• Title/Summary/Keyword: Long Life Test

Search Result 611, Processing Time 0.026 seconds

Life Evaluation of Long-time Used 1Cr-0.5Mo Main Steam Pipe (장기사용된 1Cr-0.5Mo 주증기관의 수명평가)

  • 백수곤;홍성인
    • Journal of Welding and Joining
    • /
    • v.16 no.1
    • /
    • pp.70-76
    • /
    • 1998
  • Most fossil power plants and many critical components will be approaching the end of their nominal design life. At the same time, utilities are finding it economically attractive to extend the use of these plants for several more years, Especially Main steam pipe that operated under high temperature and pressure, often under the more severe operating conditions associated with cycling duty, is most important pipe system and critical component in fossil power plant. To extend the viability of older pipe system and to improve the operation and maintenance reliability, some technologies of precise diagnosis and life management have evolved out of the necessity. The purpose of this study is to descrive the related technologies and show the example of one power plants. The purpose of this study is to descrive the related technologies and show the example of one power plants. The stress analysis was done using ANSYS FEM Code. The branch area from main steam to turbine was the high stressed zone. To evaluate the degradation of the pipe material, replica, visual check, magnetic test, hardness test were done at the welding spot. The degradation level of welding point was E/F, so the remaining life of the welded area was about 0-25%.

  • PDF

Considerations on the Long-term Reliability of On-line Partial Discharge Ceramic Sensor for Thermal Power Generators and its Demonstration in the Field

  • Sun, Jong-Ho;Youn, Young-Woo;Hwang, Don-Ha;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.103-108
    • /
    • 2012
  • The present study describes the considerations on the long-term reliability of the on-line partial discharge (PD) ceramic sensor for thermal power generators. Voltage acceleration aging tests were carried out under continuous and impulsive thermal aging at more than $100^{\circ}C$, considering the practical service environment. Experimental results show that the sensors have a life that could last for more than 100 years, excellent dielectric characteristics, and insulation strength. In addition, the ceramic on-line PD sensors were installed in a thermal power generator in Korea for demonstration. The results of the PD calibration and test voltage application prove that the on-line ceramic sensors have satisfactory performances for on-line PD measurement.

Men's Role Conflicts in Dual-Earner Family (맞벌이 가족 남서의 역할갈등에 관한연구)

  • 김태현
    • Journal of Families and Better Life
    • /
    • v.16 no.1
    • /
    • pp.81-94
    • /
    • 1998
  • The purpose of this study is to examine men's role conflicts of dual-earner family based on man's role type. Man's role type is composed of man's sex role attitude and family-role performance and categorized in four types such as traditionalism type neo-traditionalism type equalitarianism type and inconsistancy type. The test analysis can be summarized as follows; First test analysis can be summarized as follows; role performance and man's role conflict as working hours is long wife's role requirement is high family-role conflict as working hours is long wife's role requirement is high family-role is not commit man's role conflict directly affected. In addition indirect affect through family-role performance shows that man's role conflict level is low as level of income is high level of income difference between man and wife is low child is younger and intent to modern sex-role attitude. Second looking into the difference role conflict to man's role type it shows that equalita ianism type's role conflict is low and man's role conflict in traditionalism and neo-traditonalism types is high.

  • PDF

A Study on the Development of Capacitor Exchange Type GDU of Propulsion Control Device of Electric Railway Vehicle Capable of Life Diagnosis (수명진단이 가능한 전기철도차량 추진제어장치의 커패시터 교환 형 GDU 개발에 관한 연구)

