• Title/Summary/Keyword: Longitudinal Discharge

Search Result 59, Processing Time 0.026 seconds

Operational Characteristics of a Nitrogen Laser with Sliding Discharge and Longitudinal Excitation (종방향 여기 방식과 표면방전에 의한 질소레이저의 동작 특성)

  • Lee, Bong-Yeon
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.5
    • /
    • pp.450-455
    • /
    • 2005
  • We have studied on operational characteristics of the nitrogen laser with sliding discharge and longitudinal excitation. We could observe radiation of nitrogen laser excited by a sliding discharge along the surface of a dielectric. The shape of the beam was a ring type which had 2 mm or 4mm in diameter depending on the sliding discharge tube shape. In this experiment, We show the possibilities to make other shapes of laser beam, for example, rectangle, ellipse, and to excite another gas laser system like an excimer laser.

Properties of Longitudinal & Transverse Discharge in a Tubular Fluorescent Lamp (직관형 형광램프의 종단방전과 횡단방전의 특성)

  • Chung, J.Y.;Kim, J.H.;Jeong, J.M.;Jin, D.J.;Kim, H.C.;Bong, J.H.;Hwang, H.C.;Lee, M.S.;Koo, J.H.;Cho, G.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.4
    • /
    • pp.322-330
    • /
    • 2008
  • The properties of discharge, luminance, and spectroscopy are investigated in a longitudinal and transverse discharge fluorescent lamps with tube of outer diameter 4 mm. The sample lamps are prepared to be three kinds of gas composition such as mercury lamps of Ne(95%)+Ar(5%)+Hg(2 mg), the mercury-free lamps of Xe 100% and Ne+Xe(4%). The gas pressure is in the range of $5{\sim}300\;Torr$. In the mercury lamps, the longitudinal discharge having a positive column is high in luminance and efficiency, while the transverse discharge is no luminance at all. In the Xe-lamps, the transverse discharge shows relatively good in efficiency as compared with the longitudinal discharge which has a high discharge voltage and a low luminance and efficiency. In the transverse discharge of relatively high efficiency, a pure Xe(100%) gas discharge has a higher efficiency than the mixture gas of Ne+Xe(4%). Through these experiments, the properties of mercury and xenon lamps are verified. In the mercury lamps, the longitudinal discharge of tubular fluorescent lamps is high in luminance and efficiency, while the transverse discharge of flat panel fluorescent lamps are low in luminance efficiency. In the mercury-free lamps, the flat fluorescent lamps of transverse discharge having a high pressure ${\sim}100\;Torr$ with the pure Xe-gas are verified to be suggestable.

Relationship between Readiness for Hospital Discharge and Self-care of Liver Transplant Recipients: A Single-center Prospective Study (간이식 환자의 퇴원 준비도와 자가간호와의 관계: 종단적 연구)

  • Park, SunBok;Choi, JiYeon;Joo, DongJin;Chu, SangHui
    • Journal of Korean Biological Nursing Science
    • /
    • v.24 no.4
    • /
    • pp.243-252
    • /
    • 2022
  • Purpose: The purpose of this longitudinal study was to identify the relationship between the readiness for hospital discharge and self-care changes in an early stage of liver transplantation after discharge. Methods: Data of 75 liver transplant recipients within one year of surgery from a transplantation center from May 2019 to May 2020 were collected for this study. Their readiness for discharge was measured before discharge. Self-care after liver transplantation was evaluated at one week, one month, and three months of discharge at outpatient visits. Linear mixed model was used to evaluate the statistical relationship. Results: The readiness for hospital discharge was significantly higher when the caregiver was a spouse (p=.027), with fewer post-transplantation days (p=.027), absence of acute rejection (p=.004), or high self-efficacy (p<.001). As a result of the linear mixed model analysis, the higher the discharge readiness score, the higher the self-care score (β=0.29, p<.001). However, after three months, their self-care had decreased regardless of their level of readiness for hospital discharge compared to one week after discharge. Conclusion: Improving the readiness before discharge is essential to enhance self-care. Also, active intervention at 3 months of discharge should be performed to check and promote their long-term self-care.

The Effect of Rotation of Discharge Hole on the Discharge Coefficient and Pressure Coefficient (송출공의 회전이 송출계수와 압력계수에 미치는 영향)

  • Ha, Kyoung-Pyo;Ku, Nam-Hee;Kauh, S.Ken
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.7
    • /
    • pp.948-955
    • /
    • 2003
  • Pressure coefficient in rotating discharge hole was measured to gain insight into the influence of rotation to the discharge characteristics of rotating discharge hole. Pressure measurements were done by the telemetry system that had been developed by the authors. The telemetry system measures static pressure using piezoresistive pressure sensors. Pressure coefficients in rotating discharge hole were measured in longitudinal direction and circumferential direction with various rotating speed and 3 pressure ratios. From the results, the pressure coefficient, and therefore the discharge coefficient, is known to decrease with the increase of Ro number owing to the increase of flow approaching angle to the discharge hole inlet. However, there exists critical Ro number where the decrease rate of discharge coefficient with the increase of Ro number changes abruptly; flow separation occurs from the discharge hole exit at this critical Ro number. Critical Ro number increases with the increase of length-to-diameter ratio, but the increase is small where the length-to-diameter ratio is higher than 3. The decrease rate of discharge coefficient with the increase of Ro number depends on the pressure recovery at the discharge hole, and the rate is different from each length-to-diameter ratio; it has tendency that the short discharge hole shows higher decrease rate of discharge coefficient.

