• Title/Summary/Keyword: Long pulse

Search Result 443, Processing Time 0.03 seconds

전기기기절연물중의 void pulse와 그 검출에 관한 연구

  • 성영권
    • 전기의세계
    • /
    • v.16 no.3
    • /
    • pp.21-27
    • /
    • 1967
  • We meet with the fact that a majority of electric machinery have been insulated to the state of solids & liquids or solids & gases, that is, with compound dielectrics. And also we can find voids caused by undesirbble structure, long-used material and so on. When it is discharged in a void or in the parts of gases of insulating material, the insulation of the machinery is gradually and finally destroyed through the effect of ozone, nitrogen-oxide, electronic pulses and so on. So we maybe conculded that it is necessary and important to detected void pulse and void corona in order to prevent sudden break down of electric machinery.

  • PDF

Design of High Average Power Pulse Transformer for 30-MW Klystron of L-Band Linac Application (산업용 선형가속기 시스템 적용을 위한 30-MW 클라이스트론용 고 평균전력 펄스 트랜스포머의 설계)

  • Jang, S.D.;Son, Y.G.;Gwon, S.J.;Oh, J.S.;Bae, Y.S.;Lee, H.G.;Moon, S.I.;Kim, S.H.;Cho, M.H.;NamKung, W.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1550-1551
    • /
    • 2006
  • An L-band linear accelerator system for e-beam sterilization is under design for bio-technology application. The klystron-modulator system as RF microwave source has an important role as major components to offer the system reliability for long time steady state operation. A PFN line type pulse generator with a peak power of 71.5-MW, $7{\mu}s$, 285 pps is required to drive a high-power klystron. The high power pulse transformer has a function of transferring pulse energy from a pulsed power source to a high power load. The pulse transformer producing a pulse with a peak voltage of 275 kV is required to produce 30-MW peak and 60 kW average RF output power at the frequency of 1.3-GHz. We have designed the high power pulse transformer with 1:13 step-up ratio. The peak and average power capability is 71.5-MW (275 kV, 260 A at load side with $7{\mu}s$ pulse width) and 130 kW, respectively. In this paper, we present a system overview and initial design results of the high power pulse transformer.

  • PDF

Parameter Evaluation of High-Power Pulse Transformer for L-Band 30-MW Klystron (L-band 30-MW 클라이스트론용 고출력 펄스트랜스포머의 파라미터 평가)

  • Jang, S.D.;Son, Y.G.;Kwon, S.J.;Oh, J.S.;Kim, S.H.;Yang, H.R.;Moon, S.I.;Kwon, B.H.;Cho, M.H.;NamKung, W.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1079-1081
    • /
    • 2007
  • An L-band Linear Accelerator System for E-beam sterilization is under construction for bio-technology application. The klystron-modulator system as an RF microwave source has an important role as major components to offer the system reliability for long time steady-state operations. A PFN line type pulse generator with a peak power of 71.5-MW, $7\;{\mu}s$, 285 pps is required to drive a high-power klystron. The high power pulse transformer has a function of transferring pulse energy from a pulsed power source to a high power load. The pulse transformer producing a pulse with a peak voltage of 275 kV is required to produce 30-MW peak and 60 kW average RF output power at the frequency of 1.3-GHz. We have designed the high power pulse transformer with 1:13 step-up ratio. The peak and average power capability is 71.5-MW (275 kV, 260 A at load side with $7\;{\mu}s$ pulse width) and 130 kW, respectively. In this paper, we present measurements and its analysis on the design parameters, and an initial test result as well as a design concept on the high-power pulse transformer.

  • PDF

Improvement of luminous efficiency through new cell structure and driving pulse

  • Ko, Sang-Woo;Yang, Sung-Soo;Kim, Hyun-Chul;Mukherjee, Sudeshna;Lee, Jae-Koo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.714-717
    • /
    • 2003
  • We have suggested several plasma display panel (PDP) cell structures for high luminance and low power consumption by our two-and three-dimensional fluid simulation codes. Generally, to improve luminous efficiency and discharge efficiency, it is known that it is lucrative to use long discharge path and to form low electric field. However, the problems are how to implement them effectively in the small PDP cell. Therefore, unlike conventional model, we suggest Front Three Electrodes (FTE) model. In this model, we tried to make long and V-shaped discharge path by geometry changes and driving pulse variations. Consequently, from our simulation results based on the model above, luminous efficiency has improved about 2.6 times.

