• Title/Summary/Keyword: Long-term Air Monitoring

Search Result 90, Processing Time 0.029 seconds

Application of MODIS Satellite Observation Data for Air Quality Forecast (MODIS 인공위성 관측 자료를 이용한 대기질 예측 응용)

  • Lee, Kwon-Ho;Lee, Dong-Ha;Kim, Young-Joon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.6
    • /
    • pp.851-862
    • /
    • 2006
  • Satellites have been valuable tool for global/regional scale atmospheric environment monitoring as well as emission source detection. In this study, we present the results of application of satellite remote sensing data for air quality forecast in Seoul metropolitan area. AOT (Aerosol Optical Thickness) data from TERRA/MODIS (Moderate Resolution Imaging Spectre-radiometer) satellite were compared to ground based $PM_{10}$ mass concentrations, and used to estimate the possibility of the aerosol forecasting in Seoul metropolitan area. Although correlation coefficient (${\sim}0.37$) between MODIS AOT products and surface $PM_{10}$ concentration data was relatively low, there was good correlation between MODIS AOT and surface PM concentration under certain atmospheric conditions, which supports the feasibility of using the high-resolution MODIS AOT for air quality forecasting. The MODIS AOT data with trajectory forecasts also can provide information on aerosol concentration trend. The success rate of the 24 hour aerosol concentration trend forecast result was about 75% in this study. Finally, application of satellite remote sensing data with ground-based air quality observations could provide promising results for air quality monitoring and more exact trend forecast methodology by high resolution satellite data and verification with long term measurement dataset.

Spatial Distribution and Variation of Long-range Transboundary Air Pollutants Flux during 1997~2004 (장거리이동 대기오염물질 이동량의 공간적 분포와 변화 추이(1997~2004))

  • Han J. S.;Kim Y. M.;Ahn J. Y.;Kong B. J.;Choi J. S.;Lee S. U.;Lee S. J.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.1
    • /
    • pp.99-106
    • /
    • 2006
  • Aircraft measurements have been executed for the purpose of monitoring the long range transported air pollution and estimation of air pollutant in/out-flux over the Yellow sea. Total 74 missions of measurements have been done since 1997, mainly in spring and fall. The main study domain was over $124^{\circ}$E $/sim$ $124^{\circ}$E, $35^{\circ}$N $/sim$ $37^{\circ}$N below 3,000m. In long-term trends, mixing ratios of $SO_{2}$N were around 2 ppbv expect in summer ( < 1 ppbv). NOx exhibited 24 ppbv and have no clear annual trends over the Yellow Sea. The concentrations of 03 were 51, 58, 41 ppbv in spring, summer and fall-winter, respectively. Backward trajectory was performed for three days to investigate the source regions of the air mass. Six regions were divided around Korea peninsular centering at $36^{\circ}$N, $126^{\circ}$E. I, II, III, IV and V regions represents in sequence northeast China and Siberia, Sandong peninsula and Balhae gulf, Sanghi and southern China, the south Pacific included Jeju island and the East sea included Japan. L region correspond to the airmass from Korea peninsula. Influx of $SO_{2}$N was approximately five times higher than outflux in yearly flux variation and showed a decreasing long-term trend since 1998. NOx outflux was average 0.095 ton/km/hr and three times higher than $SO_{2}$ outflux. In/out flux of 03 showed even distribution in yearly basis except 2002 (influx 5.45 ton/km/hr). The transported amounts from I, II, III regions were much higher than those from other region. In seasonal flux variation, influx levels of gas phases were the lowest in summer and the levels gradually increased from fall toward spring. As a result, transport of pollutants begins from fall and prevails in winter and spring.