The Study of Jet Fan Control Logic for Longitudinal Ventilation in Road Tunnel (젯트팬 종류식 터널의 퍼지응용 제어로직에 관한 연구)

  • 유지오;남창호;신현준
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.8
    • /
    • pp.763-770
    • /
    • 2000
  • In tunnel ventilation, the Purpose of ventilation control is to keep the required pollution level with minimum consumption of energy But tunnel ventilation has large disturbances caused by discharge of pollutants, traffic forces especially strong for longitudinal ventilation. Hence in this paper, the tunnel ventilation control logic applying fuzzy control theories is proposed and the simulation program of tunnel ventilation control is developed. The characteristics of longitudinal ventilation with jet fans are estimated and the effect of the proposed tunnel ventilation control is verified by the simulation program.

  • PDF

Increase in Color Depth of Black Dyed PET Fabrics Treated by Sputter Etching (Sputter etching에 의한 PET직물의 심색성 향상)

  • Shim, Yu Bong;Lee, Mun Cheul
    • Textile Coloration and Finishing
    • /
    • v.9 no.1
    • /
    • pp.15-22
    • /
    • 1997
  • The alkali treated and black dyed PET fabrics were sputter etched under Ar gas atmosphere. The color depth of PET fabrics were increased with sputter etching time only under some limits of discharge power. And above that limits of discharge power the color depth of PET fabrics was decreased by increasing discharge power and treatment time. Minute cracks were made by sputter etching in the whole surface of fabrics to the direction of perpendicular to the longitudinal side of yarns. The fineness and density of minute crack were increased with lowering discharge power. And the size of crack was far smaller than that of microcrater which was obtained by alkali treatment. It is considered that the increase of color depth is related to the minute crack. The water permeation time of sputter etched fabrics was increased with increasing discharge power and treating time. The increase of color depth attained by sputter etching was fully kept through repeated laundering.

  • PDF

Analysis of Reduction Effect on Noise Discharge from Lightweight Soundproof Tunnels Installed with Lateral Sound-absorbing Panels (직각 흡음체 설치 경량방음터널의 토출소음 저감효과 분석)

  • Jeong, Young Do;Ahn, Dong-Wook;Noh, Myung-Hyun
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.7 no.1
    • /
    • pp.19-24
    • /
    • 2016
  • Most of the soundproof tunnels generate significant discharge noise through their inlets and outlets so that the length of the tunnel has been extended frequently than required to minimize the effect on such discharge noise. Thus, in this paper, we investigate reduction capability of discharge noise from the sound proof tunnel installed with lateral sound-absorbing panels on the partitioned truss members in the longitudinal direction of the tunnel. In conclusion, noise field analysis results shows that the sound proof tunnels with lateral sound-absorbing panels have an effect on discharge noise abatement and thereby tunnel's length reduction.

Measurement of Pressure Coefficient in Rotating Discharge Hole by Telemetric Method (무선계측기법을 이용한 회전 송출공의 압력계수 측정)

  • Ku, Nam-Hee;Kauh, Sang-Ken;Ha, Kyoung-Pyo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.9
    • /
    • pp.1248-1255
    • /
    • 2003
  • Pressure coefficient in a rotating discharge hole was measured to gain insight into the influence of rotation on the discharge characteristics of rotating discharge holes. Pressures inside the hole were measured by a telemetry system that had been developed by the authors. The telemetry system is characterized by the diversity of applicable sensor type. In the present study, the telemetry system was modified to measure static pressure using piezoresistive pressure sensors. The pressure sensor is affected by centrifugal force and change of orientation relative to the gravity. The orientation of sensor installation for minimum rotating effect and zero gravity effect was found out from the test. Pressure coefficients in a rotating discharge hole were measured in longitudinal direction as well as circumferential direction at various rotating speeds and three different pressure ratios. From the results, the behaviors of pressure coefficient that cannot be observed by a non-rotating setup were presented. It was also shown that the discharge characteristics of rotating discharge hole is much more influenced by the Rotation number irrespective of pressure ratio.

Numerical analysis of flow characteristics at the bifurcation channel by changing of discharge ratio using TELEMAC-2D (TELEMAC-2D를 적용한 개수로 분류부 유량비 변화에 의한 흐름특성 분석)

  • Jung, Daejin;Jang, Chang-Lae;Jung, Kwansue
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.1
    • /
    • pp.1-10
    • /
    • 2019
  • This study investigates the flow characteristics, such as velocity distributions, size and location of recirculation zone, longitudinal flow change rates, and bifurcation discharge ratio in the bifurcation channel by TELEMAC-2D, a 2D numerical model. The numerical model is validated by previous experimental results and the numerical results are in relatively good agreement with the experimental results, such as the water surface elevation and velocity distribution in the channels. As the inertial force and moment in the main channel decrease, the bifurcation discharge ratio increases, and the relative high velocity distribution becomes wider and the reverse velocity of the main stream decreases in the branch channel. As the bifurcation discharge ratio increases, the size of the recirculation zone in the branch channel decreases and it can be more clearly calculated by determining the point where the longitudinal froude number $Fr{\approx}0$ as well as drawing the distribution of the streamline distribution.

A 30 W Copper Vapor Laser Using a Vacuum Tube Based Pulse Generator (진공관 전원방식 30 W급 구리증기레이저)

  • 진정태;차병헌;김철중;이흥호
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.12
    • /
    • pp.568-572
    • /
    • 2003
  • A longitudinal discharge heated copper vapor laser with internal diameter 28 mm and discharge length 1.3 m has been constructed and tested. At the discharging voltage 15.2 kV, pulse repetition rate 10 kHz, buffer gas pressure 40 mbar, and internal temperature of the laser plasma tube $1520^{\circ}C$, it delivers more than 30 W average laser outputs.