• 제목/요약/키워드: Loop Closure

검색결과 40건 처리시간 0.025초

직선기반 SLAM에서의 루프결합 (Loop Closure in a Line-based SLAM)

  • 장국현;서일홍
    • 로봇학회논문지
    • /
    • 제7권2호
    • /
    • pp.120-128
    • /
    • 2012
  • The loop closure problem is one of the most challenging issues in the vision-based simultaneous localization and mapping community. It requires the robot to recognize a previously visited place from current camera measurements. While the loop closure often relies on visual bag-of-words based on point features in the previous works, however, in this paper we propose a line-based method to solve the loop closure in the corridor environments. We used both the floor line and the anchored vanishing point as the loop closing feature, and a two-step loop closure algorithm was devised to detect a known place and perform the global pose correction. We propose an anchored vanishing point as a novel loop closure feature, as it includes position information and represents the vanishing points in bi-direction. In our system, the accumulated heading error is reduced using an observation of a previously registered anchored vanishing points firstly, and the observation of known floor lines allows for further pose correction. Experimental results show that our method is very efficient in a structured indoor environment as a suitable loop closure solution.

Classification of Speleology in Wikipedia

  • Oh, Jong-Woo
    • 동굴
    • /
    • 제82호
    • /
    • pp.17-25
    • /
    • 2007
  • The use of a low-frequency cave radio can also verify survey accuracy. A receiving unit on the surface can pinpoint the depth and location of a transmitter in a cave passage by measurement of the geometry of its radio waves. A survey over the surface from the receiver back to the cave entrance forms an artificial loop with the underground survey, whose loop-closure error can then be determined. In the past, caves were reluctant to redraw complex cave maps after detecting survey errors. Today, computer cartography can automatically redraw cave maps after data has been corrected.

VILODE : 키 프레임 영상과 시각 단어들을 이용한 실시간 시각 루프 결합 탐지기 (VILODE : A Real-Time Visual Loop Closure Detector Using Key Frames and Bag of Words)

  • 김혜숙;김인철
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제4권5호
    • /
    • pp.225-230
    • /
    • 2015
  • 본 논문에서는 키 프레임 영상과 SURF 특징점 기반의 시각 단어들을 이용한 효과적인 실시간 시각 루프 결합 탐지기 VILODE를 제안한다. 시각 루프 결합 탐지기는 과거에 지나온 위치들 중 하나를 다시 재방문하였는지를 판단하기 위해, 새로운 입력 영상을 이미 지나온 위치들에서 수집한 과거 영상들과 모두 비교해보아야 한다. 따라서 새로운 위치나 장소를 방문할수록 비교 대상 영상들이 계속해서 증가하기 때문에, 일반적으로 루프 결합 탐지기는 실시간 제약과 높은 탐지 정확도를 동시에 만족하기 어렵다. 이러한 문제점을 극복하기 위해, 본 시스템에서는 입력 영상들 중에서 의미 있는 것들만을 선택해 이들만을 비교하는 효과적인 키 프레임 선택 방법을 채택하였다. 따라서 루프 탐지에 필요한 영상 비교를 대폭 줄일 수 있다. 또한 본 시스템에서는 루프 결합 탐지의 정확도와 효율성을 높이기 위해, 키 프레임 영상들을 시각 단어들로 표현하고, DBoW 데이터베이스 시스템을 이용해 키 프레임 영상들에 대한 색인을 구성하였다. TUM 대학의 벤치마크 데이터들을 이용한 실험을 통해, 본 논문에서 제안한 시각 루프 결합 탐지기의 높은 성능을 확인할 수 있었다.

Conformational Sampling of Flexible Ligand-binding Protein Loops

  • Lee, Gyu-Rie;Shin, Woong-Hee;Park, Hahn-Beom;Shin, Seok-Min;Seok, Cha-Ok
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권3호
    • /
    • pp.770-774
    • /
    • 2012
  • Protein loops are often involved in diverse biological functions, and some functional loops show conformational changes upon ligand binding. Since this conformational change is directly related to ligand binding pose and protein function, there have been numerous attempts to predict this change accurately. In this study, we show that it is plausible to obtain meaningful ensembles of loop conformations for flexible, ligand-binding protein loops efficiently by applying a loop modeling method. The loop modeling method employs triaxial loop closure algorithm for trial conformation generation and conformational space annealing for global energy optimization. When loop modeling was performed on the framework of ligand-free structure, loop structures within $3\AA$ RMSD from the crystal loop structure for the ligand-bound state were sampled in 4 out of 6 cases. This result is encouraging considering that no information on the ligand-bound state was used during the loop modeling process. We therefore expect that the present loop modeling method will be useful for future developments of flexible protein-ligand docking methods.

