• Title/Summary/Keyword: Long Life Test

Search Result 614, Processing Time 0.029 seconds

A Study on Flow Rate Properties and Optimal Selection of Nitrogen Membrane Module of Hollow Fiber Type (중공사형 질소 분리막 모듈의 최적 선정과 유량특성에 관한 연구)

  • Kim, Jong-Do;Lee, Sangu-Su;Kim, Jeon-Ha
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.6
    • /
    • pp.915-922
    • /
    • 2008
  • The gas separation technology using membrane is widely used to refine various gases in many industry fields and recently is being applying in $CO_2$ recovery technology. In the gas and chemical tanker. nitrogen generators for inerting, purging and padding are on board and most of them have membrane modules of hollow fiber type with long life and vibration resisting properties. Because a membrane module is a key component accounting for 50% of total manufacturing cost of nitrogen generator, adequate selection for it is an important problem. In this paper, the flow performance coefficient based on dimension and specification data of membrane module was relatively selected to compare nitrogen generating capacity of module and various performance tests about the selected PARKER ST6010 membrane module were conducted. As a result, the useful coefficient and basic data in selecting a membrane module were achieved.

The Study of Antibiosis of the Fabrics Dyed by Wormwood Extract (쑥 추출액을 이용한 염색직물의 항균성에 관한 연구)

  • 박영희;남윤자;김동현
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.24 no.1
    • /
    • pp.67-76
    • /
    • 2000
  • Dyeing fastness and antibiosis effects of fabrics dyed with wormwood, which has been used in folk medicines and dietary life in Korea for a long time, were studied through dyeing small overcoats, which are used as diapers, with wormwood extract. As for the dying fastness test results, the fastness of decoloration was not that good but the pollution level showed a relatively positive result. As for the antibiosis effect results, the antibiosis of the dyed sample was better than the original sample on 3 kinds of bacteria, Escherichia coli, Staphylococcus aureus, Staphylococcus epidermidis and on 2 kinds of the fungi(Eumycetes). Aspergillus niger and Candida albicans. Especially, the sample that was mordant with CaCl2 and FeSO4·7H2O showed the best antibiosis effect. On the other hand, the sample that showed the best antibiosis effect was the refined fabric, which is a fabric that is not dyed.

  • PDF

A Study on Development of Pavement Management System for Cement Concrete Pavement (시멘트콘크리트포장의 유지관리체계(PMS)에 관한 연구)

  • 엄주용;김남호;임승욱
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.04a
    • /
    • pp.363-369
    • /
    • 1996
  • PMS(Pavement Management System) is the effective and efficient decision making system to provide pavements in an acceptable condition at the lowest life-cycle cost. As the highway system become larger, the necessity of the PMS in increasing. As of December 1995, the 3rd stage of PMS project was completed. The accomplishment of the research work can be itemized to the followings : $\bullet$ Calibration of PMS submodules (1) Pavement Condition Evaluation Model (2) Pavement Distress Prediction Model (3) Pavement Performance Prediction Mode (4) Selection of Pavement Rehabilitation Criteria (5) Optimization Technique for PMS Economic Analysis $\bullet$ Development of Computer Program to Implement PMS Logic $\bullet$ A Study to Implement the Automized Pavement Condition Survey Equipment to PMS $\bullet$ PMS Test Run $\bullet$ Development of PMS Operation Guideline $\bullet$ The 2nd Pavement Condition Survey for Long-Term Pavement Performance Monitoring.

  • PDF

The Experimental Study of Miniature Heat Pipes for Cooling Microprocessor Chips (전자칩 냉각을 위한 소형 히트 파이프에 대한 실험적 연구)

  • Lee, S.M.;Kim, H.B.;Yang, J.S.;Lee, K.B.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.353-358
    • /
    • 2000
  • This paper presents the experimental investigation about miniature heat pipe for notebook PC. The focus of analysis is the operating temperature not to exceed $65^{\circ}C$ maximum allowable CPU surface temperature. Copper is used to heat pipe material and brass is wick material, and working fluid is selected to water. This cooling system is heat spreader method using a aluminum plate, since this method is most commonly used. According to the present study, heat for 3mm heat pipe, 8W, and for 4mm heat pipe, 10W, is found to power dissipation limit respectively, Soon after this investigation, sufficient long term life test should be followed.

  • PDF

Electric energy saving system with high speed response to load variation using power-factor correction (부하변동에 속응하는 역률개선형 전력절감시스템)

  • Kim, Tae-Soo;Kang, Hyung-Sik;Joo, Kyung-Don;Lyu, Seung-Heon;Koo, Kyung-Wan;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2388-2390
    • /
    • 2002
  • Small type electric energy saving system is proposed in this paper. The system improves power factor fastly according to load variation of each customer. Phases of voltage and current are detected as 1[ms] unit. Phase coincident algorithm is applied for power factor improvement. Capacitance is controlled for optimal power factor correction. Series reactor is controlled for harmonics reduction. Non-contact device is used for fast response and long life. Test result shows the effect of this system. Power factor of 40[W] electric fan is improved from 95[%] to 100[%]. In the case of electric light, power factor is improved from 82[%] to 100[%]. Response time for load variation is less than 1[ms].