Estimation of the Characteristics of Delayed Failure and Long-term Strength of Granite by Brazilian Disc Test (압열인장시험을 이용한 화강암의 지연파괴특성 및 장기안정성 평가)

  • Jung, Yong-Bok;Cheon, Dae-Sung;Park, Eui-Seob;Park, Chan;Lee, Yun-Su;Park, Chul-Whan;Choi, Byung-Hee
    • Tunnel and Underground Space
    • /
    • v.24 no.1
    • /
    • pp.67-80
    • /
    • 2014
  • Long-term stability and delayed failure of granite were evaluated through the laboratory test based on Wilkins method and Brazilian disc test (BDT) which yields tensile strength, mode I fracture toughness and subcritical crack growth parameters. Then, the long-term strength of granite was estimated by using analytical models and long-term stability of compressed air-energy storage (CAES) pilot cavern pressurized up to 5 ~ 6 MPa was evaluated using numerical code, FRACOD with the determined subcritical crack growth parameters. The results of test and analyses showed that the subcritical crack growth index, n was determined as 29.39 and the inner pressure of 5 ~ 6 MPa had an insignificant effect on the long-term stability of pilot cavern. It was also found that the measurement and analysis of acoustic emission events can describe the accumulation of damage due to subcritical crack growth quantitatively. That is, AE monitoring can provide the current status of rock under loading if we make an identical installation condition in the field with that of the laboratory test.

Air Pollution by Airplane Engines (항공기 엔진에 의한 대기오염)

  • 김대식
    • Journal of the Korean Professional Engineers Association
    • /
    • v.32 no.5
    • /
    • pp.118-125
    • /
    • 1999
  • Air pollutant emissions from airplane engines are estimated about 2 to 4 % of mobile source of USA and European countries which is not a large portion of current air pollution. But the passengers and airfreights are continuously increasing 5 to 7% annually and potential demands of air transportation services come to present, it could effect air pollutant emissions of USA will increase within 15 years. In case of our country, there has been continuous increase of air transportation service due to considerable economic growth in recent years and increase of air pollutant emissions of major international airports has followed. Rapid increase of air transportation due to launching of Inchon International Airport could effect air pollution dominantly. By this circumstance environmental specialist as well as mass communication raised necessity of air pollutant emission regulation from airplane engines. It is estimated that air pollutant emissions from airplane engines in our country is 2.7% of automobile sources, 10,809 ton, which is the same level as USA and European countries. It is increased by 12,2% compared to air pollutant emissions during 1996 and it will be increased more than a half of current air pollutant emission within 15 years due to our country's economic condition. Therefore implementation of airplane engine emissions regulation as well as test standards and accumulation of technology about characteristics of airplane engine emission and reduction method are needed. And continuous estimation of air pollutant emission from airplane engines and monitoring of increment as well as development of countermeasures by long term are necessary.

  • PDF

Air Quality Monitoring in Daejeon City with Long-Term NO2 and SO2 Passive Diffusive Samplers (장기 NO2 및 SO2 Passive Diffusive Sampler(PDS)를 이용한 대전시 대기질 모니터링)

  • Yim, Bong-Been;Kim, Sun-Tae;Jung, Jae-Ho;Lee, Bum-Jin
    • Journal of Environmental Science International
    • /
    • v.16 no.2
    • /
    • pp.187-195
    • /
    • 2007
  • Long-term passive diffusive samplers(PDS) have been used to measure $NO_2\;and\;SO_2$ concentrations at 21 sampling sites in Daejeon, Korea during the period of January 2000 - December 2002. The spatial distributions of annual $NO_2\;and\;SO_2$ concentrations were mapped. Average annual $NO_2$ concentration over the sampling period was $28.5{\pm}12.5\;ppb$, ranging from 1.2 to 81.7 ppb. Average annual $SO_2$ concentration over the sampling period was $7.7{\pm}4.8\;ppb$, ranging from 0.6 to 26.8 ppb. On average, $NO_2$ concentration was approximately 5.8%(1.6 ppb) larger in 2002. $SO_2$ concentration was decreased by 13%(1.1 ppb) during the sampling period. The seasonal variation of $NO_2\;and\;SO_2$ concentration was observed with a tendency to be higher in fall and winter. $NO_2\;and\;SO_2$, concentrations measured at different site types(patterns of land use) show significant difference. The observed difference in concentration was associated with difference in emissions of $NO_2$ from motor vehicles and $SO_2$ by non-traffic fuel consumption for heating.

