• Title/Summary/Keyword: Locator

Search Result 201, Processing Time 0.027 seconds

Removable partial denture restoration using single implant supported with $Locator^{(R)}$ attachment in a crossed occlusion patient: a case report (다수치아를 상실한 엇갈린 교합 환자에서 임플란트와 $Locator^{(R)}$ attachment를 이용한 가철성 국소의치 증례)

  • Shin, Woon-Chul;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Lim, Hyun-Pil;Yun, Kwi-Dug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.2
    • /
    • pp.113-118
    • /
    • 2013
  • When losing many of the remaining teeth, the relation among them can be put into dynamically unfavorable situation. In the case that the patient without any incompatibilityto the denture, overdenture can be considered. Moreover, we can overcome the dynamical disadvantage, and improve the support, stability, and retention of the partial denture by using implant at the edentulous area. In this case, patient with crossed occlusion between few remaining teeth was treated with maxillary and mandibular partial denture. Single implant fixture was placed at the edentulous space, opposing to the maxillary teeth occluded, and $Locator^{(R)}$ attachment was connected. The patient's esthetic satisfaction was improved by ideally adjusting the tilted occlusal plane. Since the patient was satisfied both esthetically and functionally, and maintained stable during the clinical observation for 6 months after the treatment, we would like to report about it.

Effect of implant- and occlusal load location on stress distribution in Locator attachments of mandibular overdenture. A finite element study

  • Alvarez-Arenal, Angel;Gonzalez-Gonzalez, Ignacio;deLlanos-Lanchares, Hector;Martin-Fernandez, Elena;Brizuela-Velasco, Aritza;Ellacuria-Echebarria, Joseba
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.5
    • /
    • pp.371-380
    • /
    • 2017
  • PURPOSE. The aim of this study is to evaluate and compare the stress distribution in Locator attachments in mandibular two-implant overdentures according to implant locations and different loading conditions. MATERIALS AND METHODS. Four three-dimensional finite element models were created, simulating two osseointegrated implants in the mandible to support two Locator attachments and an overdenture. The models simulated an overdenture with implants located in the position of the level of lateral incisors, canines, second premolars, and crossed implant. A 150 N vertical unilateral and bilateral load was applied at different locations and 40 N was also applied when combined with anterior load at the midline. Data for von Mises stresses in the abutment (matrix) of the attachment and the plastic insert (patrix) of the attachment were produced numerically, color-coded, and compared between the models for attachments and loading conditions. RESULTS. Regardless of the load, the greatest stress values were recorded in the overdenture attachments with implants at lateral incisor locations. In all models and load conditions, the attachment abutment (matrix) withstood a much greater stress than the insert plastic (patrix). Regardless of the model, when a unilateral load was applied, the load side Locator attachments recorded a much higher stress compared to the contralateral side. However, with load bilateral posterior alone or combined at midline load, the stress distribution was more symmetrical. The stress is distributed primarily in the occlusal and lateral surface of the insert plastic patrix and threadless area of the abutment (matrix). CONCLUSION. The overdenture model with lateral incisor level implants is the worst design in terms of biomechanical environment for the attachment components. The bilateral load in general favors a more uniform stress distribution in both attachments compared to a much greater stress registered with unilateral load in the load side attachments. Regardless of the implant positions and the occlusal load application site, the stress transferred to the insert plastic is much lower than that registered in the abutment.

Implant-assisted removable partial denture using milled bar and Locator in partially edentulous maxilla: A case report (상악 부분 무치악 환자에서 Milled Bar와 Locator를 이용한 임플란트 융합 국소의치수복 증례)

  • Kim, Ji-Hyun;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo;Lee, Hyeon-Jong;Lee, So-Hyoun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.2
    • /
    • pp.137-144
    • /
    • 2020
  • Implant-fixed prostheses and removable partial dentures are widely used as a traditional treatment method for partially edentulous patients who have lost multiple teeth. Recently, there has been increasing interest in implant-assisted removable partial denture (IARPD), which additionally obtains retention and support using a small number of implants. The IARPDs have higher retention, stability, and aesthetics than conventional removable dentures. It also has the effect of reducing the cost as well as the burden of surgery by placing a small number of implants at the edentulous site. In this case, the patient with a partial edentulous state that has multiple numbers of tooth loss in maxilla initially planned to be treated with implant fixed prosthesis. However, the treatment plan was changed to IARPD using Bar and Locator due to several factors. The clinical results were satisfactory on the aspect of esthetic and masticatory function.

