• Title/Summary/Keyword: Long-Term Work

Search Result 981, Processing Time 0.026 seconds

Gas Transfer and Hemolysis Characteristics of a New Type Intravenous Lung Assist Device (혈관 내 신형 폐보조장치의 기체전달 및 용혈 특성)

  • 김기범;권대규;정경락;이삼철
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.2
    • /
    • pp.121-126
    • /
    • 2003
  • The purpose of this work was to assess and quantify whether the beneficial effects in long-term gas exchange at exciting frequency were obtained at different frequencies as well and then to develop a vibrating intravascular lung assist device(VIVLAD), for Patients suffering from acute respiratory distress syndrome(ARDS) or chronic respiratory problems. We investigate the optimal condition of the frequency band excited with new vibrator at state of limit hemolysis when blood hemolysis came to through a membrane vibration action. The experimental design and procedures were given for a device used to assess the effectiveness of membrane vibrations. Quantitative experimental measurements were performed to evaluate the performance of the device . and to identify membrane vibration dependence on blood hemolysis. We developed an analytical solution for the hydrodynamics of flow through a bundle of sinusoidally vibrated hollow fibers that is used to provide some insight into how wall vibrations might enhance the performance of the VIVLAD. In the result, it was measured that the effect of various excited frequencies in gas transfer rate and hemolysis from the maximum gas transfer rate at no vibration when the maximum gas transfer rates showed at module type 6, module type 6 consisted of 675 hollow fiber membranes The maximum oxygen transfer rate was caused by the occurrence of maximum amplitude and transfer of vibration to hollow fiber membranes when it was excited by the frequency band of 7Hz at each blood flow rate. because this frequency became the End mode resonance frequency of the flexible in blood flow. Also, when module type 6 was excited at an excited frequency of 7Hz. blood hemolysis was low. Therefore, we decided that the limit of hemolysis frequency is 7Hz . because maximum amplitude occurred at this frequency.

Damage of Overlaid Concrete Structures Subjected to Humidity Changes in the Atmosphere (습도 변화에 따른 콘크리트 덧씌우기 보수체의 손상분석)

  • 윤우현
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.5
    • /
    • pp.766-773
    • /
    • 2002
  • The failure phenomenon of overlaid concrete structures, such as surface crack, and peel-off failure, shear bond failure in the end contact zone, was investigated due to humidity changes. To investigate this failure phenomenon, the surface tensile stress, and the shear stress, the vertical tensile stress in the contact zone were analysed using the non-linear stress-strain relationship of material such as strain-hardening- and strain-softening diagrams. Overlay thickness and overlay material were the main variables in the analyses. It is assumed that the initial surface humidity of overlaid concrete structures was 100% r.H. With a atmospheric humidity of 55% r.H. and two load cases for drying(LCI), curing and drying(LC2), the stress states of overlaid concrete structures were calculated. The result shows that only fictitious cracks occurred in the overlay surface of CM2O, ECM25, and no shear bond failure occurred in the contact zone without CM2O. The peel-off failure was proved to be the main cause of the damage in the overlaid concrete structures. Only for overlay thickness of 1cm occurred no peel-off failure in the case of drying after a long-term public use(LC1). In the case of curing and drying during overlay work(LC2) occurred the peel-off failure within 1.5days for all the overlaid concrete structures.

The Exceedance Patterns of O3 Air Quality Standards from 31 Monitoring Stations in Seoul (오존의 환경기준 초과양상에 대한 연구)

  • Kim, Min-Young;Choi, Ye-Jin;Kim, Ki-Hyun
    • Journal of the Korean earth science society
    • /
    • v.23 no.8
    • /
    • pp.683-696
    • /
    • 2002
  • In this work. we investigated the ozone data sets that exceeded ambient air quality standards from 31 air quality monitoring stations dispersed across the Seoul metropolitan city during the period covering 1990 and 2000. To specifically describe spatial dependency of high level O$_3$ occurrence, we grouped our data into four different geographical ozone exceedance is much longer in SW than the other three sectors. When we compared the exceedance data in terms of occurrence frequency, the month of maximum frequency differed slightly among different sectors. Examination of long-term exceedance trend indicated that its frequency increased continuously from all sectors over the past years, although slightly opposite patterns existed in their absolute values. Most importantly, its peak occurrence frequency seemed to center in very recent years such as 1998 (NE sector) and 2000 (ail pattern sectors except NE). Consequently, we were able to describe the existence of certain patterns of ozone exceedance data sets in terms of both temporal and spatial scales.

