• Title/Summary/Keyword: Local source

Search Result 969, Processing Time 0.027 seconds

Ground Thermal Conductivity Test with A Wireless Probe (무선 전자식 장비를 이용한 지중열전도도 측정 기술)

  • Kim, Ji-Young;Lee, Euy-Joon;Chang, Ki-Chang;Kang, Eun-Chul;Ko, Gun-Hyuk
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2381-2384
    • /
    • 2008
  • The heat exchange between the Borehole Heat Exchanger(BHE) and the surrounding ground depends directly on ground thermal conductivity k at the certain site. The k is thus a key parameter in designing BHE and coupled geothermal heat pump systems. Currently, although a thermal hydraulic Response Test(TRT) is mostly used in practice, the thermal hydraulic TRT needs additional power and is generally time-consuming. A new, simple wireless probe for hi-speed k determination was introduced in this paper. This technique using a wireless probe is less time-consuming and requires no external source of energy for measurement and predicts local thermal properties by measuring soil temperatures along the depth. Measured temperature data along the depth was analyzed. As a result, the electronic wireless probe can replace the conventional hydraulic TRT method after carrying out the additional research on a lot of local heat flow, etc.

  • PDF

Making inferior alveolar nerve block more comfortable via computer-controlled local anesthetic delivery: A prospective clinical study

  • Gajendragadkar, Kunal;Bhate, Kalyani;Jagtap, Bhagyashree;Santhoshkumar, S.N;Kshirsagar, Kapil;Magoo, Surabhi
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.19 no.3
    • /
    • pp.135-141
    • /
    • 2019
  • Background: The fear of needle insertion and pain during anesthesia is a source of patient dissatisfaction in dentistry. Inferior alveolar nerve block (IANB) remains the most common type of block and is in itself painful. Computer-controlled local anesthetic delivery (CCLAD) has been proven to reduce the pain associated with injection of anesthetics in various blocks. However, the efficacy of CCLAD for IANB in adults remains unknown. Methods: Sixty-four adult patients requiring bilateral IANB were selected and divided into two groups: group A (50 patients receiving IANB via CCLAD) and group B (50 patients receiving IANB using a conventional cartridge syringe). Pain perception and patient comfort were assessed using the visual analog scale and the 5-point semantic scale, respectively. Results: The pain perception was compared between the two groups using the Mann-Whitney U-test, and the P value was 0.003. The patient comfort was also compared using the same test, and the P value was 0.484. Conclusion: A significant difference was observed in the pain perception of the patients during CCLAD. The patient comfort was grossly equal for both techniques.

A Study on the Improvement Policy of the Localization Parts of the Defense Sector (국방분야 부품국산화개발 정책개선 방안)

  • Jung, Suk-Yun;Eom, Jung-Ho
    • Journal of National Security and Military Science
    • /
    • s.15
    • /
    • pp.117-151
    • /
    • 2018
  • The development of local defense parts has played a role a pure function such as maintenance of stable procurement source of military goods, provision of timely supply, establishment of self-defense base, creation of import substitution effect considering the whole life-cycle cost, reduction of foreign currency and protection of domestic defense industry. However, as the development success rate is deteriorating, it is time to analyze the related policies and improve the system. In order to improve the success rate of development of parts for the defense sector, it is necessary to unify the separated policies by the development-related departments and strengthen the policy support for the development companies to actively participate in the development. In addition, it is necessary to improve the paradigm for the selection of development items and change the authority of selecting development items and to delegate authority to create synergies. Parts localization development policy improvement is military support side it will contribute to strengthening defense power management by organically combining with technological development aspect and economical aspect. Development items will be linked to defense exports, which will have a remarkable effect on sales growth and job creation effects. The development of local defense parts is spreading.

