• 제목/요약/키워드: Long Tube

검색결과 613건 처리시간 0.029초

기관 협착에서 Long T-tube의 삽입 방법 (A technique for insertion of a long T-tube in tracheal stenosis)

  • 백만종
    • Journal of Chest Surgery
    • /
    • 제26권8호
    • /
    • pp.664-666
    • /
    • 1993
  • A technique for insertion of a long silicone T-tube in patient with critical stenosis and high-risk resection and primary anastomosis of long segment of the distal trachea is presented. It was not easy to insert a long T-tube by existing methods because of flexibility of a T-tube and tightness of stenosis. So we used a silastic endotracheal tube and guiding wire as stylet of a T-tube. During insertion, ventilation was normally maintained through the lumen of endotracheal tube. This provided rapid relief from airway obstruction and asphyxation and is a easy, safe and effective method to restore patency of the major airways.

  • PDF

Design of compact phase controller for pulse tube refrigerator

  • Ki, Tae-Kyung;Jeong, Sang-Kwon
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권2호
    • /
    • pp.25-28
    • /
    • 2011
  • A compact phase controller of pulse tube refrigerator is proposed in this paper. Most pulse tube refrigerators available now consist of a long inertance tube and reservoir as the phase controller. The long inertance tube and reservoir present a challenge for compact packaging in some applications. To overcome this disadvantage, the long inertance tube and reservoir are replaced with the compact phase controller consisted of mass, spring and damper in pulse tube refrigerator. This process is achieved using similarity of mechanical, electrical, and acoustic system and the specific configuration of the compact phase controller is designed. From the simulation code in this paper, the performance of pulse tube refrigerator with the designed compact phase controller is confirmed to be comparable to pulse tube refrigerator with the long inertance tube and reservoir.

공기 지중간 직접열교환시스템의 열성능 해석 (Analysis of the thermal performances of air-earth direct heat exchanger)

  • 김원갑;안정수;최영돈
    • 설비공학논문집
    • /
    • 제9권2호
    • /
    • pp.112-121
    • /
    • 1997
  • This study is focused on the development and selection of optimal cool tube system to maximize its thermal performance. Cool tube is devised to reduce the heating and cooling load of building by preheating or refreshing of intake air. Finite volume method was adopted to solve the conduction problem between the cool tube and earth. We examine the cool tube system for two operating periods, a short term(12 hours) and a long term(3 months). The results of short term operations reveal that condensation significantly influences and raises the exit air temperature. For long term operations, optimum conditions of cool tube system are obtained with variations of flow-rate, depth, length and diameter of cool tube.

  • PDF

단일(單一) 긴 수직평판(垂直平板)핀을 가진 수평전도관(水平傳導管)으로 부터의 자연대류(自然對流) (Conjugate Heat Transfer by Natural Convection from a Horizontal Heat Exchanger Tube with a Long Vertical Longitudinal Plate Fin)

  • 배대석;권순석
    • 설비공학논문집
    • /
    • 제1권1호
    • /
    • pp.64-72
    • /
    • 1989
  • Laminar natural convection heat transfer from a horizontal heat exchanger tube with one infinitely long vertical plate fin has been studied by a finite-difference numerical procedure. In predicting convective heat transfer from a circular tube, the thermal boundary condition at solid fluid interface is usually assumed to be isothermal. However, in reality, the thermal boundary condition is not isothermal, and the tube has the thickness and the conductivity. So the temperature at the interface is not known a priori to the calculation. This problem has the conjugate phenomena which occur between the tube conduction and external natural convection, and between the fin conduction and external natural convection. Numerical results are obtained to determine the effects of the conductivity of solid wall and the thickness of tube wall on heat transfer. It is found that the conduction causes significant influence on the natural convection heat transfer at low K and high ${\delta}$.

  • PDF

공기 지중간 직접열교환시스템의 연중 열성능 해석 (Analysis on the thermal performances of air-earth direct heat exchanger in one year)

  • 김원갑;안정수;최영돈
    • 설비공학논문집
    • /
    • 제9권4호
    • /
    • pp.517-526
    • /
    • 1997
  • This study is focused on the development and selection of the optimal cool tube system to maximize its thermal performance. Cool tube is devised to reduce the heating and cooling load of building by preheating or refreshing of intake air with buried pipes. Finite volume method is adopted to solve the conduction problem between the cool tube and earth. We examine the cool tube system for two operating periods, a short term(12 hours) and a long term(3 months). The results of short term operations reveal that condensation significantly influences and raises the exit air temperature. For long term operations, optimum conditions of cool tube system are obtained with variations of flow-rate, depth, length and diameter of cool tube.

