• Title/Summary/Keyword: Location Error

Search Result 1,239, Processing Time 0.033 seconds

Estimation of Disease Code Accuracy of National Medical Insurance Data and the Related Factors (의료보험자료 상병기호의 정확도 추정 및 관련 특성 분석 -법정전염병을 중심으로-)

  • Shin, Eui-Chul;Park, Yong-Mun;Park, Yong-Gyu;Kim, Byung-Sung;Park, Ki-Dong;Meng, Kwang-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.3 s.62
    • /
    • pp.471-480
    • /
    • 1998
  • This study was undertaken in order to estimate the accuracy of disease code of the Korean National Medical Insurance Data and disease the characteristics related to the accuracy. To accomplish these objectives, 2,431 cases coded as notifiable acute communicable diseases (NACD) were randomly selected from 1994 National Medical Insurance data file and family medicine specialists reviewed the medical records to confirm the diagnostic accuracy and investigate the related factors. Major findings obtained from this study are as follows : 1. The accuracy rate of disease code of NACD in National Medical Insurance data was very low, 10.1% (95% C.I. : 8.8-11.4). 2. The reasons of inaccuracy in disease code were 1) claiming process related administrative error by physician and non-physician personnel in medical institutions (41.0%), 2) input error of claims data by key punchers of National Medical Insurer (31.3%) and 3) diagnostic error by physicians (21.7%). 3. Characteristics significantly related with lowering the accuracy of disease code were location and level of the medical institutions in multiple logistic regression analysis. Medical institutions in Seoul showed lower accuracy than those in Kyonngi, and so did general hospitals, hospitals and clinics than tertiary hospitals. Physician related characteristics significantly lowering disease code accuracy of insurance data were sex, age group and specialty. Male physicians showed significantly lower accuracy than female physicians; thirties and fortieg age group also showed significantly lower accuracy than twenties, and so did general physicians and other specialists than internal medicine/pediatric specialists. This study strongly suggests that a series of policies like 1) establishment of peer review organization of National Medical Insurance data, 2) prompt nation-wide expansion of computerized claiming network of National Medical Insurance and 3) establishment and distribution of objective diagnostic criteria to physicians are necessary to set up a national disease surveillance system utilizing National Medical Insurance claims data.

  • PDF

Accuracy Analysis of Cadastral Control Points Surveying using VRS case by Jinju city parts (가상기지국을 활용한 지적기준점 관측 정확도 분석 -진주시 일원을 중심으로-)

  • Choi, Hyun;Kim, Kyu Cheol
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.4
    • /
    • pp.413-422
    • /
    • 2012
  • After development of GPS in the 1960's, the United States released SA(Selective Availability) in 2000 and then the GPS has become commercialized to the present. The result of repeatedly developed GPS observation, the GPS real-time observation methods is RTK which basically always needs two base stations and has a fault of the accuracy decreasing as the distance between a mobile station and a receiver is increasing. Because of these weakness, VRS method has come out. VRS(Virtual Reference Station) generates the imaginary point near mobile station from several observatory datum of GPS, sets the accurate location of mobile station, thus shows high reliability and mobility. Now, the cadastral datum point is used with azimuth, repetition, and graphical traversing method for traverse network. The result of measurement indicates many problems because of different accomplishment interval given point, restrictions on the length of the conductor, many errors on the observations. So, this study did comparative analysis of the cadastral datum points through VRS method by Continuously Operating Reference Station. Through the above comparative analysis, The comparative result between surveyed result with repetition method through total station observed Cadastral Control Points and surveyed result with VRS-RTK has shown that average error of x-axis is -0.08m, average error of y-axis, +0.07m and average distance error is +0.11m.

Evaluation Scheme of the GPS Positional Accuracy for Dynamic Bus Route Information using SMB(Single Buffering Method) (단일 버퍼링 기법을 이용한 동적 버스 노선 정보의 GPS 위치 정확도 평가 방안)