  • PDF

Embodiment of Low Operating Voltage in Positive Column AC-PDPs

  • Kim, Hyun;Tae, Heung-Sik;Chien, Sung-Il
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.95-98
    • /
    • 2003
  • The positive column discharge characteristics in the long gap (440 ${\mu}m$) are investigated based on the voltage distribution among three electrodes. In particular, the effects of the amplitude and width of the short pulse applied to the address electrode on the positive column discharge characteristics are examined intensively. By proper controlling of the amplitude and width of the address short pulse, it is found that the positive column discharge in the long gap is well constructed. As a result, under the stable static voltage margin condition, the firing and sustaining voltages are as low as those of conventional short gap(60 ${\mu}m$) discharge($V _f=220V$, $V_s=150V$) and the color purity is improved. Moreover, the luminous efficiency increases up to 60% in comparison with the conventional case.

  • PDF

Spectral Properties of THz-Periodic Metallic Structures

  • Kang, Chul;Kee, Chul-Sik;Sohn, Ik-Bu;Lee, Jong-Min
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.3
    • /
    • pp.196-199
    • /
    • 2008
  • We have investigated spectral properties of the periodic arrays of aluminum rods and holes on papers using the terahertz time-domain spectroscopy. The size of a rod(hole) is $600{\mu}m{\times}100{\mu}m$ and the spacing is $300{\mu}m$. The samples were fabricated by a femtosecond laser micromachining system. The periodic arrays of aluminum rods exhibit high reflection around 0.25 THz when the polarization of the THz pulse is parallel to the long axis of the rod, whereas the periodic arrays of holes exhibit high transmission around 0.25 THz when the polarization of the THz pulse is perpendicular to the long axis of the hole.

Development and High Power RF Test of the Vacuum Feedthrough for KSTAR ICRF Antenna

  • Bae, Young-Dug;Hwang, Churl-Kew;Kwak, Jong-Gu
    • Nuclear Engineering and Technology
    • /
    • v.34 no.3
    • /
    • pp.211-217
    • /
    • 2002
  • A 1-MW vacuum feedthrough for the KSTAR ICRF antenna is fabricated and high power RF test is performed. It is designed to have two alumina $(Al_2O_3)$ ceramic cylinders and O-ring seal instead of a brazed seal for good mechanical and thermal strength, which is important in long pulse or steady state operation. For cooling of the ceramics, dry air is circulated in a space between the two cylinders and the outer conductor. Independent cooling water channels are installed to cool the inner conductor of the feedthrough. RF high voltage test is performed using two kinds of ceramics with the purities of 99.7% and 97%. Stable operation is possible with the RF voltage of 30 kVp at long pulse of 300 sec without any severe damage.

Case of Prominent Periorbital Vein after Lower Eyelid Blepharoplasty Treated with a Long-pulse 1,064-nm Neodymium: Yttrium-aluminum-garnet Laser

  • Kim, Wan Jin;Cho, Han Kyoung;Lee, Sang Ju
    • Medical Lasers
    • /
    • v.9 no.2
    • /
    • pp.184-186
    • /
    • 2020
  • Lower eyelid blepharoplasty is a popular facial rejuvenation surgery that restores the infraorbital region. The procedure is performed by removing excessive fatty tissues, muscles, and other unnecessary structures. The structure of the eyelid differs from person to person and is quite complex; therefore, numerous side effects are expected. Common lower eyelid blepharoplasty complications are asymmetrical faces, retrobulbar hemorrhage, blurred vision, and ectropion. This paper reports a case of a prominent periorbital vein after lower eyelid blepharoplasty. The prominent periorbital vein after surgery is a rare side effect that has not been reported to the best of the author's knowledge. This case was treated with a long-pulse 1,064-nm neodymium:yttrium-aluminum-garnet laser.

