Study on the Capacity Design Tool Development for Open-loop Ground Heat Exchanger (개방형 지중열교환기 용량 설계 방법에 관한 연구)

  • Ryu, Hyung-Kyou;Choi, Seung-Hyuck;Yun, Hi-won;Gim, Yu-Seung
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.13 no.2
    • /
    • pp.9-15
    • /
    • 2017
  • When applying geothermal systems in cities such as seoul where high density development prevails, the selection of geothermal system capable of obtaining a large capacity in the limited grounds is necessary. In this study, an easy-to-use design tool is developed in the form of spreadsheet by applying the calculation theory of existing closed-loop vertical ground heat exchanger that can be used in the early design stage of the open-loop ground heat exchanger. By only using the maximum cooling and heating load, it is possible to calculate optimal design open-loop ground heat exchanger. Further research is needed, we are plan to improve the program considering the heat loss of groundwater flowing in the inner casing, G-Function for Open-Loop, and verification by applying actual projects.

An Estimation Methodology of Empirical Flow-density Diagram Using Vision Sensor-based Probe Vehicles' Time Headway Data (개별 차량의 비전 센서 기반 차두 시간 데이터를 활용한 경험적 교통류 모형 추정 방법론)

  • Kim, Dong Min;Shim, Jisup
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.21 no.2
    • /
    • pp.17-32
    • /
    • 2022
  • This study explored an approach to estimate a flow-density diagram(FD) on a link in highway traffic environment by utilizing probe vehicles' time headway records. To study empirical flow-density diagram(EFD), the probe vehicles with vision sensors were recruited for collecting driving records for nine months and the vision sensor data pre-processing and GIS-based map matching were implemented. Then, we examined the new EFDs to evaluate validity with reference diagrams which is derived from loop detection traffic data. The probability distributions of time headway and distance headway as well as standard deviation of flow and density were utilized in examination. As a result, it turned out that the main factors for estimation errors are the limited number of probe vehicles and bias of flow status. We finally suggest a method to improve the accuracy of EFD model.

Where is the coronal loop plasma located, within a flux rope or between flux ropes?

  • Lim, Daye;Choe, G.S.;Yi, Sibaek
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.66.3-67
    • /
    • 2015
  • Without scrutinizing reflection, the plasma comprising a coronal loop is usually regarded to reside within a flux rope. This picture seems to have been adopted from laboratory plasma pinches, in which a plasma of high density and pressure is confined in the vicinity of the flux rope axis by magnetic tension and magnetic pressure of the concave inward magnetic field. Such a configuration, in which the plasma pressure gradient and the field line curvature vector are almost parallel, however, is known to be vulnerable to ballooning instabilities (to which belong interchange instabilities as a subset). In coronal loops, however, ideal MHD (magnetohydrodynamic) ballooning instabilities are impeded by a very small field line curvature and the line-tying condition. We, therefore, focus on non-ideal (resistive) effects in this study. The footpoints of coronal loops are constantly under random motions of convective scales, which twist individual loop strands quite randomly. The loop strands with the axial current of the same direction tend to coalesce by magnetic reconnection. In this reconnection process, the plasma in the loop system is redistributed in such a way that a smaller potential energy of the system is attained. We have performed numerical MHD simulations to investigate the plasma redistribution in coalescence of many small flux ropes. Our results clearly show that the redistributed plasma is more accumulated between flux ropes rather than near the magnetic axes of flux ropes. The Joule heating, however, creates a different temperature distribution than the density distribution. Our study may give a hint of which part of magnetic field we are looking to in an observation.

  • PDF

Design and Performance Test of a Closed Loop Thermal Control System for Thermal Vacuum Chamber (열진공 챔버용 폐회로 열제어시스템 설계 및 성능평가)

  • Seo, Heejun;Cho, Hyokjin;Park, Sungwook;Moon, Gueewon;Jung, Sanghun;Huh, Hwanil
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.1
    • /
    • pp.88-97
    • /
    • 2016
  • A closed loop thermal control system simulates space thermal environment to verify the satellites' functionality in extremely cold/hot temperature. It is composed of a cryogenic blower, thermal shroud, heater, cryogenic valves. This paper presents an overview of closed loop thermal control system's design parameter and test results for control parameter. A capacity of blower is calculated through energy balance equation and an advantage/disadvantage for a shroud material and a type was analysed. The thermal control system is controlled by a constant density of fluid in the system. A requested performance of closed loop thermal control system was verified by measuring a homogeneity and stability of shroud through control parameter such as density and RPM of blower.

OBSERVATIONS AND SPECTRAL ANALYSES OF SOLAR FLARES

  • DING M. D.
    • Journal of The Korean Astronomical Society
    • /
    • v.36 no.spc1
    • /
    • pp.49-54
    • /
    • 2003
  • We introduce the two-dimensional spectral observations of solar flares using the Solar Tower Tele-scope of Nanjing University, China. In particular, we introduce three typical events and the methods used to analyze the data. (1) The flare of November 11, 1998, which is a limb flare. We derive the temperature and density within the flaring loop using non-LTE calculations. The results show that the loop top may be hotter and denser than other parts of the loop, which may be a result of magnetic reconnect ion above the loop. (2) The flare of March 10, 2001, which is a white-light flare that shows an emission enhancement at the near infrared continuum. We propose a model of non-thermal electron beam heating plus backwarming to interpret the observations. (3) The flare of September 29, 2002, which shows unusual line asymmetries at one flare kernel. The line asymmetries are caused by an upward moving plasma that is accelerated and heated during the flare development.