A Study on the Critical Point and Bifurcation According to Load Mode of Dome-Typed Space Frame Structures (돔형 스페이스 프레임 구조물의 하중모드에 따른 분기점 특성에 관한 연구)

  • Shon, Su-Deok;Kim, Seung-Deog;Lee, Seung-Jae;Kim, Jong-Sik
    • Journal of Korean Association for Spatial Structures
    • /
    • v.11 no.1
    • /
    • pp.121-130
    • /
    • 2011
  • Space frame structures have the advantage of constructing a large space structures without column and it may be considered as a shell structure. Nevertheless, with the characteristics of thin and long term of spacing, the unstable problem of space structure could not be set up clearly, and there is a huge difference between theory and experiment. Therefore, in this work, the tangential stiffness matrix of space frame structures is studied to solve the instability problem, and the nonlinear incremental analysis of the structures considering rise-span ratio(${\mu}$) and the ratio of load($R_L$) is performed for searching unstable points. Basing on the results of the example, global buckling can be happened by low rise-span ratio(${\mu}$), nodal buckling can be occurred by high rise-span ratio(${\mu}$). And in case of multi node space structure applying the ratio of load($R_L$), the nodal buckling phenomenon occur at low the ratio of load($R_L$), the global buckling occur a1 high the ratio of load($R_L$). In case of the global buckling, the load of bifurcation is about from 50% to 70% of perfect one's snap-through load.

A Study on the Establishment of Clinical Nurse Specialist (우리나라 전문간호사제도 개선방안에 관한 연구)

  • Byun, Young-Soon;Kim, Young-Im;Song, Mi-Sook
    • Research in Community and Public Health Nursing
    • /
    • v.5 no.2
    • /
    • pp.130-146
    • /
    • 1994
  • Our medical care system is trying to diversify in order to meet the client's needs, and to adjust to a medical environment which is changing very rapidly. Because current nursing theory and practice focus on holistic care, health care management, education, and research, contrary to the traditional emphasis on only assisting a physician, more autonomy and specialization for the implementation of nursing are required. Considering these trends and actual needs, the category of clinical nurse specialist should be established as soon as possible. In order to develop strategies for implementing this new professional specialty, the authors conducted a field survey and literature review of the current system in Korea. As a result, various obstacles and constraints were discovered as follows : 1) There are few accredited educational programs for the training of CNS's. 2) Several hospitals already have staff designated as clinical nurse specialist (CNS) even though the term CNS is not yet standardized or adopted in nationwide. 3) The role of the CNS is not clearly understood by the medical societies, or even nursing societies. A nurse who works in specific nursing areas such as central supply, kidney dialysis, intensive care, coronary care, etc. for a long time, considers herself /himself a CNS. Based upon the above findings, the following alternatives are recommended. 1) The role of the CNS should be defined according to specified functions and authority : professional autonomy ; counselling and educating patients and their familes, nurses, and even other medical personnel ; research on improvement of nursing ; and management of the nursing environment including medical resources, information, and cases. 2) the qualification of CNS should be attained only by a nurse who has an RN license and clinical experience of more than 3 years in a specific nursing field: passes a qualifying examination; and contributes to the professional development of peers, colleagues, and others. A master's degree should only be optional, because of the insufficient of graduate programs which are well designed for the CNS. 3) The CNS should initially be a head nurse rather than line staff in order to deal with as wide an experience base as possible. 4) The nursing specialty could be divided into two areas such as a clinical field and a community field. The clinical field could then be categorized by the Styles' classification such as diseases and pathogenics, systems, ages, acuity, skills/techniques, and function/role ; the community field could be classified according to work site.

