• Title/Summary/Keyword: Lock-on

Search Result 884, Processing Time 0.026 seconds

A Dynamic Prefetch Filtering Schemes to Enhance Usefulness Of Cache Memory (캐시 메모리의 유용성을 높이는 동적 선인출 필터링 기법)

  • Chon Young-Suk;Lee Byung-Kwon;Lee Chun-Hee;Kim Suk-Il;Jeon Joong-Nam
    • The KIPS Transactions:PartA
    • /
    • v.13A no.2 s.99
    • /
    • pp.123-136
    • /
    • 2006
  • The prefetching technique is an effective way to reduce the latency caused memory access. However, excessively aggressive prefetch not only leads to cache pollution so as to cancel out the benefits of prefetch but also increase bus traffic leading to overall performance degradation. In this thesis, a prefetch filtering scheme is proposed which dynamically decides whether to commence prefetching by referring a filtering table to reduce the cache pollution due to unnecessary prefetches In this thesis, First, prefetch hashing table 1bitSC filtering scheme(PHT1bSC) has been shown to analyze the lock problem of the conventional scheme, this scheme such as conventional scheme used to be N:1 mapping, but it has the two state to 1bit value of each entries. A complete block address table filtering scheme(CBAT) has been introduced to be used as a reference for the comparative study. A prefetch block address lookup table scheme(PBALT) has been proposed as the main idea of this paper which exhibits the most exact filtering performance. This scheme has a length of the table the same as the PHT1bSC scheme, the contents of each entry have the fields the same as CBAT scheme recently, never referenced data block address has been 1:1 mapping a entry of the filter table. On commonly used prefetch schemes and general benchmarks and multimedia programs simulates change cache parameters. The PBALT scheme compared with no filtering has shown enhanced the greatest 22%, the cache miss ratio has been decreased by 7.9% by virtue of enhanced filtering accuracy compared with conventional PHT2bSC. The MADT of the proposed PBALT scheme has been decreased by 6.1% compared with conventional schemes to reduce the total execution time.

Development of Devices for Improving the Reducibility of Patient Positioning on a Breast Board (Breast Board를 이용한 방사선치료에서 환자 위치 재현성 향상 방안에 대한 연구)

  • Huh Soon Nyung;Cho Woong;Park Yang Kyun;Ha Sung Whan
    • Radiation Oncology Journal
    • /
    • v.23 no.2
    • /
    • pp.123-130
    • /
    • 2005
  • Purpose: We wanted to improve the setup reproducibility of breast cancer patients when utilizing a commercially available breast board for radiation therapy. The breast board was modified by using a new head rest and 2 types of board fixation devices. Materials and Methods: A conventional head/neck rest was modified to be positioned in various slots of the breast board, and it was fabricated 1 cm thinner to provide more comfort to a patient when the patient's neck was rotated. This rest improves the uncertainty of the daily setup. Also, the sagging problems at the left and right sides became negligible with the two types of board fixation devices: (1) the stair type, and (2) the arm type. The first device consists of an upper/lower holder with 4 stair-types of grooves and 4 rectangular Inserts. In order to cover the whole range of vertical setup of the breast board, 4 rectangular inserts were needed, and each covered 10 steps. The arm-type fixation device was also fabricated and attached to the breast board, It had two aluminum bars that were fixed by utilizing a lock-type of screw. These devises were evaluated with two volunteers in order to prove the effectiveness of the improved setup accuracy. Results; The developed cranio-caudal fixation device demonstrated that it could reduce the cranio-caudal error by nearly $55\%$ compared to the old device. As for left-and-right inclination, the stair-type and arm-type fixation devices can reduce the relative inclination by nearly $80\%$ and $90\%$, respectively, compared to the breast board without the fixation device. Conclusion: It was verified that the developed devices were effective for positioning the patients and for avoiding inclination of the breast board.

Actual Conditions of Burglaries and Analysis on Residential Invasion Burglaries in Daegu Area (강도 범죄의 실태 및 대구 지역 침입 강도 범죄 분석)