A Model Calculation of Solar Microwave Burst Structure

  • Choi, Yong-Seok
    • Bulletin of the Korean Space Science Society
    • /
    • 1995.04a
    • /
    • pp.21-21
    • /
    • 1995
  • The structures of 17GHz microwave burst for bipolar sunspots have investigated. which included the effects of the projected shapes of radio sources as they traverse across the solar disk using a magnetic loop employing a model of solenoid coils. An ensemble of high-energy electrons confined in the loop be assumed. The projected brightnesls distributions of gyrosynchrotron emission in x- and o-modes are computed and converted into total intensity and circular polarization difference at 17GHz for various heliocentric distances using numerical integration of the transfer equation along the line of sight. The results of computations at 17GHz for optical thin case will be presented. and the effects of the orientation of the loop will be discussed in detail, as well as the effect of size, position, Structure, and polarization of the emission. Also the results of the various physical P8lrameters such as the strength of magnetic field. high and low energy cut-off of accelerated electrons. spectral index and density of electrons will be preslmted. After comparing the results of model calculation with observations. we found that the observations can be well explained in terms of a loop model and its projection effect.effect.

  • PDF

MATHEMATICAL PHASE NOISE MODEL FOR A PHASE-LOCKED-LOOP

  • Limkumnerd, Sethapong;Eungdamrong, Duangrat
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.233-236
    • /
    • 2005
  • Phase noise in a phase-locked-loop (PLL) is unwanted and unavoidable. It is a main concern in oscillation system especially PLL. The phase noise is derived in term of power spectrum density by using a reliable phase noise model. There are four noise sources being considered in this paper, which are generated by reference oscillator, voltage controlled oscillator, filter, and main divider. The major concern for this paper is the noise from the filter. Two types of second order low pass filter are used in the PLL system. Applying the mathematical phase noise model, the output noises are compared. The total noise from the passive filter is lower than the active filter at the offset frequency range between 1 Hz to 33 kHz.

  • PDF

Investigation on Optimum Plasma Production Condition of a Magnetic Neutral Loop Discharge System (자기중성선방전 시스템의 최적 플라즈마 생성조건에 관한 고찰)

  • Sung, Youl-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2236-2241
    • /
    • 2009
  • In this study, the electron behavior was investigated numerically in order to obtain guidelines for design and operation of a new plasma source by a magnetic neutral loop discharge (NLD). The optimum plasma production was investigated by using a 3-dimensional simulation model which enables the electron behavior calculation from source region to downstream region. The results showed that the high-density plasma produced around the magnetic neutral loop (NL) is transferred from the NL region to the downstream region along magnetic force lines. Also the avaraged electron energy is increased with the normalized RF electric field (F), which can be used to characterize the plasma production efficiency of NLD system. Considering the relation between F and plasma production, in-depth plasma control can be achieved at a given specific process condition.

신규 가입자망 기술의 경제성 평가를 위한 망 구조모형과 그 응용

  • 류태규;이정동;김태유
    • Proceedings of the Korea Technology Innovation Society Conference
    • /
    • 2000.11a
    • /
    • pp.45-67
    • /
    • 2000
  • Broadband access technologies plays an important role in the national information infrastructure. In the evolution path of the information infrastructure, the relative economics of alternative access technology is the most critical determining factor. In this paper, we discuss the economics of local loop access technologies of existing technologies, such as, ADSL, HFC, and new PLC. To do this, we suggest appropriate configuration of access network system and its associated numerical equations. To modelize access network system and drive the numerical equations, we consider the DS (Double Star) and the T&B (Tree & Brench) architecture and analyse the adequate block diagram of each access system for each technology We introduce the density of subscriber as a key variable and the equation of allocating optimal number of cell in a service area. We analyze the relative economics of local loop architecture in two different situations, that is, urban and rural. From the empirical implementation, we found that for the case of urban area, where the cost of cable and infrastructure is not necessary, there is not much difference in the cost per one subscriber. However, for the case of rural region, we found that there is remarkable difference in the cost per one subscriber among technologies. Therefore we conclude that the economics of local loop architecture is depend on the density of subscriber and existing network infrastructures. we hope that this paper contribute to the optimal technology selection of consmer, technology Providers, and government.

  • PDF

Effects of particle size and density on solid recycle characteristics of Loop-seal in a Circulating Fluidized Bed (순환유동층내 Loop-seal 에서의 고체재순환에 대한 입자크기 및 밀도의 영향)

  • 김성원;안정렬;김상돈
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1999.11a
    • /
    • pp.31-34
    • /
    • 1999
  • 기-고체간의 접촉효율이 높고, 층 내 전체에 걸쳐서 균일한 기-고의 접촉을 갖는 등 많은 장점이 있어 석탄연소로, 촉매반응기와 같은 여러 기-고 반응기에 적용이 확대되고 있는 순환유동층은 높은 유속에서 조업되므로 상승관내 고체입자들은 즉시 비산하게 된다. 따라서, 원활한 반응에 필요한 상승관내 적절한 고체체류량 유지를 위해 고체입자들 대부분은 싸이클론에서 포집 되어 고체재순환부에 의하여 상승관내로 재주입 된다.(중략)