat increases. Dry-out occurs after annular flows. For reasonable comparison of thermal performances, normalized CHF, Kutateladze number (Ku), was compared. Even though ethanol has smallest CHF, Ku of ethanol is similar with that of methanol. In addition, acetone has the highest Ku that means CLPHP with acetone provides the higher thermal performance compared with CLPHP with other fluids.

곡선부의 구조 특성을 고려한 선박용 파이프 루프 설계식 개발 (Development of Design Formulas for Pipe Loops Used in Ships Considering the Structural Characteristics of Curved Portions)

  • 박치모;배병일
    • 한국해양공학회지
    • /
    • 제26권5호
    • /
    • pp.87-93
    • /
    • 2012
  • Many longitudinally-arranged pipes in ships are equipped with loops as a measure to reduce stresses caused by displacement loads conveyed from the hull girder bending and/or thermal loads of carried fluid of non-ambient temperature. But as the loops have some negative effects such as causing extra manufacturing cost and occupying extra space, the number and the dimensions of the loops need to be minimized. In the meanwhile, a design formula for pipe loops has been developed by modeling them as a spring element of which stresses and axial stiffness are calculated based on the beam theory. But as the beam theory turns out to be inappropriate to deal with the complex structural behavior in the curved corner portion of the loop, this paper aims at improving the previously developed design formula by adopting correction factors which can allow for the gap between the results of beam theory and a more accurate analysis. This paper adopts a finite element analysis with two-dimensional shell elements with some validation work for it. The paper ends with a sample application of the proposed formulas showing their accuracy and efficiency.

Application of corrosion inhibitors to water distribution systems

  • Park, Yong-Il;Woo, Dal-Sik;Cho, Young-Tai;Jo, Kwan-Hyung;Nam, Sang-Ho
    • 한국환경과학회지
    • /
    • 제11권5호
    • /
    • pp.411-418
    • /
    • 2002
  • The current study evaluated the disinfection efficiency of free chlorine and chloramine for microorganisms on various pipe materials, such as copper, galvanized steel, carbon steel, and stainless steel. In addition, the effect of internal pipe corrosion and corrosion inhibitors on the bactericidal efficiency was evaluated using a simulated loop. For disinfection with a phosphate corrosion inhibitor, chloramination was found to be more effective than chlorination due to its persistence. Free chlorine disinfection was optimized with a high phosphoric acid concentration, while chloramine disinfection was optimized with a high phosphoric acid or low polyphosphate concentration. In simulated copper and galvanized steel loop tests, chloramination with phosphoric acid was demonstrated to be more effective.

황동소결윅-물 LHP의 작동 특성에 관한 연구 (Study on a Operating Characteristics of Loop Heat Pipe Using a Brass Sintered Metal Wick-Water)

  • 이욱현;이기우;박기호;이계중;노승용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1528-1533
    • /
    • 2004
  • In this study, we have manufactured the LHP(Loop Heat Pipe) with sintered metal wick and investigated the working characteristics of LHP experimentally.Water was used as a working fluid and fill charge rate was changed. LHP basically consist of the separated vapor/liquid channels, evaporator having sintered metal wick(effective pore diameter :$16{\sim}19{\mu}m$), and condenser cooled by water. The diameter of vapor/liquid line tube are 3.2mm/6.35mm, respectively. Heat transfer rate and thermal resistance was represented to study the basic characteristics of LHP at each conditions

  • PDF

루프디자인에 따른 배관시스템의 열응력에 관한 연구 (A Study on Thermal Stress of Power Piping due to Loop Design)

  • 이정현;박지성
    • 한국생산제조학회지
    • /
    • 제23권5호
    • /
    • pp.450-455
    • /
    • 2014
  • Domestic power plants have consistently been developed over the years in industrially developed nations with high standards of living. Considering the power plant development strategy, design efficiency is of upmost importance. Therefore, an improper design directly affects the power plant's risk management plan and the potential risks of the piping system. Therefore, in this study, research is intended to be carried out to allow efficient power plant operation, through optimization of the design of the piping system. The purpose of the study is to confirm economic feasibility by changing the piping loop design, expanding the length of pipe loops, and to investigate the thermal stress influence on the piping system through simulations of systems similar in condition to those currently used in existing plants in Korea.

루프 히트파이프의 작동에 영향을 미치는 인자에 대한 이론적 분석 (A Theoretical Analysis on the Factors Affecting the Operation of Loop Heat Pipe)

  • 이기우;전원표;이욱현;박기호
    • 설비공학논문집
    • /
    • 제16권12호
    • /
    • pp.1107-1116
    • /
    • 2004
  • In this paper, the effects of diverse parameters on the operation of loop heat pipe (LHP), such as particle diameter of sintered porous wick, wick porosity, vapor line diameter, thickness of wick and heating capacity were investigated by a theoretical analysis. A LHP has a wick only in its evaporator for the circulation of working fluid, and utilizes a porous wick structure of which pore size is very small to obtain a large capillary force. The working fluid is water and the material of sintered porous wick is copper. For these different parameters, capillary pressure, pressure drop in wick, pressure drops and temperature distribution were analyzed by a theoretical design method of LHP.

Remote Nozzle Blocking Device of RCS Pipe during Mid-Loop Operation in Nuclear Power Plants

  • Kang, Ki-Sig;Lee, Se-Yub;Chi, Ham-Chung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(1)
    • /
    • pp.571-576
    • /
    • 1996
  • Currently most nuclear power plants(NPPs) are adopted the mid-loop operation to minimize the overhaul period and save the operating cost. For mid-loop operation it is essential to install nozzle dam between RCS pipe and steam generator(SG). Because SG remains more highly contaminated with radioactive material than any other parts of the NPPs, the repairmen are very reluctant to carry out installing nozzle dam inside the SG. Until now, unfortunately, it appears that no practically applicable device was developed to provide the longstanding demand. Also the accidents have been reported by licenser event report during this operation mode due to loss of residual heat removal(RHR). The purpose of this paper is to conduct remotely blocking and disintegration of nozzle of a SG which has the highest radiation exposure during the maintenance in NPPs. The remote nozzle blocking device of a SG includes three bladders, hubs, air controller provisions to supply and contact air pressure into the bladders. This remote nozzle block device will give the larger operation margin to prevent the loss of RHR and minimize the radiation exposure dose to the repairman and shorten the overhaul periods.

  • PDF