  • PDF

Effects of the College Financial Support Program on Development of the Department (전문대학 재정지원사업이 학과발전에 미치는 영향연구)

  • Yoou, Soon Kyu;Choi, Hea Kyung;Uhm, Tai Hwan
    • The Korean Journal of Emergency Medical Services
    • /
    • v.7 no.1
    • /
    • pp.213-234
    • /
    • 2003
  • The purposes of this study which was done by questionnaire survey and case study of First Aid Certification Program in Seoul Health College were to analyze results and effects of the college financial support program from Ministry of Education & Human Resources Development. The significant 164 data were collected from 300 professors in 8 colleges having the Department of Emergency Care from Oct. 1, 2002 to Dec. 31, 2002 and analyzed using SPSS in terms of t-test, ANOVA, Pearson's correlation coefficient and so on. The conclusions and suggestions from this study were summarized as follows; (1) Degree of acknowledgement about aims, contents, results of the college financial support program was above the middle(participants 4.21, non-participants 3.63) and higher relation than the others in case of participants(r:0.32 p<0.001), planning team(r:0.22 p<0.05). (2) Degree of acknowledgement about improvement of curriculum & educational facilities through the program was above the middle and higher relation than the others in case of participants. (3) Degree of acknowledgement about positive influence on acquirement rate of certification(licence) & job through the program was above the middle and performance & adaptation at work place was higher relation than the others in case of participants. (4) Degree of acknowledgement about positive influence on improvement of learning of student's major through the program was above the middle and higher relation than the others in case of participants. (5) The respondents thought that the program had a negative influence on professor's educational activities & research such as study 40.4%, lecture 23.1%, student guidance 12.5%. (6) When the program was administered by planning team, there were difficulties such as execution of budget 42.1%, cooperation with companies 17.1%, cooperation among program teams 11.8%, when it was administered by non-planning team there were difficulties such as execution of budget 45.5%, cooperation among departments 22.7%, cooperation with companies 13.6%. (7) Because it was too short to execute the budget, the ministry have to select proposed programs before the next school year. (8) This program should be changed temporary, insufficient support into consecutive, sufficient support for more characterization & specialization of the college which has a long-term developmental plan & vision.

  • PDF

Leakage Currents Flowing through Lightning Surge Arresters under Various Fault Conditions in Receiving and Distribution Power Systems (수배전계통의 여러 가지 고장조건에서 피뢰기에 흐르는 누설전류)

  • Lee, Bok-Hee;Kil, Hyeong-Joon;Kang, Sung-Man;Choi, Hwee-Sung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.132-139
    • /
    • 2004
  • Unsymmetrical faults are classified into single line-to-ground faults, line-to-line faults, or double line-to-ground faults in receiving and distribution power systems. Many of overhead distribution-line faults are single line-to-ground faults, and lightning surge arresters are stressed by system frequency overvoltages due to unsymmetrical faults. In this work, the unsymmetrical faults in receiving and distribution systems were experimentally simulated, and the characteristics of total leakage current flowing through lightning surge arresters due to various unsymmetrical faults were investigated. As a result, a little variations of the leakage current flowing through Zinc oxide (ZnO) surge arresters in the range of $\pm$10[%] voltage regulations were observed. It could be concluded that the unsymmetrical faults have no effect on the long-term life performance of ZnO surge arresters in effective grounding systems. On the other hand, the magnitude of the leakage current flowing through ZnO surge arrester elements under single line-to-ground faults was more than 140 times as compared with that under normal operating voltages in ineffective grounding systems. But abnormal voltages caused by line-to-line faults and double line-to-ground faults have a little effect on total leakage current of ZnO surge arrester elements.

Effect of Preharvest Sprayable 1-Methylcyclopropene (1-MCP) Treatment on Fruit Quality Attributes in Cold Stored 'Gamhong' Apples (수확전 수체살포용 1-MCP 처리가 '감홍' 사과의 저온저장 중 과실품질에 미치는 영향)