  • PDF

Electric and Electrochemical Characteristic of PMMA-PEO Gel Electrolyte for Rechargeable Lithium Battery

  • 박수길;박종은;이홍기;이주성
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.10
    • /
    • pp.768-772
    • /
    • 1998
  • The new type polymer electrolyte composed of polymethyl methacrylate(PMMA) - polyethy leneoxide(PEO) contain $LiClO_4$ -EC/PC was developed for the weightless and long or life time of lithium polymer batery system with using polyaniline electrode. the gel type electrolytes were prepared by PMMA with PEO at different lithium salts in the glove box. The minimum thickness of PMMA-PEO gel electrolyte for the slim type is about(400~450$\mu\textrm{m}$. These gel electrolyte showed good compatibility with lithium electrode. The test cell Li/polymer electrolyte/polyaniline solid state cell which was prepared by different lithium salt was researched by electrochemical technique.

  • PDF

The performance evaluation of Stirling cryocooler for thermal imaging system (II) : Life test (열상장비용 스터링 극저온 냉동기 특성평가 (II) : 수명시험)

  • 홍용주;박성제;김효봉;김양훈;권영주
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.324-327
    • /
    • 2003
  • The needs for the cryocooler which has high reliability and long MTTF are increased in the military and commercial thermal imaging system The gas contamination wear, leakage of the working fluid, fatigue and etc. have the significant effects on the reliability and MTTF(Mean Time To Failure) or MTBF(Mean Time Between Failure) of the Stirling cryocooler. In the KIMM, the Stilting cryocooler with the linear compressor was released after the several performance tests were performed. This paper describe the experimental facility for the MTTF evaluation and some typical results of the Stilling cryocooler.

  • PDF

Lycorine: A Potential Broad-Spectrum Agent Against Crop Pathogenic Fungi

  • Shen, Jin-Wen;Ruan, Yuan;Ren, Wei;Ma, Bing-Ji;Wang, Xiao-Long;Zheng, Chun-Feng
    • Journal of Microbiology and Biotechnology
    • /
    • v.24 no.3
    • /
    • pp.354-358
    • /
    • 2014
  • A screening test showed that lycorine exhibited significant antifungal activity against 24 pathogenic crop fungi at concentrations of 500 ${\mu}g/ml$ and 100 ${\mu}g/ml$, respectively. Fusarium graminearum was selected for antifungal mechanism studies by observing its mycelial morphology and investigating the variations in its conductivity. In addition, the substance absorption and metabolism of F. graminearum were explored. The mechanism was revealed as being one by which lycorine destroyed the cellular membrane and further influenced substance absorption and cell metabolism.

A Study on the Weldability and the Fatigue Characteristics in Resistance pot Welding of 5182-O/6061-T6 Dissimilar Aluminum Alloy Sheets (이종 AI합금의 저항점용접부 용접성과 피로특성에 관한 연구)

  • 박진철;정원욱;강성수
    • Journal of Welding and Joining
    • /
    • v.17 no.2
    • /
    • pp.44-52
    • /
    • 1999
  • This study deals with spot weld ability of dissimilar aluminum alloy sheets in order to take advantage of its lightweight and strength. The paper also shows the relationship between weld elements(i.e. current, welding time and tip force) and weld quality on the resistance spot weld part of the same and dissimilar Al alloy. The conclusions are: (1) Because of excessive tip force, deep indentation remained at the Al 5182 side which is lower stiffness at the dissimilar Al alloy. (2) Weld quality (i.e. tensile shear strength) of dissimilar Al alloy is superior to that of the same Al 6061 alloy. (3) As long cycles, fatigue life of spot weld specimen on dissimilar Al alloy sheets was better than that of the same Al alloy.

  • PDF

A Brief Review on Variables and Test Priorities of Photovoltaic Module Life Expectancy

  • Padi, Siva Parvathi;Chowdhury, Sanchari;Zahid, Muhammad Aleem;Kim, Jaeun;Cho, Eun-Chel;Yi, Junsin
    • Current Photovoltaic Research
    • /
    • v.9 no.2
    • /
    • pp.36-44
    • /
    • 2021
  • To endorse the reliability and durability of the solar photovoltaic (PV) device several tests were conducted before exposing to the outdoor field in a non-ideal condition. The PV module has high probability that intend to perform adequately for 30 years under operating conditions. To evaluate the long term performance of the PV module in diversified terrestrial conditions, one should use the outdoor performance data. However, no one wants to wait for 25 years to determine the module reliability. The accelerating stress tests performing in the laboratory by mimicking different field conditions are thus important to understand the performance of a PV module. In this review, we will discuss briefly about different accelerating stress types, levels and prioritization that are used to evaluate the PV module reliability and durability before using them in real field.