  • Park, Hong-Gi;Joo, Yong-Jin
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.6
    • /
    • pp.677-685
    • /
    • 2011
  • In order to enhance public transportation and to maintain information credibility, improvement of accuracy regarding route and positional information of public transport is very significant. There have been a variety of methods using GPS to measure accuracy of location-based services. However, the researches of evaluation regarding kinematic position of linear objects measured by vehicle/kinematic GPS are still insufficient. That's why our paper aims to suggest method of evaluation accuracy on a real-time bus route surveyed by GPS by SBM(Single Buffering Method). To make it come true, we compared the findings on the static and dynamic positioning by using PP(Point Positioning), DGPS and GPS/INS integrated systems and analyzed the accuracy and error effects among them, focusing on Anyang city. Consequently, we can find out that in case of P.P. comparing positioning accuracy between RTK DGPS and GPS/INS, both of them have survey result within a margin of error of 5m. More importantly, we can evaluate positional accuracy of each GPS system based on the work provision of a public survey such as error for P.P.(14.5m, 18.1m), DGPS(16.9m, 18.5m), and GPS/INS(18.4m, 18.5m). We are expecting that proposed method in our paper can be utilized in a wide range of categories such as feasibility testing of GPS field survey and high accuracy of positioning for Bus Information System.

Feature Matching using Variable Circular Template for Multi-resolution Image Registration (다중 해상도 영상 등록을 위한 가변 원형 템플릿을 이용한 특징 정합)

  • Ye, Chul-Soo
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.6_3
    • /
    • pp.1351-1367
    • /
    • 2018
  • Image registration is an essential process for image fusion, change detection and time series analysis using multi-sensor images. For this purpose, we need to detect accurately the difference of scale and rotation between the multi-sensor images with difference spatial resolution. In this paper, we propose a new feature matching method using variable circular template for image registration between multi-resolution images. The proposed method creates a circular template at the center of a feature point in a coarse scale image and also a variable circular template in a fine scale image, respectively. After changing the scale of the variable circular template, we rotate the variable circular template by each predefined angle and compute the mutual information between the two circular templates and then find the scale, the angle of rotation and the center location of the variable circular template, respectively, in fine scale image when the mutual information between the two circular templates is maximum. The proposed method was tested using Kompsat-2, Kompsat-3 and Kompsat-3A images with different spatial resolution. The experimental results showed that the error of scale factor, the error of rotation angle and the localization error of the control point were less than 0.004, $0.3^{\circ}$ and one pixel, respectively.

Radio location algorithm in microcellular wide-band CDMA environment (마이크로 셀룰라 Wide-band CDMA 환경에서의 위치 추정 알고리즘)

  • Chang, Jin-Weon;Han, Il;Sung, Dan-Keun;Shin, Bung-Chul;Hong, Een-Kee
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.8
    • /
    • pp.2052-2063
    • /
    • 1998
  • Various full-scale radio location systems have been developed since ground-based radio navigation systems appeared during World War II, and more recently global positioning systems (GPS) have been widely used as a representative location system. In addition, radio location systems based on cellular systems are intensively being studied as cellular services become more and more popular. However, these studies have been focused mainly on macrocellular systems of which based stations are mutually synchronized. There has been no study about systems of which based stations are asynchronous. In this paper, we proposed two radio location algorithms in microcellular CDMA systems of which base stations are asychronous. The one is to estimate the position of a personal station at the center of rectangular shaped area which approximates the realistic common area. The other, as a method based on road map, is to first find candidate positions, the centers of roads pseudo-range-distant from the base station which the personal station belongs to and then is to estimate the position by monitoring the pilot signal strengths of neighboring base stations. We compare these two algorithms with three wide-spread algorithms through computer simulations and investigate interference effect on measuring pseudo ranges. The proposed algorithms require no recursive calculations and yield smaller position error than the existing algorithms because of less affection of non-line-of-signt propagation in microcellular environments.

  • PDF

An accuracy analysis of Cyberknife tumor tracking radiotherapy according to unpredictable change of respiration (예측 불가능한 호흡 변화에 따른 사이버나이프 종양 추적 방사선 치료의 정확도 분석)