  • PDF

A Study on Heat Transfer Performance of Vertical Ground Heat Exchanger of GSHP(Ground Source Heat Pump) (GSHP용 수직형 지중열교환기의 열전달 성능에 관한 연구)

  • Chung, Min-Ho;Chang, Ki-Chang;Ra, Ho-Sang;Baik, Young-Jin;Park, Seong-Ryong;Yoo, Seong-Yeon
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2102-2107
    • /
    • 2007
  • GSHP systems are used for air-conditioning systems in commercial buildings, schools, and factories because of low operating and maintenance costs. These systems use the earth as a heat source in heating and a heat sink in cooling mode. Ground heat exchangers are classified by a horizontal and vertical type according to the installation method. Vertical type is usually constructed by placing small diameter high density polyethylene tube in a vertical borehole. Vertical tube sizes range from 20 to 40 mm nominal diameter. Borehole depth range between 100 and 200 m depending on local drilling conditions and available equipment. In this study, to evaluate the performance of single u-tube with bentonite grouting, single u-tube with broken stone grouting and double u-tube bentonite grouting of vertical ground heat exchangers, test sections are buried on the earth and experimental apparatus is installed. Therefore the heat transfer performance and pressure loss of these are estimated.

  • PDF

Limitations and improvement of the in situ measurements of ground thermal conductivity in Korea (국내 지중열전도도 측정 방법의 한계 및 개선 방향)

  • Shim, Byoung Ohan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.195.2-195.2
    • /
    • 2011
  • The borehole heat exchanger of Geothermal Heat Pump (GHP) system should be sustainable and cost effective for long term operation. To guaranty the performance of the system thermal Response Tests (TRTs) with simple recommended procedures have been applied in many countries. Korea government developed a standard TRT procedure in order to control the quality on GHP projects. In the TRT procedure interpretation method has a rule that data set has to be interpreted by the line source model(LSM). The LSM employes some assumptions that surrounding medium is homogeneous and the line source is infinite and constant heat flux, however real ground condition is unisotropic and heterogeneous, and showing regional or local ground water flows in many cases. We need to develope improved evaluation models to estimate accurate ground thermal conductivity with respect to geological and influence of ground water because current TRT standard test procedure has limitations to be applied for every locations and system. This study surveyed the uncertainty of the thermal parameters from the interpretation method considering different evaluation period. The interpretation of 208 TRT data sets represents limitations of LSM application that some obtained ground thermal conductivities are statistically unstable and convergence time of ground thermal conductivity over test period shows trends responding the length of test period. This evaluation study will be helpful to provide some effective procedure for the thermal parameter estimation and to complement current TRT standard procedure.

  • PDF

QUALITATIVE PROPERTIES OF WEAK SOLUTIONS FOR p-LAPLACIAN EQUATIONS WITH NONLOCAL SOURCE AND GRADIENT ABSORPTION

  • Chaouai, Zakariya;El Hachimi, Abderrahmane
    • Bulletin of the Korean Mathematical Society
    • /
    • v.57 no.4
    • /
    • pp.1003-1031
    • /
    • 2020
  • We consider the following Dirichlet initial boundary value problem with a gradient absorption and a nonlocal source $$\frac{{\partial}u}{{\partial}t}-div({\mid}{\nabla}u{\mid}^{p-2}{\nabla}u)={\lambda}u^k{\displaystyle\smashmargin{2}{\int\nolimits_{\Omega}}}u^sdx-{\mu}u^l{\mid}{\nabla}u{\mid}^q$$ in a bounded domain Ω ⊂ ℝN, where p > 1, the parameters k, s, l, q, λ > 0 and µ ≥ 0. Firstly, we establish local existence for weak solutions; the aim of this part is to prove a crucial priori estimate on |∇u|. Then, we give appropriate conditions in order to have existence and uniqueness or nonexistence of a global solution in time. Finally, depending on the choices of the initial data, ranges of the coefficients and exponents and measure of the domain, we show that the non-negative global weak solution, when it exists, must extinct after a finite time.

A Comparative Analysis of the Perception of Vinegar-Based Sauce for Foreign Consumers - with a Focus on the United States and China - (해외 소비자의 식초기반 소스에 대한 인식 비교분석 - 미국과 중국을 중심으로 -)

  • Jin, Yang-Ho;Kwon, Hyeok-Sung;Bae, Se-Jeong
    • Journal of the Korean Society of Food Culture
    • /
    • v.32 no.5
    • /
    • pp.412-420
    • /
    • 2017
  • This study present base data for development of vinegar-based source and marketing strategies for penetration of the global market for local source companies by comparing and analyzing the awareness and choice factors of vinegar-based sauces by foreign consumers. Preference (p<0.05), matching food (p<0.001), number of purchases (p<0.001), place of purchase (p<0.001), information source (p<0.001), importance of selective attributes (p<0.05), and most frequently purchased vinegar-based sauces (p<0.01) differed significantly according to nationality. There were also significant differences by nationality in purchase intention (p<0.05), packaging (p<0.001), and purchase considerations (p<0.001) of naturally fermented vinegar-based sauce. Developing of vinegar-based sauces and menus should be combined so that it suitable for the food culture of each country.

