• Title/Summary/Keyword: Local sources

Search Result 673, Processing Time 0.025 seconds

Second-order nonstationary source separation; Natural gradient learning (2차 Nonstationary 신호 분리: 자연기울기 학습)

  • 최희열;최승진
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2002.04b
    • /
    • pp.289-291
    • /
    • 2002
  • Host of source separation methods focus on stationary sources so higher-order statistics is necessary In this paler we consider a problem of source separation when sources are second-order nonstationary stochastic processes . We employ the natural gradient method and develop learning algorithms for both 1inear feedback and feedforward neural networks. Thus our algorithms possess equivariant property Local stabi1iffy analysis shows that separating solutions are always locally stable stationary points of the proposed algorithms, regardless of probability distributions of

  • PDF

PM Management Methods Considering Condensable PM Emissions from Stationary Sources in Seoul and Incheon (고정오염원의 응축성 먼지 배출량을 고려한 서울과 인천의 먼지 관리방안)

  • Lee, Im Hack;Choi, Doo Sung;Ko, Myeong Jin;Park, Young-Kwon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.4
    • /
    • pp.319-325
    • /
    • 2017
  • In this study, the new particulate matter emissions considering condensable PM (CPM) of stationary pollutant sources were calculated to modify the CAPSS emissions based on only filterable PMs in Seoul and Incheon. When the new calculated emissions were compared to the existing filterable PM based emissions of local governments, different contribution patterns of emission sources were found. For example, the proportion of mobile sources was high when the filterable PM was considered; however, the contribution of non-industrial sources was dominant in Seoul when the emissions of CPM were considered. Also, the proportion of energy industrial combustion and manufacturing combustion sources was significant in Incheon when CPM emissions considered. Therefore, it seems to be much desirable to consider CPM emissions for determining adequate locations of collective energy facilities and manufacturing combustion facilities in the future. In addition, CPM should be considered to solve the dust problem nationwide. The emission analysis, diagnosis, prediction and countermeasures using CPM emissions should be appropriately performed.

VOCs Emission Characteristics and Mass Contribution Analysis at Wanju Industrial Area (완주지역의 VOCs 배출특성에 따른 공단지역과 일반지역의 기여도 분석)

  • Kim, Deug-Soo;Yang, Go-Soo;Park, Bi-O
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.5
    • /
    • pp.562-573
    • /
    • 2008
  • Concentrations of volatile organic compounds (VOCs) measured from the local industrial sources in Wanju industrial complex during June $2007{\sim}January$ 2008. The samples were collected from the primary sources (6 emission points) in 4 major factories in Wanju industrial complex as well as two general sources in Wanju County to elucidate the abundances of speciated VOCs and their spacial and temporal distributions depending on source bases. Industrial sources are as follows; fabricated metal manufacture, motor vehicle manufacture, rubber and plastic manufacture, and chemical manufacture factories. Two general source samples were collected from gasoline gas station and dry cleaning shop in urban area. In order to understand the near source influence at receptor, samples from the two receptor sites (one is at center of the industrial complex and the other site is at distance residential area downwind from the center) were collected with sample canister, and analyzed by using GC/MSD. The concentrations from different sources were compared and discussed. The mass contributions of the speciated VOCs to total VOCs measured from industrial sources and ambient ai r at two receptors were presented and discussed.

A Study on the Preheating Effect of Multi-Heat Sources using Laser Plasma in the Thermally Assisted Machining of a High-Melting-Point Material (고융점 소재의 열 보조 가공에서 레이저 -플라즈마 다중열원의 예열 효과에 대한 연구)

  • Lee, Choon-Man;Kim, Seong-Gyu
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.10
    • /
    • pp.93-98
    • /
    • 2019
  • Recently, with the development of the aerospace and automotive industries, the demand for high-melting-point materials has increased. However, high-melting-point materials are difficult to cut through conventional machining methods. Thermally assisted machining (TAM) is a method for improving the machinability by preheating the materials. A laser, the most commonly used device for TAM, has high efficiency through local preheating but is not sufficient for maintaining a high preheating temperature due to rapid cooling. However, the use of multi-heat sources can supplement the disadvantage of a single heat source. The high preheating temperature can be maintained with a wide and deep heat-affected zone (HAZ) by multi-heat sources. The purpose of this study is to analyze the preheating effects of multi-heat sources using laser plasma. Thermal analysis and preheating experiments were carried out. As a result, the high preheating effect of multi-heat sources compared with a single heat source was verified.