상악전치 후방 견인시 견인 loop후방에 부여한 gable bend 양에 따른 치아이동 양상에 관한 연구 (A study on the effect of the magnitude of the gable bends on the tooth movement pattern during on-masse space closure in the maxillary dentition)

  • 전윤식;노준;정상혁;김희정
    • 대한치과교정학회지
    • /
    • 제34권1호
    • /
    • pp.33-45
    • /
    • 2004
  • 제 1소구치가 발치된 증례에서 bull loop를 견치 직후방에 제작한 후 gable bend를 어느 정도 부여할 때 전치부의 효과적인 치축조절과 후방 이동량을 극대화 할 수 있는지를 입체적으로 확인하는 것이 본 연구의 목적이다. 제 1소구치가 제거된 상악우측 인공 치조골부에 중절치부터 제 2대구치까지 실험용 치아들을 식립하였다. 그 후 bull-loop가 형성된 반쪽 호선에 $10^{\circ},\;20^{\circ},\;30^{\circ}$의 gable bend를 부여한 후 3전치를 후방 견인하여 발치공간을 폐쇄시켰고 이러한 실험과정을 각 군마다 3회씩 반복 실험하였다. 발치공간이 폐쇄된 후 실험전, 후의 교합방사선 사진상에 촬영된 전치부와 구치부의 시상면과 교합면 상에서의 각 군별 치아이동 양상을 일요인 분산분석(ANOVA)과 Scheffe 검정으로 평가한 결과 아래와 같은 결론을 얻었다. 1. Gable bend의 양이 증가할수록 전치부의 치축은 치체이동 양상을 보였으며 후방 이동량도 증가하였다. 2. Gablebend의 양이 증가할수록 구치부의 전방 이동량은 감소하였으나 수직적 압하량 및 협측 이동량은 증가하였다(p<0.001). 3. 발치공간에 인접한 견치의 원심회전과 제 2소구치의 근심회전에 의해 악궁의 조화가 이루어졌다(p<0.001).

극소 저출생 체중아에서 조성한 장루의 복원 경험 (Experience with Enterostomy Closure in Very Low Birth Weight Infants)

  • 신희철;문석배;이성철;정성은;박귀원
    • Advances in pediatric surgery
    • /
    • 제15권1호
    • /
    • pp.18-26
    • /
    • 2009
  • The survival of Very Low Birth Weight (VLBW) infants has been improved with the advancement of neonatal intensive care. However, the incidence of accompanying gastrointestinal complications such as necrotizing enterocolitis has also been increasing. In intestinal perforation of the newborn, enterostomy with or without intestinal resection is a common practice, but there is no clear indication when to close the enterostomy. To determine the proper timing of enterostomy closure, the medical records of 12 VLBW infants who underwent enterostomy due to intestinal perforation between Jan. 2004 and Jul. 2007 were reviewed retrospectively. Enterostomy was closed when patients were weaned from ventilator, incubator-out and gaining adequate body weight. Pre-operative distal loop contrast radiographs were obtained to confirm the distal passage and complete removal of the contrast media within 24-hours. Until patients reached oral intake, all patients received central-alimentation. The mean gestational age of patients was $26^{+2}$ wks ($24^{+1}{\sim}33^{+0}$ wks) and the mean birth weight was 827 g (490~1450 g). The mean age and the mean body weight at the time of enterostomy formation were 15days (6~38 days) and 888 g (590~1870 g). The mean body weight gain was 18 g/day (14~25 g/day) with enterostomy. Enterostomy closure was performed on the average of 90days (30~123 days) after enterostomy formation. The mean age and the mean body weight were 105 days (43~136 days) and 2487 g (2290~2970 g) at the time of enterostomy closure. The mean body weight gain was 22 g/day after enterostomy closure. Major complications were not observed. In conclusion, the growth in VLBW infants having enterostomy was possible while supporting nutrition with central-alimentation and the enterostomy can be closed safely when the patient's body weights is more than 2.3 kg.