Unambiguous Identification of Fugitive Pollutants and Determination of Annual Emission Flux as Diurnal Monitoring Mode

  • Chang, Shih-Yi;Tso, Tai-Ly;Lo, Jiunn-Gung;Huang, Jer-Luen;Lin, Cheng Ming
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.731-738
    • /
    • 1995
  • Toxic air pollutants are investigated in a petrochemical industrial park in Taiwan by using a movable open path FTIR. The results show the qualitative and quantitative analysis of emission gases from plants, and also provide the emission rate of different compounds. More than twenty compounds under usual operation are found from this industrial park. The concentration variation with time can be correlated exactly with wind direction. It means that by changing the measuring points, the source of emission can be unambiguously identified. An EPA proved PAL model is applied to estimate the emission rate of either a point or an area source. Local atmospheric stability is determined by releasing the $SF_6$ tracer. The origins of errors come mainly from the uncertainty of source's configuration and the variation of meteorological condition. Through the continuous measurement (half an hour base in this study) of OP-FTIR sensor, the maximum value of emission rate and the annual amount of emission can be derived. The emission rate of the measured toxic gases are derived by the model technique and the results show that the emission amount are in the order of ten to hundred tons per year.

  • PDF

A Device of Static Buffer Overflow Detection by using Function Summary and Tracking Information Flow of Buffer Domain (함수요약 및 버퍼의 도메인 정보흐름 추적에 의한 정적 버퍼넘침 탐지방안)

  • Lee, Hyung-Bong;Park, Jeong-Hyun;Park, Hyun-Mee
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.7 no.6
    • /
    • pp.703-714
    • /
    • 2001
  • In C language, a local buffer overflow in stack can destroy control information stored near the buffer. In case the buffer overflow is used maliciously to overwrite the stored return address, the system is exposed to serious security vulnerabilities. This paper analyzes the process of buffer overflow hacking and methodologies to avoid the attacks in details. And it proposes a device of static buffer overflow detection by using function summary and tracking information flow of buffer domain at assembly source code level(SASS, Static Assembly Source code Scanner) and then show the feasibility and validity of it by implementing a prototype in Pentium based Linux environment.

  • PDF

On the Characteristics of MSE-Optimal Symmetric Scalar Quantizers for the Generalized Gamma, Bucklew-Gallagher, and Hui-Neuhoff Sources

  • Rhee, Jagan;Na, Sangsin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.7
    • /
    • pp.1217-1233
    • /
    • 2015
  • The paper studies characteristics of the minimum mean-square error symmetric scalar quantizers for the generalized gamma, Bucklew-Gallagher and Hui-Neuhoff probability density functions. Toward this goal, asymptotic formulas for the inner- and outermost thresholds, and distortion are derived herein for nonuniform quantizers for the Bucklew-Gallagher and Hui-Neuhoff densities, parallelling the previous studies for the generalized gamma density, and optimal uniform and nonuniform quantizers are designed numerically and their characteristics tabulated for integer rates up to 20 and 16 bits, respectively, except for the Hui-Neuhoff density. The assessed asymptotic formulas are found consistently more accurate as the rate increases, essentially making their asymptotic convergence to true values numerically acceptable at the studied bit range, except for the Hui-Neuhoff density, in which case they are still consistent and suggestive of convergence. Also investigated is the uniqueness problem of the differentiation method for finding optimal step sizes of uniform quantizers: it is observed that, for the commonly studied densities, the distortion has a unique local minimizer, hence showing that the differentiation method yields the optimal step size, but also observed that it leads to multiple solutions to numerous generalized gamma densities.