• 제목/요약/키워드: Longitudinal resistance

검색결과 235건 처리시간 0.03초

Floating Zone법에 의한 Rutile($TiO_2$)단결정 육성 (Growth of Rutile Single Crystal by Floating Zone Method)

  • 신재혁;강승민;오근호
    • 한국세라믹학회지
    • /
    • 제27권8호
    • /
    • pp.1050-1054
    • /
    • 1990
  • Rutile(TiO2) single crystals were grown by FZ method. Feed rod was sintered in the longitudinal tube-shaped furnace at 135$0^{\circ}C$ and optimum growth condition was growth rate 5-8mm/hr, rotation rate 30-40rpm. When crystal was growing, atomosphere was oxidized condition, and grown single crystal was annealed at 110$0^{\circ}C$. The rutile single crystals were oriented to [001] direction and color change of single crystals were related to atmosphere, and difference of electric conductivity and resistance was due to the fact above.

  • PDF

An association of urinary sodium-potassium ratio with insulin resistance among Korean adults

  • Park, Yeong Mi;Kwock, Chang Keun;Park, Seyeon;Eicher-Miller, Heather A.;Yang, Yoon Jung
    • Nutrition Research and Practice
    • /
    • 제12권5호
    • /
    • pp.443-448
    • /
    • 2018
  • BACKGROUND/OBJECTIVES: This study was conducted to investigate the effects of sodium-potassium ratio on insulin resistance and sensitivity in Korean adults. SUBJECTS/METHODS: Subjects were 3,722 adults (1,632 men and 2,090 women) aged 40-69 years participating in the Korean genome and epidemiology study_Ansan and Ansung study. Insulin resistance was assessed using homeostasis model assessment of insulin resistance (HoMA-IR) and fasting insulin, and insulin sensitivity was assessed by using the quantitative insulin sensitivity check index (QUICKI). The 24-h urinary sodium and potassium excretion were estimated from spot urinary samples using the Tanaka formula. The generalized linear model was applied to determine the association between urinary sodium-potassium ratio and insulin resistance. RESULTS: HoMA-IR (P-value = 0.029, P-trend = 0.008) and fasting insulin (P-value = 0.017, P-trend = 0.005) levels were positively associated with 24-h estimated urinary sodium-potassium ratio in the multivariable model. QUICKI was inversely associated with 24-h estimated urinary sodium-potassium ratio in all models (P-value = 0.0002, P-trend < 0.0001 in the multivariate model). CONCLUSION: The present study suggests that high sodium-potassium ratio is related to high insulin resistance and low insulin sensitivity. Decreasing sodium intake and increasing potassium intake are important for maintaining insulin sensitivity. Further studies are needed to confirm these findings in longitudinal studies.

소형연안객선(小型沿岸客船)의 Trim변화(變化)가 저항(抵抗)에 미치는 영향(影響) (A Study on the Effect of Trim on the Resistance in a Small Coastwise Passenger Boat)

  • 황종흘;배광준
    • 대한조선학회지
    • /
    • 제4권1호
    • /
    • pp.49-54
    • /
    • 1967
  • The authors considered the effects of trim in the small coastal passenger boat upon resistance in this paper. Any change of trim no matter how small, necessarily produces some effect upon resistance. The relations between the resistance coefficients and trim were investigated through the towing test of the Model $MCI-P_1-65$, Korean Standardized Ship, GT 70 tons passenger boat in the gravitational tank. The Lines of the Model are given in Fig. 1. Principal dimensions and other characteristics vary with the trim in general. Those values varied with the trim for $MCI-P_1-65$ are tabulated in table 1. The resistance was measured at five conditions such as even keel, 0.0273L, (original designed trim) 0.0473L, 0.0663L, 0.0873L trim by the stern, fixing the displacement corresponding to the designed load water line. Model was made of wood in length of 3.5 feet coated with varnish, and without appendages. As the artificial turbulent stimulator, the sand strip method was used. The results of model towing tests, correcting to water temperature of $70^{\circ}F$, were expanded to full scale using the Schoenherr's friction formula and surface roughness allowance coefficient of 0.0004. The authors point out, the following results. 1) Optimum trim which gives the minimum resistance exists for every speed at constant displacement and each comes to the same value. For $MCI-P_1-65$ optimum trim is 0.0673L trim by the stern(Fig.4-The cross curves of the resistancecoefficients). 2) At constant displacement, when LCB(longitudinal position of center of buoyancy) varies with the trim, there exists optimum value of LCB which gives minimum resistance for every speed and each comes to the same value. For $MCI-P_1-65$ optimum position of LCB is 8%L aft from midship section (Fig.6).