2 - 4 ㎛ Spectroscopy of Red Point Sources in the Galactic Center

  • Jang, DaJeong;An, Deokkeun;Sellgren, Kris;Ramirez, Solange V.;Boogert, Adwin;Geballe, Tom
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.49.2-49.2
    • /
    • 2019
  • We present results from our long-term observing campaign, using the NASA IRTF at Maunakea, to obtain 2 - 4 ㎛ spectra of 118 red point sources in the line of sight to the Galactic Center (GC). Our sample is largely composed of point sources selected from near- and mid-infrared photometry, but also includes a number of massive young stellar objects. Many of these sources show high foreground extinction as shown by deep 3.4 ㎛ aliphatic hydrocarbon absorption feature, which is a characteristic of the diffuse ISM and comes from the long line of sight through the diffuse medium toward the Central Molecular Zone (CMZ), the central 300 pc region of the GC. The deep 3.1 ㎛ H2O ice absorption band coming from the local, dense material in the GC CMZ suggests that most sources are likely located in the GC CMZ. A few of these sources show weak CCH3OH ice absorption at 3.535 ㎛, which can provide a strong constraint on the CCH3OH ice formation in the unique environment of the CMZ. From the best-fitting models, the optical depths of these features are determined and used to generate a well-rounded view of the ice composition across the GC CMZ and the spectral characteristics of massive YSOs in the GC.

  • PDF

Edge Detection By Fusion Using Local Information of Edges

  • Vlachos, Ioannis K.;Sergiadis, George D.
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2003.09a
    • /
    • pp.403-406
    • /
    • 2003
  • This paper presents a robust algorithm for edge detection based on fuzzy fusion, using a novel local edge information measure based on Renyi's a-order entropy. The calculation of the proposed measure is carried out using a parametric classification scheme based on local statistics. By suitably tuning its parameters, the local edge information measure is capable of extracting different types of edges, while exhibiting high immunity to noise. The notions of fuzzy measures and the Choquet fuzzy integral are applied to combine the different sources of information obtained using the local edge information measure with different sets of parameters. The effectiveness and the robustness of the new method are demonstrated by applying our algorithm to various synthetic computer-generated and real-world images.

  • PDF

An Estimation of Direct and Indirect GHG-AP Integrated Emissions from Energy Sector in Seoul (2010) (서울시 에너지부문 직·간접 온실가스-대기오염 통합 배출량(2010) 산정)

  • Jung, Jaehyung;Kwon, O-Yul
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.2
    • /
    • pp.150-160
    • /
    • 2014
  • Greenhouse gas (GHG) and Air Pollution (AP) emission inventories have been constructed and estimated independently up-to-date in Seoul. It causes difficulty in GHG and AP integrated management due to a difference in emission inventories. In this study, we constructed GHG and AP integrated emission inventories for direct and indirect sources in Seoul during the year 2010 in Energy activities for estimating GHG and AP emissions were derived from IPCC guideline, guidelines for local government greenhouse inventories, air pollutants calculation manual, and Indirect Emission Factors (IEF) reported by Korea Power Exchange. The annual GHG emission was estimated as 50,530,566 $tonCO_{2eq}$, of which 54.8% resulted from direct sources and the remaining 45.2% from indirect sources. Among direct sources, transportation sector emitted the largest GHG, accounting for 47.3% of the total emission from direct sources. As with indirect sources, purchased electricity sector only emitted 98.6% of the total emission from indirect sources. The annual AP emission was estimated as 283,701 tonAP, of which 85.9% was contributed by the combined AP emissions of transportation and fugitive sectors. Estimation of individual air pollutant showed that the largest source were transportation sector for CO, $NO_x$, TSP, $PM_{10}$ and NH3, non-energy sector for $SO_x$, and fugitive sector for VOCs. This study found some limitations in estimating GHG and AP integrated emissions, such as nonconforming emission inventories between GHG and AP, and no indirect AP emission factor of purchased electricity, and so on. Those should be further studied and improved for more effective GHG and AP integrated management.