Echolocation Signals of Pipistrellus abramus in Relation to Environmental Type (환경특성에 따른 집박쥐의 반향정위(Echolocation) 시그널 분석)

  • Chung, Chul-Un;Han, Sang-Hoon;Kim, Sung-Chul;Lee, Chong-Il
    • Korean Journal of Environment and Ecology
    • /
    • v.23 no.6
    • /
    • pp.553-563
    • /
    • 2009
  • This study was conducted to analyze the changes in the echolocation of Pipistrellus abramus according to environmental characteristics. The survey was conducted in the day-roosting site of P. abramus located in Gyeongju City (North Gyeongsang Province) from April to August, 2009. The environmental characteristics during the research were classified in six categories: the emergence time after sunset moving time from day roost to feeding areas; rice fields; forest edges; open spaces; and residential areas. Analysis results showed that there are differences in environmental characteristics and also differences between the moving time to the habitat and the moving time to capture preys. At the emergence time from day roost, Pipistrellus abramus used a FM signal with a short pulse-duration. In open spaces, however, they used a CF signal with a long pulse-duration. In different environmental situations, they used both FM and CF signals, although the types of pulse which they used were different. Except pulse-duration, there were significant differences in pulse-interval, peak-frequency, starting-frequency and ending-frequency between the movement among habitats and the movement to capture preys. Except the emergence time from day-roost, they showed a narrow band FM signal and a long pulse-duration that are suitable to search for insects by sensing echoes of insects when they moved among their habitats. When they were out to capture their preys, they showed a broad band FM signal and a short pulse-duration which enabled them to widely search and accurately locate their preys.

Survey Study about Sasangin's Characteristics of Face, Voice, Skin and Pulse Diagnosis (사상인(四象人)의 안면, 음성, 피부 및 맥진 특성에 관한 설문조사 연구)

  • Lee, Jun-Hee;Kim, Yun-Hee;Hwang, Min-Woo;Kim, Jong-Yeol;Lee, Eui-Ju;Song, Il-Byung;Koh, Byung-Hee
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.3
    • /
    • pp.126-143
    • /
    • 2007
  • 1. Objectives The purpose of this study is to find out the grade of practical use, the important element and the significant characteristics of Sasangin' s face, voice, skin and pulse diagnostic impression, in Sasang constitutional clinical diagnosis. 2. Methods We analysed the survey data about Sasangin' s face, voice, skin and pulse diagnostic impression, drawn up by specialist in Sasang constitutional medicine. 3. Results and Conclusions (1) In the application degree of face feature, the case which it was applied with 20-40% and 40-60% were 16 people(43.2%) respectively. In voice, the case applied with 0-20% was 19 people(51.4%), in skin, 0-20% and 20-40% were 14 people(37.8%) respectively and in pulse diagnosis, 0-20% were 25 people(73.0%). (2) In constitutional diagnosis, the important element of face were 'frontal whole shape', 'whole impression' and 'size and shape of eye, ear, mose and mouth', the important element of voice 'speed of speech', 'purity and impurity' and 'pitch', the important element of skin 'thickness', 'feel of touch' and 'size of skin pores' and the important element of pulse diagnosis 'speed of pulse', 'sinking and floating' and 'weakness and firmness'. (3) The important face characteristics of Taeyangin were 'bright eye', 'broad forehead' and 'strong impression', Soyangin 'protruding forehead', 'thin and small lips', 'narrowing and sharp chin', Taeumin 'thick lips', 'flat face', 'large eye, nose, ear and mouth' and Soeumin 'long and slender face', 'downward slanting eyes' and 'small eye, nose, ear and mouth', The important voice characteristics of Taeyangin were 'loud' and 'clear', Soyangin 'rapid' and 'high-pitched tone', Taeumin 'chick', 'slow' and 'low-pitched tone' and Soeumin 'small and feeble' and 'slow'. The important skin characteristics of Taeyangin were 'thin' and 'white', Soyangin 'thin', 'smooth' and 'elastic', Taeumin 'thick', 'large skin-pore', 'coarse' and Soeumin 'soft', 'thin' and 'subtle skin-pore'. The important pulse characteristics of Taeyangin were 'rapid' and 'large', Soyangin 'rapid' and 'floating', Taeumin 'tense', 'long' and 'solid' and Soeumin 'fine', 'weak' and 'slow'.

  • PDF