  • PDF

Growth and Flowering Responses of Petunia to Various Artificial Light Sources with Different Light Qualities

  • Park, In Sook;Cho, Kyung Jin;Kim, Jiseon;Cho, Ji Yoon;Lim, Tae Jo;Oh, Wook
    • 원예과학기술지
    • /
    • 제34권1호
    • /
    • pp.55-66
    • /
    • 2016
  • This study was carried out to investigate the effect of artificial light sources with different light qualities on the growth and flowering characteristics of a herbaceous long-day plant, Petunia ${\times}$ hybrida Hort. Seedlings of petunia cultivar 'Madness Rose' were potted, acclimated for one week, and grown in a phytotron equipped with tube- and bulb-type fluorescent lamps (FL tube and bulb), tube-type white light-emitting diodes (LED tube), halogen lamps (HL), metal halide lamps (MH), and high pressure sodium lamps (HPS) for 10 weeks. The temperature, photoperiod, and photosynthetic photon flux density (PPFD) in the phytotron were $22{\pm}2^{\circ}C$, 16 h, and $25{\pm}2{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, respectively. Light sources combined with HL promoted stem elongation, and plant height and internode length decreased with increasing red to far-red (R:FR) ratio. FL tube + LED tube, HPS, and FL tube promoted branching, whereas plants grown under light sources combined with HL did not have any branches. Days to flowering (from longest to shortest) occurred as follows: FL tube + HL > FL tube + HL > MH > HPS = FL tube + FL bulb > FL tube + LED tube > LED tube > FL tube, indicating that reducing the R:FR ratio of the light sources promoted flowering. Only 20% of plants grown under an FL tube flowered, whereas under all other treatments, 100% of plants flowered. At 10 weeks after treatment, plants grown under HPS and MH had (cumulatively) 12 open flowers, and those grown under FL tube + FL bulb, LED tube, FL tube + LED tube, and HPS treatment had approximately seven flower buds. These results suggest that light sources with low R:FR ratios promote flowering and stem elongation in petunia, but they reduce its ornamental value due to overgrowth and poor branching.

저층수 흡입식 광역 순환장치의 설계변수에 따른 배출량 및 소비동력 변화 특성에 대한 수치 해석 연구 (Numerical Analysis on Changes in Flowrate of Draft Water and Power by Changing Design Parameters of a Long-Distance Water Circulation)

  • 송동근;홍원석;김영철;박명하
    • 한국유체기계학회 논문집
    • /
    • 제13권1호
    • /
    • pp.23-28
    • /
    • 2010
  • A draft tube which has impeller to elevate bottom water and spread it over surface of lake water, induces convective circulation of lake water, a Long-Distance Circulation (LDC). Circulation of lake water make stratified water mixed and enhance DO (Dissolved Oxygen) of bottom water. Circulation rate of water is determined by draft rate of the tube, which is dependent on design parameters of the draft tube system, i. e. dimension of impeller and diffuser, inclined angle of impeller, impeller shape, and rotational speed. In this study, change in draft rate and power consumption of circulation equipment was investigated numerically with changing impeller dimension, angle and rotational speed. It was found that flowrate of draft water was increased as the dimensions of draft tube and impeller, and rotational speed and inclined angle of impeller increased. The power consumption was also elevated with increasing parameter values, and final selection of parameter values was made to satisfy target flowrates and power consumption.

중공축 내접 스플라인 성형을 위한 설계변수의 영향 (Effect of the Design Parameter for Internal Spline Forming Using the Tube)

  • 왕창범;임성주;박용복
    • 소성∙가공
    • /
    • 제15권7호
    • /
    • pp.512-517
    • /
    • 2006
  • In this paper, the cold extrusion process for internal spline forming using a thin and long tube has been analyzed by using a rigid plastic finite element code. The internal spline consists of 10 tooths. The cold extrusion process has been focused on the comparisions of load-stroke relation and filling states of the teeth according to design parameters. The design parameters involve extrusion ratio, extrusion angle and friction factor. The internal spline forming can cause the buckling and folding during the cold extrusion process because of using a thin and long tube. The optimum design parameters have been obtained through rigid-plastic finite elements analysis. The extrusion ratio and extrusion angle have great effects on the deformation characteristics of the cold extrusion process.

선천성 식도 폐쇄에서의 역위관 거치술 (Reversed Gastric Tube Interposition in Esophageal Atresia)

  • 허승;전용순;박귀원;김우기
    • Advances in pediatric surgery
    • /
    • 제1권2호
    • /
    • pp.162-169
    • /
    • 1995
  • Since 1988, we have performed esophageal replacement with the reversed gastric tube on four esophageal atresia patients. Three patients had long-gap esophageal atresias and one patient had recurrent tracheoesophageal fistula that was previously operated on three times. One combined imperforate anus. The youngest patient was 6-month-old and the oldest, 34-month-old at the time of procedure. The technique of gastric tube construction is described. There have been both major and minor complications. Although two patients had shown distal tube strictures as late complications. those were solved with tuboplasties on 29 months and 48 months, postoperatively. Growth and development have been acceptable in all four patients, although most remain in the lower percentiles for growth and height, a condition that usually predates the esophageal substitution. Conclusively, reversed gastric tube interposition has proved very satisfactory for long-gap esophageal atresia that cannot be anastomosed primarily even by spiral myotomy and esophageal atresia with recurrent tracheoesophageal fistula having destroyed esophagus due to previous operation.

  • PDF