ONE-VISIT ROOT CANAL TREATMENT USING ELECTRICAL APEX LOCATOR IN A CEREBRAL PALSY PATIENT (전자근관장 측정기를 이용한 뇌성마비 환자의 재근관치료)

  • Park, Jin-Sung;Lee, Seung-Jong
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.3 no.2
    • /
    • pp.97-100
    • /
    • 2007
  • In patients with cerebral palsy, dental treatments, which require absolute patient's corporation, have many difficulties because of muscle spacity, involuntary muscle movements and spasm. Especially in endodontic treatments which very meticulous instrumentation is needed, these muscle discordances may lead to unexpected accidents such as tissue damage while filing, over-instrumentation and swallowing instruments. Also, taking radiographs for measuring canal length is often hindered by walking and movement disorders. This paper is to present a clinical case of one-visit root canal treatment using electrical apex locator under general anesthesia in a cerebral palsy patient.

  • PDF

The Decoding Algorithm of Binary BCH Codes using Symmetric Matrix (대칭행렬을 이용한 2원 BCH 부호의 복호알고리즘)

  • 염흥렬;이만영
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.14 no.4
    • /
    • pp.374-387
    • /
    • 1989
  • The decoding method of Binary BCH Codes using symmetric matrix is proposed in this paper. With this method, the error-locator-polynomial is composed by symmetric matrix which consists of the powers of the unknown X plus the synfromes as its elements. The symmetric matirx can also be represented in terms of the unknown X. But the each coefficients of the error-locator polynomial represents the matirx with the syndromes as its entries. By utilizing this proposed algorithm, the device for decoding circuit of the (63, 45) BCH Code for t=3 has been implemented for demonstration.

  • PDF

A BGP based Distributed Mapping System for Id/Loc split (Id/Loc split 를 위한 BGP 기반 매핑 시스템)

  • Angel, Mukankunga Bisamaza;Hong, Choong Seon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2010.11a
    • /
    • pp.1050-1052
    • /
    • 2010
  • Locator and Identifier Split is considered as the solution to the scalability problem Internet is facing today. The separation approach of Locator and Identifier requires a third party called mapping system. The mapping system enables the inter-domain routing between two different edge networks. The design of this third party has generated many proposals, among them one approach use Border Gateway Protocol (BGP) for effective mapping information updates distribution. In this paper, we take advantage of this approach by considering the scalability in term of mapping information storage. Our goal is to provide scalability in term of mapping information storage as well as effective mapping information updates distribution.

A Study on Automatic Switching System for Fault Locator (고장점 표정반 자동절체 시스템에 대한 연구)

  • Park, Yong-Bum;Lho, Young-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8927-8932
    • /
    • 2015
  • A directional feeding method at the railway transformer is applied for supplying the power to the electric railway substations, and the pre-installed facilities with common feeder are utilized in preparation for the failure of feeding system and in finding a fault location in case that the catenary failure occurs. However, it is some difficulty in finding the fault location since there is an interface problem with the facilities when the supplying power system operates. In this paper, Auto Fault Locator Transfer Drive System (ALTDS) is designed to search for the fault location efficiently, and the measuring data are obtained and compared with the KORAIL standards. Further, the ground connection test is accomplished 24 times as the verification method, and it is shown that the methodology provides better performance than the existing traditional one.

The accuracy of the frequency dependent type apex locator (주파수의존형 전자근관장측정기의 정확도에 관한 연구)

  • Park, Ju-Huun;Roh, Byoung-Duck;Lee, Seoung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.150-160
    • /
    • 1996
  • The present study was to evaluate the accuracy of the frequency dependent type apex locator, Root-ZX. The subjects included 505 root canals of 238 teeth treated by the Department of Conservative Dentistry, and 22 human premolars which were schduled to be extracted for the orthodontic reasons. The results were as follows ; 1. The working lengths determined by Root-ZX were compared with radiographic readings. Of the total 505 root canals, 66 % showed coincidence within ${\pm}0.5mm$ and the average readings of Root-ZX were $0.13mm{\pm}1.05$ longer than those of radiographic readings. 2. The length difference between the file tip determined by Root-ZX and the apical constriction in extracted teeth were measured. Of the total 24 root canals, 70.8 % showed coincidence within ${\pm}0.5mm$ and the average readings of Root-ZX were $0.12mm{\pm}0.50$beyond the apical constriction. 3. The vitality of the teeth did not show any statistical difference(p>0.05) in the accuracy of the Root-ZX readings. The presence of the periapical lesions, however, significantly lowered the percentage of ${\pm}0.5mm$ accuracy in Root-ZX measurements.(p<0.05). In the presence of periapical lesions, the percentage within ${\pm}0.5mm$ was significantly lower.

  • PDF