• 제목/요약/키워드: Local wall thinning

검색결과 81건 처리시간 0.024초

충돌로 인해 분산된 2상 제트스팀의 재부착 현상과 국부 감육 상관관계 규명 및 설계개선에 관한 연구 (Design Modification and Correlation Verification between Reattachment Flow of Dispersed Jet and Local Thinning of Feedwater Heater)

  • 김형준;김경훈;황경모
    • 설비공학논문집
    • /
    • 제21권9호
    • /
    • pp.483-495
    • /
    • 2009
  • Feedwater heaters of many nuclear power plants have recently experienced severe wall thinning damange, which will increase as operating time progresses. Several nuclear power plants in Korea have experienced wall thinning damage in the area around the impingement baffle-installed downstream of the high pressure turbine extraction stream line-inside number 5A and 5B feedwater heaters. At that point, the extracted steam from the high pressure turbine is two phase fluid at high temperature, high pressure, and high speed. Since it flows in reverse direction after impinging the impingement baffle, the shell wall of the number 5 high pressure feedwater heater may be affected by flow-accelerated corrosion. This paper describes operation of experience and numerical analysis composed similar condition with real high pressure feedwater heater. This study applied squared, curved and new type impingement baffle plates to feedwater heater same as previous study. In addition, it shows difference of pressure distribution and value between single phase and two phase based on experience and numerical analysis.

오리피스 유형별 유동가속부식 영향 분석 (Analysis of Flow-Accelerated Corrosion Effects by the Type of Orifice)

  • 황경모;진태은;김경훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2483-2488
    • /
    • 2008
  • To mitigate the effects of cavitation and flashing, several types of orifices have been installed in the pipeline of new nuclear power plants. To review the effects of wall thinning caused by flow-accelerated corrosion by the types of orifices, which are cone and plate, and the relation between flow behavior and local wall thinning, experiments and numerical analyses for the downstream pipe of two types of orifices were performed. The experimental results in terms of static pressure obtained for the experimental facilities were compared with those of three-dimensional (3D) numerical analyses using the FLUENT code. As the results of review of flow-accelerated corrosion effects based on the experiment and numerical analysis, it was identified that the orifice of cone-type can be comparatively mitigated the effects of cavitation and flashing, but can not be mitigated the effect of flow-accelerated corrosion.

  • PDF

CFD APPLICATION TO THE REGULATORY ASSESSMENT OF FAC-CAUSED CANDU FEEDER PIPE WALL THINNING ISSUE

  • Kang, Dong-Gu;Jo, Jong-Chull
    • Nuclear Engineering and Technology
    • /
    • 제40권1호
    • /
    • pp.37-48
    • /
    • 2008
  • Flow fields inside feeder pipes have been simulated numerically using a CFD (computational fluid dynamics) code to calculate the shear stress distribution, which is the most important factor in predicting the local regions of feeder pipes highly susceptible to FAC (flow-accelerated corrosion)-induced wall thinning. The CFD approach, with schemes used in this study, to simulate the flow situations inside the CANDU feeder pipes has been verified as it showed a good agreement between the investigation results for the failed feedwater pipe at Surry unit 2 plant in the U.S. and the CFD calculation. Sensitivity studies of the three geometrical parameters, such as angle of the first and second bends, length of the first span between the grayloc hub and the first bend, and length of the second span between the first and the second bends have been performed. CFD analysis reveals that the local regions of feeder pipes of Wolsung unit 1 in Korea, on which wall thickness measurements have been performed so far, are not coincident with the worst regions predicted by the present CFD analysis located in the connection region of straight and bend pipe near the inlet part of the bend intrados. Finally, based on the results of the present CFD analysis, a guide to the selection of the weakest local positions where the measurement of wall thickness should be performed with higher priority has been provided.

복합하중이 작용하는 국부감육배관 평가법 개발 (Development of Assessment Methodology for Locally Wall-Thinned Pipe Under Combined Loading)

  • 심도준;김윤재;김영진;박치용
    • 대한기계학회논문집A
    • /
    • 제29권10호
    • /
    • pp.1399-1406
    • /
    • 2005
  • Recently authors have proposed a new method to estimate failure strength of a pipe with local wall thinning subject to either internal pressure or global bending. The proposed method was based on the equivalent stress averaged over the minimum ligament in the locally wall thinned region, and the simple scheme to estimate the equivalent stress in the minimum ligament was proposed, based on the reference stress concept. This paper extends the new method to combined internal pressure and global bending. The proposed method is validated against FE results for various geometries of local wall thinning under combined loading. The effect of internal pressure is also investigated in the present study. Comparison of maximum moments, predicted according to the proposed method, with published full-scale pipe test data fur locally wall-thinned pipes under combined internal pressure and global bending, shows good agreement.