  • Seo, jung min;Lee, chang yeol;Huh, hyun do;Kim, wan sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.157-166
    • /
    • 2015
  • Purpose : Cyber-Knife tumor tracking system, based on the correlation relationship between the position of a tumor which moves in response to the real time respiratory cycle signal and respiration was obtained by the LED marker attached to the outside of the patient, the location of the tumor to predict in advance, the movement of the tumor in synchronization with the therapeutic device to track real-time tumor, is a system for treating. The purpose of this study, in the cyber knife tumor tracking radiation therapy, trying to evaluate the accuracy of tumor tracking radiation therapy system due to the change in the form of unpredictable sudden breathing due to cough and sleep. Materials and Methods : Breathing Log files that were used in the study, based on the Respiratory gating radiotherapy and Cyber-knife tracking radiosurgery breathing Log files of patients who received herein, measured using the Log files in the form of a Sinusoidal pattern and Sudden change pattern. it has been reconstituted as possible. Enter the reconstructed respiratory Log file cyber knife dynamic chest Phantom, so that it is possible to implement a motion due to respiration, add manufacturing the driving apparatus of the existing dynamic chest Phantom, Phantom the form of respiration we have developed a program that can be applied to. Movement of the phantom inside the target (Ball cube target) was driven by the displacement of three sizes of according to the size of the respiratory vertical (Superior-Inferior) direction to the 5 mm, 10 mm, 20 mm. Insert crosses two EBT3 films in phantom inside the target in response to changes in the target movement, the End-to-End (E2E) test provided in Cyber-Knife manufacturer depending on the form of the breathing five times each. It was determined by carrying. Accuracy of tumor tracking system is indicated by the target error by analyzing the inserted film, additional E2E test is analyzed by measuring the correlation error while being advanced. Results : If the target error is a sine curve breathing form, the size of the target of the movement is in response to the 5 mm, 10 mm, 20 mm, respectively, of the average $1.14{\pm}0.13mm$, $1.05{\pm}0.20mm$, with $2.37{\pm}0.17mm$, suddenly for it is variations in breathing, respective average $1.87{\pm}0.19mm$, $2.15{\pm}0.21mm$, and analyzed with $2.44{\pm}0.26mm$. If the correlation error can be defined by the length of the displacement vector in the target track is a sinusoidal breathing mode, the size of the target of the movement in response to 5 mm, 10 mm, 20 mm, respective average $0.84{\pm}0.01mm$, $0.70{\pm}0.13mm$, with $1.63{\pm}0.10mm$, if it is a variant of sudden breathing respective average $0.97{\pm}0.06mm$, $1.44{\pm}0.11mm$, and analyzed with $1.98{\pm}0.10mm$. The larger the correlation error values in both the both the respiratory form, the target error value is large. If the motion size of the target of the sine curve breathing form is greater than or equal to 20 mm, was measured at 1.5 mm or more is a recommendation value of both cyber knife manufacturer of both error value. Conclusion : There is a tendency that the correlation error value between about target error value magnitude of the target motion is large is increased, the error value becomes large in variation of rapid respiration than breathing the form of a sine curve. The more the shape of the breathing large movements regular shape of sine curves target accuracy of the tumor tracking system can be judged to be reduced. Using the algorithm of Cyber-Knife tumor tracking system, when there is a change in the sudden unpredictable respiratory due patient coughing during treatment enforcement is to stop the treatment, it is assumed to carry out the internal target validation process again, it is necessary to readjust the form of respiration. Patients under treatment is determined to be able to improve the treatment of accuracy to induce the observed form of regular breathing and put like to see the goggles monitor capable of the respiratory form of the person.

  • PDF

Evaluation of Planning Dose Accuracy in Case of Radiation Treatment on Inhomogeneous Organ Structure (불균질부 방사선치료 시 계획 선량의 정확성 평가)

  • Kim, Chan Yong;Lee, Jae Hee;Kwak, Yong Kook;Ha, Min Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.137-143
    • /
    • 2013
  • Purpose: We are to find out the difference of calculated dose of treatment planning system (TPS) and measured dose in case of inhomogeneous organ structure. Materials and Methods: Inhomogeneous phantom is made with solid water phantom and cork plate. CT image of inhomogeneous phantom is acquired. Treatment plan is made with TPS (Pinnacle3 9.2. Royal Philips Electronics, Netherlands) and calculated dose of point of interest is acquired. Treatment plan was delivered in the inhomogeneous phantom by ARTISTE (Siemens AG, Germany) measured dose of each point of interest is obtained with Gafchromic EBT2 film (International Specialty Products, US) in the gap between solid water phantom or cork plate. To simulate lung cancer radiation treatment, artificial tumor target of paraffin is inserted in the cork volume of inhomogeneous phantom. Calculated dose and measured dose are acquired as above. Results: In case of inhomogeneous phantom experiment, dose difference of calculated dose and measured dose is about -8.5% at solid water phantom-cork gap and about -7% lower in measured dose at cork-solid water phantom gap. In case of inhomogeneous phantom inserted paraffin target experiment, dose difference is about 5% lower in measured dose at cork-paraffin gap. There is no significant difference at same material gap in both experiments. Conclusion: Radiation dose at the gap between two organs with different electron density is significantly lower than calculated dose with TPS. Therefore, we must be aware of dose calculation error in TPS and great care is suggested in case of radiation treatment planning on inhomogeneous organ structure.

