• Title/Summary/Keyword: Long Gap

Search Result 594, Processing Time 0.024 seconds

Analysis and Evaluation of Reduction of Impact Force in a Coupler when a Long Freight Car Brakes (장대화물열차 제동 시 연결기에 발생하는 충격력 해석 및 분석)

  • Lee, Jeong Jun;Koo, Jeong Seo;Cho, Byung Jin;Na, Hee Seung;Mun, Hyung Seok
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.1
    • /
    • pp.130-137
    • /
    • 2018
  • In long freight trains, there is a brake time delay in the neighboring freight cars that causes damage and fractures of couplers, especially the knuckle of them. If there is a problem for couplers in the cars, this could cause a derailment and lead to damage of human life and property damage. In this study, maximum forces on the couplers are studied when a long freight car brakes, with brake delay time and coupler gap. We have made a dynamic model of 50 freight cars and couplers, applying contact between couplers and a characteristic curve for expressing force and displacement of buffers with SIMPACK, a multi-body dynamics program. We use EN 14531-2 from the British Standards Institution, a standard of freight car brakes for the verification of the dynamic model. We also use a simplified method to analyze the dynamic model of 50 freight cars. With changing coupler gap and brake delay time, we do comparative analysis with AAR M-201 from the Association of American Railroads, a standard of AAR couplers. From this result, we find that the standard on fatigue limit is satisfied, such that the brake delay time is within 0.06 second if the coupler gap of the AAR coupler is within 20 millimeters.

Design of Erase Waveform for Stabilizing Reset Discharge in Mid-gap AC Plasma Display Panels (중간간격을 갖는 교류형 플라즈마 디스플레이 표시기의 소거파형 연구)

  • Yoon, Su-Han;Seo, Jeong-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.993-998
    • /
    • 2011
  • In this paper we suggest new criteria for the classification of the electrode gap between common and scan electrodes. The electrode gap is categorized as a short, middle, and long gap according to the criteria. Among these structures, we focus on the erase waveform of a mid-gap structure. we report an unstable discharge arising from the erase ramp period in a mid-gap structure. Based on the Vt close curve, we analyze the unstable discharge at various conditions. Our analysis reveals that the unstable discharge is ignited between surface electrodes and caused by un-erased wall charges accumulated on the outer edges of electrodes. By reducing the voltage level of the last sustain pulse, the problem is solved.

Asset Price Volatility and Macroeconomic Risk in China (资产价格波动对中国宏观经济风险的影响)

  • Jishi, Piao;Mengjiao, Liu
    • Analyses & Alternatives
    • /
    • v.3 no.1
    • /
    • pp.135-157
    • /
    • 2019
  • The linkages between asset prices and macroeconomic outcomes are long-standing issue to both economists and monetary authorities. This paper explores the impact of asset prices on output and price in China. It focuses on the impacts of asset prices on the low quantiles of GDP gap and high quantiles of price gaprespectively. The main findings are the following: the influence of stock price gap, stock returns, and money growth on the different quantile of GDP gap and price gap are noticeable different, and there are significant impacts on the left tail of GDP gap distribution and on the right tail of price gap distribution. This implies that the results coming from simple regression will underestimate the economic risk imposed by asset price volatility. Moreover, these results also provide the caveat that one should cautiously distinguish the meaning of asset price gap and asset price growth rate and use them, through their contents are similar in some sense. One implication for monetarypolicy is that authority should interpret the relationship between asset prices and macro-economy in wider perspectives, and make the policy decision taking the impacts of asset prices on the tails of economy.

  • PDF

A Novel High Precision Electromagnetic Suspension for Long-Stroke Movement and Its Performance Evaluation

  • Lee, Ki-Chang;Moon, Seokhwan;Ha, Hyunuk;Park, Byoung-Gun;Kim, Ji-Won;Baek, Jun-Young;Lee, Min-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.514-522
    • /
    • 2014
  • A new type of high precision electromagnetic suspension (EMS) which can support heavy tray along long stroke rail is proposed in this paper. Compared with the conventional EMS, the suggested moving-core typed EMS has the levitation electromagnets (EMs) on the fixed rail. This scheme has high load capability caused by iron-core and enables simple tray structure. Also it does not have precision degradation caused by heat generation from EMs, which is a drawback of conventional EMS. With these merits, the proposed EMS can be an optimal contactless linear bearing in next generation flat panel display (FPD) manufacturing process if the ability of long stroke movement is proved. So a special Section Switching Algorithm (SSA) is derived from the resultant force and moment equations of the levitated tray which enables long stroke movement of the tray. In order to verify the feasibility of the suggested SSA, a simple test-setup of the EMS with 2 Section-changes is made up and servo-controlled in the simulation and experiment. The simulation shows the perfect changeover the EMs, and the experiment shows overall control performance of under ${\pm}40{\mu}m$ gap deviations. These results reveal that the newly suggested contactless linear bearing can simultaneously achieve high load capability and precision gap control as well as long stroke.

Embodiment of Low Operating Voltage in Positive Column AC-PDPs

  • Kim, Hyun;Tae, Heung-Sik;Chien, Sung-Il
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.95-98
    • /
    • 2003
  • The positive column discharge characteristics in the long gap (440 ${\mu}m$) are investigated based on the voltage distribution among three electrodes. In particular, the effects of the amplitude and width of the short pulse applied to the address electrode on the positive column discharge characteristics are examined intensively. By proper controlling of the amplitude and width of the address short pulse, it is found that the positive column discharge in the long gap is well constructed. As a result, under the stable static voltage margin condition, the firing and sustaining voltages are as low as those of conventional short gap(60 ${\mu}m$) discharge($V _f=220V$, $V_s=150V$) and the color purity is improved. Moreover, the luminous efficiency increases up to 60% in comparison with the conventional case.