A Study on Determining the Size of the Interface Inductor for Grid-Connected Micro-Sources (Micro-Source의 계통 연계용 인덕터 크기 선정에 관한 연구)

  • Son, Kwang-Myung;Kim, Young-Seob
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.52-58
    • /
    • 2005
  • The concept of the Micro-Grid comprising Micro-Sources supplying both heat and power ranging from several [KW] to 1[MW] to local customers is proposed by CERTS(Consortium for Electric Reliability Technology Solutions). Micro-Sources adopt environmentally friendly and reliable power sources such as Fuel-Cell and Micro-Turbines. Micro-Sources adopt voltage source inverter with AC grid system in order to provide independent real and reactive power control for premium power quality. Thus Micro-Source needs series inductance for interfacing with AC grid system. With this reason, we propose a technique that can decide the optimal size of the inductor for effective transfer of the power into the grid.

Evaluation of Water Supply and Selection of Deficient Districts in Gunwigun Farmland for Drought Response (가뭄대책 수립을 위한 군위군 경작지의 용수공급 평가와 부족지구의 선정)

  • Ahn, Seung Seop;Park, Ki bum
    • Journal of Environmental Science International
    • /
    • v.29 no.11
    • /
    • pp.1099-1108
    • /
    • 2020
  • In this study, the capacity of supplying agricultural water to 13 districts was analyzed by calculating the necessary water supply for the arable land of Gunwi-gun and examining the capacity of supplying water to reservoirs, streams, pumping stations, collection sites, and groundwater wells in Gunwi-gun. As a result, among the 13 districts the second district was found to be short of water by 1.2×106 tons/year. In general, local governments establish drought measures by selecting drought disaster risk zones. While selecting drought-risk areas, some water-poor areas that do not have water sources should be selected, even if the entire area has a sufficient water supply. The water-supply evaluation at the regional level was insufficient for locating areas without water sources, but most areas with water sources, such as streams, reservoirs, and pumping stations, were found to have no shortage of water. To locate water shortage areas without water sources, GIS analysis conducted a field survey of areas with a distance of 4 or less than that of water sources analyzed by GIS analysis. Sixty-nine sites in 13 districts were selected for the on-site survey and six areas of water shortage were identified in areas other than the second district.

Perceptions of Key Stakeholders Towards Sustainable Tourism Development: A Case Study in Mekong Delta, Vietnam

  • VU, Hieu Minh;LAM, Trung Minh;PRABHAKARAN, Sudesh
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.4
    • /
    • pp.717-726
    • /
    • 2021
  • Tourism is one of the key economic drivers not only in Vietnam but also in the world. This study explores the awareness and perceptions of key stakeholders such as local residents, tourism businesses, and tourists on sustainable tourism development in the Mekong Delta in Vietnam. Both quantitative and qualitative research approaches have been used with the secondary and primary data to provide insights on the subject. The secondary data is from vast sources, including the governmental department of tourism, statistical departments, annual all-level governmental reports, businesses, and others. The primary data is from the survey by questionnaires with 230 enterprises, 720 local residents, and 670 tourists and from the semi-structured and in-depth interviews conducted with local residents, businesses, tourists, local authorities' officers, and especially with 5 experts who are also stakeholders of Mekong Delta tourism. The results will help the related authorities understand the awareness and perceptions of the key stakeholders and deliver valuable information and a concrete delineated roadmap toward sustainable tourism development of the research settings.