  • PDF

Variability in the Effective Spatial Range of the Population Centripetal Force of CBD (도심 인구구심력의 유효범위 변동성 측정)

  • Nam, Kwang-Woo;Kang, In-Joo;Im, Doo-Hyeon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.12 no.2
    • /
    • pp.120-131
    • /
    • 2009
  • This study measured the centripetal force and effective scope of the population spread from urban center and subcenters in order to diagnose the urban spatial structure of the formation of a multicentric city structure in Busan. The study analyzed the variability of the determination coefficient value (R square) with a negative exponential function derived from the population density model by extending the circular region into 5-km units. The aim of this study was to measure changes in the effective scope of the population centripetal force of the urban center and subcenter in 5-year intervals from 1995 to 2005 using census data. The explanatory adequacy of the population density function was examined with the bias of the function to calculate the distance error between the real location of the urban center and the optimal location, according to the population density function. To summarize the results, the value for the area of Jungangdong showed a continuous reduction, whereas Seomyeon (Bujeondong) maintained explanatory adequacy without a large change. As a whole, Busan was in the process of continuous diversification, in spite of its reduced population. Therefore, it appears necessary to strengthen the function of the urban center and subcenter and to supply adequate dwelling zones close to downtown to form a more efficient urban spatial structure. The results of the present study will be utilized as basic data for the formulation of a political approach to the efficient reorganization of spatial structure by correlating concrete spatial information with the population variability of Busan's urban center and subcenter.

  • PDF

Development of Real-Time Vision Aided Navigation Using EO/IR Image Information of Tactical Unmanned Aerial System in GPS Denied Environment (GPS 취약 환경에서 전술급 무인항공기의 주/야간 영상정보를 기반으로 한 실시간 비행체 위치 보정 시스템 개발)

  • Choi, SeungKie;Cho, ShinJe;Kang, SeungMo;Lee, KilTae;Lee, WonKeun;Jeong, GilSun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.6
    • /
    • pp.401-410
    • /
    • 2020
  • In this study, a real-time Tactical UAS position compensation system based on image information developed to compensate for the weakness of location navigation information during GPS signal interference and jamming / spoofing attack is described. The Tactical UAS (KUS-FT) is capable of automatic flight by switching the mode from GPS/INS integrated navigation to DR/AHRS when GPS signal is lost. However, in the case of location navigation, errors accumulate over time due to dead reckoning (DR) using airspeed and azimuth which causes problems such as UAS positioning and data link antenna tracking. To minimize the accumulation of position error, based on the target data of specific region through image sensor, we developed a system that calculates the position using the UAS attitude, EO/IR (Electric Optic/Infra-Red) azimuth and elevation and numerical map data and corrects the calculated position in real-time. In addition, function and performance of the image information based real-time UAS position compensation system has been verified by ground test using GPS simulator and flight test in DR mode.

UAV Photogrammetry Accuracy Analysis at Marine Using Arbitrary Reference Points (임의의 기준점을 이용한 해상에서의 UAV 사진측량 정확도 분석)

  • Oh, Jae Hyun;Kim, Byung Woo;Hwang, Dae Young;Hong, Soon Heon
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.24 no.4
    • /
    • pp.39-45
    • /
    • 2016
  • In this study, with arbitrary reference points on the water, photogrammetry accuracy analysis was conducted using unmanned aerial vehicle(UAV). A small reservoir is a research area, and twenty buoys were used as arbitrary reference points. Errors of location coordinate were identified with control of amounts of used reference points. cases are categorized by index scores per photos. Accuracy of X is 0.141m~0.166m and accuracy of Y is 0.136m~0.241m. Considering that allowable error for the maritime boundary survey is ${\pm}2m$, it is possible to get the accuracy data available for the photogrammetry of UAV using an reference point. In addition, the coefficient of correlation between the number of reference points per unit and number of buoys used as reference point and the ratio of the reference point per square measure, and percentage of buoys used as reference point and the coefficient of x and y were performed. Each element, x, and y showed a strong correlation and the coefficient of number of buoys used as reference point was irrelevant. The results of this correlation analysis can be analyzed that the number of reference points used in each picture is greater than the actual number of reference points used in location accuracy.