  • PDF

Effect of Self-Erase Discharge on the Luminous Efficacy of Long Gap AC PDPs

  • Kim, Tae-Jun;Jung, Jae-Chul;Jung, Hae-Yoon;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.585-588
    • /
    • 2007
  • We studied the effect of self-erase discharge on the luminous efficacy of ac PDPs. We observed through discharge current analysis to confirm that the selferase discharge occurred mainly between sustain cathode and address electrode, which have an influence on the luminous efficacy. The amount and timing of the self-erase discharge was varied to observe its effect on the luminous efficacy. It has been found that the luminous efficacy could be improved by the self-erase discharge when it is adjusted to occur right before the main discharge in the small gap structure. In the long gap structure, on the contrary, the luminous efficacy could be increased when the self-erase discharge is suppressed. Also, various waveforms to control self-erase discharge are suggested and tested in the panel experiments.

  • PDF

Esophageal Replacement with Transhiatal Gastric Transposition In the Long Gap Esophageal Atresia - Report of Two Cases - (원간격결손 식도페쇄증에서 경열공적 위전위법을 이용한 식도재건술)

  • Han, Seok-Joo;Kim, Sung-Do;Kim, Choong-Sai;Oh, Jung-Tak;Hwang, Eui-Ho
    • Advances in pediatric surgery
    • /
    • v.3 no.2
    • /
    • pp.152-159
    • /
    • 1997
  • Transhiatal gastric transposition was performed in two case of long gap esophageal atresia without tracheoesophageal fistula. The patients were a 12 months old female and an 18 months old male. Stamm type gastrostomies were performed at other hospitals in both cases. The stomach was mobilized preserving the right gastric artery, the right gastroepiploic artery and spleen. A portion of the proximal and the distal esophageal segment were excised by transcervical and transhiatal route, respectively. The mobilized stomach was pulled up to the neck through the esophageal hiatus and posterior mediastinum. The esophagogastrostomy, the only one anastomosis of this procedure, was performed in the neck. There was no clinical evidence of anastomotic leakage, stricture, regurgitation, difficulty of gastric emptying, hoarseness or respiratory problem. Transhiatal gastric transposition seems to be a safe and easy alternative surgical procedure for esophageal replacement in long gap esophageal atresia.

  • PDF

Customer Churn Identifying Model Based on Dual Customer Value Gap

  • Hou, Lun;Tang, Xiaowo
    • Management Science and Financial Engineering
    • /
    • v.16 no.2
    • /
    • pp.17-27
    • /
    • 2010
  • The customer churn and the forecast of customer churn have been important research topics for a long time in the academic domain of customer relationship management. The customer value is studied to construct a gap model based on dual customer values; a basic description of customer value is given, then the gaps between products and services in different periods for the customers and companies are analyzed. The main factors that influence the perceived customer value are analyzed to define the "recognized value gap" and a gap model for the dual customer value is constructed. Based on the dual customer gap a con-ceptual model to determine potential churn customers is proposed in the paper.

Discharge Characteristics of Surface Discharge Type FFL for LCD Backlighting (LCD 백라이트용 면방전형 FFL의 방전 특성)

  • Lim, M.S.;Yun, S.H.;Shin, Y.S.;Jung, D.Y.;Kwon, S.S.;Lim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1786-1788
    • /
    • 1999
  • In this paper, we studied Surface Discharge Type Flat Fluorescent Lamp with High Luminance for LCD Backlighting, Liquid Crystal display(LCDs) demand the use of fluorescent lamp as the backlighting source. This lamp is Surface Discharge Type structure with a pair of Sodalime glass, insulator layer, phosphor layer, and Xe gas gap. In spite of its simple structure, the lamp has uniform and stable discharge over entire volume. Till now, we measured the current-voltage(V-I), Firing Voltage, Sustain Voltage for 0.5mm, 1mm electrode gap. In experiment result, long gap cell structure cause high firing voltage. The rising in firing voltage in long gap structure could not be explained by paschen's law because of non-uniform electric field.

  • PDF

Comparisons Fitness in Implant Abutment between Gas Soldering and Laser Welding

  • Cho, Mi-Hyang;Nam, Shin-Eun
    • International Journal of Clinical Preventive Dentistry
    • /
    • v.14 no.4
    • /
    • pp.247-255
    • /
    • 2018
  • Objective: Osseointegration is essential process for successful implants and effects to implant in long term, therefore, passive fitness of good prosthesis is necessary. To make a good prosthesis, at first it should be done a sectioned casting and then joined method of sectioned casting body is recommended. Methods: In this study, to provide the fundamental data on stable connection method for successful implants, the author tested fitness of casting body, and compared difference between gas soldering technique and laser welding technique. Results: In fitness test of 2 abutment (test A, C), gas soldering group's fitness in the opposite part of connection was worse than laser welding group. In fitness test of 3 abutment (test B, D), gap distance was increased both in gas soldering technique and laser welding technique. Gap distance at the connecting part and the opposite part of the abutment in gas soldering technique was worse than laser welding technique and the more additional abutment, the worse gap distance in gas soldering technique. In fitness test of 3 abutment (test B, D), there's little variation in No. 2 abutment when connecting soldering process was done and there's little influence on already soldered connection part when the additional soldering connection was done. Conclusion: On weak loading condition and the part which is needed an accuracy, laser welding technique is more effective and on long-span prosthesis and frequent chewing loading part, laser welding technique is recommended first and applying additional gas soldering technique would be better for making much more successful prosthesis.