THINNED PIPE MANAGEMENT PROGRAM OF KOREAN NUCLEAR POWER PLANTS

  • Lee, S.H.;Lee, Y.S.;Park, S.K.;Lee, J.G.
    • Corrosion Science and Technology
    • /
    • 제14권1호
    • /
    • pp.1-11
    • /
    • 2015
  • Local wall thinning and integrity degradation caused by several mechanisms, such as flow accelerated corrosion (FAC), cavitation, flashing and/or liquid drop impingements, are a main concern in carbon steel piping systems of nuclear power plant in terms of safety and operability. Thinned pipe management program (TPMP) had been developed and optimized to reduce the possibility of unplanned shutdown and/or power reduction due to pipe failure caused by wall thinning in the secondary side piping system. This program also consists of several technical elements such as prediction of wear rate for each component, prioritization of components for inspection, thickness measurement, calculation of actual wear and wear rate for each component. Decision making is associated with replacement or continuous service for thinned pipe components. Establishment of long-term strategy based on diagnosis of plant condition regarding overall wall thinning is also essential part of the program. Prediction models of wall thinning caused by FAC had been established for 24 operating nuclear plants. Long term strategies to manage the thinned pipe component were prepared and applied to each unit, which was reflecting plant specific design, operation, and inspection history, so that the structural integrity of piping system can be maintained. An alternative integrity assessment criterion and a computer program for thinned piping items were developed for the first time in the world, which was directly applicable to the secondary piping system of nuclear power plant. The thinned pipe management program is applied to all domestic nuclear power plants as a standard procedure form so that it contributes to preventing an accident caused by FAC.

감육배관 손상시험 결과를 이용한 국부손상기준 검증 (Validation of a Local Failure Criteria Using the Results of Wall-Thinned Pipe Failure Tests)

  • 김진원;이성호;박치용
    • 대한기계학회논문집A
    • /
    • 제33권12호
    • /
    • pp.1393-1400
    • /
    • 2009
  • The objective of this study is to validate local failure criteria, which were proposed based on the notched-bar specimen tests combining with finite element (FE) simulations, using the results of real-scale pipe failure tests. This study conducted burst test using wall-thinned pipe specimens, which were made of 4 inch Sch.80 ASTM A106 Gr.B carbon steel pipe, under simple internal pressure at ambient temperature and performed associated FE simulations. Failure pressures were estimated by applying the failure criteria to the results of FE simulations and were compared with experimental failure pressures. It showed that the local stress based criterion, given as true ultimate tensile stress of material, accurately estimated the failure pressure of wall-thinned pipe specimens. However, the local strain based criterion, which is fracture strain of material as a function of stress tri-axiality, could not predict the failure pressure. It was confirmed that the local stress based criterion is reliably applicable to estimation of failure pressure of local wall-thinned piping components.

열림·닫힘 방향 하중이 고려된 두께 감소된 엘보우의 건전성평가 (The Structure Integrity Assessment of the Wall Thinned Elbow Considering In/Out-Plane Bending)

  • Jang, Ungburm;Shin, Kyuin;Lee, Sungho;Kuan, Changhee
    • 한국재난정보학회 논문집
    • /
    • 제12권1호
    • /
    • pp.1-9
    • /
    • 2016
  • 국부적인 두께감소 문제에 대하여 직관부위를 대상으로 한 건전성 평가는 잘 알려져 있으나 엘보우를 대상으로 한 건전성 평가는 최근에 원자력 분야에서는 많은 연구가 이루어지고 있으나 석유화학 플랜트에서 이용되는 건전성 평가 지침서 중 하나인 API579 코드에는 아직 없는 실정이다. 이에 본 연구에서는 엘보우를 대상으로 엘보우의 외부(extrados)와 내부(intrados)에 두께 감소가 있다고 가정한 후 유한요소해석법을 이용하여 두께감소된 엘부우의 건전성평가 해석을 수행하였다. 본 해석 결과는 석유화학 플랜트에서 이용되는 엘보우의 건전성 평가에 이용될 수 있음을 보여주었다.

급수밸브 내부의 유동경로 수치해석 (Numerical Analysis of Flow Path inside the Feedwater Valve)

  • 곽승현;원용휘
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2006년 창립20주년기념 정기학술대회 및 국제워크샵
    • /
    • pp.416-419
    • /
    • 2006
  • Numerical analysis is carried out to identify the wall thinning effect inside the feed water valve. The finite volume method is applied to make analysis for the viscous flows. The commercial cock FLUENT is used for the simulation and the GAMBIT for the grid generation. The RNG $\kappa-\varepsilon$ model is used for the turbulence and the tet-hybrid grid is applied for the modeling. The velocity vector, the pressure contour, the change of residual along the iteration number, and the dynamic head are predicted for the hydrodynamic investigation.

  • PDF