  • Kim, Sung Joon;Chae, Eun Kyung;Kang, Jeong Won
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.7
    • /
    • pp.475-484
    • /
    • 2018
  • The propulsion control device of an electric railway vehicle is a key main component corresponding to an engine of an automobile, and a device for controlling this is a device called a GDU (Gate Drive Unit). Also, when the frequency of failure of the propulsion control system was analyzed, the nonconformity ratio of GDU was the highest. GDU was not able to access core technologies due to the introduction of foreign products, and there were general problems with overall maintenance activities due to discontinuation of GDU of the manufacturer. The GDU has reached the end of its life with 23 to 14 years of long-term use.In order to solve these problems, this study was designed to identify the proper life span by analyzing compatible GDU's acquisition and failure, and to improve the existing system of maintenance focusing on health inspection. Maintenance of the components with a short life span compared to the entire service life is essential. Most foreign parts introduced at the beginning of the construction are not replaced due to technical problems or long-term operation. However, due to the characteristics of railway vehicles with a long life span of more than 25 years, it is necessary to maintain them for a long period of time. The study should be more concrete and empirical. The replacement type GDU of capacitors was able to easily measure the life of the capacitance by removing the capacitor modules, measure the life span of each unit test, and accurately perform preventive maintenance of the capacitor.

Study about gene flow and stability assessment in GM rice (Oryza sativa L.)

  • Kim, Jun-Hoi;Kim, Kyung-Min
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.136-136
    • /
    • 2017
  • In agriculture, the rice is the one of important things. Many farmers and scientists have long tried to increase the yield of rice. So many technologies have been developed these days. One type of technology has given rise to a host of concerns and questions, namely Genetically Modified Organisms (GMOs). The increasing cultivation of GM crops has raised a wide range of concerns with respect to food safety, environmental effects and socio-economic issues and now commercially planted on about 100 million hectares in some 22 developed and developing countries. The scientific evidence concerning the environmental and health impacts of GMOs is still emerging, but so far there is no conclusive information on the definitive negative impacts of GMOs on health or the environment. Nevertheless, public perceptions about GMOs in food and agriculture are divided with a tendency toward avoiding GM food and products in many developed and developing countries. Also Korea is one of that country and is not allow the GMOs now. So I studied whether these GMOs are actually dangerous for environment and whether there are differences in cultivar characteristics such as germination test with TTC tetrazolium, germination test in frozen soil and gene-flow test with glufosinate and strip-bar test. With these experiments, we evaluated the agricultural safety of GM rice and to identify and assess environmental risks.

  • PDF

Analysis of Maximum Generating Power Drop of PV Module Under the Continuous Artificial Light Irradiation Test Condition (연속 광조사 조건에서의 태양전지모듈의 연간 최대출력 저하율 변화 예측 분석)

  • Kim, Kyungsoo;Yun, Jaeho
    • Current Photovoltaic Research
    • /
    • v.6 no.3
    • /
    • pp.69-73
    • /
    • 2018
  • PV system is consisted with PV module, inverter and BOS(balance of system). To have robustic operation more than 20 years, the expected and guaranteed durability and reliability of products should be met. Almost components of PV system are qualified through IEC standards at test laboratory. But the qualification certificate of product does not ensure long-term nondefective operation. PV module's expected life time is nowadays more than 20 years and annual maximum power degradation ratio would be less than -1%. But the power degradation ratio is basically based on real data more than several years' record. Developing test method for ensuring annual maximum power degradation ratio is very need because there are many new products every month with new materials. In this paper, we have suggested new test method under continuous artificial light irradiation test condition for analyze expected maximum power drop ratio.

Influences of Daily Life Posture Habits and Work-related Factors in Musculoskeletal Subjective Symptoms among Hospital Employees (병원 의료종사자의 생활습관자세와 업무특성이 근골격계 자각증상에 미치는 영향)

  • Park, Mijeong;Lee, Eun-young
    • Journal of muscle and joint health
    • /
    • v.23 no.2
    • /
    • pp.125-137
    • /
    • 2016
  • Purpose: The purpose of this study was to identify the influences of hospital employees' daily life posture habits and work-related factors upon musculoskeletal subjective symptoms. Methods: This study was a descriptive survey study. Data were collected using structured a self-report questionnaire between April 1 and May 31, 2015. One hundred and ninety two employees were recruited in three hospitals. The collected data were analyzed using descriptive statistics, ${\chi}^2$ test, t-test, and binomial logistic regression. Results: The habit of leaning on one side and the habit of bending the back in an improper posture are key postures based on lifestyle affecting musculoskeletal subjective symptoms in neck, shoulders, arms, waist, and legs. Labours accompanying repeated arm movements for a long time are key work-related risk factors affecting musculoskeletal subjective symptoms in arms. Conclusion: The results of this study confirmed that, to prevent musculoskeletal diseases, it is necessary to identify and mediate personal factors like daily life posture habits as well as work-related risk factors. They may be utilized as basic materials for education of musculoskeletal health promotion and development of life guidance programs.