  • Lee, Sang-Ho;Kwak, Jyung-Sik
    • Journal of forensic and investigative science
    • /
    • v.2 no.2
    • /
    • pp.5-20
    • /
    • 2007
  • During the period from 2001 to 2005, 29,892 burglaries took place in Korea with the approximate average annual number - 5,978 cases. This study was conducted to analyze the reported burglaries and the result was summarized as follows. There were 8,605 residential invasion burglaries (28.8%) as the most frequent characteristic pattern. The exit was used as the most frequent invasion route for 4,031 invasion burglaries (64.3%), and an unlocked exit door or window was used as the most frequent invasion method for 2,462 invasion burglaries (28.6%). The hours just after midnight (between 00:00 and 04:00) were the most frequent time for invasion burglary to occur. Also, 5,652 burglaries occurred on Wednesday which was twice higher than on Sunday (2,988 burglaries). It was shown that the number of persons injured during burglaries were 260 deaths and 10,610 injuries. The places of the highest occurrence were the street with 10,183 burglaries (34%) and then residential place with 7,527 burglaries (approximately 25%). One-man burglary was the highest complicity: 15,012 offenders (56.1%). The knife was used as the most frequent instrument for 6,498 burglaries (24,3%) what is rare, while no criminal tool or instrument was used for 15,631 burglaries (58.4). During the period from 2001 to 2006, 1,506 burglaries occurred in Daegu and the average annual number was 251 burglaries. Among those,515 residential invasion burglaries (34.2%) took place and the average annual number was approximately 86 cases. The hours just after midnight (between 00:00 and 04:00) were the most frequent time for invasion burglary to occur (194 cases, 37.7%), the place of the highest invasion occurrence was the residential place (259 cases, 50.3%), and the exit was used as the most frequent invasion route (87 cases, 37.7%). An unlocked exit door or window was the most frequent invasion method (65 cases, 25.1%). In addition, pretending to be a delivery man, visitor or following the victim methods were used for 26 burglaries (10%). It is apparent that personal preventive measures against crimes, as well as governmental and social measures, play an important role in preventing burglaries. In particular, based on the analyzed result that an unlocked window or exit door was most frequently used for reported burglaries, it seems that there is a lack of understanding of crime prevention while little effort has been made to prevent crimes. Although everyone knows that locking a door is one of the basic measures to prevent crimes, many people tend to pay little attention to lock a door properly so burglary takes place. This study, therefore, is intended to encourage people to pay more careful attention to crime prevention, in order to help reduce the probability of burglary. With the recent improvement in social understanding of scientific crime investigation, a wide variety of police professions, including crime analysts, crime victim police counselors and coroners, have been prepared to develop the scientific crime investigation and crime analysis. In addition, it is hoped that further this study will contribute to encourage studies on crime prevention to be carried out in the future.

  • PDF

Effect of Carbon Couch Side Rail and Vac-lok In case of Lung RPO irradiation (Lung RPO 선량전달시, Carbon Couch Side Rail과 Vac-lok이 미치는 영향)

  • Kim, Seok Min;Gwak, Geun Tak;Lee, Seung Hun;Kim, Jung Soo;Kwon, Hyoung Cheol;Kim, Yang Su;Lee, Sun Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.27-34
    • /
    • 2018
  • Purpose : To evaluate the effect of carbon couch side rail and vacuum immobilization device in case of lung RPO irradiation. Materials and Methods : The 10, 20, 30 mm thickness of vac-lok's right side were obtained. To measure of doses, glass dosimeters were used and measured reference point is left lung center at the phantom. A, B, C, and D points are left, right, down, and up directions based on the center point. In the state of Side-Rail-Out, place the without vac-lok, with the thickness of 10, 20, and 30 mm vac-lok. After the glass dosimeters was inserted in center, A, B, C, and D points, 100 MU of 6 MV X-ray were irradiated to the referenced center point in the condition of $10{\times}10cm^2$ field size, SAD 100 cm, gantry angle 225, 300 MU/min dose rate. Five measurements were made for each point. In the state of Side-Rail-In, five measurement were made for each point under the same conditions. The average is measured on each of the five Side-Rail-Out and Side-Rail-In measurements. Results : In the presence of side rail, the dose reduction ratio was -11.8 %, -12.3 %, -4.1 %, -12.3 %, -7.3 % for each A, B, C, and D points. In the state of Side-Rail-Out, the dose reduction ratio for the using 10 mm thickness of vac-lok was -0.9 % than without vac-lok. The dose reduction ratio for the using 20 mm thickness of vac-lok was -2.0 %, for the using 30 mm thickness of the vac-lok was -3.0 % than without vac-lok. In the state of Side-Rail-In, the dose reduction ratio for the using 10 mm thickness of vac-lok was -1.0 % than without vac-lok. The dose reduction ratio for the using 20 mm vac-lok was -2.1 %, for the using 30 mm vac-lok was -3.0 % than without vac-lok. Based on the value of no vac-lok dose in the Side-Rail-In state, The dose reduction ratios for the using 10 mm, 20 mm and 30 mm thickness of vac-loks In the Side-Rail-Out that the center point were -12.7 %, -13.7 %, -14.2 % and -12.8 %, -13.8 %, -14.5 % respectively at point A. The dose reduction ratios for the same conditions to the B point were -4.9 %, -6.1 %, -7.1 % and -13.4 %, -14.4 %, -15.5 % respectively at point C. The dose reduction ratios for the same conditions to the D point were -8.4 %, -9.0 %, -10.4 % respectively. Conclusion : The attenuation was caused by presence of side rails and thickness of vac-lok. Pay attention to these attenuation factors, making it a more effective radiation therapy.

  • PDF