  • PDF

인공판막 후부 공동부가 판막의 수력학적 성능에 미치는 영향 (The Effects of Distal Sinus on the Hydrodynamic Performance of the Prosthetic Heart Valves)

  • 이계한;서종천
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권3호
    • /
    • pp.297-303
    • /
    • 1998
  • 판막 후부의 공동부는 판막의 닫힘 거동과 판막 주위의 혈류 유동장을 변화시켜 인공 판막의 수력학적 성능에 영향을 미칠 수 있다. 계식 이엽 판막(SJMV), 폴리머 단엽 판막(MLPV), 폴리머 삼엽 판막(FTPV)을 판막 후부에 공동부가 있는 시험부와 공동부가 없는 직관형 시험부에 설치하여 모의 순환 장치에서 판막의 수력학적 성능을 평가하였다. 판막의 누수량은 공동부가 있는 시험부에서 약간 작았고, 수축기 평균 압력강하는 크게 나타났으나 통계적으로는 큰 차이가 없었다. 따라서 판막 후부의 공동부는 판막의 수력학적 성능에 큰 영향을 나타내지 않았다. 유량 파형의 해석 결과 판막 후부 공동부는 MLPV에서는 판막의 닫힘에 큰 영향을 주지 않았으나, SJMV에서는 판막의 닫힘이 일찍 시작하게 하였고 이 영향은 FTPV에서 더욱 크게 나타났다. FTPV는 공동부가 있는 시험부에서 역류 최대 유량이 감소하였으므로 판막 후두에 공동부는 판막의 급격한 닫힘에 의한 역류 제트의 발생을 감소시키리라 기대된다.

  • PDF

En-masse 견인에 의한 발치공간 폐쇄 후 상악치열의 이동양상 -제1소구치 및 제2소구치 발치 비교 (Spatial changes of the upper dentition following en-masse space closure: A comparison between first and second premolar extraction)

  • 김희정;전윤식;정상혁
    • 대한치과교정학회지
    • /
    • 제35권5호
    • /
    • pp.371-380
    • /
    • 2005
  • 제1소구치 또는 제2소구치 발치 후 발치공간 폐쇄 시 치아이동의 양상 즉, 치아이동방향과 이동량을 구명하는 것이 본 연구의 목적이었다. 상악 우측 인공 치조골부에 제1소구치 또는 제2소구치를 제외한 중절치부터 제2대구치 까지 실험용 치아들을 식립하고 bull loop이 형성된 반쪽 호선에 15도의 gable bend를 부여한 후 전치부를 후방견인하여 발츠공간을 폐쇄시켰다. 실험 전후에 교합면 방사선사진과 시상면 방사선사진을 촬영하고 인공치조골부 하단에 식립된 기준표지점에 중첩하여 이동방향 및 이동량을 계측하였다. 그 결과 제2소구치 발치군의 전치부후방이동량이 제1소구치 발치군에 비해 더 적었으며 구치부의 고정원 소실 및 고정원의 근심설측회전량은 제2소구치 발치군에서 더 크게 나타났다.

대학종합병원 전공의 가운 개발에 관한 연구 -수납 및 활동성을 중심으로- (A Study on the Development of the Medical Gowns for Interns and Residents at a University Hospital -Focus on Pockets and Movement Adaptability-)

  • 윤희영;최혜선
    • 한국의류학회지
    • /
    • 제34권5호
    • /
    • pp.819-830
    • /
    • 2010
  • This study proposes medical gowns for interns and residents that address the functions of utility and activity. Based on the questionnaires, the prototype focused on the pockets for practical use and movement adaptability. Functional pockets were made by increasing pocket sizes and separating pockets with sections according to use. An inside pocket and a loop for an identification tag was placed on the chest pocket and the side seam pocket were oblique lined. To resolve horizontal stress on the back of the gown,6 cm action pleats were added at both ends of the bladebone. The elbow area was tucked up to improve the workplace activities. To reduce hamper on the gown hemline, slits were added along the gown side seam. The front button was changed into an inside button closure. The cuffs, belt, and back waist belt were removed due to occupational cases of inconvenience. The length of the sleeves was adjusted with belts to improve the movement of the arms. In accordance with design preference, the gown was designed to be knee-length with wrist length sleeves. Blue colored (2.5PB 3/12: by Munsell) material was inserted to reduce the contamination on the neck, cuffs, front closure, and hemline area. The planning cloth of the experimental gown was designed to improve activity function, cleaning, and comfort from light materials. The field test (with 30 doctors at university hospitals and the objective assessment with 9 subject groups)were done by the valuation between the existing gown and the prototype. The results showed that the prototype had to be modified by decreasing the pocket size, expanding the usage of the penholder, and simplify front pockets in order to maintain unity. The loop for the identification tag, inside pocket, and the blue colored material had to be removed. The front closure of the gown had to return to its original state.