  • PDF

Patch load resistance of longitudinally stiffened webs: Modeling via support vector machines

  • Kurtoglu, Ahmet Emin
    • Steel and Composite Structures
    • /
    • 제29권3호
    • /
    • pp.309-318
    • /
    • 2018
  • Steel girders are the structural members often used for passing long spans. Mostly being subjected to patch loading, or concentrated loading, steel girders are likely to face sudden deformation or damage e.g., web breathing. Horizontal or vertical stiffeners are employed to overcome this phenomenon. This study aims at assessing the feasibility of a machine learning method, namely the support vector machines (SVM) in predicting the patch loading resistance of longitudinally stiffened webs. A database consisting of 162 test data is utilized to develop SVM models and the model with best performance is selected for further inspection. Existing formulations proposed by other researchers are also investigated for comparison. BS5400 and other existing models (model I, model II and model III) appear to yield underestimated predictions with a large scatter; i.e., mean experimental-to-predicted ratios of 1.517, 1.092, 1.155 and 1.256, respectively; whereas the selected SVM model has high prediction accuracy with significantly less scatter. Robust nature and accurate predictions of SVM confirms its feasibility of potential use in solving complex engineering problems.

크로질화박막 스트레인 게이지의 특성 (Characteristics of Chromiun Nitride Thin-film Strain Guges)

  • 정귀상;김길중
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 전자세라믹스 센서 및 박막재료 반도체재료 일렉트렛트 및 응용기술
    • /
    • pp.134-138
    • /
    • 2000
  • The physical, electrical and piezoresitive characteristics of CrN(chromiun nitride) thin-films on silicon substrates have been investigated for use as strain gauges. The thin-film depositions have been carried out by DC reactive magnetron sputtering in an argon-nitrogen atmosphere(Ar-(5~25 %)$N_2$). The deposited CrN thin-films with thickness of $3500{\AA}$nd annealing conditions($300^{\circ}C$, 48 hr) in Ar-10 % $N_2$ deposition atmosphere have been selected as the ideal piezoresistive material for the strain gauges. Under optimum conditions, the CrN thin-films for the strain gauges is obtained a high electrical resistivity, $\rho=1147.65\;{\mu}{\Omega}cm$, a low temperature coefficient of resistance, TCR=-186 ppm/$^{\circ}C$ and a high temporal stability with a good longitudinal gauge factor, GF=11.17.

  • PDF

철근콘크리트 보의 전단마찰모델 (Shear-Friction Truss Model for Reinforced Concrete Beams)

  • 홍성걸;하태훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.873-878
    • /
    • 2001
  • This Paper Presents a new model, called the “shear-friction truss model,” for slender reinforced concrete beams to derive a clear and simple equation for their ultimate shear strength. In this model, a portion of the shear strength is provided by shear reinforcement as in the traditional truss model, and the remainder by the shear-friction mechanism. Friction resistance is derived considering both geometrical configuration of the rough crack surface and material Properties. The inclined angle of diagonal strut in the traditional truss model is modified to satisfy the state of balanced failure, when both stirrups and longitudinal reinforcement yield simultaneously. The vertical component of friction resistance is added to the modified truss model to form the shear-friction truss model. Test results from published literatures are used to find the effective coefficient of concrete strength in resisting shear on inclined crack surfaces.