Performance Evaluation of Flow Injection Type Biosensor According to Operating Variables of Pump (펌프의 작동요인에 따른 흐름주입식 바이오센서의 성능 검증)

  • Song D. B.;Jung H. S.;Lee S. K.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.5 s.112
    • /
    • pp.312-317
    • /
    • 2005
  • A flow injection type biosensor was tested to confirm the performance of a batch and a continuous type flow injection unit. Reproducibility and consistence of the biosensor were investigated to determine the effect of pulsations and air bubbles, and the applicability of on-line monitoring. The air bubbles affected the performance of the sensor irrespective of the location, and also the pulsations of the pump influenced the performance of the sensor. The applicability of on-line motoring was accepted as the result of the repeated and long-term measurements.

HEALTH RISK ASSESSMENT OF HOUSEHOLD EXPOSURE TO INDOOR RADON IN ASSOCIATION WITH THE DWELLING'S AGE

  • Shahrokhi, Amin;Shokraee, Forough;Reza, Ali;Rahimi, Hasn
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.3
    • /
    • pp.155-161
    • /
    • 2015
  • Radon is a naturally occurring radioactive gas and a major indoor contribution of exposure to ionizing radiation in dwellings. $^{222}Rn$ is a health hazard gas what is responsible for thousand lung cancer deaths every year. In this study, indoor radon concentrations present in thirty representative houses in Mahallat city, Iran, were determined in order to estimate lung cancer risk associated with residential radon exposure. Long-term passive method, using CR-39, was used to measure the radon concentration. The results showed an association between the age of the dwellings and the indoor radon concentration that was found, in that the concentration of radon tended to increase as the age of the dwelling also increased. The indoor radon concentrations were calculated to be within the range of $23{\pm}2$ to $350{\pm}26Bq{\cdot}m^{-3}$, with an average of $158Bq{\cdot}m^{-3}$. The annual effective dose from inhaled radon and its decay products was calculated between $0.8{\pm}0.1$ and $12.3{\pm}0.9mSv{\cdot}y^{-1}$, with an average of $5.5mSv{\cdot}y^{-1}$. By taking into consideration the EPA recommendation and ICRP statement, the average annual risk of lung cancer from inhaled radon was calculated as 0.09%, 0.06%, 0.01%, and 0.03% for current smokers (CS), those who had ever smoked (ES), never smokers (NS) and the general population, respectively.

Design and implementation of a SHM system for a heritage timber building

  • Yang, Qingshan;Wang, Juan;Kim, Sunjoong;Chen, Huihui;Spencer, Billie F. Jr.
    • Smart Structures and Systems
    • /
    • v.29 no.4
    • /
    • pp.561-576
    • /
    • 2022
  • Heritage timber structures represent the history and culture of a nation. These structures have been inherited from previous generations; however, they inevitably exhibit deterioration over time, potentially leading to structural deficiencies. Structural Health Monitoring (SHM) offers the potential to assess operational anomalies, deterioration, and damage through processing and analysis of data collected from transducers and sensors mounted on the structure. This paper reports on the design and implementation of a long-term SHM system on the Feiyun Wooden Pavilion in China, a three-story timber building built more than 500 years ago. The principles and features of the design and implementation of SHM systems for heritage timber buildings are systematically discussed. In total, 104 sensors of 6 different types are deployed on the structure to monitor the environmental effects and structural responses, including air temperature and humidity, wind speed and direction, structural temperatures, strain, inclination, and acceleration. In addition, integrated data acquisition and transmission subsystem using a newly developed software platform are implemented. Selected preliminary statistical and correlation analysis using one year of monitoring data are presented to demonstrate the condition assessment capability of the system based on the monitoring data.

State Monitoring of Compressor using AE Signal in Life Test (압축기의 수명실험에서의 AE 신호를 이용한 상태감시)

  • 정지홍;강명창;노태영;이감규
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.56-60
    • /
    • 1997
  • The compressor is one of important elements in refrigeration cycle and play an important role of refrigeration efficiency and quality. This paper analyzes slides in rotary compressors for room air conditioners, monitoring using Acoustic Emission(AE) technique. Reliability of rotary compressors which are factory-tested has been evaluated through visual inspection on taking them apart after long term test, which is life test. This paper describes methods for acquisition and processing of Acoustic Emission(AE) raw signal to monitor state of rotary compressor in Life Test.

  • PDF