  • Yoo, Jingi;Kim, Dae Hyun;Lee, Jinwook;Choi, Dong Geun;Han, Jeung-Sul;Kwon, Soon-Il;Kweon, Hun-Joong;Kang, In-Kyu
    • Journal of Bio-Environment Control
    • /
    • v.22 no.3
    • /
    • pp.279-283
    • /
    • 2013
  • This work was carried out to evaluate the effect of preharvest sprayable 1-methylcyclopropene (1-MCP: $Harvista^{TM}$) treatment on the fruit quality attributes in cold stored 'Gamhong' (Malus domestica Borkh) apples. Preharvest sprayable 1-MCP treatment did not affect fruit qualities at harvest but titratable acidity (TA) was higher in fruit treated 10 days before harvest (DBH) than in control. During cold storage, fruit firmness and TA were higher in 1-MCP treated fruit than in control fruit as storage duration progressed, while SSC was not affected. Internal ethylene concentration (IEC) levels were not different among treatments at harvest. While the IEC level in control fruit reached to $58.3{\mu}L{\cdot}L^{-1}$ after 6 month cold storage, the IEC levels in 1-MCP treated fruit ranged from 18.2 to $25.0{\mu}L{\cdot}L^{-1}$. Therefore, this result indicates that preharvest sprayable 1-MCP treatment should be another promising approach to retain fruit quality attributes in long-term cold stored 'Gamhong' apples.

Root cause analysis of the abnormal wear on diesel engine crankpin and lubricant contamination (윤활유 오염과 디젤엔진의 크랭크핀 이상마모에 대한 원인 규명)

  • Seo, Jeongwoo;Park, Donghee
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.7
    • /
    • pp.854-867
    • /
    • 2014
  • In the circumstance that high oil price state is continued over the world, the investment in crude oil development by oil major is a trend of increasing. Recently the number of delivered drill-ship for 5 years has been sharply increased all over the world and about twice than that of past 30 years. As addition to the increase of the drill-ship demand, the operation of drill-ships which is delivered recently is about 3,000 meters, ultra deep sea, on average and the work area is expending. Accordingly the drilling system including the size and length of pipe for drilling has been bigger and bigger and the power supply equipment for operation system also has large capacity. Unlike merchant vessel, high power and high voltage of diesel generators are required for drill-ship for which the demand for V-type 320 bore of diesel generator has increased. It is on the raised that the importance of lubrication oil cleaning for diesel generator on drill-ship which has longer time for construction, and also long term low load operation is unavoidable during commissioning of equipments. Recently it was reported that engine crankpin was damaged due to the hard contact caused by the abnormal wear down(Cam wear) on crankpin and bearing. The same pattern of wear down was found through the inspection on series vessels and the other vessel under commissioning. The purpose of this paper is to analyze of the wear mechanism based on the observation and theories and objective research from actual cases and to prepare the counter measures to avoid foreseeable damage when the lubricating oil is not properly cleaned.

Oral health knowledge level on oral care and elder oral hygiene care of the nursing home staff in long-term care facilities (노인요양시설 요양보호사의 구강관리 및 노인구강위생관리에 따른 구강보건지식 수준)

  • Kim, Kyung-Min;Park, Young-Nam;Lee, Min-Kyung;Lee, Jung-Hwa;Yoon, Hyun-Seo;Jin, Hye-Jung;Kim, Hye-Jin
    • Journal of Korean society of Dental Hygiene
    • /
    • v.14 no.5
    • /
    • pp.723-730
    • /
    • 2014
  • Objectives : This research was conducted to investigate geriatric care workers' oral care, and the oral care conditions of residents of elder care facilities in relation to workers' knowledge of oral care. Methods : A survey was conducted from November 2011 to February 2012 with geriatric-care workers in elder care facilities located in Busan and other areas of Gyeongsangnam-do. Results : With regard to their oral self-care practices, 52.5% of the geriatric workers "brushed their teeth from top to bottom" and 58.1% brushed their teeth 3 times a day. Further, 52.0% did not use any oral care products, while 36.5% used Mouthrinese. The workers who brushed their teeth in their own ways or from top to bottom had significantly higher oral care knowledge scores than those who brushed from left to right (p<.05). Concerning oral hygiene care for residents, 72.6% of the geriatric workers recommended that elders visit dentists for oral care, 96.6% helped elders oral wash their teeth every day, and 54.7% used oral care products for the elders. The workers who did not recommend visits to dental clinics scored slightly higher than those who did (p<.05). Additionally, those who did not help elders oral wash their teeth scored significantly higher than those who did (p<.05). Except for oral wash to recuperated old man and recommendation of visiting the dentist, relation between oral care and knowledge about oral health and oral hygiene care is plus mutual relation. Conclusions : To manage the accuracy and quality of oral care work performed by geriatric care workers in elder care facilities, enhancing standard training and education on oral care is necessary. Providing systematic, regular education on such knowledge and practices would also be essential.