  • PDF

고온 스트레인 게이지용 질화탄탈박막의 제작 (Fabrication of Tantalum Nitride Thin-Film as High-temperature Strain Gauges)

  • 최성규;나경일;남효덕;정귀상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.1022-1025
    • /
    • 2001
  • This paper presents the characteristics of TaN thin-film as high-temperature strain gauges, which were deposited on Si substrate by DC reactive magnetron sputtering in an argon-nitrogen atmosphere(Ar-(4∼20%)N$_2$). The electrical and mechanical characteristics of these films investigated with the thickness range 1650∼1870${\AA}$ and room temperature resistivities in the range 178.3 ${\mu}$$\Omega$cm to 3175.7 ${\mu}$$\Omega$cm. The TaN thin-film strain gauge deposited in Ar-(20%)N$_2$atmosphere is obtained a temperature coefficient of resistance(TCR), 0∼-1357 ppm/$^{\circ}C$ in the temperature range 25∼275$^{\circ}C$ and a high temporal stability with a longitudinal gauge factor, 2.92∼3.47. Because of their high resistivity, low TCR and linear gauge factor, these cermet thin-film may allow high-temperature strain gauges miniaturization.

  • PDF

슬래브-기둥 접합부의 내진성능을 위한 래티스 전단보강 (Lattice Shear Reinforcement for Earthquake-Resistance of Slab-Column Connection.)

  • 김유니;박홍근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.26-29
    • /
    • 2006
  • A flat plate-column connection is susceptible to brittle punching shear failure, which may result in the necessity of shear reinforcement. In present study, experimental tests were performed to study the capacity of slab-column connections strengthened with lattice, stud rail, shear band and stirrup under gravity and cyclic lateral load. Among them, the capacity of the specimens with lattice are superior to the others due to the truss action of the lattice bars and dowel action of the longitudinal bars as well as the shear resistance of the web re-bar. On the other hand, the strengths of the specimens with stud rail, shear band and stirrup are lower than the estimated strength by the ACI, therefore design formulas of the ACI are needed to revise.

  • PDF

고감도 박막형 스트레인 게이지의 제작 (Fabrication of High-sensitivity Thin-film Type Strain-guges)

  • 정귀상;서정환
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 영호남학술대회 논문집
    • /
    • pp.135-141
    • /
    • 2000
  • The physical, electrical and piezoresitive characteristics of CrN(chromiun nitride) thin-films on silicon substrates have been investigated for use as strain gauges. The thin-film depositions have been carried out by OC reactive magnetron sputtering in an argon-nitrogen atmosphere(Ar-(5~25 %)$N_2$). The deposited CrN thin-films with thickness of $3500{\AA}$ and annealing conditions($300^{\circ}C$, 48 hr) in Ar-10 % $N_2$ deposition atmosphere have been selected as the ideal piezoresistive material for the strain gauges. Under optimum conditions, the CrN thin-films for the strain gauges is obtained a high electrical resistivity, $\rho=1147.65\;{\mu}{\Omega}cm$, a low temperature coefficient of resistance, TCR=-186 ppm/$^{\circ}C$ and a high temporal stability with a good longitudinal gauge factor, GF=11.17.

  • PDF

토션 바 스프링을 적용한 일체형 도어체커 개폐력 해석 (Door Effort Analysis for Door Checker of Integrated Type with Torsion Bar Spring)

  • 윤상민;강성종
    • 한국기계가공학회지
    • /
    • 제11권3호
    • /
    • pp.86-91
    • /
    • 2012
  • Door effort was calculated for a new door checker with torsion bar spring and integrated checker case by FE analysis. A hybrid checker arm which has peaks and valleys only on the upper surface was adopted to reduce noise in operation and make operation with more distinctive steps. The checker arm was modeled using shell elements to estimate both the longitudinal and the lateral resistance force by checker arm. By combining the checker arm resistance force obtained from analysis and the door self-closing force by the theoretical calculation, door effort was predicted to show the good correlation with test results. In addition the unrolling effect of roller model was investigated and a new roller type for more smooth rolling was studied.