Development of Accelerated Life Test Method for Constant Electrical Potential Electrolysis Gas Sensor (정전위 전해식 가스센서의 가속수명시험법 개발)

  • Yang, Il Young;Kang, Jun Gu;Yu, Sang Woo;Oh, Geun Tae;Na, Yoon Gyoon
    • Journal of Applied Reliability
    • /
    • v.16 no.3
    • /
    • pp.180-191
    • /
    • 2016
  • Purpose: The purpose of this study was to develop the accelerated life test method for Constant Electrical Potential Electrolysis gas sensor (CEPE gas sensor). Methods: The parts and modules of CEPE gas sensor were analyzed by using Reliability Block Diagram (RBD). Failure Mode and Effect Analysis (FMEA) and Quality Function Deployment (QFD) methods were performed for each part to determine the most affecting stress factor in its life cycle. The long term testing was conducted at three different dry heat levels and the acceleration factor was developed by using Arrhenius relationship. Conclusion: The acceleration factor for CEPE gas sensor was developed by using FMEA, QFD, and statistical analysis for its failure data. Also qualification tests were designed to meet the target life.

The Effects of Sochongryong-tang on Pulmonary Function and Quality-of-Life in Asthmatic Patients (소청용탕이 기관지천식 환자의 폐기능과 삶의 질에 미치는 영향)

  • 허태석;황우석;주창엽;정희재;이형구;정승기
    • The Journal of Korean Medicine
    • /
    • v.22 no.4
    • /
    • pp.131-141
    • /
    • 2001
  • Objectives : Asthma is a chronic inflammatory disorder in which the airway smooth muscle undergoes exaggerated constriction and is abnormally responsive to external stimuli and clinically manifests dyspnea, cough, and wheezing. Recently in Korea, the number of asthma patients has tended to increase as air pollution increases and new allergens appear. This study aimed to identify the therapeutic effects of Sochongryong-tang, which has been used on asthmatic patients in Oriental Medicine for a long time. Methods : We studied 10 asthmatic patients who had visited the Division of Respiratory System, Department of Internal Medicine of Kyunghee Oriental Medical Center from February 1, 2001 to June 30, 2001, which examined the patients by the pulmonary function test (PFT) and Quality of Life Questionnaire for adult Korean Asthmatics (QLQAKA) before and after taking Sochongryong-tang for two weeks. The data was analyzed using paired t-test. Results : After treatment with Sochongryong-tang for two weeks, FEV 1.0 showed a significant increase of 14.2%, FVC a significant increase of 9.3% and PEFR a significant increase of 16.2% in results of patients examined asthmatic by PFT. In the results of QLQAKA, the mean of scores increased significantly over 0.5 points in total score, symptom domain, emotion domain, and environmental domain. Conclusions : This study shows that Sochongryong-tang has the effect of improvements of pulmonary function and quality of life in asthmatic patients.

  • PDF

Application of hot rolling oil lubrication on RM stands at Pohang Hot Rolling Mill No.2 (포항2열연 조압연스탠드(RM) 유압연시스템의 개발과 적용)

  • 김철희;조준길;유문석;한영환
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.161-166
    • /
    • 1997
  • Application of hot roiling oil lubrication technology was broadened to the field of RM stands of Hot Rolling Mill at Pohang works. The primary object was to improve the quality of the strip sttrface and the rolls by oil lubrication in hot rolling process. Prior to the actual field application preliminary test was conducted to evaluate the effect of hot rolling oil lubrication at RM stands. From the test, it has been found that the use of oil lubrication tends to prevent the progression of the heat cracks and thereby increases the quality of the strip surface and the wear life of the rolls. New hot rolling oil lubrication system was applied to the RM stands VSB, R1, R2, R3, R4 and edger rolls. With the introduction of a rolling lubricant, the quality of the strip surface and rolls was improved and overall roll dressing has decreased. Also there has been a improvement of productivity